• 제목/요약/키워드: 6LiF

검색결과 410건 처리시간 0.026초

리튬 2차전지용 양극소재 $LiFePO_4/C$의 합성 및 리트벨트 구조분석 (Synthesis and Rietveld Refinement of the Cathode Material $LiFePO_4/C$ for Rechargeable Lithium Batteries)

  • 황길찬;최진범;김재광;안주현
    • 한국광물학회지
    • /
    • 제22권1호
    • /
    • pp.63-72
    • /
    • 2009
  • 개량된 MA법으로 합성된 $LiFe(PO_4)/C$에 대해 X-선 회절분석을 실시하여 리트벨트법에 의해 결정학적 연구를 수행하였다. 리트벨트 계산 결과 리트벨트 R 지수 값은 $R_p=8.14%,\;R_{wp}=11.1%,\;R_{exp}=9.09%,\;R_B=3.88%$, S (GofF, Goodness of fit) = 1.2으로 계산이 잘 이루어졌음을 알 수 있다. $LiFePO_4/C$는 공간군 Pnma를 가지며, 격자상수 값은 a = 10.3229(3)${\AA}$, b = 6.0052(2) ${\AA}$, c = 4.6939(1) ${\AA}$이고 체적값은 V = 290.98(1) ${\AA}^3$으로 기존 다른 합성법의 연구결과와 잘 일치한다. 분말 입자는 고순도를 가지고 나노 크기($65{\sim}90nm$)로 기존 MA법보다 상대적으로 미세하고 균질도가 향상되었다. 따라서 개량된 MA법은 상업용 리튬 2차 전지의 양극물질 생산을 위한 우수한 제조법으로 판단된다.

흡수선량지수결정(吸收線量指數決定)에 관한 실험적(實驗的) 연구(硏究) (Experimental Study on the Determination of Absorbed dose Index)

  • 전재식;노재식;노성기;하정우;유영수;이현덕
    • Journal of Radiation Protection and Research
    • /
    • 제7권1호
    • /
    • pp.34-48
    • /
    • 1982
  • 본 연구의 일차적 목적은 방사선 방호를 위하여 임의지점(任意地點)의 주변 방사선량의 수준을 특성(特性)짓는 방법의 하나로 ICRU가 정의(定義)한 흡수선량지수를 실측(實測)하는데 있는 바 이를 위한 실험은 에비실험과 본 실험의 두 단계로 나누어 수행하였다. 예비단계의 실험에서는 30cm 지름의 polyethylene구(球)를 사용한 반면 본 실험에서는 인체조직등가물질(人體組織等價物質)의 구(球)를 제작하였으며 두 실험 모두 $^{137}Cs$$^{60}Co$ 감마선장(線場)과 TRIGA Mark-II 원자로의 열중성자(熱中性子) column의 중성자공장(中性子工場)에서 행하여졌다. 감마선 흡수선량측정에는 TCD-700 $(^{7}LiF)$ chip을, 중성자선량측정에는 Au 방사화박(放射化薄)과 함께 TLD chip도 사용하였는데 이 경우에는 감마선의 기여를 판별해 내기 위하여 TLD-600 $(^{6}LiF)$과 TLD-700을 동시에 사용하였다. 감마선 조사(照射)의 경우 구(球) phantom내(內) 흡수선량의 이론적 해석은 Burlin의 공동이론(空洞理論)에서 유도된 Erlich의 방법을 썼으며, 중성자 선량해석에는 fluence-KERMA 변환방법을 사용하였다. 이들 선량에 관하여서는 특히 자세히 설명하였다. 해석에 실험결과는 모두 통계적으로 처리 분석하였으며 특히 심부선량분포(深部線量分布)는 규격화(規格化)한 값을 사용하여 도표(圖表)로 나타내는 한편, 결론에서는 방사선방호용 지수량(指數量) 실측(實測)의 가능성과 난점(難點)을 설명하고 해결하여야 할 문제점들을 언급(言及)하였다.

  • PDF

A prototype of the SiPM readout scintillator neutron detector for the engineering material diffractometer of CSNS

  • Yu, Qian;Tang, Bin;Huang, Chang;Wei, Yadong;Chen, Shaojia;Qiu, Lin;Wang, Xiuku;Xu, Hong;Sun, Zhijia;Wei, Guangyou;Tang, Mengjiao
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1030-1036
    • /
    • 2022
  • A high detection efficiency thermal neutron detector based on the 6LiF/ZnS(Ag) scintillation screens, wavelength-shifting fibers (WLSF) and Silicon photomultiplier (SiPM) readout is under development at China Spallation Neutron Source (CSNS) for the Engineering Material Diffractometer (EMD).A prototype with a sensitive volume of 180mm×192mm has been built. Signals from SiPMs are processed by the self-design Application Specific Integrated Circuit (ASIC). The performances of this detector prototype are as follows: neutron detection efficiency could reach 50.5% at 1 Å, position resolution of 3, the dark count rate <0.1Hz, the maximum count rate >200KHz. Such detector prototype could be an elementary unit for applications in the EMD detector arrays.

고성능 리튬 이온전지를 위한 폴리머-세라믹 복합 겔 고분자 전해질 (Polymer-Ceramic Composite Gel Polymer Electrolyte for High-Electrochemical-Performance Lithium-Ion Batteries)

  • 장소현;김재광
    • 전기화학회지
    • /
    • 제19권4호
    • /
    • pp.123-128
    • /
    • 2016
  • 본 연구에서는 poly(vinylidene fluoride-co-hexafluoropropylene) (PVdF-HFP)를 나노 크기의 $Al_2O_3$ 세라믹입자와 혼합하여 전기방사법으로 복합 겔 고분자 전해질을 제조하였다. $Al_2O_3$ 세라믹입자를 혼합한 복합 겔 고분자 전해질의 이온전도도는 $9.5{\times}10^{-2}Scm^{-1}$로, 순수한 PVdF-HFP 겔 고분자 전해질보다 높은 이온전도도를 나타내며 전기화학적 안정성도 5.2 V까지 개선하였다. 전기화학적 성능을 분석하기 위해서 $LiNi_{1/3}Mn_{1/3}Co_{1/3}O_2$ (NMC)양극과 함께 전지로 제작되었으며 순수 겔 고분자 전해질과 복합 겔 고분자 전해질 셀은 0.1C-rate에서 각각 $168.2mAh\;g^{-1}$$189.6mAh\;g^{-1}$의 방전 용량을 가지며 우수한 수명 특성을 보여 주었다. 따라서 고유전율 세라믹 입자의 복합화는 리튬 이온 겔 고분자 전지의 안정성과 전기화학적 특성을 향상시키는 좋은 대안이 될 것으로 판단된다.

Ca[Ti1-x(Ni1/3Nb2/3)x]O3 세라믹스의 저온소결 및 마이크로파 유전특성 (Low Temperature Sintering and Microwave Dielectric Properties of Ca[Ti1-x(Ni1/3Nb2/3)x]O3 Ceramics)

  • 이영규;김효태;남중희;김종희;백운규
    • 한국세라믹학회지
    • /
    • 제43권1호
    • /
    • pp.55-61
    • /
    • 2006
  • The microwave dielectric properties and low temperature sintering of $Ca[Ti_{1-x}(Ni_{1/3}Nb_{2/3})_x]O_3$ system were investigated at the sintering temperature $1,200\~1,350^{\circ}C$. The density and quality factors $(Q{\times}f)$ increased while dielectric constants slightly decreased with the decrease of Ti. The dielectric constant, quality factor, and temperature coefficient of resonance frequency $(\tau_f)$ were 64, 17,000 GHz, and $-9.1\;ppm/^{\circ}C$ respectively, when $CaTi_{1/2}(Ni_{1/3}Nb_{2/3})_{1/2}O_3$ ceramics were sintered at $1,300^{\circ}C$ for 4 h. $2Li_2O-B_2O_3$ was added to $CaTi_{1/2}(Ni_{1/3}Nb_{2/3})_{1/2}O_3$ to decrease the sintering temperature for LTCC application. The microwave dielectric properties of the samples sintered at $925^{\circ}C$ for 2 h with the addition of $6\;wt\%\;2Li_2O-B_2O_3$ were $\varepsilon_r=48.7,\;Q{\times}f=8,460\;GHz$, and $\tau_f=+5.6ppm/^{\circ}C$. Compatibility test of the composition with silver electrode shows no reaction with silver electrode, implying the feasibility as a high-K LTCC material.

Diagnostic Value of 18F-FDG PET/CT in Comparison to Bone Scintigraphy, CT and 18F-FDG PET for the Detection of Bone Metastasis

  • Liu, Ning-Bo;Zhu, Lei;Li, Ming-Huan;Sun, Xiao-Rong;Hu, Man;Huo, Zong-Wei;Xu, Wen-Gui;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권6호
    • /
    • pp.3647-3652
    • /
    • 2013
  • Purpose: To evaluate the diagnostic value of $^{18}F$-FDG PET/CT for detection of bone metastasis in comparison with the efficacies of $^{18}F$-FDG PET/CT, CT, $^{18}F$-FDG PET and conventional planar bone scintigraphy in a series of cancer patients. Methods: Five hundred and thirty patients who underwent both $^{18}F$-FDG PET/CT and bone scintigraphy within 1 month were retrospectively analyzed. The skeletal system was classified into 10 anatomic segments and interpreted blindly and separately. For each modality, the sensitivity, specificity, accuracy, PPV and NPV were calculated and the results were statistically analyzed. Results: Bone metastases were confirmed in 117 patients with 459 positive segments. On patient-based analysis, the sensitivity, specificity, accuracy, PPV and NPV of $^{18}F$-FDG PET/CT were significantly higher than bone scintigraphy, CT and $^{18}F$-FDG PET (P<0.05). On segment-based analysis, the sensitivity of CT, bone scintigraphy, $^{18}F$-FDG PET and $^{18}F$-FDG PET/CT were 70.4%, 89.5%, 89.1% and 97.8%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The overall specificity and accuracy of the four modalities were 89.1%, 91.8%, 90.3%, 98.2% and 90.3%, 90.9%, 89.8%, 98.0%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The PPV and NPV were 89.8%, 87.6%, 85.6%, 97.2% and 85.6%, 93.2%, 92.8%, 98.6%, respectively. Three hundred and twelve lesions or segments were presented as lytic or sclerotic changes on CT images at the corresponding sites of increased $^{18}F$-FDG uptake. In lytic or mixed lesions, the sensitivity of $^{18}F$-FDG PET/CT and $^{18}F$-FDG PET were better than bone scintigraphy, while in osteoblastic lesions bone scintigraphy had a similar performance with $^{18}F$-FDG PET/CT but better than $^{18}F$-FDG PET alone. Conclusion: Our data allow the conclusion that $^{18}F$-FDG PET/CT is superior to planar bone scintigraphy, CT or $^{18}F$-FDG PET in detecting bone metastasis. $^{18}F$-FDG PET/CT may enhance our diagnosis of tumor bone metastasis and provide more information for cancer treatment.

F4-TCNQ를 이용한 유기 발광 소자의 전기적 특성 변화

  • 나수환;김태완;장경욱;한원근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.166-167
    • /
    • 2009
  • 본 연구에서는 2,3,5,6-fluoro-7,7,8,8-tetracyanoquinodimethane (F4-TCNQ)를 이용한 유기 발광 소자의 전기적 특성에 대하여 연구하였다. F4-TCNQ 는 높은 전자 친화도를 가지고 있어서 전하 수송층이나 전하 주입층에 많이 사용되고 있다. 또한 TCNQ 유도체들은 물질의 전도도를 조절하는 용도로 많이 이용된다. TCNQ 유도체를 유기 발광 소자의 전하 수송층이나 전하 주입층에 이용할 경우, 소자의 구동 전압이나 효율과 같은 특성들이 향상된다고 알려져 있다. 우리는 소자 특성에 있어서 F4-TCNQ의 영향을 알아보기 위해서 ITO(170nm)/TPD(40nm)/$Alq_3$(60nm)/LiF(0.5nm)/Al(100nm)의 구조로 기본 소자를 제작하였다. 그리고 TPD층에 F4-TCNQ를 도핑하여 소자를 제작하였다. 도핑 농도는 5와 10%로 하였다. 또한 ITO와 TPD층 사이에 F4-TCNQ층을 1, 2, 그리고 5nm의 두께로 하여 소자를 제작하였다. F4-TCNQ를 5와 10% 도핑한 소자의 구동 전압은 도핑하지 않은 소자에 비해 감소하였다. 그리고, ITO와 유기물층 사이에 F4-TCNQ층을 삽입한 소자의 특성은 삽입하지 않은 소자에 비해 향상되었다.

  • PDF

(1-X) ${Na}_{1/2}{Sm}_{1/2}TiO_3-X\;{Li}_{1/2}{Nd}_{1/2}TiO_3$ 세라믹스의 고주파 유전특성 (Microwave Dielectric Properties of (1-X) ${Na}_{1/2}{Sm}_{1/2}TiO_3-X\;{Li}_{1/2}{Nd}_{1/2}TiO_3$ Ceramics)

  • 윤중락;홍석경;김경용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1103-1105
    • /
    • 1993
  • Microwave characteristics of the system (1-X) ${Na}_{1/2}{Sm}_{1/2}TiO_3$[NST]-X ${Li}_{1/2}{Nd}_{1/2}TiO_3$[LNT] were investigated. The dielectric constant and unloaded Q were 86,1950 respectively for NST at 3GHz and 80,500 for LNT. 0.4 NST - 0.6 LNT system has the dielectric constant ${\varepsilon}r$=86.2, Q=930(3GHz), temperature coefficient of the resonant frequency ${\tau}f$ = 8 ppm/$^{\circ}C$ when sintered at $1450^{\circ}C$ for 2h.

  • PDF

활성탄/리튬티탄산화물 커패시터의 전기화학적 특성에 미치는 비닐에틸렌카보네이트의 영향 (Effect of Vinyl Ethylene Carbonate on Electrochemical Characteristics for Activated Carbon/Li4Ti5O12 Capacitors)

  • 권용갑;최호석;이중기
    • 전기화학회지
    • /
    • 제15권3호
    • /
    • pp.190-197
    • /
    • 2012
  • 비닐에틸렌 카보네이트(VEC: vinyl ethylene carbonate)를 전해질 첨가제로 사용했을 때 하이브리드 커패시터(hybrid capacitors) 전극에서 나타나는 전기화학적 특성변화에 대해서 고찰하였다. 하이브리드 커패시터는 양극은 활성탄(AC : activated carbon) 음극은 리튬티타늄옥사이드(LTO: $Li_4Ti_5O_{12}$)를 사용하였고, 전해질로서는 에틸렌 카보네이트(EC: ethylene carbonate): 디메틸 카보네이트 (DMC: dimethyl carbonate) : 에틸메틸 카보네이트(EMC : ethyl methyl carbonate)를 사용하였고, 염으로 육불화인산리튬($LiPF_6$: lithium hexafluoro phosphate)을 사용하였다. 전극 표면의 산소관능기 그룹을 제거하고, 표면을 환원시킴으로써 전극에 안정성을 향상시킨다고 알려진 VEC의 첨가량에 따른 전기화학적 특성을 평가하였으며, 0.7%(부피비)의 VEC첨가시, 가장 우수한 전기화학적 특성을 얻을 수 있었다. 0.7% 이상 첨가하였을 경우, 오히려 부반응 증가로 전기화학적 성능이 감소하였다. X-ray photoelectron spectrocopy (XPS) 결과로부터 LTO 전극에서 VEC가 첨가되지 않은 전해질에 비해 LiF가 감소한 것을 확인 할 수 있었다. VEC가 첨가되지 않은 전해질은 2500 사이클 후, 43.2 %의 용량 유지를 나타냈지만, 최적화된 VEC 첨가를 통하여 82.7 %의 높은 용량을 유지하는 특성을 가진 하이브리드 커패시터를 얻을 수 있었다.

전구체 공정부산물 LNO(Li2NiO2)계 양극활물질로부터 탄산리튬 및 니켈 회수연구 (Recoverty of Lithium Carbonate and Nickel from Cathode Active Material LNO(Li2NiO2) of Precursor Process Byproducts)

  • 표재중;왕제필
    • 자원리싸이클링
    • /
    • 제28권4호
    • /
    • pp.30-36
    • /
    • 2019
  • 본 연구는 폐 리튬이온전지의 양극활물질인 LNO($Li_2NiO_2$) 공정부산물로부터 $CO_2$ 열반응 공정을 통하여 Li 분말을 회수하였다. Li 분말을 회수하는 공정은 $CO_2$ 주입량이 300 cc/min인 분위기에서 $600^{\circ}C$, 1 min 유지하여 $Li_2NiO_2$ 상을 $Li_2CO_3$상과 NiO상으로 상분리 시켰다. 이 후 회수한 시료:증류수 = 1:50 무게비로 수 침출 후 감압 여과를 통해 용액에서 $Li_2CO_3$, 여과지에서 NiO 분말을 회수하였다. Ni 순도를 높이기 위해 $H_2$ 분위기에서 3시간 유지하여 NiO에서 Ni로 환원하였다. 위와 같은 공정을 통해 회수한 탄산리튬 용액의 Li의 농도 2290 ppm, Li의 회수율은 92.74%를 달성하였고 Ni은 최종적으로 순도는 90.1%, 회수율 92.6%의 분말을 제조하였다.