• Title/Summary/Keyword: 3D positioning accuracy

Search Result 160, Processing Time 0.024 seconds

The Digital Image Acquisition of High-resolution by Enhancing the Multiple Images (다중영상 강화에 의한 고해상도 수치영상획득)

  • 강준묵;오원진;엄대용
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.2
    • /
    • pp.167-176
    • /
    • 1999
  • The study about quantitative or qualitative analysis of object using digital image is being progressed actively with the development of the image medium and image process technique. But, it is very high that the dependency about image acquisition system of high resolution for image analysis of high accuracy and it is a equipment of high-price. In this study, I extracted the optimum condition of image enhancement by analyzing and enhancing the multiple images which were acquired by system of low-price. And I carried out the analysis of 3D accuracy by being applied the optimum condition of image enhancement. In the result of analysis of average 3D positioning error using law image and enhanced image which is acquired by applying the optimum condition of image enhancement, I could obtain the progressed accuracy about 10% on the enhanced image.

  • PDF

A Study on Effect of Various Cooling Methods in Motion of High-Precision Ball Screw (고속 고정밀 볼 스크류 구동에 따른 강제 냉각방식의 효과에 관한 연구)

  • Kim, Su-Sang;Xu, Zhe-Zhu;Kim, Hyun-Koo;Lyu, Sung-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.254-259
    • /
    • 2013
  • Ball screw system is widely used as a precision mechanical linear actuator that translates rotational motion to linear motion for its high efficiency, great stiffness and long life. Recently, according to the requirements of high accuracy and stiffness, the pre-load on the ball screw which means of remove the backlash in the ball screw is usually used. Because of the preload which means the frictional resistance between the screw and nut, becomes a dominating heat source and it generates thermal deformation of ball screw which is the reason for low accuracy of the positioning decision. There are several methods to solve the problem that includes temperature control, thermal stable design and error compensation. In the past years, researchers focused on the error compensation technique for its ability to correct ball screw error effectively rather than the capabilities of careful machine design and manufacturing. Significant amounts of researches have been done to real-time error compensation. But in this paper, we developed a series of cooling methods to get thermal equilibrium in the ball screw system. So we find the optimum cooling type for improving positioning error which caused by thermal deformation in the ball screw system.

3-D vision sensor for arc welding industrial robot system with coordinated motion

  • Shigehiru, Yoshimitsu;Kasagami, Fumio;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.382-387
    • /
    • 1992
  • In order to obtain desired arc welding performance, we already developed an arc welding robot system that enabled coordinated motions of dual arm robots. In this system one robot arm holds a welding target as a positioning device, and the other robot moves the welding torch. Concerning to such a dual arm robot system, the positioning accuracy of robots is one important problem, since nowadays conventional industrial robots unfortunately don't have enough absolute accuracy in position. In order to cope with this problem, our robot system employed teaching playback method, where absolute error are compensated by the operator's visual feedback. Due to this system, an ideal arc welding considering the posture of the welding target and the directions of the gravity has become possible. Another problem still remains, while we developed an original teaching method of the dual arm robots with coordinated motions. The problem is that manual teaching tasks are still tedious since they need fine movements with intensive attentions. Therefore, we developed a 3-dimensional vision guided robot control method for our welding robot system with coordinated motions. In this paper we show our 3-dimensional vision sensor to guide our arc welding robot system with coordinated motions. A sensing device is compactly designed and is mounted on the tip of the arc welding robot. The sensor detects the 3-dimensional shape of groove on the target work which needs to be weld. And the welding robot is controlled to trace the grooves with accuracy. The principle of the 3-dimensional measurement is depend on the slit-ray projection method. In order to realize a slit-ray projection method, two laser slit-ray projectors and one CCD TV camera are compactly mounted. Tactful image processing enabled 3-dimensional data processing without suffering from disturbance lights. The 3-dimensional information of the target groove is combined with the rough teaching data they are given by the operator in advance. Therefore, the teaching tasks are simplified

  • PDF

Development and Validation of an Integrated GNSS Simulator Using 3D Spatial Information (3차원 공간정보를 이용한 통합 GNSS 시뮬레이터 개발 및 검증)

  • Kim, Hye-In;Park, Kwan-Dong;Lee, Ho-Seok
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.659-667
    • /
    • 2009
  • In this study, an integrated GNSS Simulator called Inha GNSS Simulation System (IGSS) using 3D spatial information was developed and validated. Also positioning availability and accuracy improvement were evaluated under the integrated GNSS environment using IGSS. GPS and GLONASS satellite visibility predictions were compared with real observations, and their frequency of error were 6.4% and 7.5%, respectively. To evaluate positioning availability and accuracy improvement under the integrated GNSS environment, the Daejeon government complex area was selected to be the test site because the area has high-rise buildings and thus is susceptible to signal blockages. The test consists of three parts: the first is when only GPS was used; the second is when both GPS and GLONASS were simulated; and the last is when GPS, GLONASS, and Galileo were used all together. In each case, the number of visible satellites and Dilution Of Precision were calculated and compared.

The Precise Positioning with the 3D Coordinate Transformation of GPS Surveying (GPS 측량의 3차원 좌표변환에 의한 정밀위치결정)

  • Park, Woon-Yong;Yeu, Bock-Mo;Lee, Kee-Boo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.2 s.16
    • /
    • pp.47-60
    • /
    • 2000
  • On this study, Among the classification methods of land cover using satellite imagery, we compared the classification accuracy of Neural Network Classifier and that of Maximum Likelihood Classifier which has the characteristics of parametric and non-parametric classification method. In the assessment of classification accuracy, we analyzed the classification accuracy about testing area as well as training area that many analysts use generally when assess the classification accuracy. As a result, Neural Network Classifier is superior to Maximum Likelihood Classifier as much as 3% in the classification of training data. When ground reference data is used, we could get poor result from both of classification methods, but we could reach conclusion that the classification result of Neural Network Classifier is superior to the classification result of Maximum Likelihood Classifier as much as 10%.

  • PDF

Development of Intelligent GNSS Positioning Technique Based on Low Cost Module for an Alley Navigation (골목길 내비게이션을 위한 저가 모듈 기반의 지능형 GNSS 측위 기술 개발)

  • Kim, Hye In;Park, Kwan Dong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.3
    • /
    • pp.11-18
    • /
    • 2016
  • Since GNSS signals get blocked by buildings in urban canyons or narrow alleys, it is very difficult to secure a enough number of visible satellites for satellite navigation in those poor signal-reception environments. In those situations, one cannot get their coordinates or obtain accurate positions. In this study, a couple of strategies for improving positioning accuracy in urban canyons were developed and their performance was verified. First of all, we combined GPS and GLONASS measurements together and devised algorithms to quality-control observed signals and eliminate outliers. Also, a new multipath reduction scheme was applied to minimize its effect by utilizing SNR values of the observed signals. For performance verification of the developed technique, a narrow alley of 10m width located near the back gate of the Inha University was selected as the test-bed, and then we conducted static and kinematic positioning at four pre-surveyed points. We found that our new algorithms produced an 45% improvement in an open-sky environment compared with the positioning result of a low-cost u-blox receiver. In the alleys, 3-D accuracy improved by an average of 37%. In the case of kinematic positioning, especially, biases showing up in regular receivers got eliminated significantly through our new filtering algorithms.

A Study on Positioning of Nursing Service Image in General Hospital;Centering around 5 General Hospitals in Seoul (종합병원의 간호 서비스 이미지 포지셔닝 연구;서울시내 5개 병원을 중심으로)

  • Lim, Ji-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.2
    • /
    • pp.369-388
    • /
    • 1999
  • This study is a descriptive research to establish a positioning strategy of nursing service image, making a perception map on each hospital's nursing service image and ranking construct factors of nursing service image. The results in this study were as follows; 1. The rank of construct factors of nursing service image which were thought important by subjects was the first 'Kindness', the second 'Reliability', the third 'Professional Knowledge', the fourth 'Responsibility', and the fifth 'Advanced Nursing Skill'. 2. The perception map for nursing service image on each hospital showed a hierarchial structure and positioned the first B hospital, the second C hospital, the third D hospital, the fourth A hospital, and the fifth E hospital. The perception map for construct factors of nursing service image and hospitals showed the first dimension : 'Reliability', the second dimension : Kindness', the third dimension : 'Mission', 'Accuracy', 'Neat Appearance', and 'Ethical Aspect', and the fourth dimension : 'Client Advocate', 'Humanistic Consideration', 'Professional Knowledge', 'Responsibility', and 'Advanced Nursing Skill'. 3. The findings of subject's characteristics which affected degree of likeness on each hospital nursing service image to make a marketing strategy were as follows : In A hospital D hospital, and E hospital, the subject group whose hospital dates were under 1 week, education level was upper graduate university, and age was between 40's and 50's, were appeared to have low nursing service image on following construct factors : 'Kindness', 'Reliability', 'Responsibility', 'Mission', 'Neat Appearance', and 'Humanistic Consideration'. In B hospital and C hospital the subject group whose hospital dates were under 1 week or over 5 weeks, sex was woman, and age was 20' s or 40's, having a admission experience on subject hospitals, were appeared to have low nursing service image on following construct factors : 'Professional Knowledge', 'Advanced Nursing Skill', 'Ethical Aspect', and 'Humanistic Consideration'. As the based on above results, nursing managers can use positioning method to develope a marketing strategy for nursing service image.

  • PDF

The Effect of Patients Positioning System on the Prescription Dose in Radiation Therapy (방사선치료 시 자세확인시스템이 처방선량에 미치는 영향)

  • Kim, Jeong-Ho;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.613-620
    • /
    • 2017
  • Planning dose must be delivered accurately for radiation therapy. Also, It must be needed accurately setup. However, patient positioning images were need for accuracy setup. Then patient positioning images is followed by additional exposure to radiation. For 45 points in the phantom, we measured the doses for 6 MV and 10 MV photon beams, OBI(On Board Imager) and CBCT(Conebeam Computed Tomography) using OSLD(Optically Stimulated Luminescent Dosimeter). We compared the differences in the cases where posture confirmation imaging at each point was added to the treatment dose. Also, we tried to propose a photography cycle that satisfies the 5% recommended by AAPM(The American Association of Physicists in Medicine). As a result, a maximum of 98.6 cGy was obtained at a minimum of 45.27 cGy at the 6 MV, a maximum of 99.66 cGy at a minimum of 53.34 cGy at the 10 MV, a maximum of 2.64 cGy at the minimum of 0.19 cGy for the OBI and a maximum of 17.18 cGy at the minimum of 0.54 cGy for the CBCT.The ratio of the radiation dose to the treatment dose is 3.49% in the case of 2D imaging and the maximum is 22.65% in the case of 3D imaging. Therefore, tolerance of 2D image is 1 exposure per day, and 3D image is 1 exposure per week. And it is need to calculation of separate in the parallelism at additional study.

Optimizing Laser Scanner Selection and Installation through 3D Simulation-Based Planning - Focusing on Displacement Measurements of Retaining Wall Structures in Small-scale Buildings -

  • Lee, Gil-yong;Kim, Jun-Sang;Yoou, Geon hee;Kim, Young Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.3
    • /
    • pp.68-82
    • /
    • 2024
  • The planning stage of laser scanning is crucial for acquiring high-quality 3D source data. It involves assessing the target space's environment and formulating an effective measurement strategy. However, existing practices often overlook on-site conditions, with decisions on scanner deployment and scanning locations relying heavily on the operators' experience. This approach has resulted in frequent modifications to scanning locations and diminished 3D data quality. Previous research has explored the selection of optimal scanner locations and conducted preliminary reviews through simulation, but these methods have significant drawbacks. They fail to consider scanner inaccuracies, do not support the use of multiple scanners, rely on less accurate 2D drawings, and require specialized knowledge in 3D modeling and programming. This study introduces an optimization technique for laser scanning planning using 3D simulation to address these issues. By evaluating the accuracy of scan data from various laser scanners and their positioning for scanning a retaining wall structure in a small-scale building, this method aids in refining the laser scanning plan. It enhances the decision-making process for end-users by ensuring data quality and reducing the need for plan adjustments during the planning phase.

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.