• Title/Summary/Keyword: 4 probe measurement

Search Result 310, Processing Time 0.032 seconds

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

"Leak Current" correction for critical current measurement of no-insulation HTS coil

  • Song, Jung-Bin;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.48-52
    • /
    • 2017
  • Discrepancy between a power supply current and an actual "spiral" coil current makes the conventional 4-probe measurement of a critical current ($I_c$) of a no-insulation (NI) high temperature superconductor (HTS) coil inaccurate and time-consuming. This paper presents a fast and accurate approach for $I_c$ measurement of NI HTS coils. With an NI HTS coil energized at a constant ramping rate, a complete analytic expression for the spiral coil current was obtained from a first-order partial differential equation that derived from an equivalent circuit model of the NI coil. From the analytic solution, both spiral coil current and radial leak current can be obtained simultaneously, which enables fast and accurate measurement of the NI coil $I_c$. To verify the proposed approach, an NI double-pancake (DP) coil, wound with GdBCO tapes of $6mm{\times}0.1mm$, was constructed and its $I_c$ was repeatedly measured with various ramping rates in a bath of liquid nitrogen at 77 K. The measured results agreed well with the calculated ones, which validates the proposed approach to measure $I_c$ of an NI HTS coil.

A Melon Fruit Grading Machine Using a Miniature VIS/NIR Spectrometer: 2. Design Factors for Optimal Interactance Measurement Setup

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Shin, Hwa-Sun;Yoo, Soo-Nam;Choi, Yong-Soo
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.177-183
    • /
    • 2012
  • Purpose: In near infrared spectroscopy, interactance configuration of a light source and a spectrometer probe can provide more information regarding fruit internal attributes, compared to reflectance and transmittance configuration. However, there is no through study on the parameters of interactance measurement setup. The objective of this study was to investigate the effect of the parameters on the estimation of soluble solids content (SSC) and firmness of muskmelons. Methods: Melon samples were taken from greenhouses at three different harvesting seasons. The prediction models were developed at three distances of 2, 5, and 8 cm between the light source and the spectrometer probe, three measurement points of 2, 3, and 6 evenly distributed on each sample, and different number of fruit samples for calibration models. The performance of the models was compared. Results: In the test at the three distances, the best results were found at a 5 cm distance. The coefficient of determination ($R_{cv}{^2}$) values of the cross-validation were 0.717 (standard error of prediction, SEP=$1.16^{\circ}Brix$) and 0.504 (SEP=4.31 N) for the estimation of SSC and firmness, respectively. The minimum measurement point required to fully represent the spectral characteristics of each fruit sample was 3. The highest $R_{cv}{^2}$ values were 0.736 (SEP=$0.87^{\circ}Brix$) and 0.644 (SEP=4.16 N) for the estimation of SSC and firmness, respectively. The performance of the models began to be saturated when 60 fruit samples were used for developing calibration models. The highest $R_{cv}{^2}$ of 0.713 (SEP=$0.88^{\circ}Brix$) and 0.750 (SEP=3.30 N) for the estimation of SSC and firmness, respectively, were achieved. Conclusions: The performance of the prediction models was quite different according to the condition of interactance measurement setup. In designing a fruit grading machine with interactance configuration, the parameters for interactance measurement setup should be chosen carefully.

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

Antibacterial property and characterization of CuSn thin films deposited by RF magnetron co-sputtering method

  • Gang, Yu-Jin;Park, Ju-Yeon;Kim, Dong-U;Kim, Hak-Jun;Gang, Yong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.360.2-360.2
    • /
    • 2016
  • CuSn thin films were fabricated by rf magnetron co-sputtering method on the Si(100) substrate for evaluation of the antibacterial effect. The co-sputtering process was performed with different rf powers and sputtering times to regulate the thickness of the films and relative atomic ratio of Cu to Sn. The physicochemical properties of the CuSn thin films were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), X-ray induced Auger electron spectroscopy (XAES), Optical microscope (OM), 4-point probe, and antibacterial test. An antibacterial test was conducted with Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) as changing contact times between CuSn fillms and bacteria suspension. We compared to the crystalline structures of films before sterilization and after sterilization by XRD measurement. The changes of oxidation states of Cu and Sn and the chemical environment of films before and after antibacterial test were investigated with high resolution XPS spectra in the regions of Cu 2p, Cu LMM, and Sn 3d. After antibacterial test, the morphology of the films was checked with an OM images. The electrical properties of the CuSn films such as surface resistance and conductivity were measured by using 4-point probe.

  • PDF

Principle Measurement Method of Metals Resistivity (금속 비저항의 정밀측정 방법)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Park, Young-Tae;Lee, Sang-Hwa;Ryu, Kwan-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2124-2125
    • /
    • 2011
  • 금속의 비저항 측정방법은 4단자 방법, van der Pauw 방법, Four-Point Probe(FPP) 방법, eddy current 방법 등이 있다. 이들의 측정방법은 다르지만 동일한 시료에 대해 평가한 비저항은 측정 불확도 범위 내에서 일치하여야 한다. 이에 따라 균질한 비자성 금속(STS 316)을 선정한 후 비저항을 평가한 결과 4단자와 van der Pauw 방법에 의한 비저항(도전율)은 각각 75.86 ${\mu}{\Omega}{\cdot}cm$(2.273 %IACS)과 75.84 ${\mu}{\Omega}{\cdot}cm$(2.273 %IACS)로서 거의 동일한 결과를 나타냈으며, Four Point Probe(FPP) 방법은 75.91 ${\mu}{\Omega}{\cdot}cm$(2.271 %IACS), eddy current 방법은 76.63 ${\mu}{\Omega}{\cdot}cm$(2.25 %IACS)으로 나타났다.

  • PDF

Correlation of Wall Vorticity and Streamwise Velocity Fluctuations in a Turbulent Boundary Layer (난류경계층에서 벽와도와 유동방향 속도섭동과의 상관관계)

  • Ryu, Sang-Jin;Kim, Seong-Uk;Yu, Jeong-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.523-532
    • /
    • 2001
  • A simultaneous measurement of wall vorticity and near-wall streamwise velocity fluctuations has been performed using a V-type wall vorticity probe and an I-type velocity probe to investigate the relation between them. Long-time averaged space-time correlations show that the wall vorticity is highly correlated with a turbulence structure which is tilted from the wall in the streamwise direction and that there is a streamwise vortex pair near the wall. It is shown that a structure correlated with the streamwise wall vorticity is smaller than and prior to a structure correlated with the spanwise wall vorticity. Tilting angles are obtained from the phase shift between the wall vorticity and streamwise velocity fluctuations. The tilting angle of the structure correlated with the streamwise wall vorticity is larger than that of the structure correlated with the spanwise wall vorticity. The convection velocity of the near-wall streamwise velocity fluctuations obtained from the space-time correlation is in good agreement with previous results.

Prototype Milli Gauss Meter Using Giant Magnetoimpedance Effect in Self Biased Amorphous Ribbon

  • Kollu, Pratap;Yoon, Seok-Soo;Kim, Gun-Woo;Angani, C.S.;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.194-198
    • /
    • 2010
  • In our present work, we developed a GMI (giant magnetoimpedance) sensor system to detect magnetic fields in the milli gauss range based on the asymmetric magnetoimpedance (AGMI) effect in Co-based amorphous ribbon with self bias field produced by field-annealing in open air. The system comprises magnetoimpedance sensor probe, signal conditioning circuits, A/D converter, USB controller, notebook computer, and program for measurement and display. Sensor probe was constructed by wire-bonding the cobalt based amorphous ribbon with dimensions $10\;mm\;{\times}\;1\;mm\;{\times}\;20\;{\mu}m$ on a printed circuit board. Negative feedback was used to remove the hysteresis and temperature dependence and to increase the linearity of the system. Sensitivity of the milli gauss meter was 0.3 V/Oe and the magnetic field resolution and environmental noise level were less than 0.01 Oe and 2 mOe, respectively, in an unshielded room.

A study on the Precision Measurement of Metal Electrical Resistivity (금속 전기비저항의 정밀측정에 관한 연구)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Han-Jun;Han, Sang-Ok;Park, Kang-Sic;Lee, Sae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.37-39
    • /
    • 2007
  • 금속의 전기 비저항 측정방법은 일반적으로 4단자, van der Pauw, Four-Point Probe(FPP), eddy current 방법 등이 있다. 이들의 측정방법들은 각각 다르지만 동일한 시료에 대한 전기 비저항 측정값은 거의 같은 결과를 나타내어 야 한다. 금속 전기 비저항의 정밀측정에 대한 연구를 위하여 비자성 금속인 STS 316 시료를 선정하여 측정한 결과 4단자와 van der Pauw 방법으로 측정된 비저항은 각각 $75.86{\mu}g\Omega{\cdot}cm$(2.273 %IACS), $75.80{\mu}g\Omega{\cdot}cm$(2.275 %IACS)이며, 측정 불확도는 0.25 %로서 거의 동등한 결과를 나타냈고, Four Point Probe(FPP) 방법으로 측정된 비저항은 $75.36{\mu}g\Omega{\cdot}cm$(2.288 %IACS), 측정 불확도는 0.45 %, eddy current 방법으로 측정된 비저항은 $76.63{\mu}g\Omega{\cdot}cm$(2.25 %IACS), 측정 불확도는 0.64 %로 나타났다.

  • PDF

A Study on the High Temperature Thermal Conductivity Measurement of Nanofluid Using a Two-Phase Model (2상 모델을 이용한 나노유체의 고온 열전도도 측정 연구)

  • Park, Sang-Il;Lee, Wook-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.153-156
    • /
    • 2010
  • The effective thermal conductivity of two-phase materials such as unbonded silica sands saturated with a nanofluid was measured at high temperature using the transient thermal probe method. The nanofluid used in this study was a water-based mixture of 0.1 vol% $Al_2O_3$ nanoparticles with a diameter of 45 nm. The convection problem for fluids was prevented with this measurement method because the fluid was confined to within very small pore spaces. Based on the prediction model for unbonded sands, the thermal conductivities of the saturating nanofluid at high temperatures could be determined with the measured effective thermal conductivities for the two-phase material. In the results, increases in the thermal conductivity ratios of the nanofluid to pure water when temperatures were varied from $30^{\circ}$ to $80^{\circ}C$ were within the range of 4.87%~5.48%.