• Title/Summary/Keyword: 3D vessel

Search Result 351, Processing Time 0.025 seconds

Clinical Review about Corrective Surgery of Tetralogy of Fallot (팔로사징증의 근치 수술에 관한 임상적 고찰)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.24 no.7
    • /
    • pp.674-684
    • /
    • 1991
  • The surgical treatment of tetralogy of Fallot [TOF] was initiated by Blalock and Taussig in 1945 with the establishment of the subclavian artery to pulmonary artery anastomosis. In an imaginative and daring effort, in 1954, Lillehei and collaborators [1955] using controlled cross-circulation, carried out the first intracardiac repair of TOF by closing the ventricular septal defect [VSD] and relieving the pulmonary stenosis under direct vision. Nowadays, total correction is the ideal operation for treatment of TOF and is accomplished with extracorporeal circulation. And the results of surgery for TOF have steadily improved over the years, thanks to important contributions of many surgeons. Nevertheless because of its protean physiologic and anatomic presentation, TOF continues to offer challenges to cardiologist and cardiac surgeons. Thirty two cases of TOF have undergone total corrective surgery using extracorporeal circulation in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, Inje University, from Oct. 1985 to Feb. 1990. Clinical considerations were applied to these cases and the results were obtained as follows. 1. The heart lung machine used for extracorporeal circulation was SarnsO 7000, 5-head roller pump, and the number and type of oxygenators were 10 of bubble type and 22 of membrane type. The mean bypass time was 148.9 minutes and the mean aortic cross clamp time was 123.8 minutes. The GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 2. 20 cases were male and 12 were female, the mean age was 8 years old and the mean body weight was 25Kg. 3. The preoperative symptoms were cyanosis [29 cases], squatting [27 cases] and etc. The mean values of preoperative Hb., Hct., and SaO2 were 16.5 gm /dl, 50.3%, and 78.5%. 4. Combined anomalies were noticed in 16 cases [50%]. Among them 10 cases were PFO and 6 cases were ASD. 5. The degree of aorta overriding were 25% in 5 cases, 25 ~ 50% in 22 cases and above 50% in 5 cases. The dPA/Ao [ratio of diameter of pulmonary artery trunk to ascending aorta] were below 25% in 5 cases, 25 ~ 50% in 10 cases, 50 ~ 70% in 6 cases and above 75% in 11 cases. 6. The types of RVOT [right ventricular outflow tract] stenosis were valvular and infundibular in 14 cases [43.6%], diffuse hypoplastic type in 12 cases [37.5%], infundibular in 5 cases, and valvular and supravalvular in 1 case. 7. One stage radical corrective surgery was applied to the all cases. In widening of the RVOT, 3 types of patches were used: MVOP [monocusp ventricular outflow patch, Polystan BioprosthesesO] in 3 cases, knitted Dacron vessel patches in 2 cases, and double layer with bovine pericardium and woven Dacron prosthesis in 26 cases. 8. Postoperative complications were occurred in 15 cases. Among them, low output syndrome were occurred in 10 cases [31.3%] and 2 of them were expired postoperatively.

  • PDF

A Study on Sexual Function of Women with Coronary Artery Disease (관상동맥질환 여성의 성기능에 관한 연구)

  • Kim, Choon Shim;So, Hyang Sook
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.1
    • /
    • pp.99-111
    • /
    • 2000
  • The purpose of this study was to identify risk factors related to sexual function of women with coronary artery disease, and to determine the predictors of sexual function. The study design, a descriptive correlational study, was done through structural questionnaire and interview. A total of 50 subjects from C University Hospital at Kwang-ju city who have undergone coronary angiography at department of cardiology were observed and interviewed from Feb. 22, 1999 to March. 23, 1999. The number of affected vessels, the level of total serum cholesterol, and the ejection fraction of 2-D echo cardiography were analyzed to evaluate the severity of coronary artery disease. And also type A behavior pattern, health behavior, Brief Index of Sexual Functioning for Women (BISF-W) were measured. The data obtained were analyzed using percentage, mean and standard deviation, t-test, ANOVA, Pearson's correlation coefficient, and stepwise multiple regression analysis via SPSS PC+. The results of this study were as follows: 1. The mean age of the subjects were 58.1 and 72.0% of those have been married over 30 years. Seventy two percentage were unemployed and monthly family income of 56.6% was less than 1,000,000 won (approximately $ 840). Eighty percent were in their postmenopausal state, and the frequency of sexual intercourse of 84.0% were two to three times per month. 2. The scores of type A behavior pattern were from 16 to 38(mean 24.94) and health behavior ranged from 21 to 43(mean 31.2). Abstinence from smoking, alcohol, and caffeine were best compliant factors and weight control and exercise were least abided ones. The result of 2D-ECHO EF showed that the half of the subjects were abnormal, and 24% had more than 240mg/dl of total serum cholesterol. The coronary angiography showed that 64% of the subjects had more than one affected vessels. 3. The predictors to explain the factor score of 'orgasm' were number of health examination, the pre- or post-menopausal state, protestant, number of coronary vessel affected, level of serum total cholesterol, and comorbid group of hypertension and diabetes, and it's total variance accounted for 52.4%. The predictors to explain the factor score of 'sexual activity' were comorbid group of hypertension and diabetes and type A behavior pattern, which accounted for 22.4% of total variance. The predictors to explain the factor score of 'sexual satisfaction' were type A behavior pattern, no religion, exercise, level of serum total cholesterol, and pre or post menopausal state, which accounted for 52.1%. The predictors to explain the factor score of 'sexual desire' were the period of marriage, type A behavior, employment or unemployment, and weight control, which accounted for 43.2%. The predictors to explain the factor score of 'external force of sexual functioning' were physical overload and exercise, which accounted for 41.1%. The predictors to explain the factor score of 'sexual activity' were family monthly income, catholics, and exercise, and which accounted for 35.4%. Above results lead us to some consensus that sexual function of women with coronary artery disease is related to various factors including vasogenic factors such as total serum cholesterol level, number of coronary vessel affected, an endocrinal factor such as menopausal state, and type A behavior pattern as a sociopshychological factor. And also health behaviors such as fitness care, overwork, weight control, and emotional tension are contributed to sexual function.

  • PDF

Characterizing Milk Production Related Genes in Holstein Using RNA-seq

  • Seo, Minseok;Lee, Hyun-Jeong;Kim, Kwondo;Caetano-Anolles, Kelsey;Jeong, Jin Young;Park, Sungkwon;Oh, Young Kyun;Cho, Seoae;Kim, Heebal
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.343-351
    • /
    • 2016
  • Although the chemical, physical, and nutritional properties of bovine milk have been extensively studied, only a few studies have attempted to characterize milk-synthesizing genes using RNA-seq data. RNA-seq data was collected from 21 Holstein samples, along with group information about milk production ability; milk yield; and protein, fat, and solid contents. Meta-analysis was employed in order to generally characterize genes related to milk production. In addition, we attempted to investigate the relationship between milk related traits, parity, and lactation period. We observed that milk fat is highly correlated with lactation period; this result indicates that this effect should be considered in the model in order to accurately detect milk production related genes. By employing our developed model, 271 genes were significantly (false discovery rate [FDR] adjusted p-value<0.1) detected as milk production related differentially expressed genes. Of these genes, five (albumin, nitric oxide synthase 3, RNA-binding region (RNP1, RRM) containing 3, secreted and transmembrane 1, and serine palmitoyltransferase, small subunit B) were technically validated using quantitative real-time polymerase chain reaction (qRT-PCR) in order to check the accuracy of RNA-seq analysis. Finally, 83 gene ontology biological processes including several blood vessel and mammary gland development related terms, were significantly detected using DAVID gene-set enrichment analysis. From these results, we observed that detected milk production related genes are highly enriched in the circulation system process and mammary gland related biological functions. In addition, we observed that detected genes including caveolin 1, mammary serum amyloid A3.2, lingual antimicrobial peptide, cathelicidin 4 (CATHL4), cathelicidin 6 (CATHL6) have been reported in other species as milk production related gene. For this reason, we concluded that our detected 271 genes would be strong candidates for determining milk production.

Anatomical Study for Vascular Distribution of the Perforator of Deep Inferior Epigastric Artery in Koreans (한국인에 있어 깊은아래배벽동맥(Deep Inferior Epigastric Artery)의 천공지(Perforator)에 관한 해부학적 연구)

  • Kim, Jee Hoon;Lee, Paik Kwon;Rhie, Jong Won;Kim, Deog Im;Han, Seung Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: The pedicle of transverse rectus abdominis myocutaneous(TRAM) flap and deep inferior epigastric arterial perforator flap is deep inferior epigastic artery (DIEA) and accurate anatomic knowledge about perforator of DIEA is very important for the elevation of these flap. The authors investigated a detailed vascular network of perforator of DIEA in Koreans. Methods: 24 fresh cadavers were studied. Among them, 15 were examined based on the plain X-ray examination for the distribution and location of perforator of DIEA. And 9 fresh cadavers were examined based on the 3-dimensional computed tomography(CT) study for the distance between ending point of perforator of DIEA and mother artery, the distance between most medial mother artery and midline, the distance between most lateral mother artery and midline, and the running type of perforators of DIEA. Results: Based on the plain X-ray examination, suitable(external diameter$${\geq_-}0.5mm$$) perforators of DIEA are located between the level of umbilicus and 8 cm below it. Based on the 3D-CT study, average distance between the ending point of perforator of DIEA and the mother artery is 30.26 mm on the left, 28.62 mm on the right, respectively. The average distance between most medial mother artery and midline is 17.13 mm on the left, 15.76 mm on the right, respectively. The average distance between most lateral mother artery and midline is 56.31 mm on the left, 50.90 mm on the right, respectively. The main running course of suitable perforators of DIEA is type a, which is a direct musculocutaneous perforator vessel from main vascular axis passing outward to join the subdermal plexus, directly. Conclusion: 3-dimensional computed tomography study as well as plain X-ray examination provided more accurate and detail informations about perforators of DIEA in Koreans. These informations will help us understand the detailed vascular anatomy and operation with ease and safe in the lower abdomen of Koreans.

Fishing investigation of vertical bottom longline fisheries in sea mount of central northern Pacific (북태평양 중부 해산어장에 있어서 저층 선주낙의 어획실태)

  • Oh, Taeg-Yun;Kim, Yeong-Seung;Cho, Sam-Kwang;Kim, In-Ok;Choi, Seok-Gwan;Koh, Jeong-Rack;Yang, Won-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.3
    • /
    • pp.188-198
    • /
    • 2005
  • This study was conducted to survey the catches of vertical bottom longline fisheries in the sea mount of central northern Pacific($30^{\circ}-42^{\circ}N$, $170^{\circ}-175^{\circ}E$), during the period of July 1 to August 25,2004 by commercial fishing vessel. The number of 57 test fishing was carried out in the central northern Pacific during 43 days and the total catches were 21,092.4kg as 19 fish species, CPUE/day and catches/day were 185 baskets and 490.5kg, respectively. Main fish species caught from the experimental fishing were Squalus mitsukurii (66.3%), Coelorhyrchus asperocephaius (11.7%) and Helicolenus avius (9.8%) and, average inside diameter for fish mouth was 4.0cm over. Catch ratio according to each fishing ground was the order of F, D, J, B and C. Catch ratio fur water depth was the order of 450-500m, 350-400m, 300-350m, 400-450m, 1000-1100m and 500-550m and, main species by water depth was Squalus mitsukurii for 300-400m, Etmopterus lucifer for 300-550m, Coelorhyrchus asperocephaius far 1,000m over. Catch ratio according to the kind of hooks was higher at the hook no.6 for Squalus mitsukurii and no. 5 for Etmopterus lucifer and, catch ratio by baits was higher at squid for Squalus mitsukurii, saury and eel for Helicolemus avius and saury for Etmopterus lucifer. Accordingly, it is thought that the extension of fishing hours is needed with the reduction of damage and loss for fishing gears during fishing operation.

Effects of Angiotensin II on Isolated Cardiac Muscle and Aortic Strips in Rabbit (안지오텐신 II의 적출심근 및 대동맥 평활근에 대한 작용기전)

  • Kim, Kyu-Chan;Kim, Ki-Whan;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.17 no.1
    • /
    • pp.45-54
    • /
    • 1983
  • Contractile responses of myocardium and vascular smooth muscle to angiotensin II were studied in isolated rabbit papillary muscles and aortic helical strips, with respect to the sensitivity and the mechanism of action. All experiments were performed in $HCO-_3\;-buffered Tyrode solution which was aerated with $3%\;CO_2-97%\;O_2$ and kept pH 7.35 at $35^{\circ}C$. Action potentials were measured by conventional microelectrode technique in the papillary muscles. Helical strips of vascular smooth muscle were prepared from the descending thoracic aorta of the rabbit. Angiotensin II elicited a positive inotropic effect in doses from $10^{-8}$ to $10^{-6}\;M$, and this effect was dose-dependent and characterized by a symmetrical increase of maximum dP/dt during contraction and relaxation phase. Slow responses (or slow action potentials) were induced by A. II $(10^{-6}\;M)$ in the papillary muscle hypopolarized by 27 mM $K^+$. These A. II-induced slow action potentials were eliminated by verapamil (2 mg/l), but not affected by propranolol $(10^{-5}\;M)$. In aortic helical strips, contractile force was increased dose-dependently in the range of $10^{-10}{\sim}10^{-7}\;M$ A. II. $ED_{50}$ in aorta was $3{\times}10^{-9}\;M$ A. II, whereas that in paillary muscle was $2.5{\times}10^{-7}\;M$ A. II. A. II contracted vascular smooth muscle in depolarizing concentration of $K^+$ (100 mM $K^+$), and also produced a sustained contraction even in the presence of verapamil and regitine. The results of this experiment suggest that the primarily important physiological role of A. II is the action on the blood vessel, and the positive inotropic effect of A. II in papillary muscle results from the increase of slow inward $Ca^{++}$ current, and that A. II-induced contraction of aorta is independent of transmembrane potential and associated with promoting bet transmembrane $Ca^{++}\;-influx$ and the mobilization of cellular $Ca^{++}$.

  • PDF

Photomixotrophic Growth of Solanum tuberosum L. in vitro with Addition and Omission of Organic Materials at Thee Initial Sucrose Levels in the Medium (세 수준의 자당이 첨가된 배지에서 유기물의 첨가 유무에 따른 Solanum tuberosum L.의 기내 광혼합영양생장)

  • Jeong, Byoung-Ryong;Yang, Chan-Suk;Kim, Gyeong-Hee;Park, Young-Hoon;Kozai, Toyoki
    • Journal of Bio-Environment Control
    • /
    • v.13 no.1
    • /
    • pp.51-55
    • /
    • 2004
  • The most commonly used inorganic nutrient compositions such as Murashige & Skoog medium have been optimized for heterotrophic growth. Therefore, they may not be optimal for photomixotrophic and photoautotrophic growth of plantlets. In photomixotrophic micropropagation, emdium sugar level is often lowered, while light and $CO_2$ levels in vessel are raised, and chlorophyllous explants are used to facilitate photosynthetic carbon acquisition. In a factorial experiment effect of addition (+) and omission(_) of organic materials (OM, 0.5 g ${\cdot}$ $m^{-3}$ each of thiamine, nicotinic acid and pyridoxine and 100 ${\cdot}$ $m^{-3}$ myo-inositiol) combined with three sucrose levels (0, 15, and 30 kg ${\cdot}$ $m^{-3}$) was tested on the growth of potato plantlets. Each of nodal cuttings with a leaf was cultured on 0.1${\times}$$10^{-4}m^{-3}$) MS agar ( 8 kg ${\cdot}$ $m^{-3}$) medium (pH 5.80 before autoclave) in glass test tubes (100 mm${\times}$25mm) capped with a sheet of transparent film with a 6 mm diameter gas permeable filter (5.1 air exchanges ${\cdot}$$h^{-1}$). Cultures were maintained in a room for 27 days at $23^{\circ}C$, 50% RH, 350-450${\mu}mol\;{\codt}\;mol^{-1}CO_2$, 16 h ${\cdot}$ $d^{-1}$ photoperiod at 13${\mu}mol\;{\codt}\;m\;{\codt}\;s^{-1}$ PPFD provided by white cool fluorescent lamps. Growth of potato plantlet in the +OM and -OM treatments were similar, while medium pH was 0.2 scale lower in the latter. Dry weight, % dry matter, and stem diameter enhanced, while shoot to root dry weight ratio, leaf area, chlorophyll concentration per gram dry weight, and medium pH decreased with increasing initial sucrose level. Interaction between OM and sucrose levels was observed in shoot length and medium pH. Results indicate that OM can be omitted from the medium without detrimental effect while addition of sucrose was beneficial for the photomixotrophic growth of potato plantlets under raised light and $CO_2$.

An Analytical Study on the Seismic Behavior and Safety of Vertical Hydrogen Storage Vessels Under the Earthquakes (지진 시 수직형 수소 저장용기의 거동 특성 분석 및 안전성에 관한 해석적 연구)

  • Sang-Moon Lee;Young-Jun Bae;Woo-Young Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.152-161
    • /
    • 2023
  • In general, large-capacity hydrogen storage vessels, typically in the form of vertical cylindrical vessels, are constructed using steel materials. These vessels are anchored to foundation slabs that are specially designed to suit the environmental conditions. This anchoring method involves pre-installed anchors on top of the concrete foundation slab. However, it's important to note that such a design can result in concentrated stresses at the anchoring points when external forces, such as seismic events, are at play. This may lead to potential structural damage due to anchor and concrete damage. For this reason, in this study, it selected an vertical hydrogen storage vessel based on site observations and created a 3D finite element model. Artificial seismic motions made following the procedures specified in ICC-ES AC 156, as well as domestic recorded earthquakes with a magnitude greater than 5.0, were applied to analyze the structural behavior and performance of the target structures. Conducting experiments on a structure built to actual scale would be ideal, but due to practical constraints, it proved challenging to execute. Therefore, it opted for an analytical approach to assess the safety of the target structure. Regarding the structural response characteristics, the acceleration induced by seismic motion was observed to amplify by approximately ten times compared to the input seismic motions. Additionally, there was a tendency for a decrease in amplification as the response acceleration was transmitted to the point where the centre of gravity is located. For the vulnerable components, specifically the sub-system (support columns and anchorages), the stress levels were found to satisfy the allowable stress criteria. However, the concrete's tensile strength exhibited only about a 5% margin of safety compared to the allowable stress. This indicates the need for mitigation strategies in addressing these concerns. Based on the research findings presented in this paper, it is anticipated that predictable load information for the design of storage vessels required for future shaking table tests will be provided.

A Study on the Dental Hygienists' Reactions to Noise When Occurred in Dental Clinic (치과병원에서 발생하는 소음에 대한 치과위생사의 반응)

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.453-459
    • /
    • 2009
  • The purposes of this research were to evaluate the relationships of between characteristics of noise and annoyance of dental hygienist by noise in dental clinic. To investigate the dental clinic workers' reactions to noise when occurred in dental clinic, the noise level test in dental clinic and questionnaire were taken. As a result of noise evaluation, It shows that the range of noise level was 67.7~78.3dB(A) and frequency was very high (more than 4KHz). It's seem to be begins occurrence of stamina-loss, contraction of peripheral blood vessel, decrease of adrenocortical hormones. Most of respondents were affected by noise: 67% of respondents were nervous about noise and the rest of respondents were bearable. Analysis by NR-curve showed that it was exceed the noise permit level in working space. As a result of correlation - test, the more exposed dental hygienist to noise, the more felt the unpleasantness and fatigue. It's hard to sufficient explanation to patients about the dental treatment. So it's thoughts that insufficient explanation will negative impact on the patients' satisfaction and increase competitiveness in dental clinics. To remedy a unpleasantness and fatigue of noise in dental hygienist, it's considered that making an offer the ear protection and choosing the low noise-vib. equipment and using the masking effect. Therefore, It can be provide a pleasant working environment with dental hygienist and It will have a great advantage to dental clinics to improve their competitiveness.

  • PDF

Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor (광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정)

  • Ko, J.I.;Jeong, I.C.;Lee, D.H.;Park, S.W.;Hwang, S.O.;Park, S.M.;Kim, G.Y.;Joo, H.S.;Yoon, H.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.