• Title/Summary/Keyword: 7T-MRI

Search Result 361, Processing Time 0.027 seconds

Dentofacial changes of non-orthodontically treated female patients with TMJ disk displacement: a longitudinal cephalometric study (교정 치료를 받지 않은 측두하악관절원반변위가 있는 여성 환자의 두부계측방사선사진을 이용한 안모 및 치열 변화 연구)

  • Han, Jung-Woo;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.398-410
    • /
    • 2010
  • Objective: The purpose of this study was to investigate the changes in dentofacial morphology of non-orthodontically treated female patients with TMJ disk displacement. Methods: The sample consisted of 25 Korean female patients with bilateral TMJ disk displacement who visited the Department of Orthodontics, Seoul National University Dental Hospital from 1996 to 2006. Disk displacements were diagnosed using the magnetic resonance imaging (MRI) of both TMJs. Baseline (T1) and follow-up (T2) lateral cephalograms were analyzed. The mean age of samples at T1 was $18.1{\pm}3.5$ years (range 14.2 - 25.8 years) and at T2, $21.1{\pm}3.5$ years (range 16.2 - 28.0 years). The mean observation period was $3.0{\pm}1.9$ years. Descriptive statistics for each variable were calculated at baseline (T1) and follow-up (T2) stages, and during the observation period (T2-T1). Results: Skeletal changes were found in 64% of the non-orthodontically treated female patients with TMJ disk displacement during the observation period. The L1 to Mandibular plane distance (mm) increased significantly by 0.8 mm (p < 0.01). But there were no significant differences in the other dental relationship variables (overjet, overbite, U1 to palatal plane) during the observation period. Most patients with skeletal changes showed a backward rotation of the mandible. The ratio of the rotation was a decrease of SNB by $0.43^{\circ}$ for every $1^{\circ}$ increase of FMA (Spearman rho = -0.660, P < 0.01). A few patients showed a distal shift of the mandible without rotation or significant changes in the vertical dimension. Conclusions: During observation periods without orthodontic treatment, non-growing patients with TMJ disk displacement showed dentoskeletal changes, mainly backward rotation of the mandible.

Role of Chemical Exchange Saturation Transfer and Magnetization Transfer MRI in Detecting Metabolic and Structural Changes of Renal Fibrosis in an Animal Model at 3T

  • Anqin Li;Chuou Xu;Ping Liang;Yao Hu;Yaqi Shen;Daoyu Hu;Zhen Li;Ihab R. Kamel
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.588-597
    • /
    • 2020
  • Objective: To investigate the value of combined chemical exchange saturation transfer (CEST) and conventional magnetization transfer imaging (MT) in detecting metabolic and structural changes of renal fibrosis in rats with unilateral ureteral obstruction (UUO) at 3T MRI. Materials and Methods: Thirty-five Sprague-Dawley rats underwent UUO surgery (n = 25) or sham surgery (n = 10). The obstructed and contralateral kidneys were evaluated on days 1, 3, 5, and 7 after surgery. After CEST and MT examinations, 18F-labeled fluoro-2-deoxyglucose positron emission tomography was performed to quantify glucose metabolism. Fibrosis was measured by histology and western blots. Correlations were compared between asymmetrical magnetization transfer ratio at 1.2 ppm (MTRasym(1.2ppm)) derived from CEST and maximum standard uptake value (SUVmax) and between magnetization transfer ratio (MTR) derived from MT and alpha-smooth muscle actin (α-SMA). Results: On days 3 and 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of contralateral kidneys (p < 0.05). On day 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of sham-operated kidneys (p < 0.05). The MTRasym(1.2ppm) of UUO renal medulla was fairly negatively correlated with SUVmax (r = -0.350, p = 0.021), whereas MTR of UUO renal medulla was strongly negatively correlated with α-SMA (r = -0.744, p < 0.001). Conclusion: CEST and MT could provide metabolic and structural information for comprehensive assessment of renal fibrosis in UUO rats in 3T MRI and may aid in clinical monitoring of renal fibrosis in patients with chronic kidney disease.

Transmit Receive RF Resonator Optimization at 7 T MRI System (7 T 자기공명영상시스템에서의 송수신 RF 공진기 최적화)

  • Alam, Mohammad Wajih;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1727-1730
    • /
    • 2016
  • Magnetic resonance imaging has a potential to produce clear anatomical as well as functional images of human body. However, the ability to diagnose is limited by signal to noise ratio (SNR) and the resolution of current medical systems. To remove the challenges prevalent due to the use of high field scanners, dedicated radio frequency coils are used. Transverse electromagnetic coils have an advantage of providing homogeneous magnetic field throughout the region but with low signal to noise ratio while surface coils have an advantage of providing higher signal to noise ratio but with low homogeneity. This research combines both the advantage into one by utilizing transmit only transverse electromagnetic radio frequency coils (8 channel) along with receive only surface coils (by varying the number) for better imaging of brain. A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

MRI Findings of COVID-19 Associated Acute Necrotizing Encephalopathy in Two Pediatric Patients: Case Report and Literature Review (소아에서 발생한 COVID-19 연관 급성 괴사성 뇌병증의 MRI 소견: 2건의 증례 보고 및 문헌 고찰)

  • Yoon Yeong Choi;Ha Young Lee;Myung Kwan Lim;Young Hye Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.682-690
    • /
    • 2024
  • Acute necrotizing encephalopathy (ANE) is a rare immune-mediated complication of a viral infection commonly involving the bilateral thalamus and has been reported mainly in children. Here, we describe the MRI findings of coronavirus disease 2019 (COVID-19)-associated ANE in two pediatric patients, including a 7-year-old girl with fever and mental change, and a 6-year-old girl with fever and generalized seizures. Brain MRI revealed symmetrical T2 fluid attenuated inversion recovery high-signal intensity lesions in the bilateral thalamus with central hemorrhage. In one patient, the thalamic lesions showed a tri-laminar pattern on the apparent diffusion coefficient map. This report emphasizes the importance of creating awareness regarding these findings in patients with COVID-19, particularly in children with severe neurological symptoms. Furthermore, it provides a literature review of several documented cases of COVID-19 presenting with bilateral thalamic hemorrhagic necrosis, suggesting a diagnosis of ANE.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

Differentiating Uterine Sarcoma From Atypical Leiomyoma on Preoperative Magnetic Resonance Imaging Using Logistic Regression Classifier: Added Value of Diffusion-Weighted Imaging-Based Quantitative Parameters

  • Hokun Kim;Sung Eun Rha;Yu Ri Shin;Eu Hyun Kim;Soo Youn Park;Su-Lim Lee;Ahwon Lee;Mee-Ran Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.1
    • /
    • pp.43-54
    • /
    • 2024
  • Objective: To evaluate the added value of diffusion-weighted imaging (DWI)-based quantitative parameters to distinguish uterine sarcomas from atypical leiomyomas on preoperative magnetic resonance imaging (MRI). Materials and Methods: A total of 138 patients (age, 43.7 ± 10.3 years) with uterine sarcoma (n = 44) and atypical leiomyoma (n = 94) were retrospectively collected from four institutions. The cohort was randomly divided into training (84/138, 60.0%) and validation (54/138, 40.0%) sets. Two independent readers evaluated six qualitative MRI features and two DWI-based quantitative parameters for each index tumor. Multivariable logistic regression was used to identify the relevant qualitative MRI features. Diagnostic classifiers based on qualitative MRI features alone and in combination with DWI-based quantitative parameters were developed using a logistic regression algorithm. The diagnostic performance of the classifiers was evaluated using a cross-table analysis and calculation of the area under the receiver operating characteristic curve (AUC). Results: Mean apparent diffusion coefficient value of uterine sarcoma was lower than that of atypical leiomyoma (mean ± standard deviation, 0.94 ± 0.30 10-3 mm2/s vs. 1.23 ± 0.25 10-3 mm2/s; P < 0.001), and the relative contrast ratio was higher in the uterine sarcoma (8.16 ± 2.94 vs. 4.19 ± 2.66; P < 0.001). Selected qualitative MRI features included ill-defined margin (adjusted odds ratio [aOR], 17.9; 95% confidence interval [CI], 1.41-503, P = 0.040), intratumoral hemorrhage (aOR, 27.3; 95% CI, 3.74-596, P = 0.006), and absence of T2 dark area (aOR, 83.5; 95% CI, 12.4-1916, P < 0.001). The classifier that combined qualitative MRI features and DWI-based quantitative parameters showed significantly better performance than without DWI-based parameters in the validation set (AUC, 0.92 vs. 0.78; P < 0.001). Conclusion: The addition of DWI-based quantitative parameters to qualitative MRI features improved the diagnostic performance of the logistic regression classifier in differentiating uterine sarcomas from atypical leiomyomas on preoperative MRI.

Brain activation pattern and functional connectivity network during classification on the living organisms

  • Byeon, Jung-Ho;Lee, Jun-Ki;Kwon, Yong-Ju
    • Journal of The Korean Association For Science Education
    • /
    • v.29 no.7
    • /
    • pp.751-758
    • /
    • 2009
  • The purpose of this study was to investigate brain activation pattern and functional connectivity network during classification on the biological phenomena. Twenty six right-handed healthy science teachers volunteered to be in the present study. To investigate participants' brain activities during the tasks, 3.0T fMRI system with the block experimental-design was used to measure BOLD signals of their brain. According to the analyzed data, superior, middle and inferior frontal gyrus, superior and inferior parietal lobule, fusiform gyrus, lingual gyrus, and bilateral cerebellum were significantly activated during participants' carrying-out classification. The network model was consisting of six nodes (ROIs) and its fourteen connections. These results suggested the notion that the activation and connections of these regions mean that classification is consist of two sub-network systems (top-down and bottom-up related) and it functioning reciprocally. These results enable the examination of the scientific classification process from the cognitive neuroscience perspective, and may be used as basic materials for developing a teaching-learning program for scientific classification such as brain-based science education curriculum in the science classrooms.

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study (게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백)

  • Kim, Taeho;Pooley, Robert;Lee, Danny;Keall, Paul;Lee, Rena;Kim, Siyong
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • The aim of the study is to test a hypothesis that quasi-breath-hold (QBH) biofeedback improves the residual respiratory motion management in gated 3D thoracic MR imaging, reducing respiratory motion artifacts with insignificant acquisition time alteration. To test the hypothesis five healthy human subjects underwent two gated MR imaging studies based on a T2 weighted SPACE MR pulse sequence using a respiratory navigator of a 3T Siemens MRI: one under free breathing and the other under QBH biofeedback breathing. The QBH biofeedback system utilized the external marker position on the abdomen obtained with an RPM system (Real-time Position Management, Varian) to audio-visually guide a human subject for 2s breath-hold at 90% exhalation position in each respiratory cycle. The improvement in the upper liver breath-hold motion reproducibility within the gating window using the QBH biofeedback system has been assessed for a group of volunteers. We assessed the residual respiratory motion management within the gating window and respiratory motion artifacts in 3D thoracic MRI both with/without QBH biofeedback. In addition, the RMSE (root mean square error) of abdominal displacement has been investigated. The QBH biofeedback reduced the residual upper liver motion within the gating window during MR acquisitions (~6 minutes) compared to that for free breathing, resulting in the reduction of respiratory motion artifacts in lung and liver of gated 3D thoracic MR images. The abdominal motion reduction in the gated window was consistent with the residual motion reduction of the diaphragm with QBH biofeedback. Consequently, average RMSE (root mean square error) of abdominal displacement obtained from the RPM has been also reduced from 2.0 mm of free breathing to 0.7 mm of QBH biofeedback breathing over the entire cycle (67% reduction, p-value=0.02) and from 1.7 mm of free breathing to 0.7 mm of QBH biofeedback breathing in the gated window (58% reduction, p-value=0.14). The average baseline drift obtained using a linear fit was reduced from 5.5 mm/min with free breathing to 0.6 mm/min (89% reduction, p-value=0.017) with QBH biofeedback. The study demonstrated that the QBH biofeedback improved the upper liver breath-hold motion reproducibility during the gated 3D thoracic MR imaging. This system can provide clinically applicable motion management of the internal anatomy for gated medical imaging as well as gated radiotherapy.