• Title/Summary/Keyword: 3D-Image

Search Result 5,135, Processing Time 0.036 seconds

Evaluation of the Usefulness of Restricted Respiratory Period at the Time of Radiotherapy for Non-Small Cell Lung Cancer Patient (비소세포성 폐암 환자의 방사선 치료 시 제한 호흡 주기의 유용성 평가)

  • Park, So-Yeon;Ahn, Jong-Ho;Suh, Jung-Min;Kim, Yung-Il;Kim, Jin-Man;Choi, Byung-Ki;Pyo, Hong-Ryul;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.123-135
    • /
    • 2012
  • Purpose: It is essential to minimize the movement of tumor due to respiratory movement at the time of respiration controlled radiotherapy of non-small cell lung cancer patient. Accordingly, this Study aims to evaluate the usefulness of restricted respiratory period by comparing and analyzing the treatment plans that apply free and restricted respiration period respectively. Materials and Methods: After having conducted training on 9 non-small cell lung cancer patients (tumor n=10) from April to December 2011 by using 'signal monitored-breathing (guided- breathing)' method for the 'free respiratory period' measured on the basis of the regular respiratory period of the patents and 'restricted respiratory period' that was intentionally reduced, total of 10 CT images for each of the respiration phases were acquired by carrying out 4D CT for treatment planning purpose by using RPM and 4-dimensional computed tomography simulator. Visual gross tumor volume (GTV) and internal target volume (ITV) that each of the observer 1 and observer 2 has set were measured and compared on the CT image of each respiratory interval. Moreover, the amplitude of movement of tumor was measured by measuring the center of mass (COM) at the phase of 0% which is the end-inspiration (EI) and at the phase of 50% which is the end-exhalation (EE). In addition, both observers established treatment plan that applied the 2 respiratory periods, and mean dose to normal lung (MDTNL) was compared and analyzed through dose-volume histogram (DVH). Moreover, normal tissue complication probability (NTCP) of the normal lung volume was compared by using dose-volume histogram analysis program (DVH analyzer v.1) and statistical analysis was performed in order to carry out quantitative evaluation of the measured data. Results: As the result of the analysis of the treatment plan that applied the 'restricted respiratory period' of the observer 1 and observer 2, there was reduction rate of 38.75% in the 3-dimensional direction movement of the tumor in comparison to the 'free respiratory period' in the case of the observer 1, while there reduction rate was 41.10% in the case of the observer 2. The results of measurement and comparison of the volumes, GTV and ITV, there was reduction rate of $14.96{\pm}9.44%$ for observer 1 and $19.86{\pm}10.62%$ for observer 2 in the case of GTV, while there was reduction rate of $8.91{\pm}5.91%$ for observer 1 and $15.52{\pm}9.01%$ for observer 2 in the case of ITV. The results of analysis and comparison of MDTNL and NTCP illustrated the reduction rate of MDTNL $3.98{\pm}5.62%$ for observer 1 and $7.62{\pm}10.29%$ for observer 2 in the case of MDTNL, while there was reduction rate of $21.70{\pm}28.27%$ for observer 1 and $37.83{\pm}49.93%$ for observer 2 in the case of NTCP. In addition, the results of analysis of correlation between the resultant values of the 2 observers, while there was significant difference between the observers for the 'free respiratory period', there was no significantly different reduction rates between the observers for 'restricted respiratory period. Conclusion: It was possible to verify the usefulness and appropriateness of 'restricted respiratory period' at the time of respiration controlled radiotherapy on non-small cell lung cancer patient as the treatment plan that applied 'restricted respiratory period' illustrated relative reduction in the evaluation factors in comparison to the 'free respiratory period.

  • PDF

The Role of Radiotherapy in the Treatment of Portal Vein Thrombosis from Advanced Hepatocellular Carcinoma (진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료 효과)

  • Kim, Jung-Hoon;Choi, Eun-Kyung;Ahn, Seung-Do;Lee, Sang-Wook;Shin, Seong-Soo;Choi, Won-Sik;Lim, Young-Suk;Kim, Kang-Mo;Suh, Dong-Jin;Chung, Young-Wha;Lee, Young-Sang;Won, Hyung-Jin;Kim, Jong-Hoon
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.170-176
    • /
    • 2007
  • Purpose: To determine the role of radiotherapy for the treatment of portal vein thrombosis (PVT) from hepatocellular carcinoma (HCC). Material and Methods: A retrospective analysis was performed on 70 patients that had been diagnosed with HCC and were treated with three-dimensional conformal radiotherapy (3D-CRT) for the PVT. The radiation dose ranged from 40 Gy to 60 Gy (median dose: 48 Gy) and the biological effective dose (BED) ranged from 31.3 Gy to 78.0 $Gy_{10}$ (median dose: 61.6 $Gy_{10}$). Response was determined by measuring the extent of the PVT on a CT image at 0, 1 and 3 months after completion of the radiotherapy. The median follow-up period was 9 months. Results: The response rate was 47.1% (33 patients), with two patients (2.9%) showing a complete response, 31 patients (44.3%) showing a partial response, and 35 patients (50%) showing stable disease or no response. The 1-year progression-free survival rate was 60%, and the median progression-free survival time was 17 months. The median overall survival time was 11 months, the median survival time in the responders was 15 months and in the nonresponders was 8 months (p=0.032). Four patients (5.7%) had transient liver function impairment during treatment. Radiation induced liver disease (RILD) was observed in only one patient (1.4%). Conclusion: Three-dimensional conformal radiotherapy for the treatment of PVT from advanced HCC was a relatively effective and safe method.

The Three Dimensional Analysis on Nasal Airway Morphology in Class III Malocclusion (골격성 III급 부정교합자의 Nasal Airway 형태에 관한 3차원적 분석 연구)

  • Kim, Moon-Hwan;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.389-403
    • /
    • 2008
  • In Angle's Class III malocclusion, which has higher incidence in Korean than Western, depressed midfacial profile with protruded lower lips and mandible may give rise to many functional, esthetic, psychological, social problems. Due to the different malocclusion incidence according to racial differences, many previous studies focused on the relationship between Class II malocclusion and nasal airway obstruction. Previous studies used lateral cephalography which has limitations of 2 dimensional image with projection error and identification error. Therefore, the purpose of this study was to analyze morphologic differences in the nasal airway between normal occlusion and Angle's Class III malocclusion patients using 3-dimensional facial computed tomography. Thirteen normal occlusion(7 men and 6 women) and sixteen skeletal Class III(7 men and 9 women) patients were selected and 3-dimensional facial computed tomography taking was performed. Comparison between two group in volume and sectional area of nasal airway were carried out. The results were followed. 1. In the comparison of absolute nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 2. In the comparison of relative nasal airway volume, oropharyngeal space of experimental group were larger than control group but there are no significant difference in other. 3. In the oropharyngeal space width on frontal and lateral view, the similar tendency was revealed between two groups. 4. In the lateral curvature of nasal airway, the similar tendency was revealed between two groups.

Development of a vestibulo-ocular reflex measurement system for the study of cybersickness (사이버멀미 경감 연구를 위한 전정안구반사 측정 시스템 개발)

  • Jeon, Hyeonjin;Chang, EunHee;Wendimagegn, Tariku Weldtsadik;Park, Chan Hyun;Jeong, Ji Woon;Kim, Hyun Taek
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.27-38
    • /
    • 2015
  • Vestibulo-ocular reflex (VOR) is a compensatory response of the extraocular muscles generated by vestibular signals to stabilize images on the retina during head/body movements. It has been reported that mismatches between retinal and vestibular information, which cause motion sickness or cybersickness, modify VOR. To investigate the characteristic changes of VOR in subjects experiencing cybersickness, we developed a low-cost, multi-purpose VOR measurement system using LabVIEW and Arduino. To test the applicability of the system, we performed two experiments. In Experiment 1, horizontal and vertical VORs of four participants were measured using a vestibular autorotation task. In Experiment 2, eight participants were exposed to a virtual navigation to measure changes of VORs as an index of cybersickness. We observed significantly greater head rotations and eye movements while the participants were exposed to the virtual navigation than to a static image. The results suggest that the present system can help understand the psychophysiological mechanisms of cybersickness symptoms.

Weight Control Behaviors, Health-related Quality of Life and Nutritional Status by Overestimation of Body Image among Young Korean Females: Data from the Fifth Korea National Health and Nutrition Examination Survey, 2010-2011 (20·30대 여성의 체형 과대인식에 따른 체중조절행위, 삶의 질, 식행동 및 영양소 섭취상태: 2010-2011년 국민건강영양조사 자료 이용)

  • Park, Seulki;Hyun, Taisun;Lee, Hongmie
    • Korean Journal of Community Nutrition
    • /
    • v.20 no.5
    • /
    • pp.362-374
    • /
    • 2015
  • Objectives: This study was performed to investigate the effects of overestimation of their own body shape on weight control behaviors, mental condition, physical activity, dietary behavior, health-related quality of life, and nutritional status among young Korean females. Methods: A total of 1,514 women aged 20-39 years who are not pregnant and lactating among those who participated in the Fifth Korea National Health and Nutrition Examination Survey (2010~2011), were analyzed and grouped into underestimation (n=120), normal estimation (NE, n=840), and overestimation (OE, n=554), based on their body perception compared to actual percent ideal body weights. Variables were compared between OE group and NE group. Results: The subjects in OE group were significantly younger (29.5 vs. 30.5 years, respectively p < 0.05) and had lower body mass index (20.9 vs. 22.2 respectively, p < 0.01), health-related quality of life measured by EQ-5D (EuroQol-5 Dimension)(0.97 vs. 0.98 respectively, p < 0.05), nutrition adequacy ratio (NAR) of protein (0.91 vs. 0.93 respectively, p < 0.05), phosphorous (0.93 vs. 0.96 respectively, p < 0.05), and iron (0.70 vs. 0.75 respectively, p < 0.01), and index of nutrition quality (INQ) of iron (0.84 vs. 0.89 respectively, p < 0.05) compared to those in the NE group. The results of logistic regression showed that unmarried status (OR 1.32; 1.01~1.72) and severely underweight/underweight status (OR 1.94; 1.01~3.75)/(OR 1.81; 1.34~2.45) were significantly related to the probability of overestimation by the subjects. Significantly more women in OE group practiced fasting, skipping meals, and taking prescribed pills to lose body weights and had skipped breakfast compared to those in the NE group. Conclusions: The results of this study suggested that the Korean young women's distorted perception of own body shape may be associated with undesirable weight control behavior, low quality of life, and lower nutritional status. Therefore, nutrition education for this group should include information on correct body shape perception and its importance.

A Study on the Change of Cavity Area through Groundwater Injection Test under Pavement Cavity (도로하부 공동 내의 지하수 주입 실험을 통한 공동 영역 변화 연구)

  • Kim, Sang Mok;Choi, Hyeon;Yoon, Jin Sung;Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.267-275
    • /
    • 2020
  • Purpose: In this study, GPR exploration equipment, spray vehicles and flow meters, core drill, borehole image processing system(BIPS), 3D cavity imagery equipment, and cavity formatting equipment were used to identify this cavity growth process. Method: A certain amount of water was injected in proportion to the mass of the cavity, and the cavity was observed to expand as the injected water was drained out. The cavity rating change was evaluated by quantitatively evaluating the expansion factors and the speed of growth. Results: According to the results of examining the volume change through injection time - injection flow rate - volume increase for the four experimenters, the volume increase decreased as the injection time increased, and there was no further increase in volume if injected for one hour or so. Conclusion: In addition, the injection test analyzed the volumetric variation to determine whether the cause of the cavity occurrence was the effect of the underground burial in the vicinity of the cavity. Therefore, it was found that the cavity expansion is caused by the repetition of the relaxation soil collapse due to the groundwater flow and the loss of the collapsed soil below the cavity.

The thickness of facial and palatal bone of maxillary anterior natural teeth: radiographic analysis using computed tomography (전산화 단층 촬영을 이용한 상악 전치부 자연치의 순측과 구개측 골의 두께 계측)

  • Bae, Soo-Yong;Park, Jung-Chul;Sohn, Joo-Yeon;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.47 no.10
    • /
    • pp.669-676
    • /
    • 2009
  • Purpose : Anterior region is crucial area for esthetic implant restoration. However, the alveolar process undergoes atrophy after removal of teeth and creates unfavorable situation for implant installation. The knowledge of the thickness of alveolar bone is required to estimate and expect the bone resorption after extraction. The aim of this study is to measure facial, palatal and faciopalatal bone thickness on maxillary anterior teeth. Methods : Facial, palatal, and faciopalatal bone thickness were measured on the computed tomography (CT) images from 57 patients, using an image analyzer program (Ondemand$3D^{(R)}$, Cybermed, Seoul, Korea). Results : The thickness of facial bone in incisors, lateral incisors and canines were less than 1 mm. The thickness of facial bone increased from anterior to posterior region and the thickness of palatal bone increased from posterior to anterior region. Conclusion : The measurement can be used for planning implant surgery before extraction. CT has are clinically useful in the evaluation of thickness of alveolar bone.

  • PDF

Reevaluation of hydrogen gas dissolved cleaning solutions in single wafer megasonic cleaning

  • Kim, Hyeok-Min;Gang, Bong-Gyun;Lee, Seung-Ho;Kim, Jeong-In;Lee, Hui-Myeong;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.34.1-34.1
    • /
    • 2009
  • 1970년대 WernerKern에 의해서 개발된 RCA 습식 세정 공정은 이후 메가소닉 기술 개발과 더불어 현재까지반도체 세정 공정에서 필수 공정으로 알려져 있다. 하지만, 반도체패턴의 고집적화 미세화에 따라 메가소닉을 기반으로 하는 세정기술은 패턴 붕괴 및 나노 입자 제거의 한계를 드러내면서 난관에 봉착하고 있으며, 특히, 기존의 Batch식에서 매엽식으로 세정 방식이 전환은 새로운 개념의 메가소닉 기술 개발을 요구하게 되었다. 메가소닉을 사용한습식 세정공정은 메가소닉에 의한 캐비테이션 효과 (Cavitation Effect)에 따른 충격파 및음압 (Acoustic Streaming)에 의한 입자제거를 주요 메커니즘으로 한다. 메가소닉 주파수와 Boundary Layer 두께는, $\delta=\surd(2v/\omega)$($\delta$=두께, v=유체속도), $\omega=2{\pi}f$ (f=주파수), 으로 표현할 수 있다. 위의 식에 따르면, 메가소닉을 이용한 세정공정에서 주파수가 높아질수록 Boundary Layer의 두께가 감소하며, 이는제거 가능한 입자의 크기가 작아짐을 의미하며, 다시말해, 1 MHz 보다 2 MHz 메가소닉 세정장비에서 미세 입자 세정에 유리함을 예상할 수 있다. 본연구에서는 매엽식 세정장비를 사용하여, 1MHz 및 2MHz 콘-타입 (Cone-Type) 메가소닉 장치를 100nm이하 세정 입자에 대한 입자 제거효율을 평가하였다. 입자 제거 효율을 평가하기 위하여, 표준 형광입자(63nm/104nm 형광입자, Duke Scientifics, USA)를각각 IPA에 분산시킨 후, 실리콘 쿠폰 웨이퍼 ($20mm{\times}20mm$)를 일정시간 동안 Dipping 한 후, 고순도 질소로 건조시켜 오염하였다. 매엽식 세정장비(Aaron, Korea)에 1MHz와 2MHz의 콘-타입메가소닉 발진기 (Durasonic, Korea)를 각각 장착하였다.입자 오염 및 세정 후 입자 개수 측정 및 오염입자의 Mapping은 형광현미경 (LV100D, Nikon, Japan)과 소프트웨어(Image-proPlus, MediaCybernetics, USA)를 사용하여 평가하였으며, Hydrophone을 사용하여 메가소닉에서 발생되는 음압의 균일도를 각 조건에서 측정하였다. 각각의 세정공정은 1MHz와 2MHz 메가소닉 발진기 각각에서 1W, 3W, 5W 파워로 1분간 처리하였으며, 매질을 초순수를 사용하였다. 104nm 형광 입자는 1MHz 와 2 MHz 메가소닉 세정기와 모든 세정 공정조건에서 약 99%의 세정효율인 반면, 63nm 형광입자의 경우는 전체적인세정 결과가 80% 대로 감소하였다. 본 연구를 통하여, 입자크기의 미세화에 따른 입자제거효율이 크게 감소 하는 것을 확인할 수 있으며, 기존 Batch식 메가소닉 대비 단시간 및 낮은 전압에서 동일 혹은높은 세정 효율을 얻었다. 다만, 1MHz와 2MHz 메가소닉에서의 세정력은 큰 차이를 관찰 할 수 없었는데, 주파수변화에 따른 세정효율 측정을 위하여 미세 입자를 사용한 추가 실험이 필요 할 것이다.

  • PDF

Intelligent Tutoring System based on Wired and Wireless Internet for the living English 300-certifications Program (생활영어 300 인증제를 대비한 유무선 기반 지능형 교육 시스템)

  • Lee, Young-Seok;Cho, Jung-Won;Kim, Byung-Gyu;Park, Jung-Hwan;Kim, Su-Min;Choi, Byung-Uk
    • Journal of The Korean Association of Information Education
    • /
    • v.9 no.3
    • /
    • pp.533-548
    • /
    • 2005
  • According to the increasing of the internet infrastructure and growth of contents technology, the users can access an education service at anytime and anywhere. In a field of English education, especially, internet technology has enabled learners to communicate with their teachers and multimedia contents technology has been able to provide learner not only lots of interests, but also good effect on English learning. In this paper, we propose a method diagnosing learner's level by using some question-items, which consist of item's type and item's function. Futhermore, the proposed system can support three devices which are PC, PDA, and Mobile Phone on wired and wireless internet communication environments. Also, the system provides multimedia contents including flash movies, image, and audio contents. We have applied the system into real classroom, and we verified that the question-items that system provides has no problem, and our method could improve each learner skill on English education. Therefore, we expect that learner who uses the proposed system will get level-based English learning service at anytime and anywhere.

  • PDF

Automatic Extraction of Ascending Aorta and Ostium in Cardiac CT Angiography Images (심장 CT 혈관 조영 영상에서 대동맥 및 심문 자동 검출)

  • Kim, Hye-Ryun;Kang, Mi-Sun;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.1
    • /
    • pp.49-55
    • /
    • 2017
  • Computed tomographic angiography (CTA) is widely used in the diagnosis and treatment of coronary artery disease because it shows not only the whole anatomical structure of the cardiovascular three-dimensionally but also provides information on the lesion and type of plaque. However, due to the large size of the image, there is a limitation in manually extracting coronary arteries, and related researches are performed to automatically extract coronary arteries accurately. As the coronary artery originate from the ascending aorta, the ascending aorta and ostium should be detected to extract the coronary tree accurately. In this paper, we propose an automatic segmentation for the ostium as a starting structure of coronary artery in CTA. First, the region of the ascending aorta is initially detected by using Hough circle transform based on the relative position and size of the ascending aorta. Second, the volume of interest is defined to reduce the search range based on the initial area. Third, the refined ascending aorta is segmented by using a two-dimensional geodesic active contour. Finally, the two ostia are detected within the region of the refined ascending aorta. For the evaluation of our method, we measured the Euclidean distance between the result and the ground truths annotated manually by medical experts in 20 CTA images. The experimental results showed that the ostia were accurately detected.