• Title/Summary/Keyword: 4-ball test

Search Result 293, Processing Time 0.027 seconds

Effects of Low Intensity Exercise Program with Telephone Coaching on Physical Fitness (전화코칭을 동반한 저강도 운동 프로그램이 방문건강관리 노인의 체력에 미치는 효과)

  • Kim, Sang-Hee;Lee, Ji-Hyun;Koh, Kwang-Wook;Ha, Hyun-Bo
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.15 no.4
    • /
    • pp.457-466
    • /
    • 2008
  • Purpose: The purpose of this study was to determine the effects of low intensity exercise program with telephone coaching on the physical fitness of elderly people who are receiving home visiting nursing care. Method: This study was conducted using a non-equivalent control group pretest-posttest design. The participants were 61 elders. Elders (34) in the experimental group performed low intensity exercise and of these 16 received telephone coaching. The low intensity exercise program consisted of stretching, muscle strengthening with an elastic band, massage, and ball exercise, five days a week, for sixteen weeks. Data were collected from July 2007 to December 2007. $x^2$-test, ANCOVA with SPSS WIN 11.0 program were used to analyse the data. Results: There were statistical differences in the right grasping power in the right hand (p=0.021), Raising behind of right arm (p=0.006), Raising behind of left arm (p=0.007). Conclusion: These results indicate, that a low intensity exercise program with telephone coaching can help improve physical fitness in elders receiving served home visiting nursing care.

  • PDF

An Experimental Study on Damage Mechanism of Glass Resulting Frojm Particle Impact (입자충격에 의한 유리의 손상기구에 관한 실험적 연구)

  • Seo, Chang-Min;Sin, Hyeong-Seop;Hwang, Byeong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.6
    • /
    • pp.1903-1912
    • /
    • 1996
  • A quantitative study of impact damage of a soda-lime glass was carried out. An initiation and a propagation of cracks by the impact of two inds of steel ball was investigated. The fron, side and rear view of cracks were observed by a stereo-microscope. And the lowering of the benidng strength due to the impact of steel balls was examined through the 4-point bending test. A transparent glass is very helpful to understand and analyze the impact damage behavior of another brittle matereial. A deagdram about crack patterns according to the threshold impact velocity was sketched. A ring crack and a cone crack were formed at the low impact velocity. And as the impact velocity was higher, initial lateral crack was generated on the slanting surface of cone crack, and radial cracks were generated from the outermost ring crack. When the impact velocity of steel balls exceed a critical velocity, the contact site of specimens were crushed. According to the propagation of a cone crack, a rapid strength degradation occurred. In the specimen having crushed region, a bending strength was converged to a constant value instead of strength degradation.

Tribological Behavior Analysis of CrMoN Coating by XPS (XPS 분석을 통한 CrMoN 코팅의 마찰마모 거동 연구)

  • Yang, Young-Hwan;Lyo, In-Woong;Park, Sang-Jin;Lim, Dea-soon;Oh, Yoon-Suk
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.8
    • /
    • pp.549-556
    • /
    • 2012
  • The tribological behavior of CrMoN films with respect to surface chemistry was investigated by using X-ray photoelectron spectroscopy (XPS). All of the films were prepared from a hybrid PVD system consisting of DC unbalanced magnetron (UBM) sputtering and arc ion plating (AIP) sources. The tribological property of the films was evaluated by a friction coefficient using a Ball-on-disk type tribometer. The chemistry of wear track was analyzed by energy dispersive spectroscopy (EDS) and XPS. The friction coefficient was measured to be 0.4 for the CrMoN film, which is lower than that of a monolithic CrN film. EDS and XPS results imply the formation of an oxide layer on the coating surface, which was identified as molybdenum oxide phases, known to be a solid lubricant during the wear test.

EFFECT OF $CEO_2$ ADDITION IN GLASS COMPOSITION ON THE STRENGTH OF ALUMINA-GLASS COMPOSITES (알루미나-유리 복합체용 글래스의 조성에서 $CeO_2$의 함량변화가 강도에 미치는 영향)

  • Lee, Hwa-Jin;Song, Kwang-Yeob;Kang, Jeong-Kil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.595-605
    • /
    • 2000
  • Dental ceramics have good aesthetics, biocompatibility, low thermal conductivity, abrasion resistance, and color stability. However poor resistance to fracture and shrinkage during firing process have been limiting factors in their use, particularly in multiunit ceramic restorations. A new method for making all-ceramic crowns that have high strength and low processing shrinkage has been developed and is referred to as the Vita In-Ceram method. This study was performed to investigate the effect of $CeO_2$ addition in borosilicate glasses on the strength of alumina-glass composites. Porous alumina compacts were prepared by slip casting and sintered at $1,100^{\circ}C$ for 2 hours. Dense composites were made by infiltration of molten glass into partially sintered alumina at $1,140^{\circ}C$ for 4 hours. Specimens were polished sequentially from #800 to #2000 diamond disk. and the final surface finishing on the tensile side was received an additional polishing sequence through $1{\mu}m$ diamond paste. Biaxial flexure test was conducted by using ball-on-three-ball method at a crosshead speed of 0.5mm/min. To examine the microstructural aspect of crack propagation in the alumina-glass composites, Vickers-produced indentation crack was made on the tensile surface at a load of 98.0 N and dwell time of 15 sec, and the radial crack patterns were examined by an optical microscope and a scanning electron microscope. The results obtained were summarized as follows; 1. The porosity rates of partially sintered alumina decreased with the rising of firing temperature. 2. The maximum biaxial flexure strength of 423.5MPa in alumina-glass composites was obtained with an addition of 3 mol% $CeO_2$ in glass composition and strength values showed the aspect of decrease with the increase of $CeO_2$ content. 3 The biaxial flexure strength values of alumina-glass composites were decreased with rising the firing temperature. 4. Observation of the fracture surfaces of alumina-glass composites indicated that the enhancement of strength in alumina-glass composites was due to the frictional or geometrical inter-locking of rough fracture surfaces and ligamentary bridging by intact islands of materials left behind the fracture front.

  • PDF

Hard TiN Coating by Magnetron-ICP P $I^3$D

  • Nikiforov, S.A.;Kim, G.H.;Rim, G.H.;Urm, K.W.;Lee, S.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.414-420
    • /
    • 2001
  • A 30-kV plasma immersion ion implantation setup (P $I^3$) has been equipped with a self-developed 6'-magnetron to perform hard coatings with enhanced adhesion by P $I^3$D(P $I^3$ assisted deposition) process. Using ICP source with immersed Ti antenna and reactive magnetron sputtering of Ti target in $N_2$/Ar ambient gas mixture, the TiN films were prepared on Si substrates at different pulse bias and ion-to-atom arrival ratio ( $J_{i}$ $J_{Me}$ ). Prior to TiN film formation the nitrogen implantation was performed followed by deposition of Ti buffer layer under A $r^{+}$ irradiation. Films grown at $J_{i}$ $J_{Me}$ =0.003 and $V_{pulse}$=-20kV showed columnar grain morphology and (200) preferred orientation while those prepared at $J_{i}$ $J_{Me}$ =0.08 and $V_{pulse}$=-5 kV had dense and eqiaxed structure with (111) and (220) main peaks. X-ray diffraction patterns revealed some amount of $Ti_{x}$ $N_{y}$ in the films. The maximum microhardness of $H_{v}$ =35 GN/ $M^2$ was at the pulse bias of -5 kV. The P $I^3$D technique was applied to enhance wear properties of commercial tools of HSS (SKH51) and WC-Co alloy (P30). The specimens were 25-kV PII nitrogen implanted to the dose 4.10$^{17}$ c $m^{-2}$ and then coated with 4-$\mu\textrm{m}$ TiN film on $Ti_{x}$ $N_{y}$ buffer layer. Wear resistance was compared by measuring weight loss under sliding test (6-mm $Al_2$ $O_3$ counter ball, 500-gf applied load). After 30000 cycles at 500 rpm the untreated P30 specimen lost 3.10$^{-4}$ g, and HSS specimens lost 9.10$^{-4}$ g after 40000 cycles while quite zero losses were demonstrated by TiN coated specimens.s.

  • PDF

The Study of Mechanical Simulation for Human Respiratory System (인체 호흡 모사를 위한 기계적 장치 연구)

  • Chi, S.H.;Lee, M.K.;Lee, T.S.;Choi, Y.S.;Oh, S.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.323-328
    • /
    • 2008
  • A patient with respiratory disorders such as a sleep apnea is increasing as the obese patient increase on the modern society. Positive Airway Pressure (PAP) devices are used in curing patient with respiratory disorders and turn out to be efficacious for patients of 75%. However, these devices are required for evaluating their performance to improve their performance by the mechanical breathing simulator. Recently, the mechanical breathing simulator was studied by the real time feedback control. However, the mechanical breathing simulator by an open loop control was specially required in order to analyze the effect of flow rate and pressure after operating the breathing auxiliary devices. Therefore the aims of this study were to make the mechanical breathing simulator by a piston motion and a valve function from the characteristic test of valve and motor, and to duplicate the flow rate and pressure profiles of some breathing patterns: normal and three disorder patterns. The mechanical simulator is composed cylinder, valve, ball screw and the motor. Also, the characteristic test of the motor and the valve were accomplished in order to define the relationship between the characteristics of simulator and the breathing profiles. Then, the flow rate and pressure profile of human breathing patterns were duplicated by the control of motor and valve. The result showed that the simulator reasonably duplicated the characteristics of human patterns: normal, obstructive sleep apnea (OSA), mild hypopnea with snore and mouth expiration patterns. However, we need to improve this simulator in detail and to validate this method for other patterns.

Friction and Wear Characteristics of Plasma Coated Surface of Casting Aluminum Alloy (플라즈마 코팅한 주조용 알루미늄합금의 마찰 및 마멸특성)

  • Chae, Young-Hun;Ren, Jing-Ri;Park, Jun-Mock;Kim, Seock-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.791-799
    • /
    • 1997
  • The wear characteristics and wear mechanisms of plasma sprayed Al/sub 2/ O/sub 3/-40%TiO/sub 2/ and Cr/sub 2/O/sub 3/ deposited on casting aluminum alloy(AC4C) were investigated. Specimens were processed for various coating thicknesses. Ball on disk type wear tester was used for wear test. The scratch test on plasma sprayed coating surface showed that critical load to break the coating layer was greater than 40 N. The critical load increase with the increase of coating thickness of specimens. The friction coefficient of Cr/sub 2/O/sub 3/ coating layer was less than that of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer. The wear resistance of Cr/sub 2/O/sub 3/ coating layer was greater than that of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer. Microscopic observation of worn surfaces was made by SEM. SEM observation showed that the main mechanism of wear for Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer was abrasive wear under 50 N. For the case of Al/sub 2/O/sub 3/-40%TiO/sub 2/ coating layer, as the surface cracks perpendicular to sliding direction propagated, the wear debris was generated in wear track. However, the main mechanism of wear for Cr/sub 2/O/sub 3/ coating layer was brittle fracture under 150 N.

Development of an Exercise Program for Postmastectomy Patient (유방절제술 환자를 위한 운동프로그램 개발)

  • Lee, Ja-Hyung;Cho, Jae-Kyung;Oh, Ji-Na;Kim, Sung-Hee;Ahn, Hye-Im
    • Women's Health Nursing
    • /
    • v.10 no.4
    • /
    • pp.301-310
    • /
    • 2004
  • Purpose: The purpose of this study was to develop an exercise program for postmastectomy patients. Method: This study was conducted from October, 2003 to June, 2004. The exercise program was developed based on literature review and needs assessment using focus group interviews. The subjects for the focus group interview consisted of 11 patients, 13 recovering patients, and 20 nurses from 3 hospitals. Development of the program was proceeded with analysusm design and development steps. Result: The results of the needs assessment using the focus group interview showed that the exercise program was imperative for postmastectomy patients. Based on the results, a home video tape containing 3 steps, was developed. Each step includes warming-up, stretching, the main exercise, and cool-down. Steps 2 and 3 include exercises with an elastic band, and an elastic ball. The program was modified after conducting a pre-test. A self-checklist including shoulder mobility, hand strength, arm volume and subjective comments on how they feel will be used before and after the exercise program. Conclusion: The exercise program will improve breast cancer patients' quality of life and their physical well-being. Further studies are recommended to test the effectiveness of the exercise program.

  • PDF

Effects of Physical Activity and Melatonin in a Rat Model of Depression Induced by Chronic Stress (자유로운 신체운동과 멜라토닌이 우울장애 동물모델에 미치는 효과)

  • Seong, Ho Hyun;Jung, Sung Mo;Kim, Si Won;Kim, Youn Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose: Stress, depending on its intensity and duration, results in either adaptive or maladaptive physiological and psychological changes in humans. Also, it was found that stressful experiences increase the signs of behavioral despair in rodents. On the other hand, exercise and melatonin treatment is believed to have many beneficial effects on health. Thus, this study was designed to evaluate the anti-depressant effects of physical activity and melatonin against chronic stress-induced depression in rats. Methods: Adult male Sprague-Dawley(SD) rats(200-250g, 7 weeks of age) were subjected to depression induced by chronic stress. Chronic depression was induced with forced-swim stress (FSS) and repeated change of light-dark cycle for 4 weeks. In the last 2 weeks, some rats were confined in a cage enriched with a running wheel, seesaw and chewed a ball from 19:00 to 07:00 every day. Melatonin was injected intra-peritoneally (I.P), and the rats received intraperitoneal injections of melatonin (15 mg/kg). The Forced Swim Test (FST) was performed to evaluate the immobility behaviors of rats for a 5 min test. Results: It was found that, the immobility time in FST was significantly (p<.05) lower in physical exercise ($M=58.83{\pm}22.73$) and melatonin ($M=67.33{\pm}37.73$) than in depressive rats ($M=145.93{\pm}63.16$) without physical activity. Also, TPH positive cell in dorsal raphe was significantly (p<.05) higher in exercise ($M=457.38{\pm}103.21$) and melatonin ($M=425.38{\pm}111.56$) than in depressive rats ($M=258.25{\pm}89.13$). Conclusion: This study suggests that physical activity and melatonin produces antidepressant-like effect on stress-induced depression in rats. So, physical exercise and melatonin may be a good intervention in depression patients.

Nanocrystalline Diamond Coated SiC Balls in Tribometer (나노결정질 다이아몬드가 코팅된 SiC 마모시험기 볼)

  • Im, Jong Hwan;Kang, Chan Hyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.5
    • /
    • pp.263-268
    • /
    • 2014
  • Nanocrystalline diamond(NCD) coated SiC balls were applied in a ball-on-disk tribometer. After seeding in an ultrasonic bath containing nanometer diamond powders, $2.2{\mu}m$ thick NCD films were deposited on sintered 3 mm diameter SiC balls at $600^{\circ}C$ in a 2.45 GHz microwave plasma CVD system. Bare $ZrO_2$ and SiC balls were prepared for comparison as test balls. Tribology tests were performed in air with pairs of three different balls and mirror polished steel(SKH51) disk. The wear tracks on balls and disks were examined by optical microscope and alpha step profiler. Under the load of 3 N, the friction coefficients of steel against $ZrO_2$, SiC and NCD-coated balls were between 0.4 and 0.8. After a few thousands sliding laps, the friction coefficient of NCD-coated balls dropped from 0.45 to below 0.1 and maintained thereafter. Under a higher load of 10 N or 20 N with a long sliding distance of 2 km, $ZrO_2$ and SiC balls exhibited the similar friction coefficients as above. The friction coefficient of NCD-coated balls was less than 0.1 from the beginning and increased to above 0.1 steadily or with some fluctuations as sliding distance increased. NCD coating layers were found worn out after long duration and/or high load sliding test, which resulted in the friction coefficient higher than 0.1.