• Title/Summary/Keyword: 5S Method

Search Result 18,182, Processing Time 0.049 seconds

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Equivalent stiffness method for nonlinear analysis of stay cables

  • Xia, G.Y.;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.5
    • /
    • pp.661-667
    • /
    • 2011
  • In the famous equivalent elasticity modulus method proposed by Ernst for the geometrical nonlinear analysis of stay cables, the cable shape was assumed as a parabolic curve, and only a part of the gravity load normal to the chord was taken into account with the other part of gravity load parallel to the chord being ignored. Using the actual catenary curve and considering the entire gravity load of stay cables, the present study has derived the equivalent stiffness method to analyze the sag effect of stay cables in cable-stayed bridges. The derived equivalent stiffness can be degenerated into Ernst's equivalent elasticity modulus method with some approximations. Therefore, the Ernst's method is a special and approximate formulation of the present method. The derived equivalent stiffness provides a theoretical explanation for the famous Ernst's formula.

Nonlocal buckling characteristics of heterogeneous plates subjected to various loadings

  • Ebrahimi, Farzad;Babaei, Ramin;Shaghaghi, Gholam Reza
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.5
    • /
    • pp.515-531
    • /
    • 2018
  • In this manuscript, buckling response of the functionally graded material (FGM) nanoplate is investigated. Two opposite edges of nanoplate is under linear and nonlinear varying normal stresses. The small-scale effect is considered by Eringen's nonlocal theory. Governing equation are derived by nonlocal theory and Hamilton's principle. Navier's method is used to solve governing equation in simply boundary conditions. The obtained results exactly match the available results in the literature. The results of this research show the important role of nonlocal effect in buckling and stability behavior of nanoplates. In order to study the FG-index effect and different loading condition effects on buckling of rectangular nanoplate, Navier's method is applied and results are presented in various figures and tables.

Effect of Particle Size on Thermal Property of RDX and HMX (HMX와 RDX의 열적 특성에 미치는 입자 크기의 영향)

  • Kim, Seung Hee
    • Applied Chemistry for Engineering
    • /
    • v.23 no.3
    • /
    • pp.352-357
    • /
    • 2012
  • Techniques of thermal analyses such as DSC and TGA have been used in the study of activation energy (Ea) and frequency factor (A) depending on the particle size of RDX and HMX. Activation energy and frequency factor were calculated by Kissinger's method and Vyazovkin's method. As the particle size of RDX increased, TGA showed activation energy increased, but DSC didn't show. However, In case of HMX, as the particle size increased, both of DSC and TGA showed increase in activation energy. Moreover, Vyazovkin's method can obtain activation energy and mechanism according to decomposition of RDX and HMX.

High Accuracy Classification Methods for Multi-Temporal Images

  • Hong, Sun Pyo;Jeon, Dong Keun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1E
    • /
    • pp.3-8
    • /
    • 1997
  • Three new classification methods for multi temporal images are proposed. They are named as a likelihood addition method, a likelihood majority method and a Dempster-Shafer's rule method. Basic strategies using these methods are to calculate likelihoods for each temporal data and to combine obtained likelihoods for final classification. These three methods use different combining algorithms. From classification experiments, following results were obtained. The method based on Dempster-Shafer's rule of combination showed about 12% improvement of classification accuracies compared to a conventional method. This method needed about 16% more processing times than that of a conventional method. The other two proposed method showed 1% to 5% increase of classification accuracies. However processing times of these two proposed method showed 1% to 5% increase of classification accuracies. However processing times of these two methods are almost the same with that of a conventional method. Among the newly proposed three methods, the Dempster-Shafer's rule method showed the highest classification accuracies with more processing time than those of other methods.

  • PDF

A Study of Estimation of Lumbar Intervertebral Disc Size by Colombini's Method (Colombini 방법에 의한 요추부 추간판 크기 추정에 관한 연구)

  • Kim, Jong-Soon
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.1
    • /
    • pp.23-31
    • /
    • 2007
  • Purpose: As a preliminary study, the purpose of this study was to examine the indirect estimation of the lumbar intervertebral disc size by two anthropometric methods, in order to compare these indirect methods with the direct analysis by radiological imaging. Methods: The wrist, elbow, knee, and ankle joint (both right and left) diameters were measured in 52 volunteers, and then intervertebral disc size was calculated using two anthropometric methods (Colombini and modified Colombini). The data were analysed with independent t-test to assess clinical usefulness. Results: When using right and left joint diameter, there was no significant difference in the estimation value of the L4-5 and L5-S1 intervetebral disc sizes. However, the study has shown that male subjects have significantly larger L4-5 and L5-S1 intervertebral disc sizes, compared with those of female subjects. In addition, disc sizes calculated by Colombini's formula were significantly larger than modified Colombini's formula. Conclusion: The indirect estimation of the intervertebral disc size by anthropometric method can be considered as a clinically useful method. However, further study should be conducted to compare anthropometric values with other radiological imaging.

  • PDF

Comparison of Vitrification and Slow Freezing for the Cryopreservation of Chicken Primordial Germ Cell (Ogye) (한국재래닭 (오계) 원시생식세포의 완만동결과 급속동결의 비교)

  • Kim, Sung Woo;Ko, Yeoung-Gyu;Byun, Mijeong;Do, Yoon Jung;Han, Jae Yong;Kim, Dong Hun;Seong, Hwan-Hoo;Kim, Hyun
    • Journal of Animal Science and Technology
    • /
    • v.55 no.5
    • /
    • pp.417-425
    • /
    • 2013
  • We sought to provide a method for freezing and preserving primordial germ cells, or an avian germ cell of a bird, as a material for developmental engineering or species preservation. The aim of this study was to compare the efficacy of slow freezing with a vitrification method for the cryopreservation of chicken primordial germ cells (PGCs). PGCs obtained from the germinal gonad of day 5.5-6 day (stage 28) cultured chick embryos, using the MACS method, were classified into two groups: slow freezing and vitrification. We examined the viability of PGCs after Cryopreservation. Four freezing methods were compared with each other, including the following: Method 1: The PGCs were frozen by a programmed freezer in a plastic straw, including 2.0 M ethylene glycol (EG) as cryoprotective additive (slow freezing) Method 2: The PGCs were vitrified in a plastic straw, including 8.0 M EG, plus 7% polyvinylpyrrolidone (PVP) (rapid freezing). Method 3: The slow freezing was induced with a cryotube including 2.0 M EG Method 4: The PGCs were frozen in a cryotube including 10% dimethyl suloxide (DMSO) (rapid freezing). After freezing and thawing, survival rates of the frozen-thawed PGCs from Method 1 to 4were 76.4%, 70.6%, 80.5% and 78.1% (p<0.05), respectively. The slow freezing ($-80^{\circ}C$ programmed freezer) method may provide better survival rates of frozen-thawed PGCs than the vitrification method for the cryopreservation of PGCs. Therefore, these systems may contribute to the cryopreservation of a rare avian species.

Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography (유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가)

  • Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

Determination of Loxoprofen Adsorption Isotherms by Frontal Analysis and Pulse Input Method (Frontal Analysis와 Pulse Input Method를 이용한 Loxoprofen의 등온흡착식 결정)

  • Lee, Eun;Park, Joon-Sub;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.371-375
    • /
    • 2006
  • Frontal analysis(FA) and Pulsed input method(PIM) have been frequently utilized to measure isotherm of single solute, as well as non-competitive isotherms of two solutes in chromatography(1). FA and PIM were used in this study as complementary methods to measure adsorption isotherms of loxoprofen racemate in HPLC. Prior to FA and PIM experiments, measurements of loxoprofen solubility were made at hexane/ethanol=50/50, 80/20, 95/5(v/v) with acetic acid(0.5%) for adjusting pH. The last composition(95/5) of hexane/ethanol allows us to separate loxoprofen racemate into two forms(retentate, extract). PIM and FA were used to determine the isotherms of re-and ex-loxoprofen.

A Study for Young and Middle Age People of Accommodation (청·장년층의 조절력에 관한 고찰)

  • Kim, Jeoung Hi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.129-136
    • /
    • 1998
  • I obtained result like these to practice accommodation test using Spherical Add method and Cross cylinder lens method. The 242 eyes(121 persons) in test was the young and middle age people and their age was from 19 to 41. 1. Using Spherical Add, I tested accommodation. The twenties's limits of accommodation were 9~13 Diopter, and thirties to fourties's limits of accommodation were 6~8.5 Diopter. 2. Using Cross cylinder lens in the test of accommodation twenties's average accommodation limits were appeared 6.13 Diopter~10.13 Diopter, thirties average accommodation limits were 5.75 Diopter~8.75 Diopter and fourties's average accommodation limits were 4.38 Diopter~7.25 Diopter. All men women have had more good accommodation of the horizontal direction than the vertical direction. 3. Using Spherical Add method and Cross cylinder lens method, the results of accommodation were shown like these. Accommodation that measured with spherical add method was more big than cross cylinder's accommodation measuring method. Finally I found the fact accommodation decreases as age goes.

  • PDF