• Title/Summary/Keyword: 6/8 structure

Search Result 3,797, Processing Time 0.035 seconds

Study on the Utilization of Sawdust Bedding Barn for Dairy Cows (착유우의 톱밥발효우사 이용연구 제 1 보 : 낙농가의 톱밥발효우사 형태별 이용효과 비교)

  • Kweon, Du-Jung;Kweon, Ung-Gi;Ki, Wang-Seok;Lee, Kee-Jong;Han, Jeong-Dae;Jung, Suk-Chan;Kang, Seung-Won;Kang, Sang-Lyol;Jung, Hyoung-Sup;Chang, Hak-Joo
    • Journal of Animal Environmental Science
    • /
    • v.1 no.1
    • /
    • pp.9-19
    • /
    • 1995
  • This study was carried out to investigate the effect of sawdust bedding barn on manure handing, management labour and physiological aspect of dairy cows, and then to establish the criteria on the optimum utilization method of sawdust bedding barn. 46 tie stall barns and 49 sawdust bedding barns were surveyed to cmopare the milk productivity between two different barns, and also 5 tie stall barns, 15 sawdust bedding barns and 1 rice hull bedding barn were selected to study the utilization situation of sawdust barn in Kyung-Ki province area. The major results obtained were as follows; 1. The roof material of sawdust barn were consisted of 66% vinyl house, 23% PVC light and 11% slate and galvanum coated tin. Most of the floor structure was earth ground with the rate of the approximately 82%. 2. The average occupied area of sawdust bed per cow was 15.2 $m^2$, depth that 30 cm and the utilization period was 12 months. 3. Milk Yield was significantly higher at sawdust barn than at tie stall barn(P<0.01). Bacterial and somatic cell count in raw milk were less at the sawdust barn than in tie stall barn. However, there was not significance difference between two barns. 4. The labour hour needed to cow management in the sawdust barn was approximately 48% of that of tie stall barn. 5. The temperature and moisture content measured in sawdust bed were closely affected by seasonal ambient temperature. The skin and hair of cow were much cleaner at the PVC light roofed sawdust barn than any other roof materials. 6. The additives used for improving of fermentation did not show any effect on temperature and moisture content in sawdust bed. When the ambient temperature was $30.4^{\circ}C$, the surface temperature of measured 1 cm above the sawdust bed was $12.2^{\circ}C$ lower and the temperature of 100 cm above the sawdust bed was $2.4^{\circ}C lower under shading net facility than that of vinyl roofed one.7. The hoof length of miking cow was 7.95 cm in tie stall and 9.19 cm in sawdust barn with high significance (P<0.01). And disease occurence such as mastitis and foot-rot tended to decrease in the sawdust barn. 8. The number of total bacteria and coliform bacteria were less in the sawdust bed compared with earth ground resting area. And a parasite strongyloides papillosus was detected but without any infected cow. 9. The nitrate($NO_3N$) content in non-roofed earth ground resting area and earth ground under the sawdust bed was likely to pollute the ground water. 10. In economic point of view, rice hull bedding barn was the cheapest among different systems. And in the sawdust bedding barn PVC light + slate roofed barn was most desirable, and vinyl roofed one the least.

  • PDF

Effect of Long-Term Steeping and Enzyme Treatment of Glutinous Rice on Yukwa Characteristics - II. Physicochemical Characteristics of Enzyme-treated Glutinous Rice Flour - (찹쌀의 장기 수침 및 효소처리가 유과의 특성에 미치는 영향 -제 2 보: 효소처리시킨 찹쌀가루의 이화학적 특성 연구-)

  • Sohn, Kyung-Hee;Park, Jun
    • Korean journal of food and cookery science
    • /
    • v.14 no.3
    • /
    • pp.225-231
    • /
    • 1998
  • Enzyme-treated glutinous rice flour, which was developed to shorten or skip a steeping process during the preparation of Yukwa, was analyzed for its physicochemical characteristics and compared with glutinous rice flour made by 28-day-steeping method. Total sugar content of the 28-day-steeped flour was the highest among all groups, on the other hand, the reducing sugar content was higher in enzyme-treated glutinous rice flour. The viscosity of enzyme-treated flours was significantly lower than that of the 28-day-steeped and particularly showed the lowest value at 65$^{\circ}C$. The contents of Ca$\^$2+/ and Mg$\^$2+/ in enzyme-treated glutinous rice flours were higher than those of the 28-day-steeped group, however, the content of P$\^$+/ was lower. Free sugar detected in glutinous rice flour prepared from 28-day-steeping method was glucose only, but enzyme-treated flours contained maltose and glucose, and the content of total free sugar was much higher than that of the 28-day-steeped group. In microscopic structure, both 28-day-steeped and enzyme-treated flours showed the particle size decreased and porous surface on some part of the flour granule.

  • PDF

Early Proterozoic Moyitic Series in Daqingshan, Inner Mongolia : Their Characteristics and Tectonis, Magmatic and Thermodynamic Model (내몽고 다큉샨내의 초기원생대 모이아이트계열 : 특성과 지구조, 마그마 그리고 열역학적 모델)

  • Lin CAO;Wei JIN
    • The Journal of the Petrological Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.77-85
    • /
    • 1997
  • The Early Proterozoic reworked rock association occurs within the Preacmbrian high grade metamorphic rocks in the area of Daqingshan, Inner Molgolia. In this association, the various large scale ductile deformation belts, form a nappe structure where the foliation steeply dips to north and the lineation ($340^{circ}-30^{\circ}$) plunges at $45^{\circ}55^{\circ}$. This result indicates the subduction/extension with northern part thrusting over the southern part at high angle. The southern subducted microlithon has the characteristics of prograde metamorphism. The northern thrusted microlithon shows the evidence of retrograde metamorphism with decreasing pressure and increasing temperature. The main rock types of Early Proterozoic Moyites are biotite adamellite and syenogranites occurring in the form of small batholiths or stocks and alkali-feldspar granites in veins. The biotite adamellites are progressively contacted with the Archean and Early Proterozoic rocks and contain a great deal of enclaves of metamorphosed rocks, suggesting an anatexis origin. The geochemical characteristics of moyites show the typical features of anatexis granite. At middle to late Early Proterozoic time, the continent-continent collision formed the large scale thrusting and imbrication of Archean basement rocks. According to the mineral assemblage and thermobarometer of Paria et al. (1988) give the following P-T condition : up-faulted block; $700-710^{\circ}C$, 0.72-0.78 Gpa (early stage) and $600^{\circ}C$, 0.44 Gpa (late stage), footwall block; $620^{\circ}C$, 0.8 Gpa (early stage), $620-840^{\circ}C$, 0.64-0.45 Gpa (peak) and $620-630^{\circ}C$, 0.35Gpa (late stage). These results suggest a clockwise P-T-t path (jin et al., 1991, 1994). According to the depth-temperature model in the comperature subduction zone and the experimental data of Wyllie et al. (1983), we propose a tectonic-magmatic-thermal model to account for metamorphism-anatexis of moyite occurring in subduction-shear zone.

  • PDF

Morphological, Physiological andd Biochemical Characteristics of Early Senescence Mutant in Rice (Oryza sativa L) (벼의 조기노화 변이체의 형태, 생리 및 생화학적 특성)

  • 이숙영
    • Korean Journal of Plant Resources
    • /
    • v.8 no.3
    • /
    • pp.325-334
    • /
    • 1995
  • The early senescence mutant induced from Gihobyeo by $\gamma-ray$ irradiation was determined. The mutated gene expression was identified with comparing the characteristic of original cultivar. The mutant had so similar the morphological characteristics to original cultivar that it couldn't be distinguished until senescence occurred at about 20 days after heading. Suddenly yellow leaves were observed within a few days due to great decreases in total chlorophyll and various carotenoid contents. Transmission electron microscopy showed the formation of starch granules, distortion of fine structure of leaf cell organelles, especially grana structures, and the decrease in grain filled after senescence occurred. But banding patterns of total proteins and isozymes have not show any differences, The early senescence mutant will be very useful for study material not only on physiological and biochemical properties of plant senescence but also on gene expression regulating senescence which gives great influence on yield potential and its stability.

  • PDF

Pattern of Pusan Station Shopping District(II) (부산역(釜山驛) 상점가(商店街)의 패턴(II))

  • Kim, Won-Kyung
    • Journal of the Korean association of regional geographers
    • /
    • v.5 no.2
    • /
    • pp.47-117
    • /
    • 1999
  • This study concern with the pattern of Pusan Station shopping district within Pusan City, Korea, one of the special functioned shopping district within Pusan City. This paper will serve as a part of series studies which attempt to clarify the internal structure of Pusan as a whole. Part(II) of this study deals with the functions including living related, restaurants and others. The pattern of floors, size of shops, street corners and widths of streets were also analysed. The results are as follows: 1. In terms of numbers of firms in living related function, Pusan Station shopping district is the $7{\sim}8th$ ranked central place among nine the highest centers within Pusan City. Pusan Station shopping district has not much promoted vertical spatial differentiation comparatively, and also it's intensity of land use is the lower among nine the highest centers. It is presented that intimate relationship between intensity of vertical land use and classes of central places within the city. The ratio of inns and hotels in Pusan Station shopping district is third ranked in Pusan City. And the size of inns and hotels in this area is the most largest among the nine highest ranked central places within Pusan City. These presented that the traditional characteristics of station area as a special functioned shopping district. Inns and hotels mainly located along the narrower and back street. And it forms agglomerated areas or 'an alley of inns' at the inner parts of blocks, some like a 'hidden flower'. In Korea, 'alley' means that an area of specialization gains the prestige, traditionally. 2. Restaurants mainly locate along the narrower and back streets. And agglomerated areas of restaurants coincide with the agglomerated area of drinking places. It shows that these two kinds of functions need the same locational conditions. The ratio of Chinese restaurants is the highest in the Pusan Station shopping district. It's due to the agglomerated area these kinds of restaurants at the 'China town'. 3. Pusan Station shopping district has been formed along the streets within the residential areas. It's means that this shopping district now at the initial or middle growth era in development stage of shopping areas. 4. In general, wholesales and light manufacturing are located at peripheries within shopping district. But in Pusan Station shopping district, it dose not appear these spatial pattern. It shows that this area is lower ranked central place and not much progressed in spatial differentiation. 5. Particular firms which customers and workers have stayed more longer period of time are located at the far from the first floor. This vertical spatial differentiation is similar to the horizontal sequences. 6. Firms which have more ability of rental payment are located at street comers such as banks and pharmacies. In Pusan Station shopping district commercial facilities could not invade into the second third floors at narrower streets and first floor of back streets, still now.

  • PDF

MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN (Flowable Composite Resin의 미세변연누출 및 전단결합강도)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

A Structural Model for Quality of Life in Women Having Hysterectomies (여성의 자궁절제술후 삶의 질 구조모형)

  • 김숙남
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.1
    • /
    • pp.161-173
    • /
    • 1999
  • The purpose of this study was to develope and test the structural model for quality of life in women having hysterectomies. A hypothetical model was constructed on the basis of previous studies and a review of literature. The conceptual framework was built around eight constructs. Exogenous variables included in this model were marital intimacy, importance of uterus, professional support, positive coping behavior and pre-operative symptoms. Endogenous variables were spouse's support, sense of loss and quality of life. Empirical data for testing the hypothetical model was collected using a self-report questionnare from 203 women having hysterectomies at the outpatient clinics of four general hospitals and a mail survey in Pusan City. The Data was collected from December, 1997 to January, 1998. Reliability of the eight instruments was tested with Cronbach's alpha which ranged from 0.639-0.915. For the data analysis, SPSS 7.5 WIN Program and LISREL 8.12 WIN Program were used for descriptive statistics and covariance structural analysis. The results of covariance structure analysis were as follows : 1. Hypothetical model showed a good fit with the empirical data. [$\chi$$^2$=6.93(df=5, P=.23), GFI=.99, AGFI=.94, RMSR=.019, NNFI=.97, NFI=.98, CN=440, standardized residuals(-2.14-2.10)] 2. For the parsimony of model, a modified model was constructed by deleting 3 paths and adding 1 path according to the criteria of statistical significance and meaning. 3. The modified model also showed a good fit with the data. [$\chi$$^2$=5.26(df=7, P=.63), GFI=.99, AGFI=.97, RMSR=.014, NNFI=1.02, NFI=.99, CN=710, standardized residuals(-1.46-1.70)] Results of the testing of the hypothesis were as follows : 1. Marital intimacy(${\gamma}$11=.78, t=14.37) and professional support(${\gamma}$13=.12, t=2.12) had a significant direct effect on the spouse's support. 2. Pre-operative symptoms(${\gamma}$25=.32, t=3.12), importance of uterus(${\gamma}$22=.20, t=2.61) and spouse's support($\beta$2l=-.19, t=-2.43) had a significant direct effect on the sense of loss. 3. Sense of loss($\beta$32=-.66, t=-9.83) had a direct effect on the quality of life. Marital intimacy had a direct(${\gamma}$31=.19, t=3.33), indirect(${\gamma}$31=.14, t=2.52) and total effect(${\gamma}$31=.25, t=4.41) on the quality of life. Professional support had a direct effect(${\gamma}$33=.11, t=2.07) and total effect(${\gamma}$33=.13, t=2.31) on the quality of life. The direct effect of pre-operative symptoms(${\gamma}$35=-.36, t=4.02) and positive coping behavior(${\gamma}$34=.15, t=2.06) had the insignificant effect on the quality of life while, due to the idirect effect these variables had overall significant effect on the quality of life. The results of this study showed that the sense of loss had the most significant direct effect on the quality of life. Marital intimacy, pre -operative symptoms and spouse's support had a significant direct effect on this sense of loss. These four variables, the sense of loss, marital intimacy, pre-operative symptoms and spouse's support, were identified as relatively important variables. The results of this study suggested that there is needed to determine if nursing intervention would alleviate this sense of loss and promote a greater quality of life in women who have had hysterectomies.

  • PDF

A bilayer diffusion barrier of atomic layer deposited (ALD)-Ru/ALD-TaCN for direct plating of Cu

  • Kim, Soo-Hyun;Yim, Sung-Soo;Lee, Do-Joong;Kim, Ki-Su;Kim, Hyun-Mi;Kim, Ki-Bum;Sohn, Hyun-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.239-240
    • /
    • 2008
  • As semiconductor devices are scaled down for better performance and more functionality, the Cu-based interconnects suffer from the increase of the resistivity of the Cu wires. The resistivity increase, which is attributed to the electron scattering from grain boundaries and interfaces, needs to be addressed in order to further scale down semiconductor devices [1]. The increase in the resistivity of the interconnect can be alleviated by increasing the grain size of electroplating (EP)-Cu or by modifying the Cu surface [1]. Another possible solution is to maximize the portion of the EP-Cu volume in the vias or damascene structures with the conformal diffusion barrier and seed layer by optimizing their deposition processes during Cu interconnect fabrication, which are currently ionized physical vapor deposition (IPVD)-based Ta/TaN bilayer and IPVD-Cu, respectively. The use of in-situ etching, during IPVD of the barrier or the seed layer, has been effective in enlarging the trench volume where the Cu is filled, resulting in improved reliability and performance of the Cu-based interconnect. However, the application of IPVD technology is expected to be limited eventually because of poor sidewall step coverage and the narrow top part of the damascene structures. Recently, Ru has been suggested as a diffusion barrier that is compatible with the direct plating of Cu [2-3]. A single-layer diffusion barrier for the direct plating of Cu is desirable to optimize the resistance of the Cu interconnects because it eliminates the Cu-seed layer. However, previous studies have shown that the Ru by itself is not a suitable diffusion barrier for Cu metallization [4-6]. Thus, the diffusion barrier performance of the Ru film should be improved in order for it to be successfully incorporated as a seed layer/barrier layer for the direct plating of Cu. The improvement of its barrier performance, by modifying the Ru microstructure from columnar to amorphous (by incorporating the N into Ru during PVD), has been previously reported [7]. Another approach for improving the barrier performance of the Ru film is to use Ru as a just seed layer and combine it with superior materials to function as a diffusion barrier against the Cu. A RulTaN bilayer prepared by PVD has recently been suggested as a seed layer/diffusion barrier for Cu. This bilayer was stable between the Cu and Si after annealing at $700^{\circ}C$ for I min [8]. Although these reports dealt with the possible applications of Ru for Cu metallization, cases where the Ru film was prepared by atomic layer deposition (ALD) have not been identified. These are important because of ALD's excellent conformality. In this study, a bilayer diffusion barrier of Ru/TaCN prepared by ALD was investigated. As the addition of the third element into the transition metal nitride disrupts the crystal lattice and leads to the formation of a stable ternary amorphous material, as indicated by Nicolet [9], ALD-TaCN is expected to improve the diffusion barrier performance of the ALD-Ru against Cu. Ru was deposited by a sequential supply of bis(ethylcyclopentadienyl)ruthenium [Ru$(EtCp)_2$] and $NH_3$plasma and TaCN by a sequential supply of $(NEt_2)_3Ta=Nbu^t$ (tert-butylimido-trisdiethylamido-tantalum, TBTDET) and $H_2$ plasma. Sheet resistance measurements, X-ray diffractometry (XRD), and Auger electron spectroscopy (AES) analysis showed that the bilayer diffusion barriers of ALD-Ru (12 nm)/ALD-TaCN (2 nm) and ALD-Ru (4nm)/ALD-TaCN (2 nm) prevented the Cu diffusion up to annealing temperatures of 600 and $550^{\circ}C$ for 30 min, respectively. This is found to be due to the excellent diffusion barrier performance of the ALD-TaCN film against the Cu, due to it having an amorphous structure. A 5-nm-thick ALD-TaCN film was even stable up to annealing at $650^{\circ}C$ between Cu and Si. Transmission electron microscopy (TEM) investigation combined with energy dispersive spectroscopy (EDS) analysis revealed that the ALD-Ru/ALD-TaCN diffusion barrier failed by the Cu diffusion through the bilayer into the Si substrate. This is due to the ALD-TaCN interlayer preventing the interfacial reaction between the Ru and Si.

  • PDF

A Strategic Approach to Competitiveness of ASEAN's Container Ports in International Logistics (국제물류전략에 있어서 ASEAN의 컨데이너항만 경쟁력에 관한 연구)

  • 김진구;이종인
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.273-280
    • /
    • 2003
  • The purpose of this study is to identify and evaluate the competitiveness of ports in ASEAN(Association of Southeast Asian Nations), which plays a leading role in basing the hub of international logistics strategies as a countermeasure in changes of international logistics environments. This region represents most severe competition among Mega hub ports in the world in terms of container cargo throughput at the onset of the 21 st century. The research method in this study accounted for overlapping between attributes, and introduced the HFP method that can perform mathematical operations. The scope of this study was strictly confined to the ports of ASEAN. which cover the top 100 of 350 container ports that were presented in Containerization International Yearbook 2002 with reference to container throughput. The results of this study show Singapore in the number one position. Even compared with major ports in Korea (after getting comparative ratings and applying the same data and evaluation structure), the number one position still goes to Singapore and then Busan(2) and Manila(2), followed by Port Klang(4), Tanjugn Priok(5), Tanjung Perak(6), Bangkok(7), Inchon(8), Laem Chabang(9) and Penang(9). In terms of the main contributions of this study, it is the first empirical study to apply the combined attributes of detailed and representative attributes into the advanced HFP model which was enhanced by the KJ method to evaluate the port competitiveness in ASEAN. Up-to-now, none have comprehensively conducted researches with sophisticated port methodology that has discussed a variety of changes in port development and terminal transfers of major shipping lines. Moreover, through the comparative evaluation between major ports in Korea and ASEAN, the presentation of comparative competitiveness for Korea ports is a great achievement in this study. In order to reinforce this study, it needs further compensative research, including cost factors which could not be applied to modeling the subject ports by lack of consistently qualified in ASEAN.

  • PDF

Earthquake impacts on hydrology: a case study from the Canterbury, New Zealand earthquakes of 2010 and 2011

  • Davie, Tim;Smith, Jeff;Scott, David;Ezzy, Tim;Cox, Simon;Rutter, Helen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.8-9
    • /
    • 2011
  • On 4 September 2010 an earthquake of magnitude 7.1 on the Richter scale occurred on the Canterbury Plains in the South Island of New Zealand. The Canterbury Plains are an area of extensive groundwater and spring fed surface water systems. Since the September earthquake there have been several thousand aftershocks (Fig. 1), the largest being a 6.3 magnitude quake which occurred close to the centre of Christchurch on 22February 2011. This second quake caused extensive damage to the city of Christchurch including the deaths of 189 people. Both of these quakes had marked hydrological impacts. Water is a vital natural resource for Canterburywith groundwater being extracted for potable supply and both ground and surface water being used extensively for agricultural and horticultural irrigation.The groundwater is of very high quality so that the city of Christchurch (population approx. 400,000) supplies untreated artesian water to the majority of households and businesses. Both earthquakes caused immediate hydrological effects, the most dramatic of which was the liquefaction of sediments and the release of shallow groundwater containing a fine grey silt-sand material. The liquefaction that occurred fitted within the empirical relationship between distance from epicentre and magnitude of quake described by Montgomery et al. (2003). . It appears that liquefaction resulted in development of discontinuities in confining layers. In some cases these appear to have been maintained by artesian pressure and continuing flow, and the springs are continuing to flow even now. In spring-fed streams there was an increase in flow that lasted for several days and in some cases flows remained high for several months afterwards although this could be linked to a very wet winter prior to the September earthquake. Analysis of the slope of baseflow recession for a spring-fed stream before and after the September earthquake shows no change, indicating no substantial change in the aquifer structure that feeds this stream.A complicating factor for consideration of river flows was that in some places the liquefaction of shallow sediments led to lateral spreading of river banks. The lateral spread lessened the channel cross section so water levels rose although the flow might not have risen accordingly. Groundwater level peaks moved both up and down, depending on the location of wells. Groundwater level changes for the two earthquakes were strongly related to the proximity to the epicentre. The February 2011 earthquake resulted in significantly larger groundwater level changes in eastern Christchurch than occurred in September 2010. In a well of similar distance from both epicentres the two events resulted in a similar sized increase in water level but the slightly slower rate of increase and the markedly slower recession recorded in the February event suggests that the well may have been partially blocked by sediment flowing into the well at depth. The effects of the February earthquake were more localised and in the area to the west of Christchurch it was the earlier earthquake that had greater impact. Many of the recorded responses have been compromised, or complicated, by damage or clogging and further inspections will need to be carried out to allow a more definitive interpretation. Nevertheless, it is reasonable to provisionally conclude that there is no clear evidence of significant change in aquifer pressures or properties. The different response of groundwater to earthquakes across the Canterbury Plains is the subject of a new research project about to start that uses the information to improve groundwater characterisation for the region. Montgomery D.R., Greenberg H.M., Smith D.T. (2003) Stream flow response to the Nisqually earthquake. Earth & Planetary Science Letters 209 19-28.

  • PDF