• Title/Summary/Keyword: 3D posture

Search Result 238, Processing Time 0.021 seconds

Correlation between Craniovertebral Angle and Body Mass Index in Middle Age for Improvement of Life Care (라이프케어 증진을 위한 중년층에서 두개척추각과 신체지수의 상관관계)

  • Moon, Ok-Kon;Choi, Tae-Seok;Choi, Wan-Seok
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.231-236
    • /
    • 2020
  • The purpose of this study was to investigate the correlation between craniovertebral angle(CVA), age, and body mass index(BMI) in middle-aged people in their 40s and 50s. The forward head posture(FHP) was measured using a posture measuring device using a 3D sensor for 456 healthy men and women. As a result of the study, the middle-aged CVA had a high level of negative correlation with age (r=-.937; p<.01) and a very low level of positive correlation with BMI (r=.071). CVA of middle-aged men had a high negative correlation with age (r=-.932; p<.01) and a very low positive correlation with BMI. There was a correlation (r=.056), whereas, for middle-aged women, there was a high level of negative correlation (r=.939, p<.01) only with age, but had a weak (low level of negative) correlation with BMI. This study suggests that CVA has a significant negative correlation with age in both males and females however, has a weak relationship with BMI.

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.

Comparison of Avatar Posture Formation According to 3D Virtual Garment Modeling Programs -Focusing on Cycling Movements of High-School Male Cyclist-

  • Park, Hyunjeong;Do, Wolhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.965-977
    • /
    • 2021
  • The study aimed to analyze the functional differences in 3D virtual garment programs and compare body scan data with the corresponding 3D virtual models. We selected 3D virtual garment programs, formed virtual models in a representative size for high-school male cyclists, and analyzed them using the Design-X program. The results were as follows. In the 3D virtual garment programs, the anthropometric items for virtual model forming differed significantly from the standard anthropometric items suggested by Size Korea. Comparing the lower body scan data and virtual models formed by the 3D virtual garment programs, the biggest difference was in the shapes of the waist and hips, i.e., the flatness values of the waist and hips were different for each program in the cross-section view. In the lower body, a data-input-based program was needed for changing the exact measurement position of the waist circumference and hips' shape in detail. If a 3D virtual garment program provides functions for the virtual model's joint angle input and free motion transformation, it is expected to be widely used in the sportswear industry.

Posture Stabilization Algorithm of A Small Unmanned Ground Vehicle for Turnover Prevention (전복 방지를 위한 소형 무인주행로봇의 자세 안정화 알고리즘)

  • Koh, Doo-Yeol;Kim, Young-Kook;Lee, Sang-Hoon;Jee, Tae-Young;Kim, Kyung-Soo;Kim, Soo-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.965-973
    • /
    • 2011
  • Small unmanned ground vehicles(SUGVs) are typically operational on unstructured environments such as crashed building, mountain area, caves, and so on. On those terrains, driving control can suffer from the unexpected ground disturbances which occasionally lead turnover situation. In this paper, we have proposed an algorithm which sustains driving stability of a SUGV as preventing from turnover. The algorithm exploits potential field method in order to determine the stability of the robot. Then, the flipper and manipulator posture of the SUGV is optimized from local optimization algorithm known as gradient descent method. The proposed algorithm is verified using 3D dynamic simulation, and results showed that the proposed algorithm contributes to driving stability of SUGV.

Industrial Bin-Picking Applications Using Active 3D Vision System (능동 3D비전을 이용한 산업용 로봇의 빈-피킹 공정기술)

  • Tae-Seok Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_2
    • /
    • pp.249-254
    • /
    • 2023
  • The use of robots in automated factories requires accurate bin-picking to ensure that objects are correctly identified and selected. In the case of atypical objects with multiple reflections from their surfaces, this is a challenging task. In this paper, we developed a random 3D bin picking system by integrating the low-cost vision system with the robotics system. The vision system identifies the position and posture of candidate parts, then the robot system validates if one of the candidate parts is pickable; if a part is identified as pickable, then the robot will pick up this part and place it accurately in the right location.

Foot Type Classification of Korean Male Farmers for Ergonomic Work Shoes Design

  • Kim, Dohee;Hwang, Kyoung Suk;Lee, Kyung Suk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.773-783
    • /
    • 2012
  • Objective: The aim of this study is to identify foot shapes of Korean male farmers by classifying their foot types using 3D scan data and analyzing the characteristics of each type. Background: The increasing demands for anthropometric information for the design of machinery and personal protective equipment to prevent occupational injuries has necessitated an understanding of the anthropometric differences to be found among occupations. Static stooped posture and squatting posture are so common in Korean farmers that anthropometric deformation in foot especially seems to occur easily. Method: 366 Korean male farmers volunteered for this study from 16 different farming villages nationwide from 2009 to 2011. Subjects were categorized into 4 age groups from 40s to 70s. Their right feet were measured by using 3D foot scanner, the anthropometric dimensions were composed of 40 items. Results: The 8 major factors affecting the foot shapes were extracted. From these factors the foot shape of Korean male farmers was classified into 3 Foot types. Foot type 1 showed severe deformation in toe 1, type 2 had a narrow shape and type 3 had a wider width for its length. Conclusion: There were some differences in foot shape and types between farmers and the public. The most characteristic foot type in Korean male farmers was type 3. Application: The results of identifying foot shapes of Korean male farmers might provide the useful information for designing ergonomic farm work shoes.

Human Legs Motion Estimation by using a Single Camera and a Planar Mirror (단일 카메라와 평면거울을 이용한 하지 운동 자세 추정)

  • Lee, Seok-Jun;Lee, Sung-Soo;Kang, Sun-Ho;Jung, Soon-Ki
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1131-1135
    • /
    • 2010
  • This paper presents a method to capture the posture of the human lower-limbs on the 3D space by using a single camera and a planar mirror. The system estimates the pose of the camera facing the mirror by using four coplanar IR markers attached on the planar mirror. After that, the training space is set up based on the relationship between the mirror and the camera. When a patient steps on the weight board, the system obtains relative position between patients' feet. The markers are attached on the sides of both legs, so that some markers are invisible from the camera due to the self-occlusion. The reflections of the markers on the mirror can partially resolve the above problem with a single camera system. The 3D positions of the markers are estimated by using the geometric information of the camera on the training space. Finally the system estimates and visualizes the posture and motion of the both legs based on the 3D marker positions.

Evaluation of Setup Usefulness of CBCT using Rando Phantom (인체 팬텀(Rando Phantom)을 이용한 CBCT의 Setup 유용성 평가)

  • Jang, Eun-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.7
    • /
    • pp.234-238
    • /
    • 2011
  • This paper will evaluate the usefulness of 3D target of CBCT by comparing human body's posture and position when simulated treatment is being carried out as well as human phantom posture and position using CBCT which is applying OBI. From the Rando Phantom which is located in the datum point moved in parallel and rotationary direction using CBCT. Then the mean and standard deviation difference on images location difference that are acquired were compared with real the Rando Phantom' moved distance. To make a plan of simulated treatment with the same procedure of real radiation therapy, we are going to setup the Rando Phantom. With an assumption that the position is set in accurate place, we measured the setup errors accroding to the change of the translation and rotation. Tests are repeated 10 times to get the standard deviation of the error values. The variability in couch shift after positioning equivalent to average residual error showed lateral $0.2{\pm}0.2$mm, longitudinal $0.4{\pm}0.3$mm, vertical $-0.4{\pm}0.1$mm. The average rotation erroes target localization after simulated $0.4{\pm}0.2$ mm, $0.3{\pm}0.3$ mm, and $0.3{\pm}0.4$ mm. The detection error by rotation is $0{\sim}0.6^{\circ}$ CBCT 3D/3D matching using the Rando Phantom minimized the errors by realizing accurate matching during simulated treatment and patient caring.

Development of Men Slacks Pattern Using 3D Scan Data (3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계)

  • Sohn, Boo-Hyun
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

Posture Estimation Method for a Cylindrical Object (원기둥형 물체의 자세 인식 방법)

  • Jeong, Kyu-Won
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.234-239
    • /
    • 2003
  • A cylindrical shape object is widely used as a mechanical part and a water pipe or an oil pipeline which are of cylindrical shape are widely used in the infrastructure. In order to handling such objects automatically using a robot, the posture i.e. orientation in 3D space should be recognized. However, since there is no edge or vertex in the pipe, it is very difficult task for the robot. In this paper in order to guide the robot, two kind of algorithms which find the axis using the measured range data from the robot to the object surface are to be developed. The algorithms are verified using both the simulated range data and the measured one.

  • PDF