• Title/Summary/Keyword: 3D placement

Search Result 155, Processing Time 0.027 seconds

A Retrospective clinical study of survival rate of single implant in maxillary anterior teeth (상악 전치부 단일 임플란트의 생존율에 대한 후향적 연구)

  • Im, Ji-Soon;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho;Chai, Jung-Kyu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.639-651
    • /
    • 2006
  • This study was performed to investigate the survival rate of single implant used in maxillary anterior region during follow up periods. 231 patients whose single missing tooth in maxillary region had been replaced with 237 implant at the periodontal dept. of Yonsei University Hospital between February 1993 and December 2004. The following results are compiled from 231 patients who received single implant surgery. 1. The major cause of single tooth loss in maxillary anterior region is trauma, followed by periodontal disease and congenital missing. 2. The total survival rate of single implant placed in maxillary anterior region is 94.5%. 3. The survival rate of single implant placed in type II and type IV was 100% and in type III was 92.7%. As for the bone quantity, the survival rate in type A(100%) was most, followed by type B(97.3%) and type C, D (93.5%). 4. The survival rate of implant placement combined with advanced surgery was 94.4%. The results showed that the placement of single implant is considered as a reliable treatment option for a single missing tooth in maxillary anterior region except in certain extreme conditions especially with poor bone quality and quantity.

AN IN-VITRO EVALUATION OF SEALER PLACEMENT METHODS IN SIMULATED ROOT CANAL EXTENSIONS (근관 내 불규칙 확장부에서 sealer 적용방법에 따른 충전 효과 평가)

  • Kim, Sung-Young;Lee, Mi-Jeong;Moon, Jang-Won;Lee, Se-Joon;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • The aim of this study was to evaluate the effectiveness of sealer placement in simulated root canal extensions. Forty resin blocks were attained from the Endo-training Bloc. In each block. The simulated root canal was made with $\#20$, 80taper GT file. After each block was longitudinally split into two halves, a standardized groove was prepared on one canal wall of two halves to simulate the canal extensions with various irregularities. The two halves of each block were assembled and all simulated root canals were obturated by single cone method with AH26 sealer. Four different methods of sealer placement were used: group A, $\#20$ K-file; group B, ultrasonic file; group C, lentulo spiral; group D, EZ-Fill bi-directional spiral. All obturated blocks were stored in $100\%$ humidity at $37^{\circ}C$ for 1 week, Using a low speed saw, each block was sectioned horizontally. Images of the sections were taken using a stereomicroscope at $\times$ 30 magnification and a digital camera. The amount of the sealer in the groove was evaluated using a scoring system, a higher score indicated better sealing effectiveness. The data was statistically analysed by Fisher's Exact Test. The sealing score was the lowest, specially at the middle area of canal extensions in group A, and that was statistically significant difference from other groups. In conclusion, the ultrasonic file, lentulo spiral and EZ-Fill bi-directional spiral were effective methods of sealer placement in simulated canal extensions. The K file was the least effective method, specially at the middle area of canal extensions.

Electromagnetic Force Calculation Using Magnetic Vector Potentials in 3-D Problems (자기벡터포텐셜을 이용한 3차원 전자력 계산)

  • 양재진;이복용;이기식
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.106-111
    • /
    • 1996
  • Electric machines such as motors which have rmving parts are designed for producing mechanical force or torque. The accurate calculations of electromagnetic force and torque are important in the design these machines. Electromagnetic force calculation method using the results of Finite Element Method(FEM) has been presented variously in 2-D problems. Typically the Maxwell's Stress Tensor method and the method of virtual work are used. The former calculates forces by integrating the surface force densities which can be expressed in terms of Maxwell Stress Tensor(MST), and the latter by differentiating the electromagnetic energy with respect to the virtual dis¬placement of rigid bodies of interest. In the problems including current source, magnetic vector potentials(MVP) have rmstly been used as unknown variables for field analysis by a numerical method; e. g. FEM. This paper, thus, introduces the two both methods using MVP in 3-D case. To verify the usefulness of presented methods, a solenoid model is chosen and analyzed by 3-D and axisymmetric FEM. It is found that the force calculation results are in good agreement for several mesh schemes.

  • PDF

Augmented Reality based Interactive Storyboard System (증강현실 기반의 인터랙티브 스토리보드 제작 시스템)

  • Park, Jun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.13 no.2
    • /
    • pp.17-22
    • /
    • 2007
  • In early stages of film or animation production, storyboard is used to visually describe the outline of a story. Drawings or photographs, as well as the texts, are employed for character / item placements and camera pose. However, commercially available storyboard tools are mainly drawing and editing tools, not providing functionality for item placement and camera control. In this paper, an Augmented Reality based storyboard tool is presented, which provides an intuitive and easy-to-use interface for storyboard development. Using the presented tool, non-expert users may compose 30 scenes in his or her real environments through tangible building blocks which are used to fetch corresponding 3D models and their pose.

  • PDF

Impacts of Different Pentachloronitrobenzene (quintozene) Use Patterns on Severity of Damping-off of Ginseng (Panu quinquefolitrs)

  • Reeleder, R.D;Capell, B
    • Journal of Ginseng Research
    • /
    • v.26 no.1
    • /
    • pp.10-16
    • /
    • 2002
  • In replicated field trials, the efficacy of pentachloronitrobenzene (PCNB; quintozene) for control of damping-off of ginseng seedlings was found to be affected by timing of application and formulation. Application at the time of seeding and prior to placement of straw mulch was found to provide the moat consistent level of disease control. However, decline in plant stand during the four-year production cycle resulted in most treatments providing similar levels of plant populations at harvest. Soil residues of pentachloronitrobenzene were generally highest (1 $\mu\textrm{g}$ PCNB/g soil) in those treatments that exhibited the highest levels of disease control in the seedling year. Straw contained high levels of quintozene after application. Beet seed assays with artificially-infested soils indicated that current use rates provide an amount of product suitable for high levels of disease control.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

Total joint reconstruction using computer-assisted surgery with stock prostheses for a patient with bilateral TMJ ankylosis

  • Rhee, Seung-Hyun;Baek, Seung-Hak;Park, Sang-Hun;Kim, Jong-Cheol;Jeong, Chun-Gi;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.41.1-41.6
    • /
    • 2019
  • Backgrounds: The purpose of this study is to discuss the total joint reconstruction surgery for a patient with recurrent ankylosis in bilateral temporomandibular joints (TMJs) using three-dimensional (3D) virtual surgical planning, computer-aided manufacturing (CAD/CAM)-fabricated surgical guides, and stock TMJ prostheses. Case presentation: A 66-year-old female patient, who had a history of multiple TMJ surgeries, complained of severe difficulty in eating and trismus. The 3D virtual surgery was performed with a virtual surgery software (FACEGIDE, MegaGen implant, Daegu, South Korea). After confirmation of the location of the upper margin for resection of the root of the zygoma and the lower margin for resection of the ankylosed condyle, and the position of the fossa and condyle components of stock TMJ prosthesis (Biomet, Jacksonville, FL, USA), the surgical guides were fabricated with CAD/CAM technology. Under general anesthesia, osteotomy and placement of the stock TMJ prosthesis (Biomet) were carried out according to the surgical planning. At 2 months after the operation, the patient was able to open her mouth up to 30 mm without complication. Conclusion: For a patient who has recurrent ankylosis in bilateral TMJs, total joint reconstruction surgery using 3D virtual surgical planning, CAD/CAM-fabricated surgical guides, and stock TMJ prostheses may be an effective surgical treatment option.

Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based

  • Graf, Tobias;Guth, Jan-Frederik;Diegritz, Christian;Liebermann, Anja;Schweiger, Josef;Schubert, Oliver
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.351-360
    • /
    • 2021
  • PURPOSE. The aim of this study was to evaluate the efficiency of occlusal and interproximal adjustments of single implant crowns (SIC), comparing a digital cast-free approach (CF) and a protocol using 3D printed casts (PC). MATERIALS AND METHODS. A titanium implant was inserted at position of lower right first molar in a typodont. The implant position was scanned using an intraoral scanner and SICs were fabricated accordingly. Ten crowns (CF; n = 10) were subject to a digital cast-free workflow without any labside occlusal and interproximal modifications. Ten other identical crowns (PC) were adjusted to 3D printed casts before delivery. All crowns were then adapted to the testing model, simulating chair-side adjustments during clinical placement. Adjustment time, quantity of adjustments, and contact relationship were assessed. Data were analyzed using SPSS software (P < .05). RESULTS. Median and interquartile range (IQR) of clinical adjustment time was 02:44 (IQR 00:45) minutes in group CF and 01:46 (IQR 00:21) minutes in group PC. Laboratory and clinical adjustment time in group PC was 04:25 (IQR 00:59) minutes in total. Mean and standard deviation (±SD) of root mean squared error (RMSE) of quantity of clinical adjustments was 45 ± 7 ㎛ in group CF and 34 ± 6 ㎛ in group PC. RMSE of total adjustments was 61 ± 11 ㎛ in group PC. Quality of occlusal contacts was better in group CF. CONCLUSION. Time effort for clinical adjustments was higher in the cast-free protocol, whereas quantity of modifications was lower, and the occlusal contact relationship was found more favourable.

Effects on the Use of Two Textbooks for Four Types of Classes in a South Korean University

  • Ramos, Ian Done D.
    • International Journal of Advanced Culture Technology
    • /
    • v.1 no.2
    • /
    • pp.24-32
    • /
    • 2013
  • This paper determined students' ranks of difficulty on the use of materials in terms of 1) understanding the layout of the learning materials, 2) reading comprehension of the learning materials, and 3) realization on relevance to needs of the learning materials. It also determined students' 4) rank and frequency of attitude on the materials. With the data gathered through 128 survey questionnaires, 7 focused group discussions, and 10 interviews, the results were found out that there was an inappropriate assessment procedure set by this particular university. The researcher concludes that: 1) design of four types of classes by just using the two textbooks with their respective workbooks is grammar-based with limited conversation activities; 2) placement for these students in one big class size was implemented without considering their common interest and motivation and language levels; and, 3) qualification of teachers teaching these EFL students did not support students' real needs and the language program itself. Content professors who were made to teach may have the ability to input learning, but their teaching styles may differ from the ones who are real English teachers. This paper then recommends that teachers and school administration should have an appropriate placement exam before students attend the class, especially in a big class size. There could only be a few problems among students in one big class size when students' level of competence is proportioned. With this, topics and conversation activities can even be more flexible with the maneuver of art of questioning, various dimensions of thinking, strategic competence, learning attitude or behavior, etc. to ensure sustenance of communicative mode and level of interest and motivation in the classroom. Grammar-based instruction can only be taught when a need arises. Thus, the course description of each class will be able to transact the objectives ready for developing students' communication competence. Moreover, proper measurement can be utilized to validly assess the amount of students' learning and the progress of language curriculum design in terms of materials selection and teaching approach.

  • PDF

Effect of Lateral and Posterior Placement of Single-Bundle and Double-Bundle ACL Reconstructions on Tibial Internal Rotation During Single-Leg Landing (전방십자인대 한다발재건술의 후외측다발 재건 및 두다발재건술이 외발착지 동작 시에 경골내회전에 미치는 영향)

  • Shin, Choong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.517-523
    • /
    • 2011
  • Anterior cruciate ligament (ACL) injuries are treatedwith surgical reconstruction. Although ACL consists of two functional bundles, only the anteromedial bundle is surgically reconstructed, and the effect of the reconstruction of the posterolateral bundle is unknown. The purpose of this study is to investigate the role of the posterolateral bundle and the effect of double-bundle reconstruction during single-leg landing. A 3D dynamic knee with various ACL reconstructed models was created using MRI, and single-leg landing motion was simulated using in-vivo human experimental data. The results showed that the lateral shift of the tibial insertion of the anteromedial bundle and the posterolateral bundle of the ACL constrain the tibial internal rotation more efficiently than a single anteromedial bundle can. In addition, double-bundle ACL reconstruction is less sensitive to inaccuracies in the tibial tunnel placement.