• Title/Summary/Keyword: 5G-V2X

Search Result 332, Processing Time 0.031 seconds

Development of the Line Scan Diffusion Weighted Imaging at Low Tesla Magnetic Resonance Imaging System (저자장 자기공명영상시스템에서 선주사확산강조영상기법 개발)

  • Hong, Cheol-Pyo;Lee, Dong-Hoon;Lee, Do-Wan;Lee, Man-Woo;Paek, Mun-Young;Han, Bong-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • Line scan diffusion weighted imaging (LSDI) pulse sequence for 0.32 T magnetic resonance imaging (MRI) system was developed. In the LSDI pulse sequence, the imaging volume is formed by the intersection of the two perpendicular planes selected by the two slice-selective $\pi$/2-pulse and $\pi$-pulse and two diffusion sensitizing gradients placed on the both side of the refocusing $\pi$-pulse and the standard frequency encoding readout was followed. Since the maximum gradient amplitude for the MR system was 15 mT/m the maximum b value was $301.50s/mm^2$. Using the developed LSDI pulse sequence, the diffusion weighted images for the aqueous NaCl solution phantom and triacylglycerol solution phantom calculated from the line scan diffusion weighted images gives the same results within the standard error range (mean diffusivities = $963.90{\pm}79.83({\times}10^{-6}mm^2/s)$ at 0.32 T, $956.77{\pm}4.12({\times}10^{-6}mm^2/s)$ at 1.5 T) and the LSDI images were insensitive to the magnetic susceptibility difference and chemical shift.

  • PDF

Dielectric Characteristics of EVA and LLDPE Films (에틸렌비닐아세테이트와 선형저밀도폴리에틸렌 박막의 유전특성)

  • 성민우;고시현;신종열;이충호;조경순;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.783-786
    • /
    • 2000
  • In this paper, physical properties and dielectric characteristics of LLDPE and EVA which are used as a blending material to improve PE's performance are studied. LLDPE of 0.92[g/cm3] and EVA with the EVA contents of 12.5[%1 were selected as specimens, and X-ray diffraction(XRD) are used to analysis physical properties. We measured dielectric constant with the frequency range from 20[Hz] to 1 [MHz], applied voltage 6[V] and the temperature from 25[$^{\circ}C$] to 110[$^{\circ}C$]. From XRD, LLDPE has a crystallinity of 53[%] and, 46[%] for EVA. LLDPE has as low tan$\delta$ as of 10$^{-3}$ ~10$^{-4}$ and inflection point near 500[Hz]. At frequency region lower than 500[Hz], tan$\delta$ decreases with frequency and increases with temperature and it is considered to be caused by conductive carriers within specimen. Over 500[Hz], it is the reverse and we thought that it was caused by decrease of relaxation time due to Debye theory, EVA has tan$\delta$with the values of 10$^{-2}$ ~10$^{-3}$ , which is higher than that of LLDPE, and it has inflection point at 60[Hz]. It is shown that Dielectric characteristics of EVA are similar to LLDPE's.

  • PDF

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

Design and Application of Acrylic Electron Wedge for Improving Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 acrylic electron wedge의 제작 및 사용)

  • Kim, Young-Bum;Kwon, Young-Ho;Whang, Woong-Ku;Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.36-42
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20%$) at the region of junction of fields. In this study, we made Acrylic Electron Wedges to improve dose inhomogeneities(${\pm}5%$) in these junction areas and to apply it to clinical practices. All measurements were made using 6, 9, 12, 16, 20 MeV Electron beams from a linear accelerator for a $10{\times}10\;cm$ field at 100cm of SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm acquires central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance according to the acryl insert, e.g. a 1 mm thick acryl insert reduces the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced to approximately 0.2 MeV. These effects were almost Independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase(less than 3%) in the surface dose and a small increase(less than 1%) in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction at the point of penumbra width($35\;mm{\sim}40\;mm$). We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be used to improve dose uniformity at electron field junctions and it will be effectively applied to clinical practices.

  • PDF

Design and Application of Acrylic Electron Wedge to Improve Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 Acrylic Electron Wedge의 제작 및 사용)

  • Kim Young Bum;Kwon Young Ho;Whang Woong Ku;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20\%$) at the field junction area. In this study, we made Acrylic Electron Wedges to improve dose homogeneities(${\pm}5\%$) in these junction areas and considered application it to clinical practices. All measurements were made using 6, 9, 12, 16, 20MeV Electron beams from a linear accelerator for a $10{\times}10cm$ field at 100cm SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm, We acquired central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance as the thickness of the acryl insert, e.g. a 1 mm thick acryl insert reduce the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced by approximately 0.2MeV. These effects were almost independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase $(less\;than\;3\%)\;in\;the\;surface\;dose\;and\;a\;small\;Increase(less\;than\;1\%)$ in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction, and penumbra width was $35\;mm{\sim}40\;mm$. We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be use to improve dose uniformity at electron field junctions and it will be effectively applicated in clinical practices.

  • PDF

Transfer of Porcine Embryos Injected with Sperm Carrying with Exogenous DNA

  • Cho, Seong-Keun;Cho, Hwang-Yun;Park, Mi-Ryung;Park, Jong-Sik;Yoo, Jae-Gyu;Kim, Jin-Hoi
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.61-61
    • /
    • 2001
  • The main goal of this study was to produce transgenic piglets by the method of injection of sperm-mediated exogenous DNA. Spermatozoa (1$\times$106 sperm of final concentration) obtained from caudal epididymis were mixed with pBC1-hEPO (20 ng/${mu}ell$) or pcDNA3 LAC Z (20 ng/${mu}ell$), and followed by electroporation (500 V, 25 ㎌). Matured oocytes having the first polar body and dense cytoplasm were selected and centrifuged at 12,000g for 6 min. After sperm injection, the oocytes were activated electrically (1.7 ㎸/cm, 30 $\mu$ sec, single pulse) in 0.3 M mannitol solution. Eggs injected sperm were cultured in NCSU 23 medium (0.4% BSA) at 39$^{\circ}C$, 5% $CO_2$ in air for 192 h. This study were comprised 3 experiments. Experiment 1 compared the developmental efficiencies between the sperm-injected oocytes (Group 1) and further activated electrically (Group 2). Experiment 2 compared the expression of pcDNA3 LAC Z in the embryos produced by Group 1 and Group 2. Finally, experiment 3 carried out transfer of embryos (1-8 cell stage) transfected with pBC1 -hEPO into surrogate recipients synchronized by injection of combination of PG600 with hCG. The rates of cleavage and development into blastocyst stage in Group 2 were significantly higher than those of Group 1 (71.3% and 28.1% vs. 43.3% and 10.3%, respectively, p<0.05). Thirty (24.2%) out of 124 embryos analyzed in Group 2 were positive by X-gal. Similarly, in Group 1, 16.3% (8/49) were positive. After transfer of 789 embryos to 7 recipient gilts, three out of them examined by ultrasound became pregnant. One recipient is in day 50 pregnancy. On day 54 of gestation, two were carried out uterotomy in order to confirm the pregnancy One had 7 and another had 2 fetuses. We conclude that injection of sperm-mediated gene transfer will be used as a valuable tool for the production of transgenic piglets.

  • PDF

Study on the Properties of $CuInSe_2$ absorber layer from Selenization using a closed Vacuum Quartz box (진공 석영관에서 Selenization한 $CuInSe_2$ 광흡수층 특성 연 구)

  • Yang, Hyeon-Hyn;Back, Su-Ung;Kim, Han-Wool;Han, Chang-Jun;Na, Kil-Ju;Lee, Suk-Ho;So, Soon-Youl;Park, Gye-Choon;Lee, Jin;Chung, Hae-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.229-229
    • /
    • 2010
  • 본 실험에서는 $CuInSe_2$, 3원물질을 화학량론적 조성비가 되도록 박막을 제조하기 위해 각 단위원소를 원자비에 맞춰 전자선가열 진공증착기를 사용하여 Cu, In, Se 순으로 증착하였다. $10^{-3}$torr 이상의 진공석영관에서 열처리와 동시에 Selenization을 통해 제작된 $CuInSe_2$박막은 열처리온도 $250^{\circ}C$에서는 $Cu_xSe$, CuSe등의 2차상들이 나타나다가 $450^{\circ}C$이상의 고온에서 $CuInSe_2$ 단일상을 형성하였다. 이로부터 진공중에서 반응을 시켰을 때, 더 낮은 온도에서 반응이 일어나고 열역학적으로 보다 안정한 소수의 화합물들이 쉽게 형성됨을 확인할 수 있었다. 특히 $250^{\circ}C$에서는 Sphalerite 구조를 가지다가 $350^{\circ}C$이상의 온도에서 Selenization하였을 때 Chalcopyrite 구조를 가졌다. 박막이 두꺼워지면서 결정립의 크기가 커지고 응력이 작아지는 특성을 보였다. 에너지 밴드갭은($E_g$)은 Cu/In 성분비율이 클수록 작은값을 보였으며, 결절립크기가 증대되므로 결국 흡수계수가 낮아짐을 알 수 있다. 또한 두께가 증가할수록 전반적으로 흡수계수가 증가하였고 Cu/In의 성분비율이 0.97일 때 기초흡수파장은 1,169nm이고 에너지밴드갭은 1.06eV이었으며, 두께 $1.5{\mu}m$이상일 때 전반적으로 양호한 상태의 p-type $CuInSe_2$ 박막을 제작 하였다.

  • PDF

Pharmacokinetics and Lymphatic Delivery of Oligopeptide after Intramuscular Injection of Oligopeptide-bearing Liposomes to Rats (흰쥐에서 올리고펩타이드 함유 리포솜의 근육주사후 체내동태 및 임파이행)

  • Shin, Dae-Hwan;Cho, Byung-Suk;Choi, Kyu-Seok;Song, Suk-Gil;Lee, Chong-Kil;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • The purpose of the present study was to examine the pharmacokinetics and lymphatic delivery of the oligopeptide, a model peptide of X antigen epitope peptides, after the intramuscular administration of the peptide-bearing liposomes in rats. $^{14}C$-labelled peptide was used as a tracer to analyze the peptide levels in plasma, bile, urine, tissue homogenates, and lymph nodes (superior cervical nodes, brachial nodes and superior mesenteric nodes). Model peptide rapidly disappeared from the plasma by 30 min (${\alpha}$ phase) after i.v. administration, which was followed by the late disappearance. The apparent plasma half-lives ($t_{1/2({\alpha}),app}$) of the peptide at the ${\alpha}$ phase when administered at a dose of 0.2-1.0 mg/kg were about 5 min. The maximum plasma concentration ($C_{max}$) was $1.52\;{\mu}g/mL$, after the i.m. administration of the peptide at a dose of 1.0 mg/kg. The bioavailability, which was calculated from the time zero to last quantitative time, of the i.m. administered peptide was over 60%. Of the various tissues tested, the peptide was mainly distributed in the kidney after the i.m. administration. The peptide levels in the kidney 3 hr after the i.m. administration were higher than those of maximum plasma concentration ($C_{max}$). The cumulative amounts of the peptide found in the urine 72 hr after the administration of 1.0 mg/kg were 2-folder higher than those in the bile, suggesting that the peptide is mostly excreted in the urine. Moreover, the concentrations of the peptide in the lymph nodes were as high as that of the plasma and the tissues. In conclusion, the peptide concentration in the lymph nodes was maintained by 24 hr after the i.m. administration of the peptide-bearing liposomes.

A Study to Evaluate the Impact of In-Vehicle Warning Information on Driving Behavior Using C-ITS Based PVD (C-ITS 기반 PVD를 활용한 차량 내 경고정보의 운전자 주행행태 영향 분석)

  • Kim, Tagyoung;Kim, Ho Seon;Kang, Kyeong-Pyo;Kim, Seoung Bum
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.5
    • /
    • pp.28-41
    • /
    • 2022
  • A road system with CV(Connected Vehicle)s, which is often referred to as a cooperative intelligent transportation system (C-ITS), provides various road information to drivers using an in-vehicle warning system. Road environments with CVs induce drivers to reduce their speed or change lanes to avoid potential risks downstream. Such avoidance maneuvers can be considered to improve driving behaviors from a traffic safety point of view. Thus, empirically evaluating how a given in-vehicle warning information affects driving behaviors, and monitoring of the correlation between them are essential tasks for traffic operators. To quantitatively evaluate the effect of in-vehicle warning information, this study develops a method to calculate compliance rate of drivers where two groups of speed profile before and after road information is provided are compared. In addition, conventional indexes (e.g., jerk and acceleration noise) to measure comfort of passengers are examined. Empirical tests are conducted by using PVD (Probe Vehicle Data) and DTG (Digital Tacho Graph) data to verify the individual effects of warning information based on C-ITS constructed in Seoul metropolitan area in South Korea. The results in this study shows that drivers tend to decelerate their speed as a response to the in-vehicle warning information. Meanwhile, the in-vehicle warning information helps drivers to improve the safety and comport of passengers.

Molecular Epidemiological Characteristics of Vibrio Parahaemolyticus as Recently wilde-spreaded in Korea (최근 한국에서 유행하는 장염비브리오균의 분자 역학적 특성)

  • 김상숙;이희무;이중복
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.522-528
    • /
    • 2003
  • The purpose of this study is to inquire into molecular epidemiological characteristics of Vibrio parahaemolyticus. For this study, 120 strains(120 strains of Vibrio parahaemolyticus sampled from diarrhea patients) were examined and analyzed for biochemical characteristics, TDH (thermostable direct hemolysin) antibiotics sensitivity and detection of toxR, gyrE, tdh, and tds gents. G-S PCR (Group Specific Polymerase), PFGE (Pulsed-field Gel Electrophoriesis) methods were performed on the materials from patients were results. 1 Vibrio parahaemolyticus didn't grow in 0% density of NaCl, but the fact was found that those grew in 8% density of NaCl. 2. O:K serotypes of Vibrio parahaemolyticus was turned up in domestic patients was 17 types. Among those O3:K6 was the most, it was 68.3%. 3. In 18 kinds of antibiotic tests resistant against Ampicillin, Ticacillin was comparatively high. the case of resistant against Ampicillin, Ticacillin, Vancomycin at the multiple resistant was 52.5%. 4. Toxin gene tdh had only 109 strains among 120 ones isolated from patients held the genes of 199bp size, and 11 strains was negativity 5. In the test of Kanagawa toxic productivity, 107 strains among strains isolated from patients appeared to be positivity reaction 6. The strain that held trh toxin was only 3, and those among test strains had the genes of 250bp size and that had tdh, trh genes at a time were 3 strains, and TDH toxic productivity of those were 16 times, and it was weak. 7. Group Specific-PCR appeared to be useful in the confirmation of O3:K6 serotype interrelations. 8. Three strains which showed difference of 7 DNA sequence even in the same serotype were detected by the result of analyzing the regular gene, toxRS DNA sequence. These strains are differ from general strains which carry infection easily. 9. These mutual dose epidemiological relations were classified into smaller-parts through PFGE method. As a result of such classify, 3 findings were found. V. parahaemolyticus sampled from diarrhea patients were classified into 3 types. And third, the result obtained through PFGE method can be used as a useful tool in a point of molecular-epidemiological view.