This study was performed to investigate the survival rate of single implant used in maxillary anterior region during follow up periods. 231 patients whose single missing tooth in maxillary region had been replaced with 237 implant at the periodontal dept. of Yonsei University Hospital between February 1993 and December 2004. The following results are compiled from 231 patients who received single implant surgery. 1. The major cause of single tooth loss in maxillary anterior region is trauma, followed by periodontal disease and congenital missing. 2. The total survival rate of single implant placed in maxillary anterior region is 94.5%. 3. The survival rate of single implant placed in type II and type IV was 100% and in type III was 92.7%. As for the bone quantity, the survival rate in type A(100%) was most, followed by type B(97.3%) and type C, D (93.5%). 4. The survival rate of implant placement combined with advanced surgery was 94.4%. The results showed that the placement of single implant is considered as a reliable treatment option for a single missing tooth in maxillary anterior region except in certain extreme conditions especially with poor bone quality and quantity.
Kim, Sung-Young;Lee, Mi-Jeong;Moon, Jang-Won;Lee, Se-Joon;Yu, Mi-Kyung
Restorative Dentistry and Endodontics
/
v.30
no.1
/
pp.31-37
/
2005
The aim of this study was to evaluate the effectiveness of sealer placement in simulated root canal extensions. Forty resin blocks were attained from the Endo-training Bloc. In each block. The simulated root canal was made with $\#20$, 80taper GT file. After each block was longitudinally split into two halves, a standardized groove was prepared on one canal wall of two halves to simulate the canal extensions with various irregularities. The two halves of each block were assembled and all simulated root canals were obturated by single cone method with AH26 sealer. Four different methods of sealer placement were used: group A, $\#20$ K-file; group B, ultrasonic file; group C, lentulo spiral; group D, EZ-Fill bi-directional spiral. All obturated blocks were stored in $100\%$ humidity at $37^{\circ}C$ for 1 week, Using a low speed saw, each block was sectioned horizontally. Images of the sections were taken using a stereomicroscope at $\times$ 30 magnification and a digital camera. The amount of the sealer in the groove was evaluated using a scoring system, a higher score indicated better sealing effectiveness. The data was statistically analysed by Fisher's Exact Test. The sealing score was the lowest, specially at the middle area of canal extensions in group A, and that was statistically significant difference from other groups. In conclusion, the ultrasonic file, lentulo spiral and EZ-Fill bi-directional spiral were effective methods of sealer placement in simulated canal extensions. The K file was the least effective method, specially at the middle area of canal extensions.
Electric machines such as motors which have rmving parts are designed for producing mechanical force or torque. The accurate calculations of electromagnetic force and torque are important in the design these machines. Electromagnetic force calculation method using the results of Finite Element Method(FEM) has been presented variously in 2-D problems. Typically the Maxwell's Stress Tensor method and the method of virtual work are used. The former calculates forces by integrating the surface force densities which can be expressed in terms of Maxwell Stress Tensor(MST), and the latter by differentiating the electromagnetic energy with respect to the virtual dis¬placement of rigid bodies of interest. In the problems including current source, magnetic vector potentials(MVP) have rmstly been used as unknown variables for field analysis by a numerical method; e. g. FEM. This paper, thus, introduces the two both methods using MVP in 3-D case. To verify the usefulness of presented methods, a solenoid model is chosen and analyzed by 3-D and axisymmetric FEM. It is found that the force calculation results are in good agreement for several mesh schemes.
In early stages of film or animation production, storyboard is used to visually describe the outline of a story. Drawings or photographs, as well as the texts, are employed for character / item placements and camera pose. However, commercially available storyboard tools are mainly drawing and editing tools, not providing functionality for item placement and camera control. In this paper, an Augmented Reality based storyboard tool is presented, which provides an intuitive and easy-to-use interface for storyboard development. Using the presented tool, non-expert users may compose 30 scenes in his or her real environments through tangible building blocks which are used to fetch corresponding 3D models and their pose.
In replicated field trials, the efficacy of pentachloronitrobenzene (PCNB; quintozene) for control of damping-off of ginseng seedlings was found to be affected by timing of application and formulation. Application at the time of seeding and prior to placement of straw mulch was found to provide the moat consistent level of disease control. However, decline in plant stand during the four-year production cycle resulted in most treatments providing similar levels of plant populations at harvest. Soil residues of pentachloronitrobenzene were generally highest (1 $\mu\textrm{g}$ PCNB/g soil) in those treatments that exhibited the highest levels of disease control in the seedling year. Straw contained high levels of quintozene after application. Beet seed assays with artificially-infested soils indicated that current use rates provide an amount of product suitable for high levels of disease control.
Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.
Backgrounds: The purpose of this study is to discuss the total joint reconstruction surgery for a patient with recurrent ankylosis in bilateral temporomandibular joints (TMJs) using three-dimensional (3D) virtual surgical planning, computer-aided manufacturing (CAD/CAM)-fabricated surgical guides, and stock TMJ prostheses. Case presentation: A 66-year-old female patient, who had a history of multiple TMJ surgeries, complained of severe difficulty in eating and trismus. The 3D virtual surgery was performed with a virtual surgery software (FACEGIDE, MegaGen implant, Daegu, South Korea). After confirmation of the location of the upper margin for resection of the root of the zygoma and the lower margin for resection of the ankylosed condyle, and the position of the fossa and condyle components of stock TMJ prosthesis (Biomet, Jacksonville, FL, USA), the surgical guides were fabricated with CAD/CAM technology. Under general anesthesia, osteotomy and placement of the stock TMJ prosthesis (Biomet) were carried out according to the surgical planning. At 2 months after the operation, the patient was able to open her mouth up to 30 mm without complication. Conclusion: For a patient who has recurrent ankylosis in bilateral TMJs, total joint reconstruction surgery using 3D virtual surgical planning, CAD/CAM-fabricated surgical guides, and stock TMJ prostheses may be an effective surgical treatment option.
Graf, Tobias;Guth, Jan-Frederik;Diegritz, Christian;Liebermann, Anja;Schweiger, Josef;Schubert, Oliver
The Journal of Advanced Prosthodontics
/
v.13
no.6
/
pp.351-360
/
2021
PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 ㎛ in group CF and 34 ± 6 ㎛ in group PC. RMSE of total adjustments was 61 ± 11 ㎛ in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.
International Journal of Advanced Culture Technology
/
v.1
no.2
/
pp.24-32
/
2013
This paper determined students' ranks of difficulty on the use of materials in terms of 1) understanding the layout of the learning materials, 2) reading comprehension of the learning materials, and 3) realization on relevance to needs of the learning materials. It also determined students' 4) rank and frequency of attitude on the materials. With the data gathered through 128 survey questionnaires, 7 focused group discussions, and 10 interviews, the results were found out that there was an inappropriate assessment procedure set by this particular university. The researcher concludes that: 1) design of four types of classes by just using the two textbooks with their respective workbooks is grammar-based with limited conversation activities; 2) placement for these students in one big class size was implemented without considering their common interest and motivation and language levels; and, 3) qualification of teachers teaching these EFL students did not support students' real needs and the language program itself. Content professors who were made to teach may have the ability to input learning, but their teaching styles may differ from the ones who are real English teachers. This paper then recommends that teachers and school administration should have an appropriate placement exam before students attend the class, especially in a big class size. There could only be a few problems among students in one big class size when students' level of competence is proportioned. With this, topics and conversation activities can even be more flexible with the maneuver of art of questioning, various dimensions of thinking, strategic competence, learning attitude or behavior, etc. to ensure sustenance of communicative mode and level of interest and motivation in the classroom. Grammar-based instruction can only be taught when a need arises. Thus, the course description of each class will be able to transact the objectives ready for developing students' communication competence. Moreover, proper measurement can be utilized to validly assess the amount of students' learning and the progress of language curriculum design in terms of materials selection and teaching approach.
Transactions of the Korean Society of Mechanical Engineers A
/
v.35
no.5
/
pp.517-523
/
2011
Anterior cruciate ligament (ACL) injuries are treatedwith surgical reconstruction. Although ACL consists of two functional bundles, only the anteromedial bundle is surgically reconstructed, and the effect of the reconstruction of the posterolateral bundle is unknown. The purpose of this study is to investigate the role of the posterolateral bundle and the effect of double-bundle reconstruction during single-leg landing. A 3D dynamic knee with various ACL reconstructed models was created using MRI, and single-leg landing motion was simulated using in-vivo human experimental data. The results showed that the lateral shift of the tibial insertion of the anteromedial bundle and the posterolateral bundle of the ACL constrain the tibial internal rotation more efficiently than a single anteromedial bundle can. In addition, double-bundle ACL reconstruction is less sensitive to inaccuracies in the tibial tunnel placement.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.