• 제목/요약/키워드: 3D motion

검색결과 2,044건 처리시간 0.037초

Representation Techniques for 4-Dimensional MR Images

  • Homma, Kazuhiro;Takenaka, Kenji;Nakai, Yoshihiko;Hirose, Takeshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.429-431
    • /
    • 2002
  • Metabolic analysis of biological tissues, the interventional radiology in MRT (Magnetic Resonance Treatment) and for clinical diagnoses, representation of 4-Dimensional (4D) structural information (x,y,z,t) of biological tissues is required. This paper discusses image representation techniques for those 4D MR Images. We have proposed an image reconstruction method for ultra-fast 3D MRI. It is based on image interpolation and prediction of un-acquired pictorial data in both of the real and the k-space (the acquisition domain in MRI). A 4D MR image is reconstructed from only two 3D MR images and acquired a few echo signals that are optimized by prediction of the tissue motion. This prediction can be done by the phase of acquired echo signal is proportioned to the tissue motion. On the other hand, reconstructed 4D MR images are represented as a 3D-movie by using computer graphics techniques. Rendered tissue surfaces and/or ROIs are displayed on a CRT monitor. It is represented in an arbitrary plane and/or rendered surface with their motion. As examples of the proposed representation techniques, the finger and the lung motion of healthy volunteers are demonstrated.

  • PDF

3D Conversion of 2D Video Encoded by H.264

  • Hong, Ho-Ki;Ko, Min-Soo;Seo, Young-Ho;Kim, Dong-Wook;Yoo, Ji-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.990-1000
    • /
    • 2012
  • In this paper, we propose an algorithm that creates three-dimensional (3D) stereoscopic video from two-dimensional (2D) video encoded by H.264 instead of using two cameras conventionally. Very accurate motion vectors are available in H.264 bit streams because of the availability of a variety of block sizes. 2D/3D conversion algorithm proposed in this paper can create left and right images by using extracted motion information. Image type of a given image is first determined from the extracted motion information and each image type gives a different conversion algorithm. The cut detection has also been performed in order to prevent overlapping of two totally different scenes for left and right images. We show an improved performance of the proposed algorithm through experimental results.

손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구 (Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement)

  • 박선하;박지혁;김종배;정영진;이주현;박혜연
    • 재활치료과학
    • /
    • 제12권1호
    • /
    • pp.79-92
    • /
    • 2023
  • 목적 : 본 연구는 손목과 손가락 관절가동범위 측정에 대한 3차원 동작분석 프로그램의 신뢰도를 알아보고자 하였다. 연구방법 : 연구 대상자는 정상인으로 손목과 손가락의 움직임에 제한이 없는 자, 본 연구의 목적을 이해하고 참여에 동의한 자 50명을 대상으로 하였다. 측각기와 3차원 동작분석 프로그램을 사용하여 총 11항목의 손목과 손가락 관절가동범위를 각각 1회씩 측정하였다. 3차원 동작분석 프로그램의 신뢰도를 측정하기 위해 측정값의 일치도와 불일치 양상을 비교하였다. 결과 : 측정값의 일치도를 분석한 결과 44개의 항목 중 38개 측정항목에서 매우 높은 일치도를 보였으며, 측정값의 불일치 양상을 분석한 결과 3가지 항목에서 불일치 양상이 나타났다. 결론 : 본 연구 결과를 통해 본 연구에서 사용한 3차원 동작분석 프로그램을 통해 관절가동범위 측정이 가능함을 알 수 있었다. 또한 3차원 동작분석 프로그램의 측정의 편리성, 정확성의 장점을 기반으로 다양한 임상 분야에서 활용되기를 기대한다.

단안 영상 시퀸스에서 움직임 추정 기반의 3차원 깊이 정보 추출 알고리즘 (3D Depth Information Extraction Algorithm Based on Motion Estimation in Monocular Video Sequence)

  • 박준호;전대성;윤영우
    • 정보처리학회논문지B
    • /
    • 제8B권5호
    • /
    • pp.549-556
    • /
    • 2001
  • 2차원 영상으로 부터 3차원 영상으로 복원하는 일은 일반적으로 카메라의 초점에서 영상 프레임의 각 픽셀까지의 깊이 정보가 필요하고, 3차원 모델의 복원에 관한 일반적인 수작업은 많은 식나과 비용이 소모된다. 본 논문에서는 카메라의 움직임이 포함되어 있는 단안 영상 시퀸스로부터 3차원 영상 제작에 필요한 상대적인 깊이 정보를 실시간으로 추출하는 알고리즘을 제안하고, 하드웨어를 구현하기 위한여 알고리즘을 단순화하였다. 이 알고리즘은 카메라 이동에 의한 영상의 모든 점들의 움직임은 깊이 정보의 종속적이라는 사실에 기반을 두고 있다. 불록매칭 알고리즘에 기반을 둔 전역 움직임 탐색에 의한 움직임 벡터를 추출한 후, 카메라 회전과 확대/축소에 관한 카메라 움직임 보상을 실행하고 깉이 정보 추출 과정이 전개된다. 깊이 정보 추출 과정은 단안 영상에서 객체의 이동처리를 분석하여 움직임 벡터를 구하고 프레임내의 모든 픽셀에 대한 평균 깊이를 계산한 후, 평균 깊이에 대한 각 블록의 상대적 깊이를 산출하였다. 모의 실험 결과 전경과 배경에 속하는 영역의 깊이는 인간 시각 체계가 인식하는 상대적인 깊이와 일치한다는 것을 보였다.

  • PDF

HIMM을 이용한 3차원 지도작성 (3D Map-Building using Histogramic In-Motion Mapping in the Eyebot)

  • 정현룡;김영배
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1127-1130
    • /
    • 2003
  • This paper introduces histogramic in-motion mapping for real-time map building with the Eyebot in motion. A histogram grid used in HIMM is updated through three PSD sensors. HIMM makes it possible to make fast map-building and avoid obstacles in real-time. Fast map-building allows the robot to immediately use the mapped information in real-time obstacle-avoidance algorithms. HIMM has been tested on the Eyebot. The Eyebot sends PSD data to computer and computer builds a 3D-Map based on PSD data.

  • PDF

관절염질환자의 관절가동범위에 대응한 착탈의 동작평가 (The Motion Evaluation of Arthritis Patients' Dressing and Undressing Corresponding to their Joint Range of Motion)

  • 한승희;최미성
    • 한국의상디자인학회지
    • /
    • 제14권2호
    • /
    • pp.75-87
    • /
    • 2012
  • This study aims at measuring and comparing the joint range of motion(ROM) of the elderly, quantitatively understanding the joint ROM and duration for their dressing and undressing of pants with 3D motion analysis equipment, and thereby providing basic data necessary for the future development of clothes carrying functional designs. The findings are as follows. As for the study method, the 9-item joint ROM measurements were conducted with goniometer, and the questionnaire analyses were carried out for t-test, ANOVA, and regression analysis with spss12.0 program. The 3D motion analyses were handled with 3D Motion Analysis Package Version 3.1 Program. The findings are as follows. First, the ROM was shown to be significantly low, as the arthritis-pain consciousness level was felt higher by the subject than the average one. Seven ROM variables, such as hip flexion, hip adduction, hip internal rotation, hip external rotation, knee flexion, ankle dorsiflexion, and ankle plantar flexion, were shown to significantly affect the discomfort level experienced at the time of dressing or undressing. Second, in the motion of inserting the remaining leg into the pant crotch part(3e), the difference of angles in the hip joint and knee joint was the largest between the women in their 20s and the elderly women with arthritis. Third.

  • PDF

적응적인 임계값을 적용한 정확한 움직임 검출과 이를 이용한 효율적인 3-D 디인터레이싱 알고리즘 (An Efficient 3-D Deinterlacing Algorithm by Detecting Accurate Motions Using Adaptive-Thresholded Values)

  • 조대림;송진모;이동호
    • 한국멀티미디어학회논문지
    • /
    • 제13권11호
    • /
    • pp.1610-1620
    • /
    • 2010
  • 본 논문에서는 적응적인 임계값을 이용한 정확한 움직임 추정방법과 이진영상에서의 미리 정의한 패턴을 이용한 에지 기반 공간 필터링 방법을 이용한 적응적 3-D 디인터레이싱 알고리즘을 제안한다. 움직임 예측시 발생하는 움직임 미검출과 거짓 움직임 검출을 줄이기 위해서 영상내의 복잡도에 따라 적응적인 임계값을 적용 하였다. 움직임 영역에서의 공간 필터를 사용할 경우 완만한 대각 방향의 에지와 라인의 보간 성능을 높이기 위해 최근에 발표된 미리 정의한 이진 패턴을 이용한 에지기반의 필터링 방법에서 이진 패턴의 재구성을 통해 보간하는 방법을 제안하였다. 제안된 알고리즘을 사용할 경우 기존의 방법들에 비해 시각적으로 뛰어난 결과를 보이는 것을 모의실험을 통해 확인하였다.

모션캡처 시스템을 위한 추상레이어의 설계 (The Design of Abstract Layer for Motion Capture System)

  • 이희만
    • 한국컴퓨터정보학회논문지
    • /
    • 제12권1호
    • /
    • pp.25-32
    • /
    • 2007
  • 본 논문은 다양한 모션캡처 하드웨어 장비에 독립적인 응용 프로그램을 작성할 수 있도록 단일화된 추상 레이어를 설계하고 구현하였다. 설계한 추상레이어의 기능을 테스트하고 검증하기 위하여 광학식 모션캡처 시스템과 기계식 모션 캡처 시스템을 각각 AOA 파일과 BVH 파일을 이용하여 에뮬레이션 하였다. 응용 프로그램에서 추상레이어 함수의 호출에 의해 광학식 및 기계식 모션캡처 시스템을 각각 구동하고 시간에 따른 프레임 데이터를 Direct3D를 이용하여 애니메이션 하였다.

  • PDF

상지 재활을 위한 3-D 로봇 시스템의 개발 (Development of a 3-D Rehabilitation Robot System for Upper Extremities)

  • 신규현;이수한
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.64-71
    • /
    • 2009
  • A 3-D rehabilitation robot system is developed in this paper. The robot system is for the rehabilitation of upper extremities, especially the shoulder and elbow joints, and has 3-D workspace for enabling occupational therapy to recover physical functions in activities of daily living(ADL). The rehabilitation robot system, which is driven by actuators, has 1 DOF in horizontal rotational motion and 2 DOF in vertical rotational motion, where all actuators are set on the ground. Parallelogram linkage mechanisms lower the equivalent inertia of the control elements as well as control forces. Also the mechanisms have high mechanical rigidity for the end effector and the handle. Passive motion mode experiments have been performed to evaluate the proposed robot system. The results of the experiments show and excellent performance in simulating spasticity of patients.