• 제목/요약/키워드: 6MV linear accelerator

검색결과 188건 처리시간 0.021초

6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포 (Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator)

  • 윤주호;이철수;염하용
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

뇌동정맥기형 26예의 선형가속기를 이용한 뇌정위다방향 단일방사선치료 (Stereotactic Radiosurgery of 26 Intracranial Arteriovenous Malformations with Linear Accelerator)

  • 윤세철;서태석;장홍석;최규호;김문찬;신경섭;박용휘
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.21-26
    • /
    • 1992
  • 가톨릭의대 강남성모병원 치료방사선과에서는 1988년 7월부터 1991년 11월 사이 40개월 동안에 26명의 수술 불가능한 뇌동정맥기형 환자에 대하여 6 MV선형가속기를 이용하여 뇌정위다방향 단일 방사선치료를 실시하였다. 환자연령은 6세부터 63세였고(중앙값 29세), 남녀의 비는 21:5였다. 치료 종료 후 추적기간은 4개월$\~$40개월 간이었다(중앙값 15개월). 뇌동정맥기형의 크기는 직경 1 cm부터 $43cm^3$까지였으며 환자 연영, 병소의 크기 및 뇌내 위치에 따라 4$\~$7회의 부분회전 조사를 실시하여 15$\~$30 Gy를 단일 조사하였다. 모든 환자는 임상적 그리고 CT또는 MRI나 뇌혈관조영술을 병행하여 방사선치료 전 및 후 6개월간격으로 뇌동정맥기형의 크기변화를 추적 분석하였다. 2년 이상된 예의 추적 검사를 분석한 결과 완전 관해 6($23\%$), 부분관해 8($31\%$), 무변화 1($4\%$)명 씩으로 분석되었다. 11($42\%$)명은 방사선치료한지 1년 미만의 무반응군으로 간주되었다. 이상으로 치료후 2년째 반응율은 $54\%$(14예)였다. 치료에 따른 부작용은 아직 관찰되지 않았다.

  • PDF

Improvement of accuracy in radioactivity assessment of medical linear accelerator through self-absorption correction in HPGe detector

  • Suah Yu;Na Hye Kwon;Sang-Rok Kim;Young Jin Won;Kum Bae Kim;Se Byeong Lee;Cheol Ha Baek;Sang Hyoun Choi
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2317-2323
    • /
    • 2024
  • Medical linear accelerators with an energy of 8 MV or higher are radiated owing to photonuclear reactions and neutron capture reactions. It is necessary to quantitatively evaluate the concentration of radioactive isotopes when replacing or disposing them. HPGe detectors are commonly used to identify isotopes and measure radioactivity. However, because the detection efficiency is generally calibrated using a standard material with a density of 1.0 g/cm3, a self-absorption effect occurs if the density of the measured material is high. In this study, self-absorption correction factors were calculated for tungsten, lead, copper, and SUS-303, which are the main materials of medical linear accelerator head parts, for each gamma-ray energy using MCNP 6.2 code. The self-absorption effect was more pronounced as the energy of the emitted gamma rays decreased and the density of the measured materials increased. These correction factors were applied to the radioactivity measurements of the in-built and portable HPGe detectors. Furthermore, compared to the surface dose rate measured by the survey meter, the accuracy of the measurements of radioactivity improved by an average of 124.31 and 100.53 % for inbuilt and portable HPGe detectors, respectively. The results showed a good agreement, with an average difference of 3.70 and 5.24 %.

Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

  • Hwajung Lee;Do Hoon Oh;Lee Yoo;Minsoo Chun
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.100-106
    • /
    • 2023
  • Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation. Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR. Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs. Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes' own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

상용 의학용 X-ray 필름의 특성곡선 (The Characteristic Curves of Commercial Medical X-ray Films)

  • 허훈;정연태;이재성
    • 한국인쇄학회지
    • /
    • 제19권2호
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

Philips LINAC 6 MV와 8 MV X선 소조사연에 대한 선량분포 측정 (Measurement of Dose Distribution in Small Beams of Philips 6 and 8 MVX Linear Accelerator)

  • 서태석;윤세철;신경섭;박용휘
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.143-152
    • /
    • 1991
  • 본 논문에서는 소조사면에 대한 X-선의 선량분포를 일반실험식으로 계산될 수 있도록 beam 측정 데이타를 종합 처리하는 방법에 대하여 기술하고 있다. Beam 데이타는 philips LINAC 6 MV, 8 MV X-ray에 대하여 측정 되었으며, 측정된 요소는 tissue maximum ratio (TMR), off-axis-ratio (OAH), 그리고 relative output factor (ROF)를 포함한다. 소조사면에 의한 방사선 치료를 위하여 isocenter에서 지름이 1 내지 3cm되도록 실린더 형태의 특수 collimator가 2 mm 간격으로 제작되었다. 본 측정을 위하여 다이오드 detector가 이용되었으며 Film 및 TLO 측정기로 측정된 값과 비교검토 되었다. 제한된 조사면으로 측정된 TMR, OAR data로부터 beam 데이타를 나타내는 실험식을 유도하였으며 이 실험식은 임의의 Set-UP조건에 따른 측정값을 예상할 수 있는 일반 실험식으로 확장되었고 측정된 TMR과 OAR 값들은 잘 일치되었다.

  • PDF

CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가 (The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$)

  • 조한상;남상수;박혜진;김미화;박안태
    • 대한방사선치료학회지
    • /
    • 제23권1호
    • /
    • pp.51-58
    • /
    • 2011
  • 목 적: 본 연구에서는 본원에서 보유하고 있는 선형가속기 Clinac IX과 21EX (Varian, Palo Alto, CA)에 대하여 2008년부터 2010년까지 CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL)를 이용하여 측정한 일일 출력 값을 바탕으로 절대 선량에 대한 오차 범위를 평가함으로써 그 유용성을 확인하고자 하였다. 대상 및 방법: 일일 정도 관리는 Varian사의 21EX, IX 두 대의 선형가속기의 광자선(6 MV, 10 MV)을 대상으로 매일 치료시작 전 CHECKMATE$^{TM}$를 사용하여 측정되었고, 절대선량은 격주간격으로 물 팬텀을 이용하여 측정되었다. 21EX의 경우 2008년부터 2010년, IX는 2009년부터 2010년까지의 일일 정도 관리의 측정치와 절대선량 측정치의 데이터 값을 분석하였다. 각 데이터는 Excel 2007 (Microsoft, USA)을 이용하여 평균, 표준편차, 신뢰수준을 평가하였고, CHECKMATE$^{TM}$의 측정값과 절대선량의 유의성을 확인하기 위하여 각 데이터의 오차 값을 각각 비교 분석하였다. 결 과: 관찰 기간 동안 두 장비의 절대선량의 출력은 시간이 지남에 따라 점차 증가함을 보였고, 이 증가는 6 MV와 10 MV 두 에너지 모두에서 비슷한 양의 증가 추세를 보이고 있었다. 또한 CHECKMATE$^{TM}$의 측정치와 절대선량 값의 오차율은 모두 0.34 이하로 나타나 두 측정값이 서로 유의관계가 있음을 보였다. CHECKMATE$^{TM}$ 측정값이 상향됨을 확인 후 이를 조정하기 위하여 절대선량 측정하였고, 오차범위 2~3%에 근접한 경우 출력 값을 교정한 횟수는 21EX는 4회, IX는 3회였다. 결 론: CHECKMATE$^{TM}$를 이용하여 2년 동안 일일 출력 변화를 측정하고 분석한 결과, 품질 관리 시 준수해야 하는 출력 값이 허용 오차 범위 2~3% 내에서 절대선량의 측정값들과 유의성이 있음을 보였다. 따라서 선형가속기의 보다 효율적이며 신뢰도가 있는 일일 출력 검증을 위하여, CHECKMATE$^{TM}$의 사용을 고려할 수 있다. 또한 각 기관에서의 선형가속기 출력 값의 변화 추세를 파악하고 각 출력 값 교정에 참고할 수 있는 좋은 기준이 될 수 있다고 사료된다.

  • PDF

Dosimetric Comparison of 6 MV Flattening Filter Free and 6 MV Stereotactic Radiosurgery Beam Using 4 mm Conical Collimator for Trigeminal Neuralgia Radiosurgery

  • Mhatre, Vaibhav R;Chadha, Pranav;Kumar, Abhaya P;Talapatra, Kaustav
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.107-113
    • /
    • 2018
  • Background: The purpose of our study was to compare the dosimetric advantages of Flattening filter free (FFF) beams for trigeminal neuralgia patients using 4 mm conical collimators over previously treated patients with 6 MV SRS beam. Materials and Methods: A retrospective study was conducted for 5 TN patients who had been previously treated at our institution using frame-based, LINAC-based stereotactic radiosurgery (SRS) on Novalis Tx using 6 MV SRS beam were replanned on 6X FFF beams on Edge Linear accelerator with same beam angles and dose constraints using 4 mm conical collimator. The total number of monitor units along with the beam on time was compared for both Edge and Novalis Tx by redelivering the plans in QA mode of LINAC to compare the delivery efficiency. Plan quality was evaluated by homogeneity index (HI) and Paddick gradient index (GI) for each plan. We also analyzed the doses to brainstem and organ at risks (OARs). Results and Discussion: A 28% beam-on time reduction was achieved using 6X FFF when compared with 6X SRS beam of Novalis Tx. A sharp dose fall off with gradient index value of $3.4{\pm}0.27$ for 4 mm Varian conical collimator while $4.17{\pm}0.20$ with BrainLab cone. Among the 5 patients treated with a 4 mm cone, average maximum brainstem dose was 10.24 Gy for Edge using 6X FFF and 14.28 Gy for Novalis Tx using 6X SRS beam. Conclusion: The use of FFF beams improves delivery efficiency and conical collimator reduces dose to OAR's for TN radiosurgery. Further investigation is warranted with larger sample patient data.

선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석 (Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator)

  • 구기래;양오남;임청환;최원식;신성수;안우상
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.265-273
    • /
    • 2012
  • 선형가속기를 기반으로 하는 세기조절방사선치료와 정위적방사선수술에서는 치료계획시스템의 소조사면에 대한 신뢰할만한 선량분포를 계산하기 위해서는 우선적으로 소조사면의 정확한 빔 자료 측정이 선행되어야 한다. 특히 소조사면의 빔 자료 측정에서 조사면 가장자리에서의 급격한 선량 변화, 측면 전자비평형, 그리고 검출기의 체적 영향으로 인한 적절한 검출기 선택이 중요하다. 따라서 본 연구에서는 선형가속기의 소조사면에 대한 빔 자료 측정에 있어서 검출기의 선량 특성을 알아보고자 하였다. 검출기는 0.01 cc 부피와 0.13 cc 부피의 이온전리함과 정위적다이오드를 사용하였으며, 빔 자료는 광자선(6 MV와 15 MV)에 대하여 조사면 크기를 $2{\times}2cm^2$에서 $5{\times}5cm^2$까지 변화시켜 각 검출기를 이용하여 깊이선량백분율, 선량출력계수, 그리고 빔측면도를 측정하였다. CC01 이온전리함과 정위적다이오드 검출기를 이용한 $PDD_{20}/PDD_{10}$$2{\times}2cm^2$ 조사면의 경우 6 MV와 15 MV에서 각각 1.02%와 0.12% 차이를 보였다. $3{\times}3cm^2$ 이상의 조사면에서는 각 검출기를 이용하여 얻어진 $PDD_{20}/PDD_{10}$의 차이가 6 MV와 15 MV에서 각각 평균 1.15%와 0.71% 이였다. CC01 이온전리함과 정위적다이오드 검출기를 이용한 선량출력계수 측정 결과, $2{\times}2cm^2$ 조사면의 경우 6 MV와 15 MV에서 0.5%와 1.5%이내에서 일치하였다. $3{\times}3cm^2$ 이상의 조사면에서는 각 검출기의 차이가 0.5% 이내이였다. 3개의 깊이에서 측정된 빔측면도의 반음영은 정위적다이오드 검출기의 경우 6 MV와 15 MV에서 각각 평균 2.7 mm와 3.5 mm, CC01 이온전리함의 경우 각각 평균 3.4 mm와 4.3 mm, CC13 이온전리함의 경우 각각 평균 5.2 mm와 6.1 mm이였다. 이를 통해 깊이선량백분율과 선량출력계수 측정 시 $2{\times}2cm^2$ 조사면에서는 CC01 이온전리함과 정위적다이오드 검출기를 $3{\times}3cm^2$에서 $5{\times}5cm^2$ 조사면에서는 각 검출기의 사용이 가능할 것으로 판단된다. 또한 소조사면에 대한 정확한 빔측면도의 반음영을 측정하기 위해서는 유효체적이 작은 CC01 이온전리함과 정위적다이오드 검출기 사용하는 것이 타당하겠다.