• Title/Summary/Keyword: 7mm or less

Search Result 364, Processing Time 0.025 seconds

Development of official assay method for loperamide hydrochloride capsules by HPLC

  • Le, Thi-Anh-Tuyet;Nguyen, Bao-Tan;Kim, Min-Ho;Kim, Bit;Kim, Hyun-Soo;Jeong, Seung-Won;Kang, Jong-Seong;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.33 no.6
    • /
    • pp.252-261
    • /
    • 2020
  • Currently, the potentiometric titration and the high pressure liquid chromatography (HPLC) method were utilized in Korean Pharmacopoeia XII (KP XII) as well as other pharmacopoeias (USP, EP, BP) for determination of loperamide hydrochloride in raw materials and capsules, respectively. The research objective is to overcome the remaining drawbacks from current methods such as solubility of mobile phase (KP XII), less scientific approach (USP 43) or using paired-ion chromatography reagent which shows some limitations (BP2017 and other formulation monographs). The proposed method was optimized by Design of Experiment (DoE) tool to obtain the satisfied method for determination of loperamide hydrochloride. The optimal condition was performed on the common C18 column (150 mm × 4.6 mm; 5 ㎛) using isocratic elution with the mobile phase containing 40 mM of potassium phosphate monobasic (pH 3.0) and acetonitrile (56:44), at a flow rate of 0.7 mL/min. The optimized method was validated and met the requirements of the International Conference on Harmonization. The developed method was applied to determine loperamide hydrochloride in capsules and can be used to update the current monograph in KP XII.

Clinical Evaluation of Mycoplasma pneumoniae Antibody Titer and Laboratory Tests in Acute Mycoplasma pneumoniae Pneumonia (급성기 Mycoplasma 폐렴의 항체가와 검사소견에 관한 고찰)

  • Lee, Eun Hee;Lee, So Ra;Kim, Hwa In;Kim, Jong Duck
    • Pediatric Infection and Vaccine
    • /
    • v.6 no.1
    • /
    • pp.93-100
    • /
    • 1999
  • Purpose : For evaluation of acute Mycoplasma pneumoniae(M. pneumoniae) pneumonia in children, we have studied the Mycoplasma indirect particle agglutination test, cold hemagglutinin test, ESR, CRP, and total white blood cell counts and it's differential count retrospectively. Methods : The total numbers of patients whom compatible with diagnostic criteria of acute M. pneumoniae peumonia were 56 cases from Jan. to Dec. 1997. The diagnostic criteria were 1) onset of fever(${\geq}38.0^{\circ}C$) and coughing were within 7 days, 2) rhonchi and/or role was audible on chest, 3) pneumonic infiltration on chest X-ray, and 4) M. pneumoniae indirect particle agglutination test titer was higher than 1:640, or initial titer was less than 1:640 but increased more than 4 folds after week. We classified the enrolled patients according to initial antibody titer, such as soup A(${\leq}1:640$) and group B(${\geq}1:320$). We compared group A and B by demographic findings, clinical symptoms and signs, and laboratory findings. Results : 1) The male and female sex ratio was 1:1.4, and average onset age was $5.8{\pm}2.96$ years. 2) The average body temperature on admission was $38.5{\pm}0.1^{\circ}C$ and productive coughing was noticed in 52 cases(93%). 3) The average total white cell counts were $10,470{\pm}877.0/mm^3$ in group B patients, which was significantly higher compared to $7,761{\pm}508.5/mm^3$ in group A(p<0.014). 4) The average value of ESR and CRP were within normal range in both group. 5) The most common site of pneumonic infiltration was right lower lobe of lung in both groups. 6) There were no correlation between antibody titer and cold hemagglutinine titer in patients and cold hemagglutination titer were less than 1:64 in 25 cases(45%). Conclusion : The clinical manifestations of pneumonia, findings of chest x-ray, and indirect particle agglutination test were useful on diagnosis of M. pneumoniae pnumonia onset within 7 days, but cold hemagglutinin test was a little diagnostic meaning.

  • PDF

Effect of FSH Pretreatment on Follicle Development and Oocyte Recovery by Ultrasound-guided Aspiration in Holstein Heifers (젖소의 초음파 유도 채란율에 대한 FSH 전처리 효과의 비교)

  • Park, Chung-Saeng;Jo, Seong-Geun;Lee, Jeong-Gyu;Gang, Tae-Yeong;Park, Seong-Jae;Gong, Il-Geun;Choe, Min-Cheol
    • Korean Journal of Animal Reproduction
    • /
    • v.21 no.2
    • /
    • pp.147-156
    • /
    • 1997
  • Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.

  • PDF

Profile of chronic and aggressive periodontitis among Senegalese

  • Benoist, Henri Michel;Seck-Diallo, Adam;Diouf, Abdoulaye;Yabbre, Salama;Sembene, Malick;Diallo, Papa Demba
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.6
    • /
    • pp.279-284
    • /
    • 2011
  • Purpose: To describe the profile of chronic and aggressive periodontitis among Senegalese (West Africans) attending the Institute of Dentistry of Dakar. Methods: A retrospective study was conducted with an inclusion period running from 2001 to 2008. The sample included 413 chronic periodontitis and 151 aggressive periodontitis cases, among them 299 males and 265 females selected from 2,274 records. A Student's independent t-test or Pearson chi-squared test was used for data analysis. Results: The proportion of females with aggressive periodontitis was significantly higher than those with chronic periodontitis (64.9% vs. 40.4%, P<0.001). The aggressive periodontitis patients had an average age of $28.1{\pm}8.9$ years, and had lost less than 3 teeth. Less than a third of them reported using a toothbrush. Attachment loss was as high as 8 mm and severe lesions had spread to an average of 12 teeth with maximum alveolar bone loss up to 80%. The chronic periodontitis patients had an average age of $44.9{\pm}14.0$ and had lost on average less than 3 teeth. Nearly 75% used a toothbrush. Attachment loss was significantly higher and lesions were more extensive in the aggressive periodontitis. Chronic periodontitis is associated with risk factors such as smoking or diabetes mellitus in 12.8% versus 0.7% in aggressive periodontitis (P<0.001). Differences between the two groups for most clinical and radiographic parameters were statistically significant. Conclusions: The profile of aggressive periodontist is characterized by more severe lesions than chronic periodontitis, whereas tooth loss experience is similar in both forms.

Advanced Wastewater Treatment Process Using Aerobic Granular Sludge (AGS-SBR) (호기성 그래뉼 슬러지를 이용한 하수고도처리기술(AGS-SBR))

  • Choi, Han Na;Mo, Woo Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.47-54
    • /
    • 2021
  • Aerobic granular sludge (AGS) can be classified as a type of self-immobilized microbial aggregates measuring more than 0.2 mm. It offers the option to simultaneously remove COD, N, and P that occur in different zones inside a granule. Also, AGS is characterized by high precipitability, treatability with high organic loading, and high tolerance to low temperature. In this study, a sequencing batch reactor inoculated with AGS (AGS-SBR) is a new advanced wastewater treatment process that was proven to grow AGS with integrated nutrient removal and low C/N ratio. A pilot plant, AGS-SBR with a capacity of 225 ㎥/d was installed at an S sewage treatment plant in Gyeonggi-do. The results of the operation showed that the water quality of the effluent indicated that the value of BOD5 was 1.5 mg/L, CODMn was 11.4 mg/L, SS was 6.2 mg/L, T-N was 13.2 mg/L, and T-P was 0.197 mg/L, and all of these values reliably satisfied an effluent standard (I Area). In winter, the T-N treatment efficiency at a lower temperature of less than 11℃ also showed reliability to meet the effluent standard of the I Area (20 mg/L or less). Analysis of microbial community in AGS showed a higher preponderance of beneficial microorganisms involved in denitrification and phosphorus accumulation compared with activated sludge. The power consumption and sludge disposal cost were reduced by 34.7% and 54.9%, respectively, compared to the domestic SBR type sewage treatment plant with a processing capacity of 1,000 ㎥/d or less.

Manufacturing Procedure and Characteristic of Sintered Wick for Heat Pipe (히트파이프용 소결윅의 제작과정 및 특성)

  • Yun, Ho-Gyeong;Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.365-370
    • /
    • 2001
  • There are various wick types for heat pipe. In the present study, the manufacturing technology of a sintered wick among various wick types is discussed. The sintering technology using metal has been applied broadly in the field of electronic-telecommunication as well as heat pipes. A study of manufacturing procedure and characteristic of sintered wick for heat pipe have been performed. Copper powder was used as wick material and stainless steel as a mandrel. A manufacturing technology of the mandrel for arranging vapor core in heat pipe, a sintering technology by first or second times and operating temperature for sintering, the measurements of a porosity, pore size, and pore distribution of sintered wick were considered. In the meantime, a heat pipe with sintered wick has been manufactured and a performance test of the heat pipe has been performed in order to review cooling performance. The performance test results for the 4mm diameter heat pipe with the sintered wick shows the stability since the temperature difference between a evaporator and a condenser of the heat pipe is less than $4.4^{\circ}C$, and thermal resistance is less than $0.7^{\circ}C/W$.

  • PDF

Quantitative Comparison of Motion Artifacts in PET Images using Data-Based Gating (데이터 기반 게이팅을 이용한 PET 영상의 움직임 인공물의 정량적 비교)

  • Jin Young, Kim;Gye Hwan, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.91-98
    • /
    • 2023
  • PET is used effectively for biochemical or pathological phenomena, disease diagnosis, prognosis determination after treatment, and treatment planning because it can quantify physiological indicators in the human body by imaging the distribution of various biochemical substances. However, since respiratory motion artifacts may occur due to the movement of the diaphragm due to breathing, we would like to evaluate the practical effect by using the a device-less data-driven gated (DDG) technique called MotionFree with the phase-based gating correction method called Q.static scan mode. In this study, images of changes in moving distance (0 cm, 1 cm, 2 cm, 3 cm) are acquired using a breathing-simulated moving phantom. The diameters of the six spheres in the phantom are 10 mm, 13 mm, 17 mm, 22 mm, 28 mm, and 37 mm, respectively. According to maximum standardized uptake value (SUVmax) measurements, when DDG was applied based on the moving distance, the average SUVmax of the correction effect by the moving distance was improved by 1.92, 2.48, 3.23 and 3.00, respectively. When DDG was applied based on the diameter of the phantom spheres, the average SUVmax of the correction effect by the moving distance was improved by 2.37, 2.02, 1.44, 1.20, 0.42 and 0.52 respectively.

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

Reconstruction of Anterior Cruciate Ligament with Human Allograft (동종 이식건을 이용한 전방 십자 인대 재건술)

  • Suh Jeung-Tak;Cheon Sang-Jin;Lee Jung-Sub
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.1
    • /
    • pp.7-12
    • /
    • 2000
  • Purpose : The purpose of this study is to evaluate the clinical outcomes and radiological changes after reconstruction of anterior cruciate ligament with human allograft. Material and Method : Authors analyzed 22 cases of anterior cruciate ligament allograft reconstruction which were done from January, 1995 to December, 1998 and could be followed up for a year or more. All cases were followed and reviewed in terms of anterior drawer test, Lachman test, Pivot shift test, radiographic examination, knee range of motion, and side-to-side difference of anteroior tibial translation using CA-4000 knee motion analyzer, and Lysholm knee scoring system. Result : The mean Lysholm knee score was 54 preoperatively and improved to 81 postoperatively by average of 27. The side-to-side difference of anterior tibial translation using CA-4000 knee motion analyser was less than 3 mm in 16 cases$(73\%)$, between 3 and 5 mm in 4 cases$(18\%)$, and greater than 6 min in 2 cases$(9\%)$. Average tibial tunnel enlargement was 1.5 mm, but there were not any osteoiysis or cystic formation along the tunnel and no relationship between tunnel enlargement and clinical outcome. Conclusion : Although this study had limited cases, clinical results of anterior cruciate allograft reconstruction were similar to those of reconstruction with autograft reported in the literatures. We think that allograft is an acceptable substitute fer autograft in anterior cruciate ligament reconstruction.

  • PDF

Experience with Rastelli Procedure in the Repair of Congenital Heart Diseases (Rastelli 술식의 임상경험;72례)

  • 백희종
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1327-1336
    • /
    • 1992
  • Between Jan. 1986 and Aug. 1992. 72 patients underwent Rastelli procedure. There were 43 male and 29 female, aged 46 days to 16 years [mean age, 5.2 years] with 18 patients less than 2 years of age. All patients had complex defect, 27 pulmonary atresia with ventricular septal defect, 18 corrected transposition of great arteries with pulmonary atresia or punmonary stenosis, 10 truncus arteriosus, 10 double outlet right ventricle with pulmonary atresia or stenosis, 7 complete transposition of great artersia with pulmonary atresia or pulmonary stenosis. The types of extracardiac valved conduit used were prosthetic valve[n=47, 24 car-bomedics, 19 Ionescu-Shiley, 4 Bjork-shiley] and hand-made trileaflet valve using pericardium. [n=23, 20 bovine pericardium, Z autologous pericardium, 1 equine pericardium] The mean size of valved cinduit was 5.25mm larger in diameter than the size of main pulmonary artery. [normalized to the patient`s body surface area] There were 17 hospital death[24%] and 4 late deaths[5.6%]. Postoperative complication rate was 38.9%a, none of which was conduit-related. All patients were followed pos-toperatively for 1 to 73 months. [mean 25.8 months] During follow-up period, reoperation was done in 6 patients due to stenosis of valved conduit. Mean interval between intial repair and reoperation was 20.3 months. In our experience, li recently extracardaic valved conduits between right ventricle [or pulmonary ventricle] and pulmonary artery were inserted with increasing frequency in infants less than 2 year, but hospital mortality was decreased, 2] Risk of reoperation due to conduit stenosis is low, so that the effect of graft failure on overall survival is minimized. 3] Nevertheless, because any type of extracardaic valved conduit is not ideal in children, we recommended that Lecompte should be done if cardiac anatomy is permitted.

  • PDF