• Title/Summary/Keyword: 6 MV X-ray

Search Result 209, Processing Time 0.026 seconds

Effects of Adjuvant Radiation Therapy and Chemotherapy Following Curative Surgery in Locally Advanced Rectal Cancer (국소 진행된 직장암에서 근치적 절제술 후 방사선치료와 항암화학요법과의 병용치료에 대한 효과)

  • Kang, Ki-Mun;Choi, Ihl-Bohng;Kim, In-Ah;Jang, Jee-Young;Shin, Kyung-Sub;Jang, Suck-Kyun;Lee, Jae-Hak;Kim, Young-Ha;Won, Chong-Man;Choi, Dong-Hwan;Kim, Jin-Seung;Park, Shinn-Hee
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.121-128
    • /
    • 1997
  • Purpose : To evaluate the effect of postoperative adjuvant radiation therapy and chemotherapy on the survival, pattern of failure and complication for locally advanced rectal carcinoma Materials and Methods : From October 1992 to September 1995, twenty eight patients with rectal carcinoma were treated by postoperative adjuvant radiation therapy and chemotherapy Radiation therapy was delivered with 6MV and 15MV linear accelerator, 180c0y fractions 5 day per week. Total radiation doses were 5040cGy in $B_{2+3}$ and 5580cGy in $C_{2+3}$. Within 4 weeks after radical surgery. 5-FU$(400mg/m^2/day)\;and\;Leucovorin(20mg/m^2/day)$ were administered by intravenous injection for 4 days during the first and fifth week of radiation therapy. The median follow up was 19 months with a range 2 to 47 months. Results : The 2 year overall survival and disease free survival rates were $78.6\%\;and\;70.8\%$, respectively. The 2 year overall survival was $93.0\%\;in\;B_{2+3}$ and $76.2\%\;in\;C_{2+3}$(p=0.11) The 2 year disease free survival was $79.4\%\;in\;B_{2+3}\;and\;69.2\%\;in\;C_{2+3}(p=0.13)$. The overall failure rate was $21.42\%$(6/28) including $10.72\%$(3/28) locoregional recurrence, $3.62\%$(1/28) distant metastasis and $7.12\%$(2/28) locoregional recurrence with distant metastasis. The overall locoregional recurrence rate was $17.92\%$(5/28). The 2 year locoregional recurrence rates were $13.32\%(2/15)\;and\;23.12\%$(3/13) for respectively for $B_{2+3}\;and\;C_{2+3}$ The difference between the locoregional recurrence of $B_{2+3}\;and\;C_{2+3}$ patients was not significant(p=0.07). Complications developed in 13 patients$(46.42\%)$, including 8 dermatitis, 7 loose stool, 6 leukopenia, 4 tenesmus, 2 diarrhea. In Univariate analysis, there was no statistically significant factor except for tumor grade in locoregional recurrence, disease free survival and overall survival rate(p=0.04, 0.05, 0.04). Conclusion : This study sugges1s that postoperative adjuvant radiation therapy and chemotherapy is effective in patients with locally advanced rectal cancer. Therefore these results need to be confirmed with a long term follow-up and larger number of patients with the further clinical trials including prospective controlled studies.

  • PDF

Results of Radiation Therapy for Carcinoma of the Uterine Cervix (자궁경부암의 방사선치료 성적)

  • Lee Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.359-368
    • /
    • 1995
  • Purpose : This is a retrospective analysis for pattern of failure, survival rate and prognostic factors of 114 patients with histologically proven invasive cancer of the uterine cervix treated with definitive irradiation. Materials and Methods : One hundred fourteen patients with invasive carcinoma of the cervix were treated with a combination of intracavitary irradiation using Fletcher-Suit applicator and external beam irradiation by 6MV X-ray at the Ewha Womans University Hospital between March 1982 and Mar 1990. The median age was 53 years(range:30-77 years). FIGO stage distribution was 19 for IB, 23 for IIA, 42 for IIB, 12 for IIIA and 18 for IIIB. Summation dose of external beam and intracavitary irradiation to point A was 80-90 Gy(median:8580 cGy) in early stage(IB-IIA) and 85-100 Gy(median:8850 cGy) in advanced stage(IIB-IIIB). Kaplan-Meier method was used to estimate the survival rate and multivariate analysis for progrostic factors was performed using the Log likelihood for Weibull Results : The pelvic failure rates by stage were $10.5{\%}$ for IB. $8.7{\%}$ for IIA, $23.8{\%}$ for IIB, $50.0{\%}$ for IIIA and $38.9{\%}$ for IIIB. The rate of distant metastasis by stage were $0{\%}$ for IB, $8.7{\%}$ for IIA, $4.8{\%}$ for IIB. $0{\%}$ for IIIA and $11.1{\%}$ for IIIB. The time of failure was from 3 to 50 months and with median of 15 months after completion of radiation therapy. There was no significant coorelation between dose to point A($\leq$90 Gy vs >90 Gy) and pelvic tumor control(P>0.05). Incidence rates of grade 2 rectal and bladder complications were $3.5{\%}$(4/114) and $7{\%}$(8/114), respectively and 1 patient had sigmoid colon obstruction and 1 patient had severe cystitis. Overall 5-year survival rate was $70.5{\%}$ and disease-free survival rate was $53.6{\%}$. Overall 5-year survival rate by stage was $100{\%}$ for IB, $76.9{\%}$ for IIA, $77.6{\%}$ for IIB $87.5{\%}$ for IIIA and $69.1{\%}$ for IIIB. Five-rear disease-free survival rate by stage was $81.3{\%}$ for IB, $67.9{\%}$ for IIA, $46.8{\%}$ for IIB, $45.4{\%}$ for IIIA and $34.4{\%}$ for IIIB. The prognostic factors for disease-free survival rate by multivariate analysis was performance status(p= 0.0063) and response rate after completion of radiation therapy(p= 0.0026) but stage, age and radiation dose to point A were not siginificant. Conclusion : The result of radiation therapy for early stage of the uterine cervix cancer was relatively good but local control rate and survival rate in advanced stage were poor inspite of high dose irradiation to point A above 90 Gy. Prospective randomized studies are recommended to establish optimal tumor doses for various stages and volume of carcinoma of uterine cervix, And ajuvant chemotherapy or radiation-sensitizing agents must be considered to increase the pelvic control and survival rate in advanced cancer of uterine cervix.

  • PDF

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

Smad6 Gene and Suppression of Radiation-Induced Apoptosis by Genistein in K562 Cells (K562 세포주에서 Genistein에 의해 억제되는 Radiation-induced Apoptosis의 조절 유전자)

  • Jeong, Soo-Jin;Jin, Young-Hee;Yoo, Yeo-Jin;Do, Chang-Ho;Jeong, Min-Ho;Huh, Gi-Yeong;Bae, Hye-Ran;Yang, Kwang-Mo;Moon, Chang-Woo;Oh, Sin-Geun;Hur, Won-Joo;Lee, Hyung-Sik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.245-251
    • /
    • 2001
  • Prupose : The genes involved on the suppression or radiation-induced apoptosis by genistein in K562 leukemia cell line was investigated. Materials and methods : K562 cells in exponential growth phase were irradiated with a linear accelerator at room temperature. For X-ray irradiation and drug treatment, cultures were prepared at $2\times10^5\;cells/mL$. The cells were irradiated with 10 Gy (Clinac 1800C, Varian, USA), Stock solutions of herbimycin A (HMA, Calbiochem, UK) and genistein (Calbiochem, UK) were prepared in dimethylsulfoxide (DMSO, Sigma, UK). After incubation at $37^{\circ}C$ for 24 h, PCR-select cDNA subtractive hybridization, dot hybridization, DNA sequencing and Northern hybridization were examined. Results : Smad6 gene was identified from the differentially expressed genes in K562 cells incubated with genistein which had been selected by PCR-select cDNA subtractive hybridization. The mRNA expression of Smad6 in K562 cells incubated with genistein was also higher than control group by Northern hybridization analysis. Conclusion : We have shown that Smad6 involved on the suppression of radiation-induced apoptosis by genistein in K562 leukemia cell line. It is plausible that the relationship between Smad6 and the suppression of radiation-induced apoptosis is essential for treatment development based on molecular targeting designed to modify radiation-induced apoptosis.

  • PDF

A Study on Apoptotic Signaling Pathway in HL-60 Cells Induced by Radiation (급성전골수성백혈병 HL-60 세포주에서 방사선조사에 의한 세포고사기전)

  • Kim Hye Jung;Moon Sung Keun;Lee Jae Moon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2001
  • Purpose : The mechanical insights of death of cancer cells by ionizing radiation are not of yet clearly defined. Recent evidences have demonstrated that radiation therapy may induce cell death via activation of signaling pathway for apoptosis in target cells. This study is designed whether ionizing radiation may activate the signaling cascades of apoptosis including caspase family cysteine pretenses, $Bcl_2/Bax$, cytochrome c and Fas/Fas-L in target cells. Materials and Methods : HL-60 cells were irradiated in vitro with 6 MV X-ray at dose ranges from 2 Gy to 32 Gy. The cell viability was tested by M assay and the extent of apoptosis was determined using agarose gel electrophoresis. The activities of caspase proteases were measured by proteolytic cleavages of substrates. Western blot analysis was used to monitor PARP, Caspase-3, Cytochrome-c, Bcl-2, Bax, Fas and Fas-L. Results : Ionizing radiation decreases the viability of HL-60 cells in a time and dose dependent manner. Ionizing radiation-induced death in HL-60 cells is an apoptotic death which is revealed as characteristic ladder-pattern fragmentation of genomic DNA over 16 Gy at 4 hours. ionizing radiation induces the activation of caspase-2, 3, 6, 8 and 9 of HL-60 cells in a time-dependent manner. The activation of caspase-3 pretense is also evidenced by the digestion of poly (ADP-ribose) polymerase and procaspase 3 with 16Gy ionizing irradiation. Anti-apoptotic Bcl2 expression is decreased but apoptotic Bax expression is increased with mitochondrial cytochrome c release in a time- dependent manner. In addiiton, expression of Fas and Fas-L is also increased in a time dependent manner. Conclusion : These data suggest that ionizing radiation-induced apoptosis is mediated by the activation of various signaling pathways including caspase family cysteine proteases, $Bcl_2/Bax$, Fas and Fas-L in a time and dose dependent manner.

  • PDF

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer (원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과)

  • Kim, Woo-Chul;Kim, Hun-Jung;Park, Jeong-Hoon;Huh, Hyun-Do;Choi, Sang-Huoun
    • Radiation Oncology Journal
    • /
    • v.29 no.1
    • /
    • pp.28-35
    • /
    • 2011
  • Purpose: Recently, the use of radiosurgery as a local therapy in patients with early stage non-small cell lung cancer has become favored over surgical resection. To evaluate the efficacy of radiosurgery, we analyzed the results of stereotactic body radiosurgery in patients with primary or recurrent non-small cell lung cancer. Materials and Methods: We reviewed medical records retrospectively of total 24 patients (28 lesions) with non-small cell lung cancer (NSCLC) who received stereotactic body radiosurgery (SBRT) at Inha University Hospital. Among the 24 patients, 19 had primary NSCLC and five exhibited recurrent disease, with three at previously treated areas. Four patients with primary NSCLC received SBRT after conventional radiation therapy as a boost treatment. The initial stages were IA in 7, IB in 3, IIA in 2, IIB in 2, IIIA in 3, IIIB in 1, and IV in 6. The T stages at SBRT were T1 lesion in 13, T2 lesion in 12, and T3 lesion in 3. 6MV X-ray treatment was used for SBRT, and the prescribed dose was 15~60 Gy (median: 50 Gy) for PTV1 in 3~5 fractions. Median follow up time was 469 days. Results: The median GTV was 22.9 mL (range, 0.7 to 108.7 mL) and median PTV1 was 65.4 mL (range, 5.3 to 184.8 mL). The response rate at 3 months was complete response (CR) in 14 lesions, partial response (PR) in 11 lesions, and stable disease (SD) in 3 lesions, whereas the response rate at the time of the last follow up was CR in 13 lesions, PR in 9 lesions, SD in 2 lesions, and progressive disease (PD) in 4 lesions. Of the 10 patients in stage 1, one patient died due to pneumonia, and local failure was identified in one patient. Of the 10 patients in stages III-IV, three patients died, local and loco-regional failure was identified in one patient, and regional failure in 2 patients. Total local control rate was 85.8% (4/28). Local recurrence was recorded in three out of the eight lesions that received below biologically equivalent dose 100 $Gy_{10}$. Among 20 lesions that received above 100 $Gy_{10}$, only one lesion failed locally. There was a higher recurrence rate in patients with centrally located tumors and T2 or above staged tumors. Conclusion: SBRT using a CyberKnife was proven to be an effective treatment modality for early stage patients with NSCLC based on high local control rate without severe complications. SBRT above total 100 $Gy_{10}$ for peripheral T1 stage patients with NSCLC is recommended.

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF