• Title/Summary/Keyword: 3D vessel

Search Result 351, Processing Time 0.029 seconds

Development of CANDU Pressure Tube Integrity Evaluation System;Its Application to Sharp Flaw and Blunt Notch (CANDU 압력관에 대한 건전성 평가시스템 개발;예리한 결함 및 둔한 노치에의 적용)

  • Gwak, Sang-Rok;Lee, Jun-Seong;Kim, Yeong-Jin;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.206-214
    • /
    • 2000
  • The pressure tube is a major component of the CANDU reactor, which supports nuclear fuel bundle and it's containment vessel. If a flaw is found during the periodic inspection from the pressure tube s. the integrity evaluation must be carried out. and the safety requirements must be satisfied for continued service. In order to complete the integrity evaluation, complicated and iterative calculation procedures are required. Besides, a lot of data and knowledge for the evaluation are required for the entire: integrity evaluation process. For this reason. an integrity evaluation system, which provides efficient of evaluation with the help of attached databases, was developed. The developed system was built on the basis of ASME Sec. XI and FFSG(Fitness For Service Guidelines for zirconium alloy pressure tubes in operating CANDU reactors) issued by the AECL, and covers the delayed hydride cracking(DHC). This system does not only provide various databases including the 3-D finite element analysis results on pressure tubes, inspection data and design specifications but also is compatible with other commercial database software. In order to verify the developed system, several case studies have been performed and the results were compared with those from AECL. A good agreement was observed between those two results.

A Study on the Slowly Varying Wave Drift Force Acting on a Semi-Submersible Platform in Waves (반잠수식 시추선에 작용하는 장주기 표류력에 관한 연구)

  • S.Y.,Hong;P.M.,Lee;D.C.,Hong
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.2
    • /
    • pp.49-63
    • /
    • 1989
  • Wave drift forces which are small in magnitudes compared to the first order wave exciting forces can cause very large motion of a vessel in waves. In this paper a theoretical and experimental analysis is made of the mean and slowly varying wave dirft forces on the semi-submersible platform. Theoretical calculations are performed by using near field method with three dimensional diffraction theory and model tests are carried out in regular and irregular waves with a 1/60 semi model. Test results are compared with theoretical calculations and the mooring spring effects in the test are discussed.

  • PDF

EVALUATION AND TEST OF A CRACK INITIATION FOR A 316 SS CYLINDRICAL Y-JUNCTION STRUCTURE IN A LIQUID METAL REACTOR

  • Park, Chang-Gyu;Kim, Jong-Bum;Lee, Jae-Han
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.293-300
    • /
    • 2006
  • A liquid metal reactor (LMR) operated at high temperatures is subjected to both cyclic mechanical loading and thermal loading; thus, creep-fatigue is a major concern to be addressed with regard to maintaining structural integrity. The Korea Advanced Liquid Metal Reactor (KALIMER), which has a normal operating temperature of $545^{\circ}C$ and a total service life time of 60 years, is composed of various cylindrical structures, such as the reactor vessel and the reactor baffle. This study focuses on the creepfatigue crack initiation for a cylindrical Y-junction structure made of 316 stainless steel (SS), which is subjected to cyclic axial tensile loading and thermal loading at a high-temperature hold time of $545^{\circ}C$. The evaluation of the considered creep-fatigue crack initiation was carried out utilizing the ${\sigma}_d$ approach of the RCC-MR A16 guide, which is the high-temperature defect assessment procedure. This procedure is based on the total accumulated strain during the service time. To confirm the evaluated result, a high-temperature creep-fatigue structural test was performed. The test model had a circumferential through wall defect at the center of the model. The defect front of the test model was investigated after the $100^{th}$ cycle of the testing by utilizing a metallurgical inspection technique with an optical microscope, after which the test result was compared with the evaluation result. This study shows how creep-fatigue crack initiation for a high-temperature structure can be predicted with conservatism per the RCC-MR A16 guide.

A Case of Metastatic breast Cancer and Reconstruction of Superior Vena Cava by Woven Dacron Y Graft (전이성 유암에서 Woven Dacrorl Y graft를 이용한 상대공정맥 재건술 -치험 III-)

  • 이원진;신호승
    • Journal of Chest Surgery
    • /
    • v.29 no.3
    • /
    • pp.346-349
    • /
    • 1996
  • This 32 year old female patient underwent left radical mastectomy due to ductal carcinoma on May 1990, and treated with FAM (5-fluorouracil, Adriamycin and Mitomycin C) regimen postoperatively. However, right cervical Iymph node enlargement and facial edema progressively developed since December 199). On April 1994, operation was performed, and findings were as followes; x4$\times$5$\times$7 to 1 : 1 $\times$ 1 cm sized multiple enlarged and hyperemic Iymph nodes were scatterred throughout submandibular area to the junction of superior vents cave and pericardium, and partially invaded both anterior segmental lobe, sternum and both distal tip of clavicles. After radical dissection of the nodes of neck and mediastinal nodes, and wedge resection of both anterior segments of lung, and partial resection of both clavicle tips and total sternum. The both innominate veins and superior vena cava were partially obstructed by invaded cancer SVC reconstruction was done with preclotted 10$\times$ 10$\times$ 18mm Y shap d woven Dacron graft, which was anastomosed to the point of the junction of subclavian vein and jugular vein after cross clamping both veins and 2cm above the pericardial junction with one arm clamp. After maintaining blood drainage to the SVC from the right side, left innominate vein was anastomosed with 4-0 Prolene continuous running suture. Bone cement was used for resected sternal portion and clavicular ends were fixed to postal portion with 18 Gauge wires. The patient was treated with radiation and chemotherapy after discharge, and there were no evidence of regrowing of the mass nor obstruction of the graft inspite of no antithrombotic therapy.

  • PDF

Migration Activity of Chicken Gonadal Primordial Germ Cells (gPGCs) and Post-transfer Localization of LacZ-transfected gPGCs in the Embryonic Gonads

  • Jeong, D.K.;Han, J.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.9
    • /
    • pp.1227-1231
    • /
    • 2002
  • A powerful tool for chicken transgenesis could be established by employing a germline chimera production through primordial germ cell transplantation. This study was conducted to examine whether foreign gene-transfected gonadal primordial germ cells (gPGCs) have a migration activity into the gonad after transfer to recipient embryos. In Experiment 1, gPGCs of Korean Ogol Chicken were retrieved from 5.5-day-old embryos and subsequently transferred to the dorsal aorta of 2.5-day-old White Leghorn embryos after being labeled with PKH26 fluorescent dye. To confirm migration activity after transplantation, recipient embryos were sacrificed and examined on 3 days after transfer. Sex determination was concomitantly undertaken to examine whether sex of recipient embryos could affect the migration activity of gPGCs. All of embryonic gonads examined showed positive signals with PKH26 fluorescence and W-chromosome specific band by polymerase chain reaction (PCR) was detected in male embryos when gPGCs with ZW chromosome were transferred to recipient embryos. In Experiment 2, retrieved gPGCs were transfected with LacZ gene-containing cytomegalovirus promoter ($pCMV{\beta}$) by electroporation and subsequently transferred to recipient embryos. LacZ gene expression was identified in the gonads of 6 or 10-day-old recipient embryos and hatched-chicks. A total of 20 embryos and 12 hatched-chicks were examined and 11 of them (10 embryos and one hatched chicken; 11/32=34.4%) expressed $\beta$-galactosidase, a marker substance of LacZ gene. The results of this study demonstrated that foreign gene-transfected gPGCs can migrate and settle down into the gonad after being transferred into the blood vessel of the recipient embryos. This established technique will contribute to developing a peer biotechnology for transgenic chicken.

UNDERWATER NOISE GENERATED BY FISHING GEAR -Stern trawl net- (어구에서 발생되는 소음 -트로올 어구-)

  • YOON Gab Dong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.4
    • /
    • pp.217-224
    • /
    • 1979
  • The main purpose of the present study is to measure the sound spectra of the underwater noises generated by moving trawl net. An underwater recording system was designed to detect underwater noise generated by moving trawl net. The acoustic analysis was made by a heterodyne analyzer (B & K 2010) and level recorder (B & K 2307). The noises generated by the trawl net are appreciably higher (about 10dB) than the background noise in the presence of the fishing vessel. The frequency distribution of underwater noise was DC-6,300 Hz and predominant frequency range was 100-200 Hz, and maximum sound pressure level was $137\;db(re\;1{\mu}Pa)$. Sound pressure level recorded at the ground rope was higher than that recorded at the head rope. The sound pressure level meosured in the course of hawling was higher than that measured in the course of towing. When tile net is being casted tile sound pressure level showed the lowest value.

  • PDF

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Compression of the Ulnar Nerve in the Ulnar Tunnel Caused by an Anomalous Pulsatile S-shaped Ulnar Artery (척골관에서 척골동맥의 주행 이상에 의한 척골신경의 압박)

  • Cheon, Nam Ju;Kim, Cheol Hann;Kang, Sang Gue;Tark, Min Seong
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.84-88
    • /
    • 2009
  • Purpose: Compression of the ulnar nerve in the ulnar tunnel is a relatively uncommon condition. Many authors have described several etiologies of ulnar nerve compression. We experienced two cases of ulnar nerve compression in the ulnar tunnel due to an anomalous pulsatile S - shaped ulnar artery. Methods: Case 1: A 51 - year - old man was referred with numbness and paroxysmal tingling sensation along the volar side of the ring and little fingers of his right hand for 6 months. When exploration, the ulnar artery was pulsatile S - shaped and was impinging on the ulnar nerve. To decompress the ulnar nerve, the tortuous ulnar artery was mobilized and translocated radially onto the adjacent fibrous tissue. Case 2: A 41 - year - old man was referred with tingling sensation on the 4 th, 5 th finger of the right hand for 4 months. Sensory nerve conduction velocities of the ulnar nerve was delayed. Preoperative 3D angio CT scan showed an anomalous S - shaped ulnar artery. Same operation was done. Results: The postoperative course was uneventful. After decompression, paroxysmal tingling sensation decreased to less than 1 minute per episode, occurring 1 - 2 times a day. After 4 months, they had no more episodes of numbness and tingling sensation. Examination demonstrated good sensation to pinprick and touch on the ulnar aspect of the hand. Conclusion: We report two cases of ulnar nerve compressive neuropathy that was caused by an anomalous pulsatile S - shaped ulnar artery in the ulnar tunnel. Although this is an unusual cause of ulnar nerve compression, the symptoms will not spontaneously resolve. The prompt relief of compressive neuropathic symptoms following the translocation of the impinging ulnar artery from the affected ulnar nerve onto adjacent tissue proved that the ulnar nerve compression is due to the anomalous vessel.

Identification of Whipping Response using Wavelet Cross-Correlation (웨이블릿 교차상관관계를 이용한 변형체 선박의 휘핑 응답 식별)

  • Kim, Yooil;Kim, Jung-Hyun;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.2
    • /
    • pp.122-129
    • /
    • 2014
  • Identification of the whipping response out of the combined wave-vibration response of a flexible sea going vessel is one of the most interesting research topic from ship designer's point of view. In order to achieve this goal, a novel methodology based on the wavelet cross-correlation technique was proposed in this paper. The cross-correlation of the wavelet power spectrum averaged across the frequency axis was introduced to check the similarity between the combined wave-vibration response and impulse response. The calculated cross-correlation of the wavelet power spectrum was normalized by the auto-correlation of the each spectrum with zero time lag, eventually providing the cross-correlation coefficient that stays between 0 and 1, precisely indicating the existence of the impulse response buried in the combined wave-vibration response. Additionally, the weight function was introduced while calculating the cross-correlation of the two spectrums in order to filter out the signal of lower frequency so that the accuracy of the similarity check becomes as high as possible. The validity of the proposed methodology was checked through the application to the artificially generated ideal combined wave-vibration signal, together with the more realistic signal obtained by running 3D hydroelasticity program WISH-Flex. The correspondence of the identified whipping instances between the results, one from the proposed method and the other from the calculated slamming modal force, was excellent.

Dynamic Analysis of AP1000 Shield Building Considering Fluid and Structure Interaction Effects

  • Xu, Qiang;Chen, Jianyun;Zhang, Chaobi;Li, Jing;Zhao, Chunfeng
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.246-258
    • /
    • 2016
  • The shield building of AP1000 was designed to protect the steel containment vessel of the nuclear reactor. Therefore, the safety and integrity must be ensured during the plant life in any conditions such as an earthquake. The aim of this paper is to study the effect of water in the water tank on the response of the AP1000 shield building when subjected to three-dimensional seismic ground acceleration. The smoothed particle hydrodynamics method (SPH) and finite element method (FEM) coupling method is used to numerically simulate the fluid and structure interaction (FSI) between water in the water tank and the AP1000 shield building. Then the grid convergence of FEM and SPH for the AP1000 shield building is analyzed. Next the modal analysis of the AP1000 shield building with various water levels (WLs) in the water tank is taken. Meanwhile, the pressure due to sloshing and oscillation of the water in the gravity drain water tank is studied. The influences of the height of water in the water tank on the time history of acceleration of the AP1000 shield building are discussed, as well as the distributions of amplification, acceleration, displacement, and stresses of the AP1000 shield building. Research on the relationship between the WLs in the water tank and the response spectrums of the structure are also taken. The results show that the high WL in the water tank can limit the vibration of the AP1000 shield building and can more efficiently dissipate the kinetic energy of the AP1000 shield building by fluid-structure interaction.