• Title/Summary/Keyword: 4-bedroom

Search Result 156, Processing Time 0.027 seconds

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

A Study on the Living Environment of the Residents of the Dementia Care Village

  • Moon, Ok Kon;Yeum, Dong Moon;Choi, Wan Suk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.4
    • /
    • pp.1636-1641
    • /
    • 2018
  • The purpose of this study was to investigate the relationship between the needs for environmental improvement and dementia patients' activity of daily living (ADL) and behavior and psychological symptoms of dementia (BPSD) in dementia patients living in urban type dementia care villages. The subjects of this study were 70 households with cognitive impairment and dementia among residents of dementia care village in Gunsan City. The survey was conducted with the permission of their family. Frequency analysis and descriptive statistical analysis were performed on the main variables to analyze the characteristics of the subjects. Bivariate correlation analysis was performed to verify the relationship between the two variables. According to the analysis results, the order of environment improvement was in the order of entrance (51.4%), toilet and stairs (48.6%), kitchen (11.4%), bedroom and laundry room (10.0%). In the relationship between the variables, The ADL was correlated with age (r=.315, p <.01), BPSD (r=.322, p<.01) and living environment inconvenience (r=.640, p<.01) while, living environment inconvenience correlated with environment improvement need (r=.669, p<.01). This study suggests that improvement of the residential environment of dwellers in dementia care villages, especially the stairway and entrance hall is necessary.

A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping (취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구)

  • Kim, Se-Hwan;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

An Analysis on the Characteristic of the Master-Zone Planning in the Apartment Building (공동주택의 부부 전용공간 분석)

  • Park, So-Yun;Lee, Kyung-A;Lee, Hyun-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.189-192
    • /
    • 2005
  • The purpose of this study is to analyze space composition and size of the Master Zone in the apartment unit plan. For this, we analyzed 435 samples by searching web-sites of the 5 main construction companies. The major results of this study are as follows. 1) Master Zone is organized 4 spaces such as main room, bathroom and make-up & dress room. Six types of Master Zone are classified with the composition of 4 spaces. 2) The size of the Master Zone is increased in proportion to the square meter. But the range of the ratio is small range of fluctuation as 20%${\sim}$30%. 3)The size and ratio of the each spaces of the Master Zone are analyzed. The size of bedroom is increased but the ratio is decreased. The size of bathroom is increased but the ratio is regular as 4%${\sim}$5%. The size of make-up and dressing room is generally increased but the range of the size and ratio is the most extensive. Through this analysis and research, this study would be provied the basic data for actual housing planning and to contribute to future trends of apartment houses.

  • PDF

Low Back Pain Incidence by the Sexual Style of the Middle-age Coupled (중년층 부부생활 형태가 요통발생에 미치는 영향)

  • Park, Ji-Whan;Shim, Choong-Seob
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.4 no.1
    • /
    • pp.59-69
    • /
    • 1998
  • The purpose of this research is to be grasp the relation between lumbago incidence rate and research hypothesis in the effects of sex life of the middle-aged couples in Taejon area upon lumbago. This writer had questionaired the 400 middle-aged couples in Taejon city - Jung-gu, Seo-gu, Dong-gu, Yuseong-gu, and Taedeok-gu - from June 1, to June 30, 1998. Of them, total 209 question papers were drawn back; male 102, female 107. Analysis of the data is as follows; 1. 145(69.37%) subjects of total 209 had low back pain experience after their sexual lives. 2. In the number of sexual times a week, low back pain incidence were the most rate in 1-2 times as 41.55%, each other had a statistically significant relation (P<0.01). 3. In age and lumbago incidence rate, the 30s was 37.75% and each other had a significant relation (P<0.05). 4. In weight and lumbago incidence rate, the level of 50kg~60kg was highest and each other didn't have a significant relation (P>0.05). 5. In the mean sexual time, the period of 11~20 minutes was 29.47% and each other had a significant relation (P>0.01). 6. In a day time of sexual life and lumbago incidence rate, midnight was the highest rate(36.23%) and each other didn't have a significant relation (P>0.05). 7. In the lumbago incidence rate according to bedroom structure of sexual life, a bed was 38.17% and each other had a significant relation (P>0.05). 8. In the lumbago incidence rate according to sexual posture, a normal position showed the highest rate(46.12%) and each other didn't have a significant relation (P>0.05). According to the results of our research, lumbago has relation to the number of sex life a week, age, the mean time of sexual life, and bedroom structure of sexual life. So it is thought that it is necessary that middle-aged couples periodically study the educational programs to make an prevention education for low back pain the key points.

  • PDF

A Study on the Improving Speech Intelligibility of Emergency Broadcast Equipment in the Apartments (공동주택 내 비상방송설비의 음성명료도 실태 분석 및 재실자 인지성 개선방안 연구)

  • Oh, So-Young;Cho, Hyun-Min;Lee, Young-Ju;Lee, Min-Joo;Yoon, Myung-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.60-68
    • /
    • 2018
  • Due to the complicated plan structure of the apartment units and the improved room-to-room sound insulation performance, it is difficult to communicate and recognize the fire situation by emergency broadcast equipment. In this study, speech intelligibility was measured and analyzed for three types of apartment unit by emergency broadcast equipment on various measurement points. Simulations were also conducted to improve the speech intelligibility. As a result of field measurements 72, 84, and 101 Type were not satisfied with NFSC standard of 90 dBA at the point of 1 m distance from source. In addition, it was evaluated that 75 dBA and CIS 0.7 of NFPA standard was not satisfied at all measurement points except for the 72 Type at living room point with door opened condition. Based on the door opened condition of the bedroom, it satisfied the NFPA of 75 dBA and CIS 0.7 in each bedroom when more than 90 dBA was satisfied at the 1 m separation point provided in NFSC standard.

The Real Scale Fire Test for Fire Safety in Apartment Housing (실물화재실험을 통한 공동주택의 화재안전성 연구)

  • Yoo, Yong-Ho;Kweon, Oh-Sang;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.57-65
    • /
    • 2009
  • This study was intended to conduct a Real-scale fire test to predict the fire behavior by unit space at the apartment building where a huge casualties and injuries are likely. After setting the inflammables inside the house, the test aimed to identify the fire characteristics to each unit item was carried out. The house was divided into 4 unit space such as kitchen, living room, bedroom and a study for a real scale fire test. As a result, bedroom reached to flashover state in 5minutes after setting the fire, indicating a rapid fire growth such as 7433.3kW of maximum thermal emissivity, 578.6ppm of carbon monoxide, 1.25ppm of carbon dioxide and $1,350^{\circ}C$ of maximum indoor temperature. Particularly, the fire growth was made up to critical temperature which might cause a severe damage to the people within 3minutes, if the fire were not extinguished at inflammable space at the early stage of fire, which stressed the need of early response. The result of a real scale fire test could be compared with the outcome of expanded simulation test and used in predicting the fire spread at the space for different use.

Users' Satisfaction on the Dormitory of High School in Jeonju City (고등학교 기숙사 주거시설에 대한 사용자 만족도)

  • An, Jin-Sook;Choi, Byung-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.202-207
    • /
    • 2006
  • This study was to find out users' satisfaction on the dormitory high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows : 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 3.23, and the space utility and the space size of functional factor and the heating/ventilation of technical factor were highly effected their satisfaction.

  • PDF

A Study on the proportion of functional Areas in the ward of General Hospitals (종합병원의 병동부 기능공간 구성비율에 관한 연구)

  • Kwon, Soonjung;Joo, Sohyeon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.4
    • /
    • pp.49-55
    • /
    • 2011
  • This study proposes proportions of functional areas in the ward of general hospitals, which are derived from 5 big university hospitals in order to establish the ward area standard for hospital design. The results of this paper are as follows. First, functional areas of hospital ward are composed of bedroom area, nursing area, training area, service area, and common area. Of course common area can be divided into first common area and secondary common area. The first common area(inter departmental common area) includes lobbies, elevator lobbies, corridors, restroom, and mechanical shafts. The secondary common area means the common area within special department such as ward or radiology department. Second, a standard method of calculating ward areas has been proposed: the standard is based on the center line of the wall between functional areas. Third, the proportions of 6 functional areas in ward are suggested.

Visual Search Model based on Saliency and Scene-Context in Real-World Images (실제 이미지에서 현저성과 맥락 정보의 영향을 고려한 시각 탐색 모델)

  • Choi, Yoonhyung;Oh, Hyungseok;Myung, Rohae
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.4
    • /
    • pp.389-395
    • /
    • 2015
  • According to much research on cognitive science, the impact of the scene-context on human visual search in real-world images could be as important as the saliency. Therefore, this study proposed a method of Adaptive Control of Thought-Rational (ACT-R) modeling of visual search in real-world images, based on saliency and scene-context. The modeling method was developed by using the utility system of ACT-R to describe influences of saliency and scene-context in real-world images. Then, the validation of the model was performed, by comparing the data of the model and eye-tracking data from experiments in simple task in which subjects search some targets in indoor bedroom images. Results show that model data was quite well fit with eye-tracking data. In conclusion, the method of modeling human visual search proposed in this study should be used, in order to provide an accurate model of human performance in visual search tasks in real-world images.