• 제목/요약/키워드: 76-story benchmark problem

검색결과 6건 처리시간 0.025초

풍하중 구현 및 내풍특성 평가를 위한 선형질량 가진시스템 설계 (Design of a Linear Mass Excitation System for Simulating Wind-induced Responses of a Building Structure)

  • 박은천;이상현;민경원;강경수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.661-668
    • /
    • 2007
  • In this paper, excitation systems using linear mass shaker (LMS) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop function are used such that the error between the wind and actuator induced responses is minimized by preventing the actuator from exciting unexpected modal response and initial transient response. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

  • PDF

ATMD를 이용한 건축 구조물의 풍응답 구현을 위한 가진시스템 (Excitation System for Simulating Wind-induced Responses of a Building Structure using an Active Tuned Mass Damper)

  • 박은천;이상현;민경원;강경수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.210-215
    • /
    • 2007
  • In this paper, excitation systems using an active tuned mass damper (ATMD) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

  • PDF

건축구조물의 풍하중 구현 및 풍특성 평가를 위한 가진시스템 설계 (Design of an Excitation System for Simulating Wind-Induced Response and Evaluating Wind-load Resistance Characteristics)

  • 박은천;이성경;민경원;정란;강경수;이상현
    • 한국전산구조공학회논문집
    • /
    • 제20권6호
    • /
    • pp.769-778
    • /
    • 2007
  • 본 논문에서 건축구조물의 풍응답 구현을 위한 선형질량가진기(linear mass shaker, LMS)와 능동동조질량감쇠기(active tuned mass damper, ATMD)를 이용한 가진시스템을 제안한다. 가진시스템을 위한 가진기의 힘은 가진기에 의한 구조물의 목표응답의 전달함수를 사용하여 계산된다. 필터와 포락곡선함수는 예측하지 못한 모드응답에 의한 가진과 초기 과도응답을 제거함으로써 실제 바람에 의한 응답과 가진기에 의한 응답의 오차를 최소화하기 위하여 사용되었다. 수치예제로는 풍동실험을 통한 풍하중이 주어진 76층 벤치마크 구조물을 이용하여 수치해석을 수행하였으며, 그 결과는 특정층에 설치된 가진시스템은 풍하중이 전층에 가진되었을 때의 응답을 근사하게 구현할 수 있음을 보여준다. 제안된 방법에 의해 설계된 가진시스템은 실제 건축구조물의 풍응답 특성을 평가하는데, 그리고 풍하중을 받는 건물의 정확한 수치모델을 얻는데 효과적으로 사용될 수 있다.

외란 예측기가 포함된 슬라이딩 모드 퍼지 제어기의 응용 (Application of Sliding Mode fuzzy Control with Disturbance Prediction)

  • 김상범;윤정방;구자인
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.365-370
    • /
    • 2000
  • A sliding mode fuzzy control (SMFC) algorithm is applied to design a controller for a benchmark problem on a wind- excited building. The structure is a 76-story concrete office tower with a height of 306 meters, hence the wind resistance characteristics are very important for the serviceability as well as the safety. A control system with an active tuned mass damper is assumed to be installed on the top floor. Since the structural acceleration is measured only at ,limited number of locations without measurement of the wind force, the structure of the conventional continuous sliding mode control may have the feed-back loop only. So, an adaptive least mean squares (LMS) filter is employed in the SMFC algorithm to generate a fictitious feed-forward loop. The adaptive LMS filter is designed based on the information of the stochastic characteristics of the wind velocity along the structure. A numerical study is carried out. and the performance of the present SMFC with the ,adaptive LMS filter is investigated in comparison with those of' other control, of algorithms such as linear quadratic Gaussian control, frequency domain optimal control, quadratic stability control, continuous sliding mode control, and H/sub ∞///sub μ/, control, which were reported by other researchers. The effectiveness of the adaptive LMS filter is also examined. The results indicate that the present algorithm is very efficient .

  • PDF

Design of an actuator for simulating wind-induced response of a building structure

  • Park, Eun Churn;Lee, Sang-Hyun;Min, Kyung-Won;Chung, Lan;Lee, Sung-Kyung;Cho, Seung-Ho;Yu, Eunjong;Kang, Kyung-Soo
    • Smart Structures and Systems
    • /
    • 제4권1호
    • /
    • pp.85-98
    • /
    • 2008
  • In this paper, excitation systems using a linear mass shaker (LMS) and an active tuned mass damper (ATMD) are presented to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop functions are used to prevent the actuator from exciting unexpected modal responses and an initial transient response and thus, to minimize the error between the wind and actuator induced responses. The analyses results from a 76-story benchmark building problem for which the wind load obtained by a wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately reproduce the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

Wind-Induced Vibration Control of a Tall Building Using Magneto-Rheological Dampers: A Feasibility Study

  • Gu, Ja-In;Kim, Saang-Bum;Yun, Chung-Bang;Kim, Yun-Seok
    • Computational Structural Engineering : An International Journal
    • /
    • 제3권1호
    • /
    • pp.61-68
    • /
    • 2003
  • A recently developed semi-active control system employing magneto-rheological (MR) fluid dampers is applied to vibration control of a wind excited tall building. The semi-active control system with MR fluid dampers appears to have the reliability of passive control devices and the adaptability of fully active control systems. The system requires only small power source, which is critical during severe events, when the main power source may fail. Numerical simulation studies are performed to demonstrate the efficiency of the MR dampers on the third ASCE benchmark problem. Multiple MR dampers are assumed to be installed in the 76-story building. Genetic algorithm is applied to determine the optimal locations and capacities of the MR dampers. Clipped optimal controller is designed to control the MR dampers based on the acceleration feedback. To verify the robustness with respect to the variation of the external wind force, several cases with different wind forces are considered in the numerical simulation. Simulation results show that the semi-actively controlled MR dampers can effectively reduce both the peak and RMS responses the tall building under various wind force conditions. The control performance of the MR dampers for wind is found to be fairly similar to the performance of an active tuned mass damper.

  • PDF