• Title/Summary/Keyword: 4차원 CAD

Search Result 120, Processing Time 0.028 seconds

Man-hour Reduction by Development of Library in a 3-D Design System for Plant Projects (플랜트 프로젝트용 3차원 디자인 시스템에서 라이브러리 개발을 통한 설계시간 감축)

  • Lee, Jung-Hyun;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.5 no.4
    • /
    • pp.68-72
    • /
    • 2009
  • This study discussed for library development of the 3 dimensional design system for the progressive developmental world wide plant industry. Its previous background had spatial limitation by utilizing 2 dimensional CAD. This work presented an effective mode for improving man-hour by applying with 3 dimensioal design system through theoretical definition, category, and means of basic man-hour. We researched an effective method for reducing man-hour through applied example on the actual project by comprehending affection of extra development for library on man-hour.

  • PDF

An Analysis of the Color Palette using 3D Visual Presentation (3차원 프리젠테이션을 이용한 실내디자인 색채팔레트 분석)

  • 김은정;이현수
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2001.11a
    • /
    • pp.51-55
    • /
    • 2001
  • Usual1y, common color systems have been expressed with two dimensional method such as books. We think that the three dimensional presentation of color is very useful to know the characteristics of the color palette for interior design. And, it might be convenient far planning the colors of interior design. This paper deals with the method of 3D presentation. We used AutoCAD 2000 and 3dMax 4.0 in modeling the color system. By presenting which parts of the munsell color system used in the colors which have appeared in interior design three dimensionally, the guideline fur the interior designers can be suggested.

  • PDF

Design and Structural Analysis of Leg Extension Machine (레그 익스텐션 기구의 설계 및 구조해석)

  • 이종선;백두성
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.4
    • /
    • pp.326-330
    • /
    • 2004
  • This study is object to design and structural analysis of Leg Extension Machine. Design tool is AutoCAD and structural analysis of Leg Extension Machine using result from ANSYS Code. This structural analysis results, many variables such as boundary condition, constraint condition and load condition are considered.

  • PDF

An Estimation of Discharge Coefficients with the Variations of Tyrolean Weir Screen Angle (티롤리안 위어 스크린 경사에 따른 유량계수 추정)

  • Yu, Chang Hwan;Beck, Yoo Hyun;Oh, Yeun Kun;Choi, Ik Bae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.227-227
    • /
    • 2018
  • 티롤리안 위어(Tyrolean Weir)는 유송잡물 및 유사의 영향이 비교적 높은 산악지역에 설치되는 취수구조물로 대부분 저류면적이 제한된 자류식(Run-Off River) 수력발전 및 소규모 농업용수 취수시설에 적합한 구조물이다. 티롤리안 위어는 일반적인 취수시설과 비교하여 구조물의 규모를 최소화할 수 있어 친환경적 취수구조물로 분류할 수 있다. 아직까지 국내에서는 설치사례가 없고 연구성과 또한 부족하여 적용성에 한계가 있는 것이 사실이다. 본 연구에서는 3차원 유동해석 프로그램인 FLOW-3D를 이용하여 티롤리안 위어의 월류흐름특성을 분석하고 스크린 경사와 월류수위 변화에 따른 유량계수를 산정하였다. 티롤리안 위어 스크린경사에 따른 수치모형실험을 위해 3차원 AUTO CAD 프로그램을 이용하여 위어폭 11.0m, 길이 10m 및 수로경사 2:3의 솔리드 모형을 구성하였으며, 티롤리안 위어 스크린 경사를 $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$, $30^{\circ}$로 변화시키며 월류수심 변화에 따른 수치모형실험을 수행하였다. 금회 수치해석 분석결과 다음과 같은 결론을 얻을 수 있었다. 1) 티롤리안 위어 스크린 경사가 증가할수록 유량계수가 증가하였다. 2) 월류수심 1.4m일때 월류량의 표준편차는 0.767이며 월류수심 4.4m일때 표준편차는 9.580으로 월류수심이 증가할수록 스크린 경사에 따른 표준편차는 증가하는 것으로 확인되었다. 3) 티롤리안 위어 스크린 경사가 클수록 월류수심은 감소하고 접근수로부 유속이 증가하였으며 스크린 경사가 작을수록 월류수심은 증가하고 유속이 감소하는 경향을 확인하였다. 4) 티롤리안 위어 스크린 경사가 작고 월류수심이 클수록 광정위어와 유사한 흐름특성을 보였다.

  • PDF

Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases (두경부암 환자에 대한 선량체적 히스토그램에 따른 토모치료외 선형가속기기반 세기변조방사선치료의 정량적 비교)

  • Kim, Dong-Wook;Yoon, Myong-Geun;Park, Sung-Yong;Lee, Se-Byeong;Shin, Dong-Ho;Lee, Doo-Hyeon;Kwak, Jung-Won;Park, So-Ah;Lim, Young-Kyung;Kim, Jin-Sung;Shin, Jung-Wook;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.89-94
    • /
    • 2008
  • TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.

  • PDF

Methods of Merging a 3D Replica and Ease Distribution for Woman's Pant Patterns (여성용 바지 패턴 설계를 위한 3차원 밀착 패턴 여유량 부가와 레플리카 조합 방법)

  • Wu, Yanjun;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.4
    • /
    • pp.443-455
    • /
    • 2012
  • In this research, a woman matched to the average Korean standard size specification of 21-24 years of age was scanned using Cyberware. Rapidform 2004 was used to separate the body zone into fit zone, action zone and design zone, depending on the function of the lower body. Each divided body zone expanded radially using 'offset' by 1.60mm at the cross section of the waist, and 6.36mm at the hip level. Resultant ease values were 1cm and 4cm along the waistline and hipline (respectively), as recommended in previous research. 2C-AN program and Yuka CAD was used to develop a pant pattern from the enlarged 3D body surface blocks. A total of five pants were constructed using conventional fabrics for light weight formal pants. The appearance of the experimental pants were evaluated by five clothing-major evaluators using a questionnaire that consisted of 21 questions. In addition, functional aspects of the experimental pants were also evaluated by wearer while performing five postures for the measurement of ease of movement. It was found that, the method of regional offset and suggested 3D to 2D pattern development generate reasonably good pant patterns. Among the pattern block arrangements, the method B was evaluated as the best way to generate formal pants from the tight-fit pattern, which fit smoothly over the lower body for maintaining ease of movement.

Development of Building Monitoring Techniques Using Augmented Reality (증강현실을 이용한 건물 모니터링 기법 개발)

  • Jeong, Seong-Su;Heo, Joon;Woo, Sun-Kyu
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.6
    • /
    • pp.3-12
    • /
    • 2009
  • In order to effectively distribute the resources, it is very critical to understand the status or progress of construction site quickly and accurately. Augmented Reality (AR) can provide this situation with information which is convenient and intuitive. Conventional implementation of AR in outdoor or construction site condition requires additional sensors or markers to track the position and direction of camera. This research is aimed to develop the technologies which can be utilized in gathering the information of constructing or constructed buildings and structures. The AR technique that does not require additional devices except for the camera was implemented to simplify the system and improve utility in inaccessible area. In order to do so, the position of camera's perspective center and direction of camera was estimated using exterior orientation techniques. And 3D drawing model of building was projected and overlapped using this information. The result shows that by using this technique, the virtual drawing image was registered on real image with few pixels of error. The technique and procedure introduced in this paper simplifies the hardware organization of AR system that makes it easier for the AR technology to be utilized with ease in construction site. Moreover, this technique will help the AR to be utilized even in inaccessible areas. In addition to this, it is expected that combining this technique and 4D CAD technology can provide the project manager with more intuitive and comprehensive information that simplifies the monitoring work of construction progress and planning.

Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data (3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계)

  • Park, Soon-Jee;Choi, Sin-Ae
    • Fashion & Textile Research Journal
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF THE JAWS AT THE SIMULATED BILATERAL AND UNILATERAL CLENCHINGS (양측성 및 편측성 이악물기시 상하악골 응력변화 및 변위에 관한 3차원 유한요소법적 연구)

  • Heo, Hoon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.71-92
    • /
    • 1999
  • This study is to analyze the stress and displacement on the jaws during the bilateral and unilateral clenching task on three dimensional finite element model of the dentated skull. For this study, the computed tomography(G.E.8800 Quick, USA) was used to scan the total length of human skull in the frontal plane at 1.9mm intervals. The CAD data were extracted from the tomograms through digitizer(Summa Sketch III, USA) and then reconstructed by means of the spline method in the CAD program. In this project, a commercial software I-DEAS(Master Series ver-sion 3.0, SDRC Inc, USA) was used for three-dimensional stress analysis on the finite element model. which consists of articular disc, maxilla, mandible, teeth, periodontal ligament and cranium. The results are as follows. ; 1. During the bilateral clenching, each major muscle forces caused high stresses on various areas of skull: masseter muscle on articular disc and teeth ; temporal muscle on mandible and periodontal ligament ; medial pterygoid muscle on the temporomandibular joint. During the unilateral clenching, masseter muscle induced the maximum stress ; medial pterygoid muscle the minimum stress. 2. During the bilateral clenching, higher compressive stresses on articular disc were generated by the masseter muscle and higher deformation occurred on the most front outer sites. And during the unilateral clenching, temporal muscle and medial pterygoid muscle exerted their forces to twist temporomandibular joint area of the balancing side and induced a higher compressive stresses on the front outer sites of articular disc. 3. During the bilateral clenching, the masseter muscle bended the mandible outwardly, and then caused tensile stresses on the lingual surface of mandibular symphysis. And the medial pterygoid muscle caused tensile stresses on the labial surface of mandibular symphysis. 4. When each muscles were simultaneously applied on jaws, a high stress and displacement took place on mandible rather than on the maxilla. Also, a high stress and displacement took place during the unilateral clenching rather than during the bilateral clenching.

  • PDF

Evaluation of the dimensional change of 3D-printed complete denture after post-curing (후경화에 따른 3차원 프린팅 의치의 체적변화)

  • Suyeon, Lee;Younghun, Kwak;Eunchul, Park;Heejung, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.233-241
    • /
    • 2022
  • Purpose: The purpose of this study was to assess the dimensional change of 3D-printed dentures after post-curing. Materials and Methods: The upper and lower dentures were designed in Exocad DentalCAD software and exported as STL files. The upper and lower dentures were printed from 10 STL files using a DLP-type dental 3D printer. The printed upper and lower dentures were cleaned, and a scan file was created using a model scanner before and after post-curing. The dimensional change was evaluated by superimposing the scanned denture files before and after post-curing and measuring the distance between measurement points on the denture. SPSS was used for statistics, and the level of significance was 5%. Results: The maxillary denture reduced in size during post-curing, with the most notable color change occurring in the posterior palatal region. The reduction in anteroposterior maxillary denture length (A-D, A-E, A-F), as well as the distance between the first molars on both sides (B-C), was statistically significant. After post-curing, the mandibular denture showed more noticeable color change in the posteriorly buccal and lingual region. The decrease of length on the posterior (A-M, A-D, A-E, A-L, A-H, A-I, H-I) and lingual (J-K, L-M) sides of the denture were statistically significant. Conclusion: There was significant dimensional change in both the length and width of the 3D-printed maxillary and mandibular dentures after post-curing in this experiment. Consequently, it is seemed necessary to develop post-curing techniques and materials that reduce such denture deformation.