• Title/Summary/Keyword: 765kV

Search Result 258, Processing Time 0.036 seconds

Preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations (765kV 신가평, 신태백 변전소 예방진단시스템)

  • Kweon, D.J.;Shim, E.B.;Jung, G.J.;Kim, B.J.;Kim, J.H.;Yoo, Y.P.;Eun, J.Y.;Shin, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1694-1697
    • /
    • 2002
  • KEPCO is planing to adopt a preventive diagnostic system to obtain the reliability of transformer and GIS in 765kV substation. KEPRI has developed the preventive diagnostic system for 765kV substation since 1997. We used various sensors and fault detecting devices such as a dissolved gas analyzer in oil, a ultrasonic detector and LA leakage current detector, etc., and carried out adaptation tests at the both a laboratory and a site. We developed a data acquisition system, a communication control unit and a server system as well. Furthermore, monitoring program and diagnostic expert system were also developed. This paper describes the preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations which will be operated from 2004.

  • PDF

A Study on Multi-Phase Flashover in 765kV Transmission Line using EMTP (EMTP를 이용한 765kV 송전선로 다상 섬락에 관한 연구)

  • Ka, B.H.;Min, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1586-1588
    • /
    • 1998
  • To use the EMTP, in this paper, a arcing horn is simulated by non-linear resistor and inductor element using TACS, a tower by distributed parameter model, and lines as K. C. Lee model. Changing lightning current characteristics, lightning position, and tower footing resistor value, we analysis multi-phase flashover characteristics in 765 kV transmission line.

  • PDF

The Study on the Efficient HVDC Capacity Considering Extremely Low Probability of 765kV Double Circuit Transmission Lines Trip

  • Moon, Bong-Soo;Ko, Boyung;Choi, Jin-San
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1046-1052
    • /
    • 2017
  • The load on the power grid of South Korea is expected to grow continuously until the late 2020s, and it is necessary to increase the transfer capacity from the Eastern grid to the Seoul-Gyeonggi region by reinforcing the transmission network for the electric power system to remain stable. To this end, the grid reinforcement by two bipole LCC HVDC transmission systems have been considered on account of the public acceptability and high growth of the fault current level, even though an additional 765kV system construction is more economical. Since the probability of the existing 765kV double circuit transmission line trip is extremely low, a dynamic simulation study was carried out to estimate the efficient HVDC capacity able to stabilize the transient stability by utilizing the HVDC overload capability. This paper suggests the application plan to reduce the HVDC construction capacity with ensuring the transient stability during the 765kV line trip.

The design and the full load test results of 765kV tower foundation (765kV 철탑기초 설계 및 기초재하시험)

  • Kim, J.B.;Cho, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.447-449
    • /
    • 1995
  • In terms of a new development on the foundation design of 765kV tower and its applications, a revolutionary turning point comes out through this study in approaching the new concept, what we call "Rock anchor" "Deep foundation" to tower foundation which was officially approved by the full load test. this contents is described of the foundation design and the results of full load test for two types foundation.

  • PDF

Analysis on Induced Current Density Inside Human Body of Hot-Line Worker for 765kV Double Circuit Transmission Line (765 kV 2회선 송전선의 활선 작업자 인체내부 유도전류 밀도 해석)

  • Min, Suk-Won;Song, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.46-50
    • /
    • 2004
  • This paper analysed the induced current density inside human body of hot-line worker for 765kV double circuit transmission line according to locations of human body Human was modelled by several organs, which included brain, heart, lungs, liver and intestines. We applied the 3 dimensional boundary element method to calculate induced electric fields.

  • PDF

A study on the mechanical strength system and supporting method of insulator strings for KEPCO 765kV transmission lines (한전 765 kV 송전선로 애자장치 강도계열 및 지지방식에 관한 검토)

  • Han, Yup;Park, K.H.;Yoon, S.H.;Seo, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1920-1922
    • /
    • 1996
  • After determining the type and string condition of conductor of 765kV transmission lines, we studied the mechanical strength system of insulator strings to support conductors and insulate conductors from towers. In this paper, for the insulator strings which will be used in 765kV transmission lines, we're going to optimally determine the mechanical strength system and supporting method in the consideration of the reliability, economics and the survey data of T/L routes, and also suggest the calculation method to stipulate for the application limits of suspension and strain insulator strings according to the loadspan and height difference of tower.

  • PDF

Specification and performance test of the UHF PD sensor for GIS in 765 kV substations (765 kV 변전소 가스절연개폐장치(GIS)용 UHF 부분방전 센서의 규격과 성능측정)

  • Yoon, Jin-Yul;Park, Ki-Jun;Goo, Sun-Geun;Kim, Sung-Am;Ahn, Jung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1615-1617
    • /
    • 2003
  • 건설 중인 한국전력공사 765 kV 신태백 및 신가평변전소 GIS에 적용한 UHF 부분방전 센서의 사양을 제시하고 이에 대한 설명을 하였다. 또한 765 kV GIS에 센서를 취부하여 시험을 통해 센서의 주파수 특성시험과 감도 특성시험을 하였다. 아울러 센서성능을 측정하는 데에 필요한 장치와 회로를 보였고 시험결과를 이용하여 한전 사양을 충족시키는 방안을 제시하였다.

  • PDF

Seismic Response Spectrum Analysis of Gas Insulated Switchgear for 765kV Substation (765kV 가스절연 개폐장치의 지진응답스펙트럼 해석)

  • Hwang, Kyeong-Min;Jang, Jung-Bum;Kim, Jeong-Kim;Suh, Yong-Pyo;Lee, Guen-Jig
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.347-348
    • /
    • 2007
  • 최근 한반도 및 그 주변에 중소규모 이상의 지진이 빈번히 발생하고 있으나, 국내 대부분의 변전설비들은 내진설계개념을 적용하지 못하고 있는 실정이다. 특히 765kV 변전설비는 산업적, 경제적으로 중요한 국가설비이므로 전력공급 중단을 막기 위해 내진성능확보가 필수적이다. 따라서, 본 연구에서는 765kV 변전소 내 대표설비인 가스절연 개폐장치를 대상으로 내진성능평가를 수행하였으며, 그 결과 지진에 일부 취약한 부위가 발견되어 내진성능개선을 위한 보강이 필요한 것으로 나타났다.

  • PDF

A study on the design of conductor stringing for KEPCO 765kV Transmission Lines (한전 765 kV 송전선로 전선가선설계에 관한 검토)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1330-1331
    • /
    • 1995
  • This paper deals with the design of conductor stringing of KEPCO 765kV transmission line. The main subject in the design of conductor stringing is the determination on what the stringing tension is. According to the stringing tension, the weight and height of towers and the strength necessary for conductor, hardware, insulator vary, and the construction cost and the reliability of tower are affected largely. Therefore, in order to determine the optimum condition for stringing conductors, We appraised various items : estimation of economic comparision, strength appraisal of conductor, hardware, insulator, etc. After studying these entirely, we present the condition of condutor stringing for KEPCO 765kV transmission line.

  • PDF

Analysis of Surge Voltage according to Fault Inception Angle in 765kV transmission System (765kV 송전계통에서 고장 발생각에 따른 서지 분석)

  • Moon, Ji-Young;Lee, You-Jin;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2233_2234
    • /
    • 2009
  • 낙뢰 또는 수목 접촉 등의 일시적인 사고가 발생하면 계통내 접촉 위치에 순간적으로 아크 현상이 일어나게 된다. 일시 고장 원일을 제거하기 위해 기계적으로 전기의 흐름을 단절시켜 고장 원인을 제거하고, 재투입을 통해 계통 복구를 할 수 있다. 아크는 음극과 양극 사이의 방전으로 인한 플라즈마로 설명될 수 있는데 전력 계통에서는 저항으로서 취급할 수 있다. 본 논문에서는 765kV 모델 계통의 아크 현상 시뮬레이션을 통해 고장각 발생 변화에 따른 아크 전압 특성을 분석할 것이다. 또한 아크 특성 분석을 통해 우리는 아크 발생 시 전력 계통에 미치는 영향을 파악하고 분석하고자 한다. 본 논문에서 전력 계통의 과도현상 분석 프로그램인 EMTP(Electro Magnetic Transient Program)를 이용하여 아크현상에 대한 분석 및 765kV계통에서의 아크 고장을 시뮬레이션 하였다.

  • PDF