• 제목/요약/키워드: 4단 가역 압연기

검색결과 2건 처리시간 0.015초

강판의 자동 형상제어 장치의 특성에 관한 연구 (A Study on the Characteristics of Automatic Flatness Control System for Stell Sheet)

  • 김순경;전연찬;김중완;김문경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.541-545
    • /
    • 1996
  • In this paper, The performance and functions of automatic flatness control system installed on the 4 hi-reversing mill and has been investigated under actualconditions. A new automatic flatness control system incorporates a measuring roll for measurement and correction calculations, hydraulic roll benders, selective roll cooling, and a programmable controller for interface and data logging. The test results are as following. The more the exit steel strip thickness is thick, the smaller the I value, and the more it is thin, the larger the I value. And, a complex distribution of strip tension was controlled, for example, not only a quarter buckle but also a simple center wave and edge wave. Because the tension deviation is larger at acceleration speed and deceleration speed than steady speed, so automatic flatness control system of contact type is better to adopt over 450 m/min, automatic flatness control system reduces rapidly large flatness deviation. The maximum I value of strip has been decreased to 13 I, and defects caused by poor flatness have been drastically decreased. And coolant temperature for work roll cooling system on the automatic flatness control system is better to adopt about 50-55 .deg. C.

  • PDF

냉각압연 가공용 자동 형상제어장치의 특성에 관한 연구 (A Study on the Characteristics of Automatic Flatness Control System for Cold Rolling)

  • 김문경;전언찬;김순경
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2901-2907
    • /
    • 1996
  • Flatness of cold rolled strip is vital to the quality of the product and productivity of the mill. Therefore, in recent year requirement for flatness control in strip rolling have become increasingly severe. The necessity for more accurate automatic gauge control and automatic flatness control(AFC) has increased by customer's requirement for cold rolled steel sheets with thinner gauge and better flatness quality. In this paper, the performance and functions of AFC system installed on the 4 hi-reversing mill has been investigated under actual conditions. The test results are as follows : The more strip thickness is thick, the smaller the I-value. The I-value is a strain measured by stressometer. Complex distributions of strip tension are controlled to remove not only a quarter buckle but also a simple center wave and edge wave. The defects caused by poor flatness have been drastically decreased. And a proper coolant temperature for work roll cooling system on the AFC system is about $50~55^{\circ}C$.