• Title/Summary/Keyword: 3D video

Search Result 1,155, Processing Time 0.03 seconds

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Chromosome Analysis in Clinical Samples by Chromosome Diagnostic System Using Fluorescence in Situ Hybridization (국산 Fluorescence in Situ Hybridization 시스템을 이용한 다양한 검체에서의 염색체 분석)

  • Moon, Shin-Yong;Pang, Myung-Geol;Oh, Sun-Kyung;Ryu, Buom-Yong;Hwang, Do-Yeong;Jung, Byeong-Jun;Choe, Jin;Sohn, Cherl;Chang, Jun-Keun;Kim, Jong-Won;Kim, Seok-Hyun;Choi, Young-Min
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.335-340
    • /
    • 1997
  • Fluorescence in situ hybridization (FISH) techniques allow the enumeration of chromosome abnormalities and from a great potential for many clinical applications. In order to produce quantitative and reproducible results, expensive tools such as a cooled CCD camera and a computer software are required. We have developed a Chromosome Image Processing System (Chips) using FISH that allows the detection and mapping of the genetic aberrations. The aim of our study, therefore, is to evaluate the capabilities of our original system using a black-and-white video camera. As a model system, three repetitive DNA probes (D18Z1, DXZ1, and DYZ3) were hybridized to variety different clinical samples such as human metaphase spreads and interphase nuclei obtained from uncultured peripheral blood lymphocytes, uncultured amniocytes, and germ cells. The visualization of the FISH signals was performed using our system for image acquisition and pseudocoloring. FISH images were obtained by combining images from each of probes and DAPI counterstain captured separately. Using our original system, the aberrations of single or multiple chromosomes in a single hybridization experiment using chromosomes and interphase nuclei from a variety of cell types, including lymphocytes, amniocytes, sperm, and biopsied blastomeres, were enabled to evaluate. There were no differences in the image quality in accordance with FISH method, fluorochrome types, or different clinical samples. Always bright signals were detected using our system. Our system also yielded constant results. Our Chips would permit a level of performance of FISH analysis on metaphase chromosomes and interphase nuclei with unparalleled capabilities. Thus, it would be useful for clinical purposes.

  • PDF

Development of Valuation Framework for Estimating the Market Value of Media Contents (미디어 콘텐츠의 시장가치 산정을 위한 가치평가 프레임워크 개발)

  • Sung, Tae-Eung;Park, Hyun-Woo
    • Journal of Service Research and Studies
    • /
    • v.6 no.3
    • /
    • pp.29-40
    • /
    • 2016
  • Since the late 20th century, there has been much effort to improve the market value of media contents which are commercialized in a digital format, by fusing digital data of video, audio, numerals, characters with IT technology together. Then by what criteria and methodologies could the market value for the drama "Sons of the Sun" or the animated film 'Frozen', often referred to in the meida, be estimated? In the circumstances there has been little or no research on the valuation framework of media contents and the status of their valuation system development to date, we propose a practical valuation models for various purposes such as contents trading, review of investment adequacy, etc., by formalizing and presenting a contents valuation framework for the four types of media of movies, online games, and broadcasting commercials, and animations. Therefore, we develope computational methods of cash flows which includes production cost by media content types, provide reference databases associated with key variables of valuation (economic life cycle, discount rates, contents contribution and royalty rates), and finally propose the valuation framework of media contents based on both income approach and relief-from-royalty method which has been applied to valuation of intangible assets so far.

Causes of False Negative Bedside Head Impulse Test (나안 두부충동검사에서 위음성의 원인분석)

  • Kim, Dae-Young;Choi, Yoon-Gi;Kyung, Tae-Suk;Hwang, Jun-Ha;Kim, Hyun Ji;Lee, Seung Chul;Kim, Kyu-Sung
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.60 no.3
    • /
    • pp.107-111
    • /
    • 2017
  • Background and Objectives The bedside head impulse test (bHIT) in bare eyes often overlooks possible vestibular losses by missing the corrective saccade. This is why it is necessary to compare bHIT against video head impulse test (vHIT), which is more accurate in identifying vestibular losses than the bedside test. Subjects and Method A total of 51 vHIT positive ears underwent the study, and out of those, 47 were diagnosed with dizziness. bHIT and vHIT were performed for patients, and the occurrence rate of overt saccade (OS) was calculated. Results Among the 51 vHIT positive ears, 33 (64.7%) were bHIT positive ears and 18 ears (35.3%) were bHIT negative. Patterns of positive vHIT were classified as A: no corrective saccade, B: covert saccade (CS) only, C: OS only, and D: CS with OS (CS+OS), which were 45 out of 51 ears (88%). The occurrence rate of OS was higher in the bHIT positive group than in the bHIT negative group (p=0.05), and higher in the CS negative group (CS-) than in the CS positive group (CS+) (p<0.001). Conclusion Possible causes of false negative results of bHIT are seen as following: the absence of corrective (covert and overt) saccade, the occurrence of CS only, and missing the OS during the bHIT (probably due to low occurrence rate of OS). The occurrence of CS should be considered as an important factor in false negative bHIT when lowering the occurrence rate of OS.

The Effect of Other Behaviors and Lecture Satisfaction on Lecture Flow in Online Classes of Nursing Students' (간호대학생의 온라인 수업에서 딴짓과 강의만족도가 수업몰입에 미치는 영향)

  • Hyun-hee Ma;Hwa-Young Kim;Eun-Su Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.471-480
    • /
    • 2023
  • The purpose of this study is to confirm the effect of recording online classes and real-time video classes on other behaviors, lecture satisfaction, and lecture flow in during the COVID-19 period. Data were collected and analysis using a structured questionnaire from May 20th to June 4th in 2021 for 550 nursing students in the D University. As a result of the study, it was found that there were more others behaviors in record online classes than in real-time online classes (t=-2.00, p=.046), lecture satisfaction(t=-1.54, p=.124) and lecture flow in real-time online classes it was higher in the record online classes (t=-.63, p=.529), but it was not statistically significant. However, the 2nd year students who participated in the two types of online classes showed statistically significantly higher lecture satisfaction (t=13.55, p=.000) and lecture flow(t=4.48, p=.004). And 4 th grade students of others behaviors was statistically significantly lower (t=4.68, p=.003). In the multiple regression analysis, the main factor affecting lecture flow was lecture satisfaction, and the explanatory power of the model was 55.1% in record online classes (F=128.49, p <.01), and in real-time classes 47.2%(F=77.24, p<.01). In the future, research should be conducted to confirm the difference between the two types of online classes of the same instructor and the difference in other things, lecture satisfaction, and class commitment that appear after applying learner-centered learning.

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.

Effects of a Self-Help Program including Stretching Exercise on Reduction of Symptom in Patients with Fibromyalgia (신장운동을 포함한 자조관리프로그램이 섬유조직염환자의 증상완화에 미치는 효과)

  • Han, Sang-Sook
    • Journal of muscle and joint health
    • /
    • v.5 no.1
    • /
    • pp.39-56
    • /
    • 1998
  • This study was an quasi-experimental study, done to identify factors Influencing the reduction of symptoms in patients with fibromyalgia. The primary purpose of the study was to develop a Self-Help Program suitable for patients with fibromyalgia in Korea. The secondary purpose was to identify the effects of a Self-Help Program which included stretching exercise. This study was carried out between Feb. 24 and July 8, 1997 and patients in the study Included out patient diagnosed with fibromyalgia based on the criteria developed by the American College of Rheumatology(1990) and H, University which is a tertiary patient care clinic for Rheumatism. The experimental group included 38 patients who were residents of Seoul or Kyungi province, and a control group of 38 patients who were residents of other areas. The control patients were matched to the experimental group patients and they were selected considering the number of tender points on the Fibromyalgia Impact Questionnaire score and a score of self-efficacy. The experimental group participated in a Self-Help Program based on the American Arthritis Foundation(1995) guidelines. The program participants participated in a small group which consisted of 12-15 members attending the program once a week, for 6 weeks with each program lasted two to two and a half hours. The stretching exercise was carried out in each patient's home every day following the video tape exercise provided by the researcher, and the researcher provided encouragement and concern to the patients by calling them once a week. The number times the exercise was performed was divided by the number of participants to calculate the percentage of performance and determine the amount of exercise. Self-efficacy was measured by the Self-Efficacy Scale developed by Lorig et al. (1989) for arthritis patients. The degree of pain was converted to scores based on the Visual Analog Scale, the number of tender points was converted to scores based on the criteria of the ACR(1990) and of Yunus. Depression was measured by CES-D and physical disability, sleep disturbance, fatigue, and anxiety of patients with fibromyalgia were measured by the Fibromyalgia Impact Questionnaire. The level of the exercise performance was converted to scores using the number of times the exercise was performed following the video tape prepared by Association of Rheumatology Health Professionals. Data were analyzed by SPSS windows and the results ire described below. 1. The experimental group which participated in the Self-Help Program showed higher efficacy scores than the control group when both groups were analyzed for depression and the number of tender points as common variables(F=9.146, p=.003). 2. The experimental group which participated in the Self-Help Program showed lower scores than the control group, for pain, the number of tender points, depression, physical disability, fatigue, sleep disturbance and anxiety. These symptoms of fibromyalgia can all be seen to have subsided(F=9.483, p=.003 : F=32.680, p=.001 ; F=11.104, p=.001, F=5.344 : p=.024, F=7.630 : P=.007, F=15.6512, p=.003 : F= 7.5412, p=.008). 3. In the experimental group, the self-efficacy score for the first three weeks showed a positive correlation with the exercise-performance score for four to six weeks (r=.387, p=.043). 4. In the experimental group, the relationship between the level of exercise-performance and the reduction of symptoms showed a significant correlation only to physical disability(r= -.500, p=.001). 5. In the experimental group, the relationship between the self-efficacy score and pain, the number of tender points, depression, physical disability, fatigue, sleep disturbance and anxiety score showed inverse correlations and thus, a reduction of symptoms occured when the self-efficacy score increased(r=-.325, p=.004 ; r= -.253, p=.027, r=-.452, p=.001 : r=-.434, p=.001 ; r=-.316, p=.005 ; r=-.460, p=.001 ; r=-.397, p=.014). Therefore, self-efficacy improved following the Self-Help Program including the stretching exercise. It was also found that physical symptoms (pain, number of tender points, level physical disability) and psychological symptoms (depression, fatigue, sleep disturbance, anxiety) were reduced. Moreover, It was found that the higher the self-efficacy, the the higher the degree of achievement of goals set for the stretching exercises. In addition, the level of exercise-performance influenced the level of physical disability, one of the symptoms of fibromyalgia. Accordingly, the conclusions from this study are that exercise-performance and the reduction of symptoms is achieved through promotion of self-efficacy. Therefore, it is proposed that are the Self-Help Program including stretching exercises is an appropriate nursing intervention for the reduction of symptoms of fibromyalgia.

  • PDF

Surgery in Patients with Previous Resection of the Epileptogenic Zone Due to Intractable Epilepsy (일차 수술후 재발한 난치성 간질환자에 대한 수술)

  • Kim, Jae-Yeoup;Choi, Ha-Young;Kim, Young-Hyeoun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1300-1307
    • /
    • 2001
  • Purposes : This study reports the possible causes of seizure recurrence in patients underwent previous epilepsy surgery, and surgical strategy for resection of the additional epileptogenic zone locating at the distant area to the site of first resection. Methods : A total of 10 patients with previous surgery due to intractable epilepsy were studied. Five of these underwent standard temporal lobectomy, four extratemporal resection, and one corticoamygdalectomy. Seizure outcome of these were class III-IV. Evaluation methods for reoperation included MRI, 3D-surface rendering of MRI, PET, prologned video-EEG recording with surface electrodes and subdural grid electrodes. Additional resection was done in the frontal lobe in two, in the temporal lobe in three, in the parietal lobe in two, and in the supplementary sensori-motor area in two. Tumor in the superior frontal gyrus in the left hemisphere was removed in one patient. Extent of resection was decided based on the results of ictal subdural grid EEGs and MRI findings. Awake anesthesia and electrocortical stimulation were performed in the two patients for defining the eloquent area. Results : Histopathologic findings revealed extratemporal cortical dysplasia in six, hippocampal sclerosis and cortical dysplasia of the temporal neocortex in one, neuronal gliosis in two, and meningioma in one. Previous pathology of the five patients with cortical dysplasia in the second operation was hippocampal sclerosis plus cortical dysplasia of the temporal neocortex. After reoperation, seizure outcomes were class I in six, class II in three, class III in one at the mean follow-up period of 17.5 months. Characteristically, patients in class II-III after reoperation showed histopathologic findings of hippocampal sclerosis plus temporal neocortical cortical dysplasia plus extratemporal cortical dysplasia. Conclusions : Seizure recurrence after epilepsy surgery was related with the presence of an additional epileptogenic zone distant to the site of first operation, and the majority of the histopathology of the surgical specimens was cortical dysplasia. In particular, hippocampal sclerosis plus temporal neocortical cortical dysplasia was highly related with seizure recurrence in patients with previous operation. In these patients, multimodal evaluation methods were necessary in defining the additional epileptogenic zone.

  • PDF

Biomechanical Analysisz of Varying Backpack Loads on the Lower Limb Moving during Downhill Walking (내림 경사로 보행시 배낭 무게에 따른 하지 움직임의 운동역학적 분석)

  • Chae, Woen-Sik;Lee, Haeng-Seob;Jung, Jae-Hu;Kim, Dong-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • Objective : The purpose of this study was to conduct biomechanical analysis of varying backpack loads on the lower limb movements during downhill walking over $-20^{\circ}$ ramp. Method : Thirteen male university students (age: $23.5{\pm}2.1yrs$, height: $175.7{\pm}4.6cm$, weight: $651.9{\pm}55.5N$) who have no musculoskeletal disorder were recruited as the subjects. Each subject walked over $20^{\circ}$ ramp with four different backpack weights (0%, 10%, 20% and 30% of body weight) in random order at a speed of $1.0{\pm}0.1m/s$. Five digital camcorders and two force plates were used to obtain 3-d data and kinetics of the lower extremity. For each trial being analyzed, five critical instants were identified from the video recordings. Ground reaction force, loading rate, decay rate, and resultant joint moment of the ankle and the knee were determined by the inverse dynamics analysis. For each dependent variable, one-way ANOVA with repeated measures was used to determine whether there were significant differences among four different backpack weight conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results : The results of this study showed that the medio-lateral GRFs at RHC in 20% and 30% body weight were significantly greater than the corresponding value in 0% of body weight. A consistent increase in the vertical GRFs as backpack loads increased was observed. The valgus joint movement of the knee at RTO in 30% body weight was significantly greater than the corresponding values in 0% and 10% body weight. The increased valgus moment of 30% body weight observed in this phase was associated with decelerating and stabilizing effects on the knee joint. The results also showed that the extension and valgus joint moments of the knee were systematically affected by the backpack load during downhill walking. Conclusion : Since downhill walking while carrying heavy external loads in a backpack may lead to excessive knee joint moment, damage can occur to the joint structures such as joint capsule and ligaments. Therefore, excessive repetitions of downhill walking should be avoided if the lower extremity is subjected to abnormally high levels of load over an extended period of time.