• Title/Summary/Keyword: 50 Up in Peak

Search Result 194, Processing Time 0.023 seconds

Study on the Properties of $B_2O_3$-$SiO_2$and $Al_2O_3$-$SiO_2$Coating Films by the Sol-Gel Method (Sol-Gel법으로 제조한 $B_2O_3$-$SiO_2$$Al_2O_3$-$SiO_2$ 박막의 특성에 관한 연구)

  • 황규석;김병훈;최석진
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.5
    • /
    • pp.583-588
    • /
    • 1990
  • Glass films in the binary system B2O3-SiO2 and Al2O3-SiO2 were prepared on soda-lime-silica slide glass by the dip-coating technique from TEOS and boric acid or aluminum nitrate. Thickness of the films varying with viscosity and withdrawal speed were measured and effect of composition and firing temperature on the properties such as transmittance and refractive index were investigated. nM2O3.(100-n)SiO2(M=B or Al) films containing up to 20mol% B2O3 and 40mol% Al2O3 were transparent. Maximum transmittance at visible range were obtained for the sample containing 15mol% Ba2O3 and 32.5mol% Al2O3 and heat-treated at 50$0^{\circ}C$, respectively. Refractive index of the film containing 15mol% B2O3 was mininum in the B2O3-SiO2 binary system and minimal refractive index was appeared at the film containing 32.5mol% Al2O3. In IP spectra, addition of B2O3 were increased absorption peak intensity of B-O and Si-O-B bond and addition of Al2O3 were decreased absorption peak intensity of Si-O bond, respectively.

  • PDF

Nonlinear behavior of deep reinforced concrete coupling beams

  • Zhao, Z.Z.;Kwan, A.K.H.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.2
    • /
    • pp.181-198
    • /
    • 2003
  • Six large scale models of conventionally reinforced concrete coupling beams with span/depth ratios ranging from 1.17 to 2.00 were tested under monotonically applied shear loads to study their nonlinear behavior using a newly developed test method that maintained equal rotations at the two ends of the coupling beam specimen and allowed for local deformations at the beam-wall joints. By conducting the tests under displacement control, the post-peak behavior and complete load-deflection curves of the coupling beams were obtained for investigation. It was found that after the appearance of flexural and shear cracks, a deep coupling beam would gradually transform itself from an ordinary beam to a truss composed of diagonal concrete struts and longitudinal and transverse steel reinforcement bars. Moreover, in a deep coupling beam, the local deformations at the beam-wall joints could contribute significantly (up to the order of 50%) to the total deflection of the coupling beam, especially at the post-peak stage. Finally, although a coupling beam failing in shear would have a relatively low ductility ratio of only 5 or even lower, a coupling beam failing in flexure could have a relatively high ductility ratio of 10 or higher.

Electrical Properties of Pt/$LiNbO_3$/AIN/Si(100) structures (Pt/$LiNbO_3$/AIN/Si(100) 구조의 전기적 특성)

  • 정순원;정상현;인용일;김광호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.58-61
    • /
    • 2001
  • Metal-insulator-semiconductor (MIS) C-V properties with high dielectric AIN thin films showed no hysteresis and good interface properties. The dielectric constant of the AIN film calculated from the capacitance at the accumulation region in the capacitance-voltage(C-V) characteristics was about 8. The C-V characteristics of MFIS capacitor showed a hysteresis loop due to the ferroelectric nature of the LiNbO$_3$ thin films. Typical dielectric constant value of LiNbO$_3$ film of MFIS device was about 23. The memory window width was about 1.2V at the gate voltage of $\pm$5 V ranges. Typical gate leakage current density of the MFIS structure was the order of 10$^{-9}$ A/cm$^2$ at the range of within $\pm$500 kV/cm. The ferroelectric capacitors showed no polarization degradation up to about 10$^{11}$ switching cycles when subjected to symmetric bipolar voltage pulse(peak-to-peak 8V, 50% duty cycle) in the 500kHz.

  • PDF

A Clinical Study on the correlation between Bone Mineral Density (BMD) and Obesity in 480 normal adults (성인남녀 480명에서의 골밀도와 비만의 상관관계에 관한 임상적 연구)

  • Jang Soo-Jin;Kim Jeoung-Yeun;Yook Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.383-392
    • /
    • 1998
  • Osteoporosis is the most common metabolic disease of the bone, and constitutes one of the most important major pubulic health problems world wide. Therefore, in order to be helped early diagnosis, treatment and prevention of osteoporosis, measurement of Bone Mineral Density (BMD) is to be needed. Authors has analysed Bone Mineral Density (BMD) of 480 normal adults who visited woo suk unoversity Oriental Meclical Center from April 1998 to July 1998. The aims of this study is to investigate correlation between Bone Mineral Density (BMD) and age distribution, to examine the correlation between Bone Mineral Density (BMD) and Obesity. The results were as follows. 1. In distribution of age, the peak bone density of lumbar spine was noted around 30 years, and the peak bone density of the femoral neck was noted around 20 years. The age related loss of bone density follows soon after peak density. And the signifficant difference was revealed between lumbar spine and femoral neck bone density (p<0.001) 2. In distribution of sex, the bone density in male was signifficantly higher than in female (p<0.001). 3. In the correlation between Bone Mineral Density (BMD) and Obesity, Bone Mineral Density (BMD) in obese group was signifficantly higher than in non-obese group. Especially, in female from 50 up to 69 years, BMD had a positive correlation with Body mass index(BMI).

  • PDF

PMD Tolerance of 10 Gbps Modulated Signals due to SOA-Induced Chirp in SOA Booster Amplifiers

  • Jang, Ho-Deok;Kim, Kyoung-Soo;Lee, Jae-Hoon;Jeong, Ji-Chai
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.232-239
    • /
    • 2008
  • We investigated how the polarization-mode dispersion (PMD) tolerance was degraded by semiconductor optical amplifier (SOA)-induced chirp for the 10 Gb/s nonreturn-to-zero (NRZ), duobinary NRZ, return-to-zero (RZ), and carrier-suppressed RZ (CS-RZ) modulation formats. The power penalty was calculated as a measure of the system performance due to PMD for a given SOA-induced chirp. Considering only first-order PMD, all modulation formats have a similar PMD tolerance regardless of SOA-induced chirp. On the other hand, when both first- and second-order PMD are considered, the PMD tolerance of all modulation formats with the exception of the CS-RZ modulation format are degraded by SOA-induced chirp. Among all modulation formats considered here, the NRZ modulation format has the PMD tolerance with the highest sensitivity to SOA-induced chirp. When the peak-to-peak chirp induced by SOAs is $0.28{\AA}$, its PMD tolerance is degraded up to 4 dB for a differential group delay (DGD) of 50 ps. However, the PMD tolerance of the CS-RZ modulation format is largely unaffected by SOA-induced chirp.

Measurement and Analysis of Transient Voltage for an Inverter-fed Induction Motor (인버터 구동 유도전동기에서 과도전압의 측정과 분석)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Park, Dae-Won;Cho, Young-Jin;Cheon, Sang-Gyu;Choi, Su-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.6
    • /
    • pp.650-654
    • /
    • 2007
  • Induction motors are widely used as a source of driving force in electric vehicles and pulse width modulation (PWM) inverters are applied to their operation. The issue is that insulation of inverter-fed induction motors (IFMs) are more stressed than in line-powered motors by transient voltages. This paper dealt with experimental results on transient voltage produced by the PWM operation of an induction motor. The peak and the dv/dt of transient voltage depending on the length of power feeding cable and operating frequency were investigated. In the experiment, transient voltages up to 3.3PU of the rated-inverter voltage were recorded for the cable length of 50m. As the cable length is increased, the peak voltage appeared at the motor terminals increases. This phenomenon can be explained by the reflection and the transmission of travelling wave. Consequently, special care for the cable length between the motor and the inverter should be taken in the use of IFM to ensure the full life of insulation system.

Mechanical Characteristics of Cementing Plane in Concrete Repair under Various Cementing Conditions (접합조건에 따른 콘크리트 접합부의 역학적 특성)

  • 김재동;정요훈
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.362-372
    • /
    • 2003
  • Since the occurrence of Portland cement, a great number of concrete structures were constructed. But the concrete structures have their own life times, which inevitably demand repairing treatments, especially on their surface parts. Currently many various methods have been developed and are being applied fer this purpose. In this study, a newly developed method using pneumatic chipping machine and anchor pin was adopted far repair of old concrete structure and the mechanical characteristics of cementing plane between existing and new concrete were tested. Comparing the removal methods for the decrepit part of existing concrete using pneumatic chipping machine and hydraulic breaker, the peak cohesion was higher when using chipping machine at the cementing plane. On the other hand, the residual cohesion was higher for the case of breaker. Step shaped chipping on the cementing plane was effective in increasing peak cohesion, which results 14% increase in the case of 30 mm step height and 22% in 50 mm height when compared with planar chipping plane. The use of anchor pin increased the residual cohesion, which restricted shear slip on the cementing plane after peak shear stress and the tensile strength of 32% compared with that of non-anchored case. According to the combined effect of step shaped chipping of 30 mm and anchor pin with an interval of 15 cm, the peak cohesion reached up to 77% and the residual cohesion showed 180% of the ones of the fresh concrete, respectively.

Traumatic Diaphragmatic Hernia (외상성 횡경막 Hernia)

  • 정영환
    • Journal of Chest Surgery
    • /
    • v.8 no.1
    • /
    • pp.45-50
    • /
    • 1975
  • Eleven cases of traumatic diaphragmatic hernia treated at the department of thoracic and cardiovascular surgery, for the period of seven years up to February 1975, from the base of this report. 1. Peak incidence was found in the age group of one to four years and thirty to forty years, four cases in each group respectively, occupying 63.6% of all cases. 2. In all the lesions the left diaphragm was affected and the herniated organs were in order of frequency the small bowel, the large intestine, the stomach, and the spleen. 3. The methods of the adapted treatment were laparatomy in five, thoracoabdominal approach in four, and thoracotomy in two cases. 4. The mortality rate was low, only one out of eleven died It seems that the immediate appropriate treatment can bring forth the excellent outcome.

  • PDF

The Electrical Conduction and Optical Properties of ${Ta_2}{O_5}$ Thin Films by Sol-Gel Method (Sol-Gel법에 의한 ${Ta_2}{O_5}$ 박막의 전기전도와 광학적 특성)

  • 유영각
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.575-582
    • /
    • 2000
  • The Electrical conduction and optical properties of Ta$_{2}$/O$_{5}$ thin films as the insulators in DRAM capacitors were studied. Liquid Ta/sib 2//O sub 5/ were prepared by a sol-gel processing and multiple layers were applied by spin-coating up to thickness of 800$\AA$. At annealing temperature of 300~$600^{\circ}C$ the electrical conduction and specific dielectric constant were discussed the behaivor of carrier were observed by the Thermally Stimulated Current (TSC) at the temperature range of 30~23$0^{\circ}C$. At annealing temperature of 300~$600^{\circ}C$ the samples were found to be amorphous below $600^{\circ}C$ and crystalline over it. The electrical strength was about 2.2 MV/cm at 40$0^{\circ}C$. In spite of noncrystallization over 50$0^{\circ}C$ the increasing of leakage current due to pinholes and increasing creak. The refractive index was obtained maximum (2.2) at 40$0^{\circ}C$. The dielectric constant was obtained maximum(18.6) at 40$0^{\circ}C$. TSC was observed one peak at the temperature range of 30~23$0^{\circ}C$ from sample at 40$0^{\circ}C$. In the case of collecting voltage the peak size is decreased in proportion to collecting voltage and then the peak may be thought carrier to be a ionic space charge.e.

  • PDF

Nonlinear runoff during extreme storms in the Seolma-Cheon watershed

  • Kjeldsen, Thomas Rodding;Kim, Hyeonjun;Jang, Cheolhee;Lee, Hyosang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.235-235
    • /
    • 2015
  • This study investigates the impact of event characteristics on runoff dynamics during extreme flood events observed in a $8.5km^2$ experimental watershed located in South Korea. The 37 most extreme flood events with event rainfall in excess of 50 mm were analysed using an event-based rainfall-runoff model; the Revitalised Flood Hydrograph (ReFH) routinely used for design flood estimation in the United Kingdom. The ReFH model was fitted to each event in turn, and links were investigated between each of the two model parameters controlling runoff production and response time, respectively, and event characteristics such as rainfall depth, duration, intensity and also antecedent soil moisture. The results show that the structure of the ReFH model can effectively accommodate any nonlinearity in runoff production, but that the linear unit hydrograph fails to adequately represent a reduction in watershed response time observed for the more extreme events. By linking the unit hydrograph shape directly to rainfall depth, the consequence of the observed nonlinearity in response time is to increase design peak flow by between 50% for a 10 year return period, and up to 80% when considering the probable maximum flood (PMF).

  • PDF