• 제목/요약/키워드: 3D human body scan data

검색결과 64건 처리시간 0.019초

성인 남성 머리와 얼굴 부위의 형태분류와 3차원적 분석 (Classification of Head Shape and 3-dimensional analysis for Korean Men)

  • 최영림;김재승;남윤자
    • 한국의류산업학회지
    • /
    • 제12권6호
    • /
    • pp.812-820
    • /
    • 2010
  • The objectives of this study were to classify the head shapes of Korean men and to suggest computer tomography as a new body measurement method. The 23 head measurement items of 760 men, aged more than 18 in Sizekorea 2004 database were used to analyze, measured by using statistical methods. Factor analysis, cluster analysis and duncan test were performed using these data. Through factor analysis, 5 factors were extracted upon factor scores and those factors comprised 70.91% for the total variances. The head and face shapes were categorized as 5 types-triangle, round, oval, long, rectangle. We decided for the type 1(triangle) to standard head shape since this type was the most observed. 21 participants were measured using computed tomography(CT). The measured data of skin and skeleton and the standard head shapes were illustrated.

슬랙스 형태 적합성 평가의 정량적 평가 기준 설정 (Establishing Quantitative Evaluation Standards for the Shape Fitness test of Slacks)

  • 김선영
    • 한국의류산업학회지
    • /
    • 제18권5호
    • /
    • pp.695-707
    • /
    • 2016
  • This study presents quantitative evaluation standards for the shape fitness test, conducted in the process of the slacks fit test. This study aims to quantify appearance sensory test of slacks for the objectification of qualitative evaluation methods in existing shape fitness tests. The subjects were women of standard body type between the ages of 18 and 24. Slacks differing in their ease in waist girth, hip girth, crotch length and knee length were designed to test their shape fitness. The gap volume distribution between the body and slack, angle of the baseline by body part, and ratio of total thickness from the sideline using 3D human body scan data (which reflect the results of the appearance sensory test) were presented as quantitative evaluation standards. There were less wrinkles in the wrinkle/overstretch and ease categories of the appearance sensory test; in addition, ease was adequate and small enough to comfortably perform basic human activities in the standing upright posture. The gap volume distribution analysis between body and slacks showed that curves increased in the slacks surface along with an increase of ease in slacks and suggested that wrinkles also increased. In the baseline's horizontal categories in terms of a $0^{\circ}$ horizontal angle, the range of angles were evaluated as adequate by the clothing expert group. The total thickness ratio of 0.5:0.5 divides into the sideline from the baseline.

도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS) (320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection)

  • 오동인;이민형;김희진;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

Grid method에 의한 성인 여성 3차원 형상의 상반신 앞판에 대한 평면전개 기준 연구 (Surface Flattening criterion of Female's Upper Front Shell Using Grid Method)

  • 최영림;남윤자;최경미;최명해;한설아
    • 한국의류학회지
    • /
    • 제32권12호
    • /
    • pp.1825-1836
    • /
    • 2008
  • 3차원 인체 형상에 적합한 의복 패턴을 제작하기 위하여 인체 형상을 평면전개하여 체표패턴을 얻기 위한 다양한 연구들이 진행되고 있다. 본 연구는 Grid method를 이용한 여성 상반신 앞면의 평면전개를 위하여 최적 그리드 기준을 결정하는 것을 목적으로 하였다. Grid method는 인체 형상의 표면에 커브를 생성하고 각 커브의 길이를 플로팅하는 원리에 의하여 3차원 형상을 평면전개 방법이다. 첫째, Young 모델과 Adult 모델에 해당하는 두 개의 3차원 바디들을 사이즈코리아데이타에 기초하여 모델링하였다. 둘째, 각각의 모델을 3차원 특징점에 의하여 shell과 block으로 세분화하였다. 셋째, 각각의 block은 다양한 그리드수의 조합에 의하여 평면전개되었다. 마지막으로, 가장 효율적인 조합을 선정하여 평면전개의 기준으로 제시하였다.