• 제목/요약/키워드: 4D-CT

검색결과 576건 처리시간 0.037초

Research Activities at National Institute of Radiological Sciences in Development of Radiological Apparatus

  • Endo, Masahiro
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.3-5
    • /
    • 2002
  • This paper describes research activities at National Institute of Radiological Sciences (NIRS), Japan in development of radiological apparatus, which cover 4-dimensinal (4D) CT, next-generation PET and several progresses in heavy-ion irradiation system at HIMAC (Heavy Ion Medical Accelerator in Chiba).

  • PDF

위암 진단에 있어서의 CT 위장 조영술과 상부위장관 조영술과의 비교 (Usefullness of CT Gastrography and Vurtual Gastroscopy using Computed Tomography in Detection of Gastric Cancer)

  • 백용해;이순진;이지연;노재형;손태성;김성;김용일
    • Journal of Gastric Cancer
    • /
    • 제3권4호
    • /
    • pp.195-200
    • /
    • 2003
  • Purpose: Advancement of computed tomography (CT) hardware and software has allowed thin section scanning and reconstruction of fascinating 2-dimentional (2D) and 3- dimentional (3D) images. Especially, the reconstruction of 3D images of gastrointestinal tract has been used in the detection and diagnosis of pre-malignant and malignant diseases. To compare the efficacy of CT gastrography with conventional upper gastrointenstinal series (UGIs) in gastric cancer patients. Materials and Methods: During Nov. 2002 and Mar. 2003, twenty-seven patients who had gastric cancer received both double contrast upper GI series and CT gastrography prior to radical surgery. Among these patients, nineteen had early gastric cancer (EGC) and 8 had advanced gastric cancer (AGC). Fifteen patients were male and 12 were female. The mean age was 54 yrs (range, $27\∼75$ yrs). The patients were placed on NPO and Stomach was distended with gas in fasting state prior to CT scanning. Double contrast upper GI series were performed as routine manual. CT scan was conducted in all patients using 8 or 16-channel multidetector CT in this study. The collimation and reconstruction for CT scanning were set at 2.5 mm and 1.25 mm, respectively. CT scanning was performed in the supine position. For image processing, CT gastrography, in which raysum and surface rendering images were constructed, virtual and 2D image in coronal and sagittal images were performed. The detectability of gastric cancer was assessed between UGIs and CT gastrography. Results: In AGCs, the detection rate of cancer using CT gastrography and virtual gastroscopy was higher than EGC cases. However, CT gastrography and virtual gastroscopy showed less favorable results than UGIs. Even though only a small number of cases had been studied, we might conclude that CT gastrography and virtual gastroscopy could replace UGIs in the detection of AGC cases. Conclusion: The detection rate used with CT gastrography and Virtual gastroscopy is not better than that of UGIs in early gastric cancer, however, in advanced gastric cancer cases, it is nearly equal to that of UGIs.

  • PDF

Safety of Administering Intravenous CT Contrast Agents Repeatedly or Using Both CT and MRI Contrast Agents on the Same Day: An Animal Study

  • Heejin Bae;Hyewon Oh;Ga Bin Park;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • 제25권3호
    • /
    • pp.257-266
    • /
    • 2024
  • Objective: To investigate molecular and functional consequences of additional exposures to iodine- or gadolinium-based contrast agents within 24 hours from the initial intravenous administration of iodine-based contrast agents through an animal study. Materials and Methods: Fifty-six Sprague-Dawley male rats were equally divided into eight groups: negative control, positive control (PC) with single-dose administration of CT contrast agent, and additional administration of either CT or MR contrast agents 2, 4, or 24 hours from initial CT contrast agent injection. A 12 µL/g of iodinated contrast agent or a 0.47 µL/g of gadolinium-based contrast agent were injected into the tail vein. Serum levels of blood urea nitrogen, creatinine, cystatin C (Cys C), and malondialdehyde (MDA) were measured. mRNA and protein levels of kidney injury molecule-1 (KIM-1) and neutrophil gelatinase-associated lipocalin (NGAL) were evaluated. Results: Levels of serum creatinine (SCr) were significantly higher in repeated CT contrast agent injection groups than in PC (0.21 ± 0.02 mg/dL for PC; 0.40 ± 0.02, 0.34 ± 0.03, and 0.41 ± 0.10 mg/dL for 2-, 4-, and 24-hour interval groups, respectively; P < 0.001). There was no significant difference in the average Cys C and MDA levels between PC and repeated CT contrast agent injection groups (Cys C, P = 0.256-0.362; MDA, P > 0.99). Additional doses of MR contrast agent did not make significant changes compared to PC in SCr (P > 0.99), Cys C (P = 0.262), and MDA (P = 0.139-0.771) levels. mRNA and protein levels of KIM-1 and NGAL were not significantly different among additional CT or MR contrast agent groups (P > 0.05). Conclusion: A sufficient time interval, probably more than 24 hours, between repeated contrast-enhanced CT examinations may be necessary to avoid deterioration in renal function. However, conducting contrast-enhanced MRI on the same day as contrast-enhanced CT may not induce clinically significant kidney injury.

컴퓨터단층촬영(CT) 기술 동향 (Computed Tomography Technology)

  • 이정원;이수열;유동훈
    • 전자통신동향분석
    • /
    • 제25권4호
    • /
    • pp.60-68
    • /
    • 2010
  • CT는 종래의 엑스선 촬영 기법으로 얻은 인체 내부의 투영 데이터를 컴퓨터로 재구성하여 단층영상을 만들어 내는 기술이다. 1972년 최초의 상용화 CT가 개발된 이후로 촬영 속도 개선의 측면에서 비약적인 발전을 이루었다. 겐트리 구동 방식의 발전과 Spiral CT, MDCT 기술의 도입이 스캔 시간 단축에 큰 역할을 하였다. 특히 MDCT의 개발로 다양한 임상적 활용이 가능해졌다. 한편 O-arm CT 기술은 CT를 공간적 제약에서 벗어나게 하였다. 이는 CT가 수술실 현장에서 활용될 수 있다는 임상적 의미를 가진다. O-arm CT는 즉석에서 활용되어야 하므로 촬영과 동시에 영상이 실시간으로 재구성되는 것도 중요하다. 최근에 도입되기 시작한 GPU 프로그래밍 기술은 고성능 GPU 하드웨어의 발전을 등에 업고 실시간 CT 재구성을 가능하게 할 것으로 보인다.

K-각 영상을 이용한 스펙트럼 전산화단층촬영 기반 3차원 융합진단영상화에 관한 연구 (3D Fusion Imaging based on Spectral Computed Tomography Using K-edge Images)

  • 김번영;이승완;임도빈
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.523-530
    • /
    • 2019
  • 본 연구의 목적은 광자계수검출기 기반 스펙트럼 전산화단층촬영을 이용하여 K-각 영상을 획득하고, 이를 통해 3차원 융합진단영상을 구현하여 임상적 이용 가능성을 평가하고자 하였다. 실험을 통한 K-각 영상획득을 위해 스펙트럼 전산화단층촬영 시스템을 이용하였다. 희석된 iodine과 gadolinium 조영제가 주입된 6개의 튜브를 돼지고기에 삽입하여 팬텀을 제작하였다. 100 kVp 관전압과 $500{\mu}A$ 관전류 조건에서 발생된 X-선을 이용하였으며, iodine과 gadolinium의 K-각 흡수에너지를 고려한 35 및 52 keV에 저 에너지 문턱값을 설정하여 K-각 영상을 획득하였다. 융합진단영상은 일반적인 전산화단층촬영 영상과 스펙트럼 전산화단층촬영을 통해 획득한 iodine 및 gadolinium 영상을 정합하여 획득하였다. 두 가지 조영제 기반 융합진단영상의 CNR은 일반적인 CT보다 평균적으로 6.76-14.9배 높았으며, 3차원 융합진단영상은 각 조영제의 물질 지도 정보를 제공할 수 있었다. 따라서 본 연구에서 제안하는 방법을 통해 전산화단층영상의 화질을 향상시킬 수 있으며 특정 물질의 추가적인 정보를 제공을 통해 진단의 효율성을 증가시킬 수 있다.

Automated Lung Segmentation on Chest Computed Tomography Images with Extensive Lung Parenchymal Abnormalities Using a Deep Neural Network

  • Seung-Jin Yoo;Soon Ho Yoon;Jong Hyuk Lee;Ki Hwan Kim;Hyoung In Choi;Sang Joon Park;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.476-488
    • /
    • 2021
  • Objective: We aimed to develop a deep neural network for segmenting lung parenchyma with extensive pathological conditions on non-contrast chest computed tomography (CT) images. Materials and Methods: Thin-section non-contrast chest CT images from 203 patients (115 males, 88 females; age range, 31-89 years) between January 2017 and May 2017 were included in the study, of which 150 cases had extensive lung parenchymal disease involving more than 40% of the parenchymal area. Parenchymal diseases included interstitial lung disease (ILD), emphysema, nontuberculous mycobacterial lung disease, tuberculous destroyed lung, pneumonia, lung cancer, and other diseases. Five experienced radiologists manually drew the margin of the lungs, slice by slice, on CT images. The dataset used to develop the network consisted of 157 cases for training, 20 cases for development, and 26 cases for internal validation. Two-dimensional (2D) U-Net and three-dimensional (3D) U-Net models were used for the task. The network was trained to segment the lung parenchyma as a whole and segment the right and left lung separately. The University Hospitals of Geneva ILD dataset, which contained high-resolution CT images of ILD, was used for external validation. Results: The Dice similarity coefficients for internal validation were 99.6 ± 0.3% (2D U-Net whole lung model), 99.5 ± 0.3% (2D U-Net separate lung model), 99.4 ± 0.5% (3D U-Net whole lung model), and 99.4 ± 0.5% (3D U-Net separate lung model). The Dice similarity coefficients for the external validation dataset were 98.4 ± 1.0% (2D U-Net whole lung model) and 98.4 ± 1.0% (2D U-Net separate lung model). In 31 cases, where the extent of ILD was larger than 75% of the lung parenchymal area, the Dice similarity coefficients were 97.9 ± 1.3% (2D U-Net whole lung model) and 98.0 ± 1.2% (2D U-Net separate lung model). Conclusion: The deep neural network achieved excellent performance in automatically delineating the boundaries of lung parenchyma with extensive pathological conditions on non-contrast chest CT images.

Preoperative CT Navigation of Perigastric Vessel Anatomy for Gastrectomy

  • Baek, Song-Ee;Hyung, Woo Jin;Lim, Joon Seok
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권1호
    • /
    • pp.41-44
    • /
    • 2014
  • The aim of this report is showing the case that we could give exact navigation of perigastric vessels for gastrectomy with 3D CTA. A 74-year-old male patient visited hospital with gastric cancer. Early gastric cancer, type IIb was found at stomach antrum great curvature side. Before surgery, he underwent 3D CT angiography. 3D volume rendering images and MIP images were made by post processing. He had replaced Lt. hepatic artery arising from Lt. gastric artery. Surgeon could get patient's specific vascular anatomy before surgery including surgically relevant anatomical distance and direction and could finish gastrectomy within 4 hours and just 53ml blood loss.

인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가 (Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom)

  • 장은성;강수만;이철수
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.33-39
    • /
    • 2009
  • 목 적: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하면 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. Detected offsets은 실제로 적용된 인체팬톰(Rando phantom) 위치의 오차와 비교되어 진다. 이후, 인체 팬톰은 detected 오차에 근거하여 couch를 움직여 위치선정 되었다. 또한 인체팬톰 위치 결정의 실측값과 이론값 오차값들을 비교하였으며, OBI를 사용하고 있는 KV X선영상의 2D와 CBCT의 3D 타켓 위치 정확성 평가하고자 한다. 대상 및 방법: 신체 내부 구조가 모사된 팬톰(The Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)을 사용하여 실제방사선 치료와 동일한 과정을 따라 모의치료(SIMULATION) 및 치료계획(RTP)을 시행한 후 치료 데이블 위에 인체 팬톰을 셋업한다. 정확히 위치가 재현된다고 가정되는 인체팬톰에 대해 3가지 방법으로 실험을 했는데 X, Y, Z축의 변화에 따라 셋업 오차를 측정했고 각각의 실험은 10회씩 반복되어 오차의 표준 편차를 구했다. DigiPas DWL-80G는 기울기의 각을 결정하기 위해 사용하였으며, 2D/2D 및 3D/3D정합의 실측치와 측정치를 비교 분석 하였다. 결 과: 온보드 영상장치로 획득한 정면 및 측면 kv x선 영상과 모의치료시 디지털 재구성 기준영상과의 2차원/2차원 정합시, 팬톰의 X, Y, Z 편차 평균값은 lat 0.12 cm, long -0.66 cm, vert 0.07 cm이며, 각도의 변화를 주었을 때 편차의 평균값은 lat -0.5 cm, long -0.3 cm, 팬톰의 몸을 약간 튼 상태에서의 편차 평균값은 각각 lat -0.5 cm, long 0.2 cm, vert -0.6 cm으로 나타났다. 또한 콘빔CT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3차원/3차원 정합에서 팬톰의 3가지 방법에서 편차의 평균 detection error와 표준편차는 lateral $0.5{\pm}0.4\;mm$, longitudinal $0.8{\pm}0.5\;mm$, vertical $0.4{\pm}0.3\;mm$로 각각 0-10 mm의 범위이다. Residual error에 해당되는 positioning couch shift 변수는 $0.6{\pm}0.3\;mm$, $0.5{\pm}0.3\;mm$, $0.3{\pm}0.1\;mm$이다. 20-50 mm까지 longitudinal shift에 의한 평균 detection error는 각각 lateral $0.4{\pm}0.2\;mm$, longitudinal $0.3{\pm}0.2\;mm$, vertical $0.3{\pm}0.3\;mm$이다. Residual error는 $0.6{\pm}0.3\;mm$, $0.6{\pm}0.2\;mm$, $0.4{\pm}0.1\;mm$이다. Detection error는 모두 0.0~0.6 mm 범위이다. Residual error는 0.3~0.9 mm 범위로 나타났다. 결 론: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하여 표적위치의 정확성을 평가하였다. 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. 그러므로 OBI 및 CBCT를 이용한 2D/2D 및 3D/3D 정합은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 할 것으로 평가된다.

  • PDF

PET/CT검사에서 Dose Modulation Technic 적용시 BMI에 따른 선량 감소율 분석 (Analysis of Dose Reduction Rate with Dose Modulation Technic Depending on BMI)

  • 김정욱;박세윤;조영준;박종엽
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.25-28
    • /
    • 2012
  • PET/CT에서의 환자의 피폭선량을 줄이기 위한 많은 연구가 진행되고 있다. 본 연구는 2012년 2월부터 2012년 3월까지 PET/CT검사를 위해 본원 핵의학과에 내원한 환자 149명(평균연령 $58{\pm}12.4$세)을 대상으로 하였고 장비는 Biograph True Point 40 (Siemens, USA)과 Gemini TF 64 (Philips, Cleveland)를 사용하였다. SIEMENS사의 Care Dose 4D를 사용하여 75명의 환자를 BMI 지수에 따라 세 집단으로 나누어 선량 감소율과 CTDI를 측정하였고 PHILIPS사의 D-dom을 이용하여 74명의 환자를 세 집단으로 나누어 선량 감소율과 CTDI를 측정하였다. 각 장비별로 세 집단 간의 측정값들이 유의한 차이를 보이는지 알아보기 위하여 SPSS Ver.18.0 통계분석프로그램을 이용하였다. 각각의 집단별로 평균값을 비교한 결과 Care Dose 4D를 사용했을 때 선량 감소율, CTDI 모두 p-value가 0.000으로서 통계적으로 유의한 차이가 있었다. D-dom을 사용했을 때 집단 간의 p-value는 선량 감소율 0.284, CTDI 0.226으로서 p>0.05이므로 집단 간의 유의한 차이가 없었다. 집단별로 평균 선량 감소율과 CTDI를 분석한 결과 Care Dose 4D를 사용했을 때 각각 정상집단에서 53.4%, 5.3 mGy, 과체중집단에서 49.5%, 5.8 mGy, 비만 집단에서 42.0%, 6.6 mGy로 나타났다. 반면에 D-dom을 사용하였을 때는 각각 정상 집단에서 22.7%, 4.5 mGy, 과체중 집단에서 22.1%, 4.6 mGy, 비만 집단에서 22.9%. 4.5 mGy로 나타났다. D-dom의 원리인 투사각도에 따른 선량조절은 환자의 비만도에 영향이 많지 않음을 알 수 있었다. 그리고 Care Dose 4D의 경우에는 투사각도에 따른 선량조절뿐만 아니라 환자 장축의 감쇠계수에 따른 선량조절, 환자 사이즈에 따른 선량조절 원리를 사용하고 있다. 그러므로 환자 장축의 감쇠계수에 따른 선량조절과 환자 크기에 따른 선량조절 원리가 환자의 비만도에 영향이 있다고 생각된다. 비록 같은 BMI 집단 간에 환자의 체형에 따른 오차가 있다고 여겨지지만, 앞으로 더욱더 많은 연구가 이루어진다면 Dose Modulation Technic이 PET/CT검사에서 환자의 피폭선량을 줄이는데 많은 도움이 될 것으로 생각된다.

  • PDF