• Title/Summary/Keyword: 5 차 구동프로파일

Search Result 2, Processing Time 0.018 seconds

Development of Improved 5th Order Motion Profile for Low Vibration and High Speed (저진동, 고속특성을 가지는 개선된 5차 모션 프로파일의 설계)

  • So, Byeong-Kwan;Tae, Won-Hyeong;Kim, Jung-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1110-1118
    • /
    • 2012
  • In this study, for reducing the residual vibration in high speed motion control stage, an improved 5th order polynomial motion profile was developed. When a stage is moving, the current through the motor coils has the same profile of input motion profile of acceleration, therefore the characteristics of the acceleration input profile directly affect on the performance of the amplifier that includes the current control loop. Commonly low cost amplifier and motor has a narrow current control bandwidth, therefore the proposed algorithm was designed based on this practical constraint. Simulation and experimental results showed that the proposed algorithm clearly has low residual vibration characteristics than conventional 5th order polynomial motion profile on the same drive condition.

The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals (만곡된 레진 모형 근관에서 4종의 엔진 구동형 니켈-티타늄 기구의 근관 중심율 유지 능력)

  • Ku, Jae-Hoon;Chang, Hoon-Sang;Chang, Seok-Woo;Cho, Hwan-Hee;Bae, Ji-Myung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.113-118
    • /
    • 2006
  • The aim of this study was to evaluate the ability of newly marketed NRT instruments to maintain the original root canal configuration and curvature during preparation in comparison with the three existing instruments in simulated root canals. Simulated canals in resin blocks were prepared with ProFile. K3, ProTaper and NRT instrument (n = 10 canals in each case). Pre- and post-operative images were recorded, and assessment of canal shape was completed with a computer image analysis program. The data were analyzed statistically using the One-way ANOVA followed by Duncan s test. The ability or instruments to remain centered in prepared canals at 1-, 2-mm levels was significantly better in ProFile groups than in other groups (p < 0.05). The change of centering ratio in NRT groups at 5-mm level was significantly greater than ProFile group and at 6- and 7-mm level than all other groups (p < 0.05). Although the NRT system was comparable to other systems in regards to its ability to maintain the canal configuration of apical portion, this system was more influenced by the mid-root curvature due to its stainless-steel files for coronal preflaring.