• Title/Summary/Keyword: 3D textiles

Search Result 603, Processing Time 0.025 seconds

The Effects of Scouring on Mechanical Properties and Appearance of Iyocell -NaOH Scouring vs. Enzymatic Scouring - (정련 방법에 의한 리오셀 섬유의 역학적 변화와 3D CAD SYSTEM에 의한 외관분석 -NaOH와 효소처리 중심으로-)

  • Park, Ji-Yang;Kim, Ju-Hea;Jeon, Dong-Won;Park, Young-Hwan
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.9_10 s.157
    • /
    • pp.1485-1493
    • /
    • 2006
  • This study was to investigate the effect of different scouring methods on mechanical properties and appearance of lyocell. Two different scouring methods were adopted for the study; one was the traditional scouring with alkali and the other was enzymatic scouring. Enzymatic scouring was carried with four different enzymes; C1 : Cellusoft L, C2 : Cellusoft UL, D1 : Denimax 992L, D2 : Denimax Acid XCL. The mechanical properties of scoured lyocell were measured using KES-FB. The appearance of scoured samples was analyzed by 3D CAD SYSTEM of i-Designer. While the untreated fabric showed the best linearity because it is stiff, alkali treated samples showed the worst dimensional stability and distorted easily. Enzyme treated samples, especially C1 treated samples showed the best dimensional stability. In addition, enzyme treated samples showed low bending rigidity compared to the alkali treated samples. It means that the enzyme treated samples are more flexible than alkali treated samples. However, the smoothness of the sample's surface treated by either of methods did not show much difference. From the study, it was suggested that the enzymatic scouring for lyocell could help to gain natural silhouette.

Characteristic Evaluation of Impact Absorption Materials for the Development of Fall Impact Protective Pants (낙상 보호 팬츠개발을 위한 충격흡수 소재특성 평가)

  • Park, Jung Hyun;Lee, Jin Suk;Lee, Jeong Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.3
    • /
    • pp.495-505
    • /
    • 2016
  • This study explores and selects an appropriate material that considers light and soft physical properties as well as activity for impact absorption pads that can be used to develop practical impact protective clothes worn during daily life by the elderly to reduce the impact of falls. Physical properties, impact absorption performance, and compression characteristics were evaluated on 5 types of foam, 2 types of 3D spacer fabric, and 3 types of polymer gel to select a material appropriate for the pad to be inserted into impact protective clothes. The evaluation of the physical properties showed that 3D spacer fabrics had lower density compared to other materials and polymer gels had the highest density. The elongation percentage was higher in foams than 3D spacer fabrics and EPDM foam had the highest elongation percentage. The impact absorption performance of honeycomb polymer gel was better than foams and 3D spacer fabrics. As a result of looking into compression energy and compression characteristics of materials, 'CR foam A' was found to absorb the largest amount of compression energy, 24.1%, among foams and polymer gels. A high energy absorption rate of 50.0% (or above) was indicated by 3D spacer fabrics; however, foams and polymer gels showed a progressive deformation of energy compression / recovery curve with 3D spacer fabrics that showed drastic deformation. Based on characteristics of materials, 'CR foam C' and EPDM with relatively high absorption performance can be used as protective pad materials among foams. Among polymer gels, 2 open-type polymer gels that have relatively low impact protective performance but a relatively lighter weight on human body (compared to closed-type) are considered appropriate protective pad materials.

A Comparative Analysis of the Different between CLO 3D Avatar Sizing and Actual Body Measurement Shapes (CLO 3D 아바타 사이징과 실제인체간의 치수 및 형태 차이 비교 분석)

  • Lee, Min-Jeong;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.16 no.4
    • /
    • pp.137-151
    • /
    • 2012
  • This study aims to use the avatar sizing system of the 3D apparel CAD program instead of the existing 3D body scanners, and to commercialize 3D personal avatars. Towards these ends, the study examined a difference between a 3D avatar and actual body was determined to verify the 3D avatar sizing system. For the experiment, three subjects were selected, were measured as they were, and were made to undergo 3D body scanning and photographing. Then, using avatar sizing system on the 3D apparel CAD program, three types of virtual bodies, namely 3D avatars. The 3D avatar and actual body measurements were compared, and 3D avatars and 3D body-scanned shapes were likewise compared. As a result, the three types of actual bodies and their 3D avatars that were created based on the sizing system of the 3D apparel CAD program were overall similar. but, the thin body-YY type and the normal body-A type were different from their avatars. In the case of type B, who had a bulging abdomen, the 3D avatar was bigger than the actual body as measured. Also, in all body shapes, the girths around the chest, waist and abdomen were produced with exaggerated muscular amounts compared to their actual muscular amounts.

UVB Photosynthesis of Vit, D3 and Fabrics (Part ll) - The animal study - (자외선에 의한 비타민 $D_3$ 합성과 직물(제2보) -동물 실험을 통하여 -)

  • Kim, Jeong-Hyeon;An, Ryeong-Mi;Song, Myeong-Gyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.5
    • /
    • pp.646-653
    • /
    • 1998
  • Because there is a great concern' today about the damaging effect of chronic exposure to sunlight the use of sunscreen providing the photoprotection effect against ultraviolet (UV) was widely increased. As a result of common use of level of photosynthetic Vit. D3 in human skin decreased these days. In our experiment the animals covered with fabrics with 50% (fabric B) and 100% (fabric A) protection rate against ultraviolet B (UVB) were used to measure serum 25(OH)D3, ALP, total clacium and phosphorus. Vitamin D deficiency diet group had no effect on concentration of serum phosphorus. But the concentrations of serum 25(OH)D9 and total calcium were more decreased in vitamin D deficiency diet rats than in normal diet rats. Alkaline phosphatase activity in sunlight irradiated groups covered with 50% (fabric B) and 100% (fabric A) WB protection fabrics was more significantly decreased than vitamin D deficiency diet group. In conclusion, sunlight irradiateted groups were compared to effective to protect born disease due to the Vit. D deficeincy group.

  • PDF

Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern - (3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 -)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.4
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

A Comprehensive Analysis of 3D Body Scanning vs. Manual Measurements in a Large-Scale Anthropometric Survey -Insights from the 8th Size Korea Project- (대규모 인체치수조사 사업에서 3차원 측정치와 직접측정치의 차이 분석 -제8차 사이즈코리아 사업을 중심으로-)

  • Sunmi Park
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.2
    • /
    • pp.233-253
    • /
    • 2024
  • This study analyzed differences between three-dimensional (3D) body scanning and manual measurements, aiming to assess whether 3D scanning can replace traditional anthropometric tools, such as tape measures and calipers. Data from 4,478 participants in the 8th Size Korea Project were analyzed, covering 43 measurement items. Since Given that the 3D and manual measurements were performed on the same subjects in the 8th Size Korea Project, it was possible to determine the correlation more accurately between the two measurement methods more accurately. Using Applying ISO 20685-1(2018) standards, 15 out of the 43 items fell within allowable error limits. When classified into six types, "small circumferences" and "segment lengths" showed averages of 3.35 mm and 3.10 mm, respectively, within acceptable range. "Body heights" and "body depths" slightly exceeded the limit, with averages of 5.28 mm and 6.58 mm. "Body widths" and "large circumferences" surpassed the limit, with means of 16.77 mm and 16.18 mm. The study offers an objective basis to for validate validating 3D measurements' measurements' reliability and accuracy, addressing various industries' needs for information on the human body's dimensions information.

Improvement of Cross Sectional Distance Measurement Method of 3D Human Body (3차원 인체 형상의 공극거리 측정 방법 효율성 향상을 위한 연구)

  • Kim, Min-Kyoung;Nam, Yun-Ja;Han, Hyun-Sook;Choi, Young-Lim
    • Fashion & Textile Research Journal
    • /
    • v.13 no.6
    • /
    • pp.966-971
    • /
    • 2011
  • This study is designed to develop programs that analyze the distance of clothes from human skin and cross-sectional body figures based on 3D human body scan data, and to verify accuracy and efficiency of the program so that it can be used for clothing fit evaluation and 3D human body research. The auto cross-sectional imaging program was developed by using Visual C++ and OpenGL, and the 3D human body scan data were adopted to measure the space between skin and clothing. The space measurements were obtained by two widely used programs, RapidForm and AutoCAD, and a program devised by the researchers of this study. Measuring time and space measurements from different programs were compared in order to verify accuracy and efficiency of the newly-devised program. As a result, no significant difference was found in the measurements. However, the required time to measure one cross section was different within the significance level of 0.05, and the differences become more remarkable as the number of measuring and the angle of space between skin and clothing increase. Therefore, the program developed by this study is expected to be useful for research on body shapes and fit evaluation based on 3D human body scan data in the fashion field.

Design and Evaluation of a Knee Protector using a 3D Printing Pad (3D 프린팅 패드를 활용한 무릎 보호대의 설계 및 평가)

  • Xi Yu Li;Jung Hyun Park;Jeong Ran Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.2
    • /
    • pp.221-229
    • /
    • 2023
  • This study aims to develop knee protectors that provide high safety and fitness, while incorporating a motion-adaptable 3D-printed pad. These protectors were evaluated by individuals who experience knee discomfort or pain. The results are as follows. First, the 3Dprinted pad design of a hexagonal mesh structure, which is modeled for excellent appearance and knee movement. Each unit of the mesh has a outer layer of 2mm thick, a spacer layer of 1 mm in diameter, and is connected by a 1.5 mm bridge. The bridge was extended up to 1.2 cm. Second, the knee brace was designed in three types - cylinder, strap, and combination by Universal design. Impact protection measurements of the three knee protectors demonstrated roughly 80% reduction in impact. Third, based on usability evaluation, cylinder type protectors have the highest ratings in most areas, primarily because of their ease of use. The strap type protector received positive reviews in terms of appearance and care, and the combination type provided stable knee protection. This study demonstrated the potential industrial application of 3D printing technology by designing and evaluating protective products for the human body. The results of this study are expected to aid knee protector manufacturers in developing practical products and promoting the development of protective equipment for other body parts or purposes.

A study on the Analysis of 3D Scanning of Knit Stitches and Modeling System - Jersey, Rib, and Cable Stitches -

  • Choi, Kyoung-Me;Kim, Jong-Jun;Song, Na-Gun
    • Journal of Fashion Business
    • /
    • v.16 no.3
    • /
    • pp.125-135
    • /
    • 2012
  • Since knitted textile products mostly do not require long span of time from the conception to the final products, they have lead the fashion trends during the recent decades. Developments in the textile engineering industries, and computer software and hardware industries have made the 3D virtual clothing software system easily accessible by the fashion/textile industry personnel. The simulated models of apparel products using the state-of-the-art virtual clothing systems are, however, not the replica of real-world garments. Moreover, the garments do not maintain fixed shapes during wearing. Deformations at low external stress lead to difficulties in predicting the behavior of the knitted garments. Therefore, there is a need to compare the differences in appearances, textures, or other related properties between simulated fabrics and actual fabrics. Three knit stitches including jersey, rib, and cable stitches are examined in this study. The differences between fluffy thick yarns and thin yarns are also compared using 3D scanning and surface reconstruction. Obtained three-dimensional data regarding the reconstructed knit specimens would help to build a data base for estimating the behavior of the 3D models of the knitted garments.