• Title/Summary/Keyword: 3D posture

Search Result 237, Processing Time 0.023 seconds

A Study on the Significance of the Colloidal Radiogold Disappearance Rate as a Simple Clinical Liver Function Test (임상간기능검사법(臨床肝機能檢査法)으로서의 교질형방사성금(膠質形放射性金)의 혈중소실율(血中消失率)의 의의(意義)에 관(關)한 연구(硏究))

  • Hong, Chang-Gi
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 1969
  • Liver functions in diffuse parenchymal liver disease such as cirrhosis of the liver depend largely on the effective hepatic blood flow rather than on the individual cell functions. Clinical methods of measuring the hepatic blood flow were developed recently by the application of colloidal disappearance rate. In order to correlate the radiogold disappearance rate to conventional biochemical liver function tests, 21 normal subjects and 80 cases of cirrhosis of the liver were studied with both methods. The results are summarized as following: 1. The validity of external counting method to measure the blood disappearance rate of colloidal radiogold was confirmed by in vitro counting of the serial blood samples. 2. The blood disappearance rate of collidal radiogold was essentially the same. as the liver uptake rate of colloidal radiogold in normal and cirrhotic subjects with various degrees of functional disturbance. And it seemed there was no serious extrahepatic removal of the colloidal radiogold. 3. The disappearance rate of colloidal radiogold was not significantly changed by the posture change, but was enhanced by ingestion of 500 ml of water. 4. The disappearance rate of colloidal radiogold was not influenced by single dose of Telepaque, while BSP retention was increased after Telepaque. 5. The mean disappearance half time of colloidal radiogold in normal subjects was $2.49{\pm}0.391$(S.D.) minutes. The mean normal disappearance rate constant (K value) was $0.285{\pm}0.0428$(S.D.)/minute. 6. The colloidal radiogold disappearance half time was abnormally prolonged (over 3.2 min.) in $87.7{\pm}3.68$(S.D.) % of cirrhotic subjects. 7. In patients of liver cirrhosis the blood disappearance rate of colloidal radiogold correlated well to serum albumin and globulin levels and BSP retention which were considered to reflect functions of hepatic parenchymal cells. There was, however, no correlation between colloidal disappearance rate and thymol turbidity test, serum glutamic pyruvic transaminase, and serm alkaline phosphatase activities. The latters were considered to be associated with the activity of liver disease.

  • PDF

Adolescent Girls' Bodice Pattern Fit Using the 3-Dimensional Virtual Clothing System (3차원 가상 착의 시스템을 이용한 여자 청소년용 길 원형 맞음새 연구)

  • Kim, Dohkyung;Chun, Jongsuk
    • Human Ecology Research
    • /
    • v.54 no.3
    • /
    • pp.279-292
    • /
    • 2016
  • This research predicted the fit of the basic bodice patterns worn on adolescent girls' 3-dimensional scanned bodies. Six 3-dimensional scanned bodies were selected from the sixth Size Korea data. Each of them had good body posture and represented one of the three garment sizes: 79-160, 82-160, and 85-160. Experimental basic bodice patterns were drafted by three basic bodice pattern making methods. The fit of the basic bodice pattern was analyzed by the CLO 3D virtual clothing system. The results showed that the experimental basic bodice patterns did not fit well at the neck, shoulder, and back for adolescent girls. The fit of the basic bodice patterns varied by pattern making method or size. The basic bodice pattern A with the waist darts ending above the breast line showed the best fit among the three different types of experimental pattern. Among the three sizes 79-160, 82-160, and 85-120, size 79-160 basic bodice pattern showed the worst fit for adolescent girls. The results show that the placement and size of the bodice darts affect the basic bodice pattern fit. The basic bodice pattern making method of size 79-160 for adolescent girls should be studied in a future study.

Investigation of image preprocessing and face covering influences on motion recognition by a 2D human pose estimation algorithm (모션 인식을 위한 2D 자세 추정 알고리듬의 이미지 전처리 및 얼굴 가림에 대한 영향도 분석)

  • Noh, Eunsol;Yi, Sarang;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.285-291
    • /
    • 2020
  • In manufacturing, humans are being replaced with robots, but expert skills remain difficult to convert to data, making them difficult to apply to industrial robots. One method is by visual motion recognition, but physical features may be judged differently depending on the image data. This study aimed to improve the accuracy of vision methods for estimating the posture of humans. Three OpenPose vision models were applied: MPII, COCO, and COCO+foot. To identify the effects of face-covering accessories and image preprocessing on the Convolutional Neural Network (CNN) structure, the presence/non-presence of accessories, image size, and filtering were set as the parameters affecting the identification of a human's posture. For each parameter, image data were applied to the three models, and the errors between the actual and predicted values, as well as the percentage correct keypoints (PCK), were calculated. The COCO+foot model showed the lowest sensitivity to all three parameters. A <50% (from 3024×4032 to 1512×2016 pixels) reduction in image size was considered acceptable. Emboss filtering, in combination with MPII, provided the best results (reduced error of <60 pixels).

Three-dimensional human activity recognition by forming a movement polygon using posture skeletal data from depth sensor

  • Vishwakarma, Dinesh Kumar;Jain, Konark
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.286-299
    • /
    • 2022
  • Human activity recognition in real time is a challenging task. Recently, a plethora of studies has been proposed using deep learning architectures. The implementation of these architectures requires the high computing power of the machine and a massive database. However, handcrafted features-based machine learning models need less computing power and very accurate where features are effectively extracted. In this study, we propose a handcrafted model based on three-dimensional sequential skeleton data. The human body skeleton movement over a frame is computed through joint positions in a frame. The joints of these skeletal frames are projected into two-dimensional space, forming a "movement polygon." These polygons are further transformed into a one-dimensional space by computing amplitudes at different angles from the centroid of polygons. The feature vector is formed by the sampling of these amplitudes at different angles. The performance of the algorithm is evaluated using a support vector machine on four public datasets: MSR Action3D, Berkeley MHAD, TST Fall Detection, and NTU-RGB+D, and the highest accuracies achieved on these datasets are 94.13%, 93.34%, 95.7%, and 86.8%, respectively. These accuracies are compared with similar state-of-the-art and show superior performance.

Analysis of Plantar Foot Pressure according to Insole Types during Treadmill Gait (트레드밀 보행시 인솔 형태 변화에 따른 족저압력 분석)

  • Woo, Jung-Hwi;Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin;Bae, Kang-Ho;Han, Dong-Wook;Park, Sang-Muk;Bae, Jin-Woo
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.113-122
    • /
    • 2015
  • Objective : The purpose of this study was to analyze the foot-pressure distribution of 2D(2 dimensional form) & 3D(3 dimensional form; a customized arch-fit for posture correction) insoles for assessing their biomechanical functionality. Background : Recently there has been increased interest in both foot health and foot pain patients. Analysis of the plantar pressure was often used to solve the problems of the foot displayed by such people as rheumatoid arthritis patients. Method : Subjects who participated in this study were 17 female university students who had no previous injury experience in lower limbs and a normal gait pattern. The shoe size of all subjects was 240 mm. Two models of insoles of 2D(typical flat insole - 2 dimensional form) and 3D(special production - 3 dimensional form) were selected for the test. Using the Pedar-X system and Pedar-X insoles, 4.0 km/h of walking speed, and a compilation of 50 steps walking stages were used to analyze foot-pressure distribution. Results : Results of the foot-pressure distribution and biomechanical functionality on each insole were as follows; analyses of mean plantar pressure, maximum plantar pressure, maximum vertical GRF, and plantar pressure curve shape all showed overall low plantar pressure and GRF. Conclusion : This can be evaluated as an excellent insole for low levels on the plantar pressure and GRF. Therefore, it is possible to conclude that according to this analysis the 3D Customized Arch-fit Insole was better than 2D insole on the basis of these criteria.

A Basic Study of ROV System Design for Underwater Structure Inspection (수중 구조물 검사를 위한 ROV 시스템 설계 연구)

  • Ryu, Jedoo;Nam, Keonseok;Ha, Kyoungnam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.463-471
    • /
    • 2020
  • Recently, various tries to apply ROV (Remotely Operated Vehicle) into underwater are being developed. However, due to underwater environment uniqueness, the additional problem must be taken into account when designing an ROV for the inspection of the underwater structure. This is because a GPS-based information method cannot be applied, and the obtainable image is also dependent on the turbidity. Also, it is necessary to be able to satisfy waterproof and operating speeds in consideration of most practical application environments. This paper describes the design results of the ROV system for underwater structure inspection considering the above problems. The designed system applied INS / DVL for location recognition and was configured to support 3D mapping and stereo camera-based image information using sonar depending on visibility. To satisfy the waterproof, a pressure vessel using a composite material was applied. And over-actuated system using eight thrusters to maintain a stable posture and operating speed was applied also. The designed system was verified by structural analysis and flow analysis also.

Reliability of Lateral Deviation Measurement in the Hyoid Bone With Center Point and Lateral Motion Tests

  • Min, Hye-jin;Yoon, Tae-lim
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.76-83
    • /
    • 2019
  • Background: The hyoid bone is the only non-jointed structure among the skeletal tissues of the head and neck region, and its movement and posture depend on the attached muscle, ligament, and fascia. The location of the hyoid bone is important for airway maintenance, vocalization, chewing, swallowing, breathing, and head and scapular position. In general, the location of the hyoid bone is measured using radiographs and 3D computed tomography, and no studies have reported on clinical measurement methods. Objects: This study was performed to suggest clinical measurement methods for lateral deviation of the hyoid bone and to evaluate their reliability. Methods: In this study, 24 healthy volunteers (12 males, 12 females) in Cheongju-si participated. Two examiners performed the center point test and lateral motion test twice each to measure the lateral displacement of the hyoid bone. The reliability of the center point test was analyzed using intra-class correlation coefficients (ICC), and the reliability of the lateral motion test was analyzed using Cohen's kappa coefficient. Results: The intra-rater reliability of the center point test was good, and the inter-rater reliability was moderate. The intra- and inter-rater reliability of the lateral motion test showed substantial reliability. Conclusion: Based on these results, the center point test and the lateral motion test can be used as an alternative methods of the measurement of lateral deviation of the hyoid bone for people who have musculoskeletal disorders of the head, neck, and scapula.

Posture Stabilization Control of QuadCopter Using Sensor Fusion and Modified PID Control (진동에 강인한 센서 융합 필터와 개선된 PID 제어 방식을 이용한 쿼드콥터의 자세 제어)

  • Cho, Youngwan;Kim, Hyun-Soo
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.376-382
    • /
    • 2014
  • In this paper, we propose a advanced attitude PID controller and sensor fusion method robust to the vibration of the quadcopter unmanned air vehicle using four BLDC motors. When the gyro sensor and acceleration sensor are fused, a complementary filter is designed to ignore the vibrations generated by the motors and to complement the drawbacks. As a result, we obtain accurate results than using each sensor. Also, it is possible to obtain a low delay results in robust to vibration than the low-pass filter or moving average filter, which is generally used for quadcopter. And we improved D controller, which have being used for attitude control of quadcopter, to quadcopter using gyro sensor. it was confirmed that the attitude is stabilized and error is reduced By using gyro sensor output instead of variation of estimated angle in D control.

The Analysis of Kinematic Difference in Glide and Delivery Phase for the High School Male Shot Putter's Records classified by Year (남자 고등부 포환던지기 선수들의 연도 별 기록에 따른 글라이드와 딜리버리 국면의 운동학적 차이)

  • Park, Jae-Myoung;Chang, Jae-Kwan;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.295-306
    • /
    • 2013
  • The purpose of this study was to provide high school male shot putters training methods of gliding and delivery motion through comparative analysis of kinematic characteristics. To accomplish this purpose, three dimensional motion analysis was performed for the subjects(PKC, KKH, YDL) who participated in high school male shot putter competition on 92nd (2011), 93rd (2013) National Sports Festival. The subjects were filmed by four Sony HXR-MC2000 video cameras with 60 fields/s. The three-dimensional kinematic data of the glide, conversion and delivery phase were obtained by Kwon3d 3.1 version. The data of the shoulder rotational angles and projection angles were calculated with Matlab R2009a. The following conclusions had been made. With the analysis of the gliding and stance length ratio, the gliding length was shorter at the TG than the SG with short-long technique but the gliding and stance length ratio was 46.8:53.2% respectively. The deviation of the shots trajectory from APSS(Athlete-plus-shot-system) revealed that the PKC showed similar to "n-a-b-c-I" of skilled S-shape type, KKH and YDL showed "n-a-d-f-I'" of unskilled type. Furthermore, they showed smaller radial distance from the central axis of the APSS and the shots were away from the linear trajectory. From this characteristics, The PKC who performed more TG than SG had shorter glide with S-shape of APSS(skilled type) showed the better record than others with technical skill. But KKH and YDL had bigger glide ratio with "n-a-d-f-I'" of unskilled type and improved their records with technical factor. The projection factor had an effect on the record directly. Because PKC maintained more lower glide and transition posture with momentum transfer through COG's rapid horizontal velocity respectively the subject possessed the characteristics of high horizontal and vertical velocity with large turning radius from shot putter to APSS.

A Study on the Usefulness of an Ankle Joint Examination Assistive Device using a 3D Printing (3D 프린터를 이용한 발목관절 검사 보조기구의 유용성연구)

  • Dong-Hee Hong;Eun-hye Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1099-1108
    • /
    • 2023
  • The mortise view radiography procedure is an ankle joint examination and observes the presence of trauma, sprain, or dislocation suspected in the ankle joint. The auxiliary equipment used during the mortise view radiography procedure can generate artifacts in the radiograph images and is not diverse enough to be custom-made for each patient; not cost-efficient. The purpose of this study is to create a custom assistive device to support mortise view radiography procedure. This study utilized 3D printing technology to create the mortise view radiography procedure assistive device (ShinHan Device; SHD). The lengths of the tibiotalar joint (TTJ), talar calcaneal joint (TCJ), and medial joint (MJ) were measured and evaluated by five researchers using both SHD and the prototype Hologic tool. The mean ranges were found to be 39.42-39.47 mm for TTJ, 31.41-31.57 mm for TCJ, and 21.21-21.23 mm for MJ while using SHD device. On the other hand, the measurements showed mean ranges of 39.73-39.79 mm for TTJ, 31.46-31.50 mm for TCJ, and 21.31-21.35 mm for MJ while using the Hologic tool. Based on this study results, the error ranges at all positions decreased by 24% for TTJ, 17% for TCJ, and 36% for MJ when using SHD device compared to the Hologic tool. Moreover, when SHD was used, it allowed for a highly reproducible examination posture (ICC = 0.99), and it enabled the acquisition of radiograph images without artifacts, which were present in the Hologic tool.