• 제목/요약/키워드: 4D radiation therapy

Search Result 293, Processing Time 0.032 seconds

The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer (식도암 치료에 있어 관내근접치료의 역할)

  • Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon;Chu Sung Sil;Chung Eun Ji;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.331-338
    • /
    • 1995
  • Purpose : To evaluate our clinical experience with the combination of teletherapy and intraluminal brachytherapy in patients with unresectable or inoperable esophageal cancers. Materials and Methods : From Nov 1989 to Mar 1993, twenty patients with esophageal cancer were treated with radical radiotherapy and intraluminal brachytherapy at Yonsei Cancer Center. All patients had squamous histolgy and stage distribution was as follows: stage II, 4($20{\%}$)patients; III, 15 ($75{\%}$)patients; IV, 1($5{\%}$)patients. A dose of S-12Gy/1-3weeks with intraluminal brachytherapy (3-5Gy/fraction) to 5mm from the outside of the esophageal tube using high dose rate Iridium-192 remotely afterloading brachytherapy machine was given 2 weeks after a total dose of 59-64Gy with external radiotherapy. Induction chemotherapy using cisplatin and 5-FU was performed in 13 patients with median 3 cycles(1-6 cycles), Response rate, local control rate, survival and complications were analysed retrospectively. Results : Two-year overall survival rate and median survival were $15.8{\%}$ and 13.5 months. Response rates were as follows complete remission(CR) 5($25{\%}$): partial remission a(PRa) 7($35{\%}$): partial remission b(PRb) 7($35{\%}$), no response(NR) 1($5{\%}$). Patterns of failure were as follows; local failure 13($65{\%}$), local and distant failure 3($15{\%}$), distant failure 0($0{\%}$). Ultimate local control rate was $20{\%}$. Treatment related complications included esophageal ulcer in two patients and esophageal stricture in one. Conclusion : Though poor local conrol rate, median survival was improved as compared with previous results of radiation therapy alone(8months) and chemoradiation combined treatment(11 months) in Yonsei Cancer Center High-dose-rate intraluminal brachytherapy following external irradiation is an effective treatment modality with acceptable toxicity in esophageal cancer.

  • PDF

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

Impact of Adjuvant Chemoradiation Therapy on the Postoperative 5-year Survival Rates for Stage-II Gastric Cancer (2기 위암환자의 수술 후 보조 항암요법 및 방사선 치료가 생존율에 미치는 영향)

  • Hong, Seong-Kweon;Choi, Min-Gew;Baik, Yong-Hae;Noh, Jae-Hyung;Sohn, Tae-Sung;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.5 no.4 s.20
    • /
    • pp.281-287
    • /
    • 2005
  • Purpose: This study was conducted to evaluate the effectiveness and the role of post-operative adjuvant chemoradiation therapy in a stage-II (UICC, 1997) primary gastric cancer. Materials and Methods: From September 1994 to December 2004, 954 stage-II gastric-cancer patients were seen, and all of them underwent a curative resection with extensive (D2) lymph-node dissection. The chemotherapy consisted of fluorouracil $(400mg/m^2)$ plus leucovorin $(20mg/m^2)$ for 5 days, followed by 4,500 cGy of radiotherapy for 5 weeks with fluorourcil and leucovorin on the first 4 days and the last 3 days of radiotherapy. Two five-day cycles of chemotherapy were given four weeks after the completion of radiotherapy. The Kaplan-Meier method was used to estimate the survival rates. To assess the importance of potential prognostic factors, we performed univariate and multivariate analyses using a log-rank test and Cox's proportional hazards regression model. A P value <0.05 was considered significant. Results: Univariate analysis revealed that age, tumor size, gross type, surgical method, and postoperative adjuvant therapy had statistical significance. Among these factors, age, surgical method, tumor size, surgical method, and postoperative adjuvant therapy were found to be independent prognostic factors by using a multivariate analysis. The postoperative adjuvant chemotherapy group and the chemoradiation therapy group had survival benefit compared to the surgery-only group. However the chemoradiation therapy group had no significant survival benefit compared to the chemotherapy group. Conclusion: The postoperative adjuvant therapy in stage-II gastric-cancer patients had significant benefit. Therefore, postoperative adjuvant chemoradiation therapy has an acceptable effect. A large-scale, randomized study is needed to evaluate the effectiveness and the role of postoperative radiation therapy.

  • PDF

A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems (방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램)

  • Kim, Hee-Jung;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Kim, Jung-In;Lee, Sang-Won;Oh, Heon-Jin;Lim, Chun-Il;Kim, Il-Han;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within ${\pm}3%$ for the phantom and ${\pm}5%$ for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.

  • PDF

Radical Radiotherapy for Carcinoma of the Prostate (전립선암의 근치적 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.40-44
    • /
    • 2001
  • Purpose : To evaluate effect and tolerance of external beam radiotherapy for carcinoma of the prostate and define the optimal radiotherapeutic regimen. Materials and methods : We retrospectively analyzed the records of 60 patients with prostate cancer who were treated with external beam radiotherapy with curative intent in our institution between September, 1987 and March, 2000. Histologic diagnosis was established by transurethral resection or ultrasonography guided biopsy. The major presenting symptoms were a nodule at routine prostatic examination and frequency and urgency of urination, along with dysuria. The median age was 63 years with range of 51 to 87 years. There were 6 patients in Stage A, 20 in Stage 8, 26 in Stage C, and 8 in Stage Dl. All patients were treated with megavoltage equipment producing 10 MV photons. The 4 field pelvic brick technique was used to a dose of 45 Gy or 50.4 Gy at 1.8 Gy per day in 5 to 6 weeks, after which a small boost field was delivered 2.0 Gy per day to a total dose of 66 to 70 Gy. The follow-up period ranged from 1 to 8 years. Results : Actuarial 5-year and 7-year survival rates for Stage A, B, C, and D1 were $100\%\;and\;84\%$, $83\%\;and\;72\%$, $67\%\;and\;54\%$, and $v$, respectively. The corresponding 5-year and 7-year relapse free survival rates were $84\%\;and\;84\%$, $77\%\;and\;67\%$, $48\%\;and\;40\%$, and $33\%\;and\;25\%$, respectively. Relapse free 5-year survival rates for Stage B were $80\%,\;80\%,\;and\;50\%$ for well, moderately, and poorly differentiated tumors, respectively. These were $64\%,\;44\%,\;and\;33\%$ for Stage C, respectively. The local control rates at 5 years were $84\%,\;85\%,\;78\%,\;and\;60\%$ for Stage A, B, C, and D1, respectively. Mild to moderate complications were observed in $22\%$ of patients. Severe complications requiring surgical procedures were documented in only $3\%$ of patients. Conclusion : This study confirms that external beam irradiation is an effective and safe treatment for prostatic cancer, providing long-term local control and good survival with acceptable complications.

  • PDF

Hyperfractionated Radiotherapy and Concurrent Chemotherapy for Stage III Unresectable Non Small Cell Lung Cancer : Preliminary Report for Response and Toxicity (절제 불가능한 제 3기 비소세포성 페암의 다분할 방사선 치료와 MVP 복합 항암요법의 동시 치료에 대한 예비적 결과)

  • Choi, Eun-Kyung;Kim, Jong-Hoon;Chang, Hye-Sook;Kim, Sang-We;Suh, Cheol-Won;Lee, Kyoo-Hyung;Lee, Jung, Shin;Kim, Sang-Hee;Ko, Youn-Suk;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Song, Koun-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.157-162
    • /
    • 1995
  • Lung cancer study group at Asan Medical Center has conducted the second prospective study to determine the efficacy and feasibility of MVP chemotherapy with concurrent hyperfractionated radiotherapy for Patients with stage III unresectable non-small cell lung cancer(NSCLC). All eligible Patients with stage III unresectable NSCLC were treated with hyperfractionated radiotherapy(120 cGy/fx BID. 6480 cGy/54fx) and concurrent 2 cycles of MVP(Mitomycin C $6mg/m^2,$ d2 & d29.Vinblastine $6mg/m^2,$ d2 & d29, Cisplatin $60mg/m^2,$ dl & d28) chemotherapy. Between Aug. 1993 and Nov. 1994, 62 patients entered this study; $6(10\%)$ had advanced stage IIIa and $56(90\%)$ had IIIb disease including 11 with pleural effusion and 10 with supraclavicular metastases. Among 62 patients, $48(77\%)$ completed planned therapy. Fourteen patients refused further treatment during chemoradiotherapy. Of 46 patients evaluable for response, $34(74\%)$ showed major response including $10(22\%)$ with complete and $24(52\%)$ with partial responses. Of 48 patients evaluable for toxicity, $13(27\%)$ showed grade IV hematologic toxicity but treatment delay did not exceed 5 days Two patients died of sepsis during chemoradiotherapy. Severe weight loss(more than $10\%)$ occurred in 9 patients$(19\%)$ during treatment. Nine patients$(19\%)$ developed radiation pneumonitis Six of these patients had grade 1 (mild) Pneumonitis with radiographic changes within the treatment fields Three other patients had grade 11 Pneumonitis, but none of these patients had continuous symptoms after steroid treatment. Concurrent chemoradiotherapy for patients with advanced NSCLC was well tolerated with acceptable toxicity and achieved higher response rates than the first study, but rather low compliance $rate(77\%)$ in this study is worrisome. We need to improve nutritional support during treatment and to use G-CSF to improve leukopenia and if necessary. supportive care will be given as in patients, Longer follow-up and larger sample size is needed to observe survival advantage.

  • PDF

The Feasibility Study of MRI-based Radiotherapy Treatment Planning Using Look Up Table (Look Up Table을 이용한 자기공명영상 기반 방사선 치료계획의 타당성 분석 연구)

  • Kim, Shin-Wook;Shin, Hun-Joo;Lee, Young-Kyu;Seo, Jae-Hyuk;Lee, Gi-Woong;Park, Hyeong-Wook;Lee, Jae-Choon;Kim, Ae-Ran;Kim, Ji-Na;Kim, Myong-Ho;Kay, Chul-Seung;Jang, Hong-Seok;Kang, Young-Nam
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.237-242
    • /
    • 2013
  • In the intracranial regions, an accurate delineation of the target volume has been difficult with only the CT data due to poor soft tissue contrast of CT images. Therefore, the magnetic resonance images (MRI) for the delineation of the target volumes were widely used. To calculate dose distributions with MRI-based RTP, the electron density (ED) mapping concept from the diagnostic CT images and the pseudo CT concept from the MRI were introduced. In this study, the look up table (LUT) from the fifteen patients' diagnostic brain MRI images was created to verify the feasibility of MRI-based RTP. The dose distributions from the MRI-based calculations were compared to the original CT-based calculation. One MRI set has ED information from LUT (lMRI). Another set was generated with voxel values assigned with a homogeneous density of water (wMRI). A simple plan with a single anterior 6MV one portal was applied to the CT, lMRI, and wMRI. Depending on the patient's target geometry for the 3D conformal plan, 6MV photon beams and from two to five gantry portals were used. The differences of the dose distribution and DVH between the lMRI based and CT-based plan were smaller than the wMRI-based plan. The dose difference of wMRI vs. lMRI was measured as 91 cGy vs. 57 cGy at maximum dose, 74 cGt vs. 42 cGy at mean dose, and 94 cGy vs. 53 at minimum dose. The differences of maximum dose, minimum dose, and mean dose of the wMRI-based plan were lower than the lMRI-based plan, because the air cavity was not calculated in the wMRI-based plan. These results prove the feasibility of the lMRI-based planning for brain tumor radiation therapy.

Comparison of Film Measurements, Convolution$^{}$erposition Model and Monte Carlo Simulations for Small fields in Heterogeneous Phantoms (비균질 팬텀에서 소조사면에 대한 필름측정, 회선/중첩 모델과 몬테 카를로 모사의 비교 연구)

  • 김상노;제이슨손;서태석
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.89-95
    • /
    • 2004
  • Intensity-modulated radiation therapy (IMRT) often uses small beam segments. The heterogeneity effect is well known for relatively large field sizes used in the conventional radiation treatments. However, this effect is not known in small fields such as the beamlets used in IMRT. There are many factors that can cause errors in the small field i.e. electronic disequilibrium and multiple electron scattering. This study prepared geometrically regular heterogeneous phantoms, and compared the measurements with the calculations using the Convolution/Superposition algorithm and Monte Carlo method for small beams. This study used the BEAM00/EGS4 code to simulate the head of a Varian 2300C/D. The commissioning of a 6MV photon beam were performed from two points of view, the beam profiles and depth doses. The calculated voxel size was 1${\times}$1${\times}$2$\textrm{cm}^2$ with field sizes of 1${\times}$1$\textrm{cm}^2$, 2${\times}$2$\textrm{cm}^2$, and 5${\times}$5$\textrm{cm}^2$. The XiOTM TPS (Treatment Planning System) was used for the calculation using the Convolution/Superposition algorithm. The 6MV photon beam was irradiated to homogeneous (water equivalent) and heterogeneous phantoms (water equivalent + air cavity, water equivalent + bone equivalent). The beam profiles were well matched within :t1 mm and the depth doses were within ${\pm}$2%. In conclusion, the dose calculations of the Convolution/Superposition and Monte Carlo simulations showed good agreement with the film measurements in the small field.

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF