• Title/Summary/Keyword: 3d scanning

Search Result 1,479, Processing Time 0.031 seconds

A Comparison of the Effects of Silica and Hydroxyapatite Nanoparticles on Poly(ε-caprolactone)-Poly(ethylene glycol)-Poly(ε-caprolactone)/Chitosan Nanofibrous Scaffolds for Bone Tissue Engineering

  • Hokmabad, Vahideh Raeisdasteh;Davaran, Soodabeh;Aghazadeh, Marziyeh;Alizadeh, Effat;Salehi, Roya;Ramazani, Ali
    • Tissue Engineering and Regenerative Medicine
    • /
    • v.15 no.6
    • /
    • pp.735-750
    • /
    • 2018
  • BACKGROUND: The major challenge of tissue engineering is to develop constructions with suitable properties which would mimic the natural extracellular matrix to induce the proliferation and differentiation of cells. Poly(${\varepsilon}$-caprolactone)-poly(ethylene glycol)-poly(${\varepsilon}$-caprolactone) (PCL-PEG-PCL, PCEC), chitosan (CS), nano-silica ($n-SiO_2$) and nano-hydroxyapatite (n-HA) are biomaterials successfully applied for the preparation of 3D structures appropriate for tissue engineering. METHODS: We evaluated the effect of n-HA and $n-SiO_2$ incorporated PCEC-CS nanofibers on physical properties and osteogenic differentiation of human dental pulp stem cells (hDPSCs). Fourier transform infrared spectroscopy, field emission scanning electron microscope, transmission electron microscope, thermogravimetric analysis, contact angle and mechanical test were applied to evaluate the physicochemical properties of nanofibers. Cell adhesion and proliferation of hDPSCs and their osteoblastic differentiation on nanofibers were assessed using MTT assay, DAPI staining, alizarin red S staining, and QRT-PCR assay. RESULTS: All the samples demonstrated bead-less morphologies with an average diameter in the range of 190-260 nm. The mechanical test studies showed that scaffolds incorporated with n-HA had a higher tensile strength than ones incorporated with $n-SiO_2$. While the hydrophilicity of $n-SiO_2$ incorporated PCEC-CS nanofibers was higher than that of samples enriched with n-HA. Cell adhesion and proliferation studies showed that n-HA incorporated nanofibers were slightly superior to $n-SiO_2$ incorporated ones. Alizarin red S staining and QRT-PCR analysis confirmed the osteogenic differentiation of hDPSCs on PCEC-CS nanofibers incorporated with n-HA and $n-SiO_2$. CONCLUSION: Compared to other groups, PCEC-CS nanofibers incorporated with 15 wt% n-HA were able to support more cell adhesion and differentiation, thus are better candidates for bone tissue engineering applications.

The dimension analysis of prepared natural teeth for developing customized zirconia block (맞춤형 지르코니아 블락 제작을 위한 삭제된 치아의 평균 크기 분석)

  • Kim, Min-Hyuk;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.381-388
    • /
    • 2017
  • Purpose: Unpredictable shrinkage of zirconia during sintering process causes discrepancy. Therefore, there have been attempts to reduce discrepancy by milling zirconia after sintering. However, due to the hardness of sintered zirconia, milling takes longer time, causes damage to the machine and causes chip formation. With customized zirconia block using the mean dimension of prepared natural dentition, it is expected to overcome these shortcomings. Materials and methods: The mean dimension of prepared natural dentition was analyzed as STL file after scanning of prepared teeth treated at SNUDH. The transverse, frontal and sagittal planes were set using Mimics and Photoshop. 3D volume was projected on each plane, and the outer line was measured through external tangent line, and the inner line was measured through inflection point of tangent line. Results: The mean height of prepared incisal (N = 57) is $6.60{\pm}1.05mm$, mesiodistal length is $2.98{\pm}0.73mm$, buccolingual length is $2.04{\pm}0.73mm$. The mean height of prepared premolar (N = 15) is $5.37{\pm}1.49mm$, mesiodistal length is $4.10{\pm}1.78mm$, buccolingual length is $5.86{\pm}1.55mm$. And the mean height of prepared molar (N = 13) is $5.11{\pm}1.29mm$, mesiodistal length is $6.80{\pm}1.18mm$, buccolingual length is $7.34{\pm}1.40mm$. Conclusion: Using the mean dimension of prepared natural dentition, it is expected to be able to fabricate customized zirconia block.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

Manufacturing Techniques of Bronze Medium Mortars(Jungwangu, 中碗口) in Joseon Dynasty (조선시대 중완구의 제작 기술)

  • Huh, Ilkwon;Kim, Haesol
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.161-182
    • /
    • 2021
  • A jungwangu, a type of medium-sized mortar, is a firearm with a barrel and a bowl-shaped projectileloading component. A bigyeokjincheonroe (bombshell) or a danseok (stone ball) could be used as a projectile. According to the Hwaposik eonhae (Korean Translation of the Method of Production and Use of Artillery, 1635) by Yi Seo, mortars were classified into four types according to its size: large, medium, small, or extra-small. A total of three mortars from the Joseon period have survived, including one large mortar (Treasure No. 857) and two medium versions (Treasure Nos. 858 and 859). In this study, the production method for medium mortars was investigated based on scientific analysis of the two extant medium mortars, respectively housed in the Jinju National Museum (Treasure No. 858) and the Korea Naval Academy Museum (Treasure No. 859). Since only two medium mortars remain in Korea, detailed specifications were compared between them based on precise 3D scanning information of the items, and the measurements were compared with the figures in relevant records from the period. According to the investigation, the two mortars showed only a minute difference in overall size but their weight differed by 5,507 grams. In particular, the location of the wick hole and the length of the handle were distinct. The extant medium mortars are highly similar to the specifications listed in the Hwaposik eonhae. The composition of the medium mortars was analyzed and compared with other bronze gunpowder weapons. The surface composition analysis showed that the medium mortars were made of a ternary alloy of Cu-Sn-Pb with average respective proportions of (wt%) 85.24, 10.16, and 2.98. The material composition of the medium mortars was very similar to the average composition of the small gun from the Joseon period analyzed in previous research. It also showed a similarity with that of bronze gun-metal from medieval Europe. The casting technique was investigated based on a casting defect on the surface and the CT image. Judging by the mold line on the side, it appears that they were made in a piece-mold wherein the mold was halved and using a vertical design with molten metal poured through the end of the chamber and the muzzle was at the bottom. Chaplets, an auxiliary device that fixed the mold and the core to the barrel wall, were identified, which may have been applied to maintain the uniformity of the barrel wall. While the two medium mortars (Treasure Nos. 858 and 859) are highly similar to each other in appearance, considering the difference in the arrangement of the chaplets between the two items it is likely that a different mold design was used for each item.

Structural and functional characteristics of rock-boring clam Barnea manilensis (암석을 천공하는 돌맛조개(Barnea manilensis)의 구조 및 기능)

  • Ji Yeong Kim;Yun Jeon Ahn;Tae Jin Kim;Seung Min Won;Seung Won Lee;Jongwon Song;Jeongeun Bak
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.413-422
    • /
    • 2022
  • Barnea manilensis is a bivalve which bores soft rocks, such as, limestone or mudstone in the low intertidal zone. They make burrows which have narrow entrances and wide interiors and live in these burrows for a lifetime. In this study, the morphology and the microstructure of the valve of rock-boring clam B. manilensis were observed using a stereoscopic microscope and FE-SEM, respectively. The chemical composition of specific part of the valve was assessed by energy dispersive X-ray spectroscopy (EDS) analysis. 3D modeling and structural dynamic analysis were used to simulate the boring behavior of B. manilensis. Microscopy results showed that the valve was asymmetric with plow-like spikes which were located on the anterior surface of the valve and were distributed in a specific direction. The anterior parts of the valve were thicker than the posterior parts. EDS results indicated that the valve mainly consisted of calcium carbonate, while metal elements, such as, Al, Si, Mn, Fe, and Mg were detected on the outer surface of the anterior spikes. It was assumed that the metal elements increased the strength of the valve, thus helping the B. manilensis to bore sediment. The simulation showed that spikes located on the anterior part of the valve received a load at all angles. It was suggested that the anterior part of the shell received the load while drilling rocks. The boring mechanism using the amorphous valve of B. manilensis is expected to be used as basic data to devise an efficient drilling mechanism.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

The effects of desensitizing agents, bonding resin and tooth brushing on dentin permeability, in vitro (지각과민 처치제 후 접착레진 처리가 상아질 투과도에 미치는 영향)

  • Hong, Seung-Woo;Park, No-Je;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.165-176
    • /
    • 2014
  • Purpose: The effects of desensitizing agent are often for a short duration. One of the reasons is believed to be wear of desensitizing agent by tooth brushing. To reduce the wear and make the duration longer, dental bonding resin was applied and the changes of dentin permeability after toothbrushing were measured. Materials and methods: Extracted teeth free from caries were chosen. Coronal dentin discs with thickness of 1 mm were prepared. Using the split chamber device developed by Pashely, hydraulic conductance and scanning electron microscope images (SEM) were compared and contrasted before and immediately after the application of desensitizing agent and bonding resin and then after equivalent tooth brushing of 1 week, 2 weeks, and 6 weeks. Four commercially available desensitizing agents were used in this study; they were All-Bond 2, Seal & Protect, Gluma, and MS Coat. And Dentin/Enamel Bonding resin (Bisco Inc.) was used. The results of this study are as follows. Results: On all specimens, the hydraulic conductance decreased after the application of tooth desensitizing agent and bonding resin. Compared with the specimens treated only with desensitizer, the specimens treated with All-Bond 2, Gluma, MS Coat and plus D/E bonding resin had a little increase in hydraulic conductance after 1, 2 and 6-week tooth brushing. In case of Seal & Protect, the specimens showed the same result only after 6-week tooth brushing. On examination of SEM, the dentinal tubule diameter had decreased after treatment of desensitizing agents and bonding resin. And the specimens treated with All-Bond2, Seal&Protect, Gluma, MS Coat and plus D/E bonding resin had an significant decrease in diameter of dentinal tubule after 6-week tooth brushing. Conclusion: According to the results of this study, it is effective to use bonding resin after application of desensitizer in reducing the wear by tooth brushing and making the duration longer. In this study, just 6-week tooth brushing was performed, and it is not enough to regard it as a long-term data. So further study is needed and more perfect method for treating dentin hypersensitivity should be developed.

Development of Oligonucleotide Chip for Detection of Drug-Resistant Mycobacterium Tuberculosis (약제내성 결핵균의 검출을 위한 Oligonucleotide Chip의 개발)

  • Song, Eunsil;Park, Heekyung;Jang, Hyunjung;Kim, Hyomyung;Chang, Chulhun L.;Kim, Cheolmin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.1
    • /
    • pp.41-58
    • /
    • 2003
  • Background : The resurgence of tuberculosis and the widespread emergence of multidrug-resistant M. tuberculosis have emphasized the importance of rapid and accurate diagnostic procedures. Recently, the oligonucleotide chip has proven to be a useful tool in the rapid diagnosis of infectious diseases. The purpose of this study was to rapidly and accurately detect specific mutations in the rpoB, katG and rpsL genes associated with rifampin, isoniazid and streptomycin resistance in M. tuberculosis, respectively, using a single oligonucleotide chip. Method : For detection of drug-resistance, 7 wild-type and 13 mutant-type probes for rifampin, 2 wild-type and 3 mutant-type probes for isoniazid, and 2 wild-type and 2 mutant-type probes for streptomycin were designed and spotted onto glass slides. Fifty-five cultured samples of M. tuberculosis were amplified by PCR, and then underwent hybridization and scanning. Direct sequencing was done to verify the results from the oligonucleotide chip and to analyze the types of mutations. Result : Thirty-five cases out of 40 rifampin-resistant strains(~88%) had mutations in the rpoB gene. One case had a new mutation(D516F, GAC R TTC) and another known mutation together. Twenty cases out of 42 isoniazid-resistant strains(~50%) had mutations in the katG gene, while 7 cases out of 9 streptomycin-resistant strains(~78%) had mutations in the rpsL gene. From these results, the oligonucleotide chip was confirmed to be able to detect the most frequent mutations from the genes associated with rifampin, isoniazid and streptomycin resistance. The results proved that the drug-resistance detection probes were specific. When the results from the oligonucleotide chip and DNA sequencing were compared, the types of mutations were exactly matched. Conclusion : The diagnostic oligonucleotide chip with mutation specific probes for drug resistance is a very reliable and useful tool for the rapid and accurate diagnosis of drug resistance against rifampin, isoniazid and streptomycin in M. tuberculosis infections.

Influence of the accuracy of abutment tooth preparation on the marginal adaptation of Co-Cr alloy copings fabricated with a selective laser sintering technology (지대치삭제의정확도가레이져신터링기술로제작된Co-Cr 코핑의변연적합도에미치는영향)

  • Kim, Seo-Rahng;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.337-344
    • /
    • 2015
  • Purpose: The purpose of present study is to examine the correlation between the accuracy of abutment preparation and the marginal adaptation of metal coping. With this view, this study compared the correlations regard to the three different manufacturing methods of selective laser sintering technique, milling and casting. Materials and methods: Two master models were made in a different way. First model with deep chamfer margin was prepared directly by a general clinician and the second model was designed by 3-D designing software program with the same abutment preparation principle and produced by computer aided manufacturing. 12 Co-Cr alloy copings were produced respectively with three different method; SLS system, CAD/CAM milling and conventional lost wax technique from each master model. The total 72 copings fully sit on the master model were stereoscopically evaluated at 40 points along the entire circumferential margin. Results: Significant differences in the absolute marginal discrepancies of Co- Cr copings from SLS system (P=.0231) and casting method (P<.0001) were shown between hand preparation model and computer designed model. However, no significant difference was found between the two model groups from milling method (P=.9962). Conclusion: Within the limitation of this study, the effect of the accuracy of abutment preparation on the marginal adaptation of Co-Cr coping is statistically significant in SLS system and casting group. The copings produced by SLS system exhibited the lowest marginal discrepancies among all groups, and the marginal gap of this method group was influenced by the accuracy of the abutment preparation.

Factors Affecting Pregnancy Rates on Transfer of Pronuclear Microinjected Embryos in Korean Black Goats (전핵 미세 주입법으로 생산된 한국흑염소 수정란의 이식 조건이 수태율에 미치는 영향)

  • Choi, Y.S.;Shin, H.G.;Jang, S.K.;Yang, H.S.;Lee, O.K.;Lee, D.S.;Cho, J.K.;Shin, S.T.
    • Journal of Embryo Transfer
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2007
  • This study was investigated factors affecting the pregnancy rates after transfer of pronuclear microinjected embryos for the production of transgenic Korean black goats. Embryo transfer was carried out in 343 recipient Korean black goats from September 1999 to June 2000. Estrus was induced by the insertion of intravaginal progesterone devices $CIDR^(R)$ for 2 weeks. A single injection of 400 IU equine chorionic gonadotropin was administered at 48h before $CIDR^(R)$ removal to increase the proportion of does cycling and ovulation rate. Good quality embryos were prepared by microinjection of DNA into the pronuclei of fertilized goat oocyte and cultured in vitro. Pronuclear microinjected $1{\sim}8$ cell stage embryos were surgically transferred into the oviducts of the recipient at day 4 or 5 following $CIDR^(R)$ removal, and morula to blastocyst stage embryos were surgically transferred into uterus at day 9. Pregnancy was diagnosed by transrectal ultrasound scanning at $20{\sim}30d$ and 8 weeks following embryo transfer. The pregnancy rate was affected by several factors, such as estrus induction, the number of previous transfer, transfer site, stage of CL (corpus luteum), the number of recipient CL, stage of embryos and the number of transferred embryo. The pregnancy rate was significantly higher in recipients that came into estrus naturally than recipients that induced to come into estrus with $CIDR^(R)$(59.1% vs. 36.8%; P<0.05). The pregnancy rate was higher when the embryos were transferred into the left oviduct than transferred into the right oviduct (42.9% vs. 35.3%; P<0.05). The pregnancy rate of recipients with $CH_1$ (early) stage corpus hemorrhagicum in ovary was hi틴or than recipient with $CH_3$ (late) stage hemorrhagicum (47.5% vs. 17.9%; P<0.01). Higher pregnancy rates were obtained by transfer of 1-cell stage embryos into oviduct while late blastocysts (51.6% vs. 66.7%; P<0.01) into uterus. The pregnancy rates when 3 embryos were transferred to recipients were significantly higher than when 2 embryos we.e transferred (47.6% vs. 27.0%; P<0.05). Although there were no significant difference among the group, adhesion of reproductive organs, uterine size, ovulation rate of recipients, presence of large follicle and difficulty of transfer affected pregnancy rate of recipient. Higher pregnancy rates were obtained in the recipients with $8{\sim}15m$ diameter uterine horn as compared to the recipients with <5m diameter or >20mm diameter uterine hem (38.9%, 20% vs. 18.2%), in the recipients with large follicle in the ovulated ovary ipsilaterally (53.6% vs. 37.1%) and in the transfer which was carried out easily (39.2% vs. 27.8%, 0%). In conclusion, the high rate of pregnancy was achieved following transfer of pronuclear microinjected embryos when three or four 1-cell stage embryos were transferred into oviduct with $CH_1$ stage corpus hemorrhagicum in the ovary of recipient which came into estrus naturally.