• Title/Summary/Keyword: 3D human body scan data

Search Result 64, Processing Time 0.023 seconds

Classification of Head Shape and 3-dimensional analysis for Korean Men (성인 남성 머리와 얼굴 부위의 형태분류와 3차원적 분석)

  • Choi, Young-Lim;Kim, Jae-Seung;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.12 no.6
    • /
    • pp.812-820
    • /
    • 2010
  • The objectives of this study were to classify the head shapes of Korean men and to suggest computer tomography as a new body measurement method. The 23 head measurement items of 760 men, aged more than 18 in Sizekorea 2004 database were used to analyze, measured by using statistical methods. Factor analysis, cluster analysis and duncan test were performed using these data. Through factor analysis, 5 factors were extracted upon factor scores and those factors comprised 70.91% for the total variances. The head and face shapes were categorized as 5 types-triangle, round, oval, long, rectangle. We decided for the type 1(triangle) to standard head shape since this type was the most observed. 21 participants were measured using computed tomography(CT). The measured data of skin and skeleton and the standard head shapes were illustrated.

Establishing Quantitative Evaluation Standards for the Shape Fitness test of Slacks (슬랙스 형태 적합성 평가의 정량적 평가 기준 설정)

  • Kim, Seonyoung
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.695-707
    • /
    • 2016
  • This study presents quantitative evaluation standards for the shape fitness test, conducted in the process of the slacks fit test. This study aims to quantify appearance sensory test of slacks for the objectification of qualitative evaluation methods in existing shape fitness tests. The subjects were women of standard body type between the ages of 18 and 24. Slacks differing in their ease in waist girth, hip girth, crotch length and knee length were designed to test their shape fitness. The gap volume distribution between the body and slack, angle of the baseline by body part, and ratio of total thickness from the sideline using 3D human body scan data (which reflect the results of the appearance sensory test) were presented as quantitative evaluation standards. There were less wrinkles in the wrinkle/overstretch and ease categories of the appearance sensory test; in addition, ease was adequate and small enough to comfortably perform basic human activities in the standing upright posture. The gap volume distribution analysis between body and slacks showed that curves increased in the slacks surface along with an increase of ease in slacks and suggested that wrinkles also increased. In the baseline's horizontal categories in terms of a $0^{\circ}$ horizontal angle, the range of angles were evaluated as adequate by the clothing expert group. The total thickness ratio of 0.5:0.5 divides into the sideline from the baseline.

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection (도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS))

  • Oh, Tong-In;Lee, Min-Hyoung;Kim, Hee-Jin;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

Surface Flattening criterion of Female's Upper Front Shell Using Grid Method (Grid method에 의한 성인 여성 3차원 형상의 상반신 앞판에 대한 평면전개 기준 연구)

  • Choi, Young-Lim;Nam, Yun-Ja;Choi, Kueng-Mi;Cui, Ming-Hai;Han, Sul-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.12
    • /
    • pp.1825-1836
    • /
    • 2008
  • Many applications in computer graphics require complex and highly detailed models. However it is often desirable to use approximations in place of excessively detailed models in order to control the processing time. Thus, we aim to develop a notion of optimal matrix to simplify surface which can rapidly obtain the high quality 2D patterns flattening 3D surface as follows. Firstly, two 3D bodies are modeled based on existing Size Korea data. Secondly, each model is divided by shell and block for its pattern draft. Thirdly, each block is flattened by grid and bridge method. Finally, we selected the optimal matrix and demonstrated the efficiency and quality of the proposed method. This proposed approach accommodates surfaces with darts, which are commonly used in the clothing industry to reduce the deformation of surface forming and flattening. The resulting optimal matrix could be an initiation of standardization for pattern flattening. It is expected that this method could facilitate much better approximation in both efficiency and precision.