• 제목/요약/키워드: 400kN suspension insulator

검색결과 4건 처리시간 0.018초

FEM을 이용한 400kN 현수애자의 절연특성 해석 (Analysis of Dielectric Characteristics of 400kN Suspension Insulator Using FEM)

  • 최재구;김익수;문인욱;서형권
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.80-84
    • /
    • 2002
  • This paper presents some of the results of current research on 400kN Suspension Insulator Design. In this paper, authors carried out 2-dimensional field calculation in order to analyse dielectric characteristics of the insulator unit and 3-dimensional field calculation in order to analyse dielectric characteristics of the insulator strings. And the results of puncture tests of insulators were compared with the required field intensity of the insulator As results, it was found that electric field on the insulator unit is severest between two triple junctions, dielectric characteristics of insulator strings are much influenced by the surrounding configuration and the manufactured insulators have good results of puncture tests.

765 kV용 400 kN 현수애자 개발 (Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines)

  • 최인혁;최장현;이동일;최연규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.

400kN 송전용 현수애자의 특성연구 (A Study on Characteristics of Suspension Insulator for 400kN Transmission Lines)

  • 최인혁;신태우;최연규;민병욱;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1434-1436
    • /
    • 2002
  • The 400KN suspended insulator was fabricated with feldspar, quartz, clay and $Al_2O_3$ wt% for extra high voltage. These materials were grinded with ball milling for 25 hours after mixing them. The grinded materials were sintered at $1300^{\circ}C$ for 50 minutes in the tunnel kiln after mading with jiggering method. The sintered density of specimen was reached at 97% in comparison with that of theory. The specimen had the characteristic of temperature rise with the increase of electrical losses. Also, the flexural strength and the fracture toughness of sintered parts respectively were 1658 kg/$cm^2$ and 2.3 $MPa{\cdot}m^{1/2}$.

  • PDF

400kN 송전용 자기애자의 재질에 따른 특성 연구 (A study on properties of 400kN porcelain suspension insulator for transmission line by analyzing of raw materials)

  • 최인혁;최장현;정윤환;이동일;정길조;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1637-1639
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of the home production porcelain insulators by change of the alumina addition amount, 36000lbs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 [wt.%] alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 [MPa $M^{1/2}$], respectively. However, 12 [wt.%] alumina was contained in case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3 [MPa $M^{1/2}$], respectively. Amount of alumina was contained most by 17 [wt.%] in case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared excellently by 96% and 1.7 [MPa $m^{1/2}$], respectively.