• Title/Summary/Keyword: 60 Hz power line noise

Search Result 27, Processing Time 0.024 seconds

A Study on the Conducted Noise of the Intrabuilding Power Line (건물내 전력선에 존재하는 전도성 잡음에 관한 연구)

  • 정호영;강창언
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.1
    • /
    • pp.55-62
    • /
    • 1991
  • In this paper, the characteristics of the conducted noise on the intrabuilding power line are measured and analyzed with three steps. In the result, the conducted noise on the intrabuilding power line is mainly divided into three types: the random disturbance which is the background noise with full band spectrum, the harmonic noise correlated with the 60Hz power frequency, and the periodic impulse noise of 120 Hz synchronized with the 60Hz power frequency.

  • PDF

Power Line Noise Reductions in ABR by Properly Chosen Iteration Numbers (ABR에서 반복회수 설정에 의한 전력선 잡음의 제거)

  • 안주현;김수찬;남기창;심윤주;김희남;송철규;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.241-247
    • /
    • 2001
  • ABR(auditory brainstem response) is one of the audiometry which measures objective hearing threshold level by acquiring electric evoked potentials emanated from auditory nerve system responding to an auditory stimulation. However, the obtained potentials which are largely interfered by power line noise, have extremely low SNR, thus ensemble average algorithm is generally used. The purpose of this study was to investigate the effect of iteration number in ensemble average on the reduction of the power line noise. The power line noise was modeled to be a 60 Hz sinusoidal signal and the energy of the modeled signal was calculated when it was averaged. It was verified by simulation that the energy had the periodic zero points for each stimulation rate, and 60 Hz signal induced by the power line was applied to the developed ABR system to confirm that the period of zero energy point was the same with that of the simulation. By the properly selected iteration number, power line noise could be reduced and more reliable ABR could be acquired.

  • PDF

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.

The Simulation of Transmission Line Fault-Induced Noise Signals. (선로고장시 발생되는 잡음의 시뮬레이션)

  • Shin, Myung-Chul;Kim, Mu-Woong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

The Case Study of The Generator Noise generated by Stator Looseness (발전기 고정자 이완에 의한 소음발생 고찰)

  • Yoo, Mu-Sang;Han, Seung-Woo;Roh, Cheol-Woo;Ryu, Kil-Su;Oh, Seung-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.527-532
    • /
    • 2014
  • Generator is the main equipment of a power plant that generates electric power. The line frequency is 60Hz, since that is operated at 3600rpm in fossil power plant. Therefore, the specific frequency 120Hz by the electromagnetic excitation force is generated inherently. If the looseness of stator at generator happens, abnormal sound that has 120Hz and the harmonic frequency is emitted from generator frame. In that case, binding of end-winding or re-wedging is needed for the reduction of sound level. In case of severe level of sound, belly band can be additionally installed at core. In this paper, the characteristics of generator sound is described and modal data is analyzed after installation of belly band.

  • PDF

A Study on Performance of Indirect-contact Driven-right-leg Ground in Indirect-contact ECG Measurement (간접접촉 심전도 측정에서의 간접접촉 오른발 구동 접지 성능에 대한 연구)

  • Lim, Yong-Gyu;Kim, Ko-Keun;Park, Kwang-Suk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.280-287
    • /
    • 2008
  • For the reduction of common-mode noise level in Indirect-contact ECG (IDC-ECG) measurement a driven-right-leg grounding method was a lied to the IDC-ECG. Because the IDC-ECG does not require any direct contact between the electrodes and the human skin. it is adequate for un-constraining long-term ECG measurement at home and its various applications are now under development. However, larger 60 Hz noise induced by power line a ears in IDC-BCG than in conventional ECG, that is a restriction of IDC-ECG a application. In this study, the driven-right-leg ground which has been used in conventional direct-contact ECG, was adapted to the IDC-ECG measurement by feedback of the inversion of amplified common-mode noise to the body through the conductive fertile laid on the chair seat By this study, indirect-contact driven-right-leg ground was developed and it was shown to work stably. It was shown that the level of 60Hz power line noise was reduced to about -40 dB when the driven-right-leg gain was 1000. This study shows that we can extend the upper limit of the frequency band of IDC-ECG to 100Hz from 30Hz which is conventional upper limit in IDC-ECG, and we can raise the ground impedance between the body and conductive textile. So it is expected that the application area of the IDC-ECG will be extended by the results of this study.

  • PDF

Implementation of Power Line Modem Using a Direct Sequence Spread Spectrum Technique (직접대역확산 기법을 적용한 전력선 모뎀의 구현)

  • 송문규;김대우;사공석진;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.2
    • /
    • pp.218-230
    • /
    • 1993
  • A power line modem(PLM) which transfers data safely through power lines in houses or small offices is considered. When a power line is used for communications, transmitted signals could be affected by the channel characteristics such as frequency-selective fading, interference, and time-varying attenuation. In order to overcome these impairments, a direct sequence(DS) technique which is well known as an effective instrument against a variety of interferences and hostile channel properties is employed. Using a DS technique, however, requires more circuits such as PN code generator circuits, code modification circuits, and complicated synchronization circuits, and it also results in substantial acquisition delay. In this paper, some of these circuits are implemented via software programmed in the system controller, and the complicated synchronization circuits are replaced by simple circuits utilizing a 60 Hz power signal for synchronization. The synchronization ciruits used in this paper virtually eliminate the substantial acquisition delay, and is also designed to free influence of 60 Hz zero crossing jitters which reside in a power signal. As a result, a PLM using a DS technique is realized in the form of wall-socket plug, and the PLM hardware would be very much simplified.

  • PDF

Simulation for PLC using Matlab (Matlab을 이용한 전력선 통신 시뮬레이션)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1002-1003
    • /
    • 2006
  • Power line communication: PLC which easy to install at anywhere near outlet for electric machine. PLC uses transmission line for voltage of which is 60 Hz. One of the important thing is the processes of adding signal to power line and extracting the signal from power line, another is to choose the strong modulation method which sends signals to long distance without loosing in PLC channel. but PLC channel have very high and variable noise and attenuation and then it is very hard to transmit optimally between the transmitter and the receiver. AWGN, impulse noise and attenuation are created. To overcome the noise and attenuation. Multi-carrier Modulation methods like as OFDM and DMT which divide the channel into many sub-channel are powerful communication methods for PLC. In this paper, PLC channels are simulated for getting BER by Matlab simulink

  • PDF

Channel Analysis of inside PLC (옥내 전력선 채널 분석)

  • Hong Duc-Pyo;Lee Jin-Mok;Kim Soo-Cheol;Choi Jae-Ho;Hong Hyun-Mun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.456-458
    • /
    • 2006
  • Power line communication: PLC which easy to install at anywhere near outlet for electric machine. PLC uses transmission line for voltage of which is 60 Hz. Signals don't affect to electric machine in PLC because they are very small voltage. One of the important thing is the processes of adding signal to power line and extracting the signal from power line, the other is to choose the strong modulation method which sends signals long distance without loosing in PLC channel. but PLC channel have very high and variable noise and attenuation and then it is very hard to transmit optimally between the transmitter and the receiver. After all, impedance and noise problems of PLC channel must be overcame. Noises of 2 kinds which are AWGN abd impulse noise and attenuation are orated. To overcome the noise. Recently, Multi-carrier Modulation: MCM methods like as OFDM and DMT which are divide the channel into many sub-channel have been studied. those are powerful communication methods in PLC. In this paper, PLC channels made up of 3 numbers of noise and attenuation are simulated for getting BER by Matlab simulink.

  • PDF

잡음동기형 표본화 제어기에 의한 전력선 잡음의 적응제거

  • Ko, Han-Woo;Kim, Won-Ky;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.117-124
    • /
    • 1988
  • A new implementation of a noise tracking filter is prposed to eliminate time-varying 60 Hz noise and its harmonics and baselins wandering in biological signals. This technique was applied to ECG. Filter's notch frequency could track the power line frequency well and it showed much better characteristics than the conventional method.

  • PDF