• Title/Summary/Keyword: 4차원 자기공명영상

Search Result 38, Processing Time 0.024 seconds

A case of congenital ductus arteriosus aneurysm (Congenital ductus arteriosus aneurysm 1례)

  • Wang, Sheng Wen;Kim, Ji Eun;Lee, Young Seok;Lee, Young Ah
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1363-1366
    • /
    • 2006
  • Aneurysmal dilatation of the ductus arteriosis has been considered a rare but potentially fatal abnormality. The mechanism of ductal aneurysmal formation remains uncertain. Plain chest radiography has proven helpful in the diagnosis of ductus arteriosus aneurysm (DAA), before the application of transthoracic echocardiography. The transthoracic echocardiography is an important tool for the diagnosis and follow-up of DAA. We present a case of congenital ductus arteriosus aneurysm in a newborn, that was an incidental discovery. The diagnosis was made by echocardiography, three-dimensional surface rendering computed tomography (CT), and spontaneous regression after four weeks of follow-up.

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

Multi-modality MEdical Image Registration based on Moment Information and Surface Distance (모멘트 정보와 표면거리 기반 다중 모달리티 의료영상 정합)

  • 최유주;김민정;박지영;윤현주;정명진;홍승봉;김명희
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.224-238
    • /
    • 2004
  • Multi-modality image registration is a widely used image processing technique to obtain composite information from two different kinds of image sources. This study proposes an image registration method based on moment information and surface distance, which improves the previous surface-based registration method. The proposed method ensures stable registration results with low registration error without being subject to the initial position and direction of the object. In the preprocessing step, the surface points of the object are extracted, and then moment information is computed based on the surface points. Moment information is matched prior to fine registration based on the surface distance, in order to ensure stable registration results even when the initial positions and directions of the objects are very different. Moreover, surface comer sampling algorithm has been used in extracting representative surface points of the image to overcome the limits of the existed random sampling or systematic sampling methods. The proposed method has been applied to brain MRI(Magnetic Resonance Imaging) and PET(Positron Emission Tomography), and its accuracy and stability were verified through registration error ratio and visual inspection of the 2D/3D registration result images.

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

Modeling of the Artery Tree in the Human Upper Extremity and Numerical Simulation of Blood Flow in the Artery Tree (상지동맥 혈관계의 모델링과 혈유동의 전산수치해석)

  • Kim, Keewon;Kim, Jaeuk U.;Beak, Hyun Man;Kim, Sung Kyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.221-226
    • /
    • 2016
  • Since arterial disease in the upper extremity is less common than that in the lower extremity, experimental and numerical investigations related to upper extremity have been rarely performed. We created a three-dimensional model of the arteries, larger than approximately 1 mm, in a Korean adult's left hand (from brachial to digital arteries), from 3T magnetic resonance imaging (MRI) data. For the first time, a three-dimensional computational fluid dynamic method was employed to investigate blood flow velocity, blood pressure variation, and wall shear stress (WSS) on this complicated artery system. Investigations were done on physiological blood flows near the branches of radial and deep palmar arch arteries, and ulnar and superficial palmar arch arteries. The flow is assumed to be laminar and the fluid is assumed to be Newtonian, with density and viscosity properties of plasma.

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

A Study on the Status of Medical Equipment and Radiological Technologists using Big Data for Health Care: Based on Data for 2020-2021 (보건의료 빅데이터를 활용한 의료장비 및 방사선사 인력 현황 연구 : 2020-2021년 자료를 기준으로)

  • Jang, Hyon-Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.667-673
    • /
    • 2021
  • As we enter the era of the 4th industrial revolution, it is judged that the scope of work of radiologists will be further expanded according to the innovation and advancement of radiation medical technology development. In this study, the current status of medical equipment and radiology technicians was identified, and basic data were provided for the plan for nurturing talents in the field of radiation medical technology in the era of the 4th industrial revolution, as well as career and employment counseling. Data from the second quarter of 2020 and the second quarter of 2021 were analyzed using health and medical big data. As a result of comparing the status of medical equipment by type in 2021 compared to 2020, C-Arm X-ray examination equipment increased by 5.83% to 6,638 units, followed by MRI examination equipment 1,811 units 5.29%, and angiography equipment 725 units 5.22% , general X-ray examination equipment 21,557 units increased 3.99%, CT examination equipment 2,136 units 3.03%, and breast examination equipment 3,425 units increased 3.00%. As a result of a comparison of the total number of radiologists in 2021 compared to 2020, the number was 29,038, an increase of 2.73%. As a result of comparing the status of radiographers by region, the increase was highest in the Gyeonggi region with 5.96%, followed by the Gangwon region with a 5.66% increase and the Chungnam region with a 3.81% increase. In a situation where the number of medical equipment and radiologist manpower is increasing, universities are developing specialized knowledge and practical competency through subject development related to the understanding and utilization of customized artificial intelligence and big data that can be applied in the medical radiation technology field in the era of the 4th industrial revolution. It is necessary to nurture qualified radiographers, and at the level of the association, it is thought that active policies are needed to create new jobs and improve employment.