• Title/Summary/Keyword: 40Hz

Search Result 951, Processing Time 0.026 seconds

Experiments of Micro Jet Injection for Bio-Medical Application (바이오 분야 적용을 위한 마이크로 젯 인젝션 실험)

  • Ham, Young-Bog;An, Byeung-Cheol;Trimzi, Mojiz Abbas;Kim, Jong-Dae;Lee, Gi-Tae;park, Jung-Ho;Yun, So-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.681-687
    • /
    • 2016
  • It is essential for micro jet injectors in the biomedical sector to operate under high pressure. High pressure injection, however, is accompanied by high volumes. On/Off valves that can be operated at high speeds have been used to address this problem. In this research, piezoelectric actuators which have a response frequency of the order of hundreds of kilohertz were used as the On/Off valve and experiments were applied. Researchers developed a controller to precisely manipulate the piezoelectric valve with various waveforms. They also fabricated five types of nozzles to consider the effect of nozzle type on injection. This allowed researchers to manipulate and confirm factors that can affect the injection volume and force. Results of this experiment have shown how to decrease the injection volume and increase the injection force. and it is predicted that the optimized injection volume and force value can be determined depending on the skin type.

Development of welding process to rootpass for U-Groove without gap in pipe 1GR butt welding (파이프 1G 회전 맞대기 용접에서 갭 없는 U-그루브의 루트패스 용접공정 개발)

  • Son, Chang-Hui;Kim, Nam-Gyu;Cho, Sang-Myeong
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.40-40
    • /
    • 2010
  • 산업현장에서는 파이프 또는 탱크류의 1GR용접에서 안정적인 이면비드를 가지는 루트패스 용접을 위해 2~3mm의 루트갭을 띄우고 용접봉 또는 필러와이어를 사용하는 TIG용접을 주로 한다. TIG용접은 고품질의 이면비드가 얻어지며, 용접인자의 제어가 쉽다는 장점이 있어 루트패스 용접에 많이 사용되고 있지만, 루트갭을 띄우면 이면비드는 잘 얻어지지만 용착금속량이 많아지게 되어 제작원가가 상승되고, 또한 소모성 와이어를 사용하는 GMAW에 비해 생산성이 낮다. 따라서, 안정적인 이면비드를 가지면서 생산성이 높은 1GR GMAW 루트패스 용접공정의 개발이 요구되지만, 이 경우도 루트갭이 2~3mm로 정해져 있으면 Fit-up공정에서 공수가 많이 필요하므로 근본적으로 루트갭이 없는 그루브에 대한 루트패스 용접이 더 바람직하다. 본 연구에서는 루트면 2.7mm를 가지는 U-그루브의 갭 없는 루트패스 용접에서 안정적인 이면비드가 형성되는 조건을 검토하기 위해 2.7t의 평판에 대하여 경사상진 각을 주고 기초 실험 후, U-그루브 맞대기 용접 실험을 진행하였다. 이 때, 경사상진 각은 용융금속이 중력으로 인해 아크 후방으로 밀리게 되고, 그로 인해 아크가 모재에 직접 닿게 되어 용입이 더 깊게되므로, 이면비드의 형성에 더 유리하다. 두께 2.7t의 연강 시편 2개를 갭 없는 I-그루브 맞대기 이음에서 Ǿ1.2 연강 솔리드 와이어를 사용하여 GMAW용접을 실시하였고, 용접전류, 용접속도, 경사상진 각, 위빙 폭, 위빙 주파수를 변경하여 각 조건에 대한 이면비드를 관찰하였다. 그 결과 경사상진 각 $25^{\circ}$, 전류 200A, 위빙폭 3mm, 위빙주파수 3Hz의 조건에서 안정적인 이면비드를 얻을 수 있었다. 또한, 현장에서 Fit-up중 발생할 수 있는 루트갭의 문제에 대하여 루트갭 1.2mm의 I-그루브 맞대기 용접에서 경사상진 각, 위빙 폭, 위빙 주파수는 갭 없이 실시한 실험에서 얻어진 가장 안정적인 결과를 사용하였고, 용접 전류, 용접 속도를 변경하여 이면비드를 관찰하였다, 그 결과 갭이 없을 때보다 약 80A 낮은 전류 조건인 120A에서 안정적인 이면비드를 얻을 수 있었다. 앞선 실험들을 기초로 하여 U-그루브 맞대기 용접을 실시 하였고, I-그루브 맞대기 용접에서 사용한 조건들과 유사한 용접 전류, 용접 속도에서 안정적인 이면비드를 얻을 수 있었다.

  • PDF

Fatigue Characteristics of PLZT(x/30/70) Thin Films with Various La Concentrations (La 농도에 따른 PLZT(x/30/70) 박막의 피로 특성에 관한 연구)

  • Kang, Seong-Jun;Chung, Yeun-Gun;Joung, Yang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1066-1072
    • /
    • 2005
  • The effects of La concentration in PLZT (z/30/70) thin film prepared by sol-gel method are investigated for the NVFRAM application. As the La concentration increases, the dielectric constants at 10 kHz increase from 450 to 600, while the loss tangent and the leakage current density at 100 kV/cm decrease from 0.075 to 0.025 and from $5.83{\times}10^{-7}\;to\;1.38{\times}10^{-7}\;A/cm^2,$ respectively. In the results of hysteresis loops measured at 175 kV/cm, the remanent polarization and the coercive field decrease from 20.8 to $10.5{\mu}C/cm^2$ and from 54.48 to 32.12 kV/cm, respectively, with the increase of La concentration from 0 to $10mol\%.$ After applying for $10^9$ cycles of square pulses with ${\pm}5V$ height, the remanent polarization of the PLZT (10/30/70) thin film decreases $40\%$ from the initial state, while that of the PLZT (10/30/70) thin film decreases $64\%.$.

Three-Dimensional Magnetic Resonant Coil System with Double Transmitter Coil for Enhancement of Wireless Charging Efficiency and Charging Flexibility (모바일 무선충전 효율 및 충전 자유도 개선을 위한 3차원 이중 송신 코일시스템)

  • Gwon, Gi-Jong;Kwon, Youngsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.9-16
    • /
    • 2020
  • Wireless charging has been considered an essential part of recent mobile devices. Moreover, various wireless charging systems have emerged through many studies. Among the systems, in the 2D flat coil system, the transmitter coil and receiver coil are arranged horizontally as close as possible to improve the charging efficiency. Nowadays, the 3D coil system has been proposed by adding some slope to flat 2D coils to reduce the volume. On the other hand, the 3D coil system has a lower charging efficiency than the 2D system that decreases rapidly with increasing distance. This paper proposes a new system that improves the low efficiency and charging freedom, which are the drawbacks of the existing 3D systems. The proposed system was designed in three-dimensions, and another transmitter coil was added to the transmitter coil to improve the transmission efficiency and flexibility. The measurement showed that the charging efficiency of the proposed system was 40.10% when the distance between coils was 8 mm, which is 20.5 % improvement over the existing one. The proposed method can be applied when new wireless charging systems are designed and improve charging efficiency can be improved.

Acoustic Target Strength of the Pelagic Fish in the Southern Waters of Korea I. In situ Measurement of Target Strength of Anchovy (Engraulis japonica) (한국 남해안 부어류의 음향반사강도에 관한 연구 I. 멸치 (Engraulis japonica)의 in situ 반사강도 측정)

  • YOON Gab Dong;KIM Zang Geun;CHOI Young Min
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.1
    • /
    • pp.107-114
    • /
    • 1996
  • The in situ target strength for the anchovy (Engraulis japonica) were measured by the split beam echo sounder system at 38 kHz. This study allowed us to detect the single echos from anchovy shoals which were dispersed during trawling operation in day time. The results of our study were as fellows: We found that the anchouy occupied about $95\%$ of the total catch from the detected shoals from which target strength data were collected. Length distribution of anchovy showed a mode and ranged from 13.6 to 15.4cm with a mean of 14.4cm and a standard deviation of 0.45cm, and weight distribution showed a mode and ranged from 16 to 28 g witha mean of 21.9 g and a standard deviation of 2.7 g. The target strength distribution of anchovy ranged from -40.7 dB to -69.2 dB in the water layer of ,$10\~30\;m$ -42.19 to -67.7 dB in the $30\~50\;m$ and -42.2 to -67.7 dB in $10\~50\;m$, showing 2 modes in each layer, respectively. Overall mean target strengths were -49.7 dB/fish and -33.1 dB/kg, averaged by area backscattering cross section $(\sigma)$, and the confidence interval for target strength was less than 1 dB. With the mean total length and the mean target strength, we drived the target strength-length relationship as $TS(\sigma)=20\;Log\;L-72.9$.

  • PDF

Respiratory Sinus Arrhythmia: Methods of Measurement and Interpretations of Tonic and Dynamic Vagal Cardiac Drive Index in Psychophysiology of Emotions

  • Estate M.Sokhadze;Lee, Jong-Mi;Park, Mi-Kyung;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.81-87
    • /
    • 2000
  • Beat-to-beat changes in heart period (heart period variability, HPV) are mediated by fluctuations in autonomic activity. Spectral analysis is used to quantify such fluctuations in the range of 0.15-0.40 Hz (high frequency, HF), which are influenced primarily by parasympathetic factors. These fluctuations are often referred to as RSA (respiratory sinus arrhythmia), the physiological phenomenon extracted by spectral analysis and other methods including histograms of heart rate ( HR), deviations of HR etc. Respiratory sinus arrhythmia indexing with peak-to-valley method suggested by Grossman et at., (1981) yields a simple range statistic and is quantified on breath-by-breath basis, thus being quite sensitive and less dependent on recording time as compared to spectral analysis. It is strongly recommended to use at least 1 min epoch to asses HF component of HPV and at least 2 min fer low frequency (LF) of HPV and even 5 min far valid clinical assessment. Peak-to-valley statistic is limited to RSA index only, but has its pragmatic advantages. Most important is possibility of its application far relatively small epoch analysis. We used short periods (20,30, 40 sec only) and off-line analysis of RSA using ECG and respiration curve this method of assessment and proved that this method is more practically effective. The RSA index was not so far dependent on respiration pattern differences and reflected actual vagal control of HR and were accompanied by low HR under some high stress conditions and in an aversive affective visual stimulation experiments. Another factor that might modulate cardiac chronotropic response is the interaction of sympathetic and parasympathetic inputs on sino-atrial (SA) node level, because responses to vagal influences are known to be proportional to ongoing sympathetic activity, that is so called accentuated antagonism. Since sympathetic outflow (increment of influences on SA) under negative emotions or stress was high in almost all physiological responses, vagal effects on HR could be therefore potentiated, leading to masking of output cardiac response seen in HPV, In the case of moderate sympathetic activation, on the other hand, autonomic interactions in cardiac control appear to be minimal. Thus RSA index appears to be an effective alternative method to assess and measure spectral HPV.

  • PDF

Anti-wrinkle Activity of Low Molecular Weight Peptides Derived from the Collagen Isolated from Asterias amurensis (불가사리(Asterias amurensis) 콜라겐 유래 저분자 펩타이드의 피부주름 억제활성)

  • Kwon, Min-Chul;Kim, Cheol-Hee;Kim, Hyo-Sung;Syed, Abdul Qadir;Hwang, Bo-Yong;Lee, Hyeon-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.625-629
    • /
    • 2007
  • This study was carried out to investigate the anti-wrinkle effects of peptides derived from collagens isolated from Asterias amurensis, which was collected in the East Sea. The molecular weights of the peptides were between 10-50 kDa, as determined through sephadek G-75 gel. The cytotoxicities against CCD-986sk cells and HEL-299 cells were measured using the MTT assay. The cytotoxicity of all the fractions(F1: Fraction No. 4-13, 116 kDa; F2: Fraction No. 25-30, 100 kDa; F3: Fraction No. 45-55, 58 kDa; F4: Fraction No. 59-63, 43 kDa; F5: Fraction No. 79-90, 24 kDa) was less than 25%, by the addition of 1.0 mg/mL. These peptides did not show any adverse effects on human skin cells. In the presence of F1 at 1.0 mg/mL, matrix metalloproteinase-1 (MMP-1) expression of UVA-induced human normal fibroblasts was reduced to 34.8%. Overall, the results seem to suggest that peptides of approximately 20 kDa have superior anti-wrinkle effects.

Distribution and characteristics of Quaternary faults in the coastal area of the southeastern Korean Peninsula: Results from a marine seismic survey (해양 탄성파 탐사 결과로 본 한반도 남동부연안 4기 단층의 분포와 특성)

  • Kim Han-Joon;Jou Hyeong-Tae;Hong Jong-Kuk;Park Gun-Tae;Nam Sang-Heon;Cho Hyun-Moo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.46-66
    • /
    • 2002
  • High-resolution multichannel seismic data were collected in the coastal area near the Gori nuclear power plant to investigate Quaternary fault pattern and timing. A 12 channel streamer, a sparker, and a portable recorder were used for data acquisition. Because the group interval of the streamer was 6.25 m and the sparker can generate acoustic waves with the frequency content of up to 500 Hz, the data show a significant improvement both in horizontal and vertical resolution. The area surveyed is covered with 30-40 m thick Holocene sediments that constitute the mud belt along the southeastern coast of Korea. The survey area is characterized by the well discriminated Pleistocene and Holocene boundary and shallow gas-charged zones. A number of Quaternary faults were found in the sediment column, that are nearly vertical and extend north-south. The Quaternary faults, arranged at a spacing of a few hundred meters, suggest that they were formed in response to compression, although some of them reveal extensional characteristics. Locally, faults disrupt Incised-channel fills that are interpreted to have formed in the early stage of transgression after the beginning of the Holocene. Seismic sections suggest that shallow gas in the mud belt sediments made its way upward through the fractured fault planes. The tectonism responsible for the opening of the East Sea has not persisted since the late Miocene, but vigorous Quaternary faulting activity in the vicinity of the southeastern Korean Peninsula indicates that tectonic stability has yet to be achieved in this region underlain by the hotter than normal mantle.

  • PDF

Effects of Anticancer Drug Delivery based on Microbubble and Microbubble-Nanoparticle Complex using Low-Intensity Focused Ultrasound in Breast Cancer Animal Model (유방암 동물모델에서의 저강도 집속초음파를 이용한 마이크로버블 및 마이크로버블-나노물질 복합체 기반 항암제 전달 효율 검증)

  • Baek, Hee Gyu;Ha, Shin-Woo;Huh, Hyungkyu;Jung, Byeongjin;Han, Mun;Moon, Hyungwon;Kim, Sangkyun;Lee, Hak Jong;Park, Juyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.39-47
    • /
    • 2019
  • Ultrasound sonication along with microbubble (MB) could enhance drug delivery to promote the absorption of anticancer drugs into cancers in a noninvasive and targeted manners. In this study, we verify the acute drug delivery enhancement (within an hour) of two representative focused ultrasound driven drug delivery enhancement methods (MB and Doxorubicin-coated Nanoparticle complex (MB-NP) based). Experiments were conducted using in vivo mouse model with MDA-MB-231 breast cancer cell line. Ultrasound generated by single-element 1 MHz focused ultrasound transducer was delivered in pulsed sonication consisted of 0.125 msec bursts at a pulse repetition frequency of 2 Hz for 20 seconds without a significant increase in local temperature (less than $0.1^{\circ}C$) or hemorrhage. Doxorubicin concentrations in tumors were improved by 1.97 times in the case of MB-NP, and 1.98 times by using Doxorubicin and MB separately. These results indicate anticancer drug delivery based on MB and MB-NP can significantly improve the effect of anticancer drugs delivered to tumors in a short time period by using low-intensity focused ultrasound.

High-Frequency Bottom Loss Measured at Near-Normal Incidence Grazing Angle in Jinhae Bay (진해만에서 측정된 높은 수평입사각에서의 고주파 해저면 반사손실)

  • La, Hyoung-Sul;Park, Chi-Hyung;Cho, Sung-Ho;Choi, Jee-Woong;Na, Jung-Yul;Yoon, Kwan-Seob;Park, Kyung-ju;Park, Joung-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.223-228
    • /
    • 2010
  • High-frequency bottom loss measurements for grazing angle of $82^{\circ}$ in frequency range 17-40 kHz were made in Jinhae bay in the southern part of Korea. Observations of bottom loss showed the strong variation as a function of frequency, which were compared to the predicted values using two-layered sediment reflection model. The geoacoustic parameters including sound speed, density and attenuation coefficient for the second sediment layer were predicted from the empirical relations with the mean grain size obtained from sediment core analysis. The geoacoustic parameters for the surficial sediment layer were inverted using Monte Carlo inversion algorithm. A sensitivity study for the geoacoustic parameters showed that the thickness of surficial sediment layer was most sensitive to the variation of the bottom loss.