• Title/Summary/Keyword: 3D correlation

검색결과 2,586건 처리시간 0.029초

한국 성인의 Vitamin D 영양 상태가 골밀도에 미치는 영향 (The Effect of Vitamin D Status on Bone Mineral Density of Korean)

  • 문수재
    • Journal of Nutrition and Health
    • /
    • 제31권1호
    • /
    • pp.46-61
    • /
    • 1998
  • This study was carried out to evaluate the effects of vitamin D nutritional status on bone mineral density of adults (21-49 years). To attain the aim, we measured bone mineral density (BMD) of the subjects at distal radius by single-photon absorptiometry (SPA). Serum level of 25-hydroxyvitamin D(25-(OH)D) , known to be the best indicator of indicator of vitamin D status in humans was analyzed . The factors affecting this vitamin D level were also investigated in autumn in 122 young adults. Serum level of 25-(OH)D was measured by high pressure liquid chromatography(HPLC) and biochemical variables, general health status, time spent outdoors, and dietary intakes of the subjects. BMD of the male subjects was significantly greater than that of female subjects. Weight, activity and total energy expediture (TEE) showed a positive correlation with distal BMD. The mean level of serum 25-(OH)D was 24.4$\pm$11.0 ng./ml and by sex, 26.0$\pm$6.8ng/ml for males and 23.3$\pm$12.3ng/ml for females , the level was significantly higher in male (p<0.01). there was significant correlation between BMD at distal-radius and s-25(OH)D levels (p<0.001). The serum level fo parathyroid hormone (PTH) showed a negative correlation with BMD(p<0.05), with the more obvious correlation in females. Vitamin D intake was estimated to be 3.75$\pm$2.19ug/day in average. Among the nutrients studied, protein ,fat, calcium , and vitamin D intake were positively correlated with distal BMD. When food frequencies were concerned , milk and dairy products showed a significant positive correlation with the BMD level, and driedfoods, eggs , fats and oils, and cereals also showed a positive correlation. Time spent outdoors was estimated to be about 70 minutes in average and positively correlated with the distal BMD level(p<0.01). During the day, the specific time between 12 :00pm and 2:00pm showed the most significant correlation with BMD (p<0.001). Multiple regression analysis with the variables showed that distal BMD could be fit 31.9% by the time spent outdoors a day, intake of Ca and vitamin D, and TEE. The standardized estimates were 0.344 for vitamin D intake, 0.284 for Ca intake 0.179 for the time spent outdoors a day and 0.273 for TEE. For males, s-25*OH)D level, TEE and time spent outdoors during a day showed a significant correlation. For females, intake of Ca and vitamin D could fit about 27.1% of the distal BMD.

  • PDF

Implementation of 3D Moving Target-Tracking System based on MSE and BPEJTC Algorithms

  • Ko, Jung-Hwan;Lee, Maeng-Ho;Kim, Eun-Soo
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.41-46
    • /
    • 2004
  • In this paper, a new stereo 3D moving-target tracking system using the MSE (mean square error) and BPEJTC (binary phase extraction joint transform correlator) algorithms is proposed. A moving target is extracted from the sequential input stereo image by applying a region-based MSE algorithm following which, the location coordinates of a moving target in each frame are obtained through correlation between the extracted target image and the input stereo image by using the BPEJTC algorithm. Through several experiments performed with 20 frames of the stereo image pair with $640{\times}480$ pixels, we confirmed that the proposed system is capable of tracking a moving target at a relatively low error ratio of 1.29 % on average at real time.

측만증 환자에서 3차원 체표면 영상분석과 Cobb 각의 상관관계 (Correlation of the 3D-Surface Topography and Cobb's Angle in Scoliotic Patient's)

  • 최은정;김태열
    • 대한임상전기생리학회지
    • /
    • 제3권1호
    • /
    • pp.61-70
    • /
    • 2005
  • The purpose of study correlation between 3D-surface topography and Cobb angle in scoliotic patients. It would be recognizing possibility of clinical application with 3D-surface topography with scoliosis assessment and correlation analysis of obtained Cobb angle through measured results of surface topography and took X-ray of subjects with scoliosis, which used to 3D-surface topography of laser scan method. A scoliosis subjects 16(males 4, females 12) agreed for study's purport volunteer our study that diagnose the scoliosis through 3D-surface topography and X-ray. The results were as follow: It was shown that the relation of Cobb angle of scoliosis and itemized 3D-surface topography measurement in horizontal view(p<0.01). top difference of cervicothoracic and lumbar in anterior-posterior view(p<0.05), the top difference of thoracic, thoracolumbar(p<0.01). These results suggest that an itemized 3D-surface topography measurement was highly correlated with Cobb angle. It would be a useful diagnosis method and assessment of physical therapy plan.

  • PDF

Effect of Input Data Video Interval and Input Data Image Similarity on Learning Accuracy in 3D-CNN

  • Kim, Heeil;Chung, Yeongjee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권2호
    • /
    • pp.208-217
    • /
    • 2021
  • 3D-CNN is one of the deep learning techniques for learning time series data. However, these three-dimensional learning can generate many parameters, requiring high performance or having a significant impact on learning speed. We will use these 3D-CNNs to learn hand gesture and find the parameters that showed the highest accuracy, and then analyze how the accuracy of 3D-CNN varies through input data changes without any structural changes in 3D-CNN. First, choose the interval of the input data. This adjusts the ratio of the stop interval to the gesture interval. Secondly, the corresponding interframe mean value is obtained by measuring and normalizing the similarity of images through interclass 2D cross correlation analysis. This experiment demonstrates that changes in input data affect learning accuracy without structural changes in 3D-CNN. In this paper, we proposed two methods for changing input data. Experimental results show that input data can affect the accuracy of the model.

3차원 뉴튼(3D-NEWTON)을 이용한 척추 주위근 기능 평가의 유용성 (The Utility of Measuring Paravertebral Muscle Function with 3D-NEWTON)

  • 한나미;김현동;황지선;배중혁
    • The Journal of Korean Physical Therapy
    • /
    • 제25권1호
    • /
    • pp.16-22
    • /
    • 2013
  • Purpose: This study evaluated the validity of measuring paravertebral muscle function with 3D-NEWTON (Hanmed, Korea) by assessing the correlation between Biodex (Biodex, USA) and surface electromyography (EMG). Methods: Nineteen healthy adults participated. The function of their paravertebral muscle was measured in three ways. Maximum endurance time was measured in seconds when 3D-NEWTON was inclined forward for assessing extensor function, and inclined backward for assessing flexor function. Using surface EMG, maximum muscle activity was obtained from the eractor spinae and rectus abdominis during the 3D-NEWTON measurement. Maximum muscle activity was the mean activity from 10 seconds when the root mean squared firing data was highest. Through Biodex the peak torques of the extensor and flexor were measured during isometric exercises. The Spearman correlation coefficiencts from 3D-NEWTON, surface EMG, and Biodex were calculated. Results: The data from surface EMG and Biodex were statistically correlated when measured for flexor function, but less so for extensor function. In the case of 3D-NEWTON, the correlation coefficient with Biodex was 0.50 (p=0.05), while the coefficient with surface EMG was 0.53 (p=0.02) when measured for extensor function. Similarly, the correlation coefficienct with Biodex was 0.60 (p=0.01), while the surface EMG was 0.51 (p=0.03) for flexor function. Conclusion: 3D-NEWTON was a useful method for measuring paravertebral muscle function and can give helpful information for treating people with diseases associated with the lumbar spine.

Correlation between the 2-Dimensional Extent of Orbital Defects and the 3-Dimensional Volume of Herniated Orbital Content in Patients with Isolated Orbital Wall Fractures

  • Cha, Jong Hyun;Moon, Myeong Ho;Lee, Yong Hae;Koh, In Chang;Kim, Kyu Nam;Kim, Chang Gyun;Kim, Hoon
    • Archives of Plastic Surgery
    • /
    • 제44권1호
    • /
    • pp.26-33
    • /
    • 2017
  • Background The purpose of this study was to assess the correlation between the 2-dimensional (2D) extent of orbital defects and the 3-dimensional (3D) volume of herniated orbital content in patients with an orbital wall fracture. Methods This retrospective study was based on the medical records and radiologic data of 60 patients from January 2014 to June 2016 for a unilateral isolated orbital wall fracture. They were classified into 2 groups depending on whether the fracture involved the inferior wall (group I, n=30) or the medial wall (group M, n=30). The 2D area of the orbital defect was calculated using the conventional formula. The 2D extent of the orbital defect and the 3D volume of herniated orbital content were measured with 3D image processing software. Statistical analysis was performed to evaluate the correlations between the 2D and 3D parameters. Results Varying degrees of positive correlation were found between the 2D extent of the orbital defects and the 3D herniated orbital volume in both groups (Pearson correlation coefficient, 0.568-0.788; $R^2=32.2%-62.1%$). Conclusions Both the calculated and measured 2D extent of the orbital defects showed a positive correlation with the 3D herniated orbital volume in orbital wall fractures. However, a relatively large volume of herniation (>$0.9cm^3$) occurred not infrequently despite the presence of a small orbital defect (<$1.9cm^2$). Therefore, estimating the 3D volume of the herniated content in addition to the 2D orbital defect would be helpful for determining whether surgery is indicated and ensuring adequate surgical outcomes.

고속 컴퓨터 집적 영상 복원 방법을 이용한 비선형 3D 영상 상관기 (Nonlinear 3D Image Correlator Using Fast Computational Integral Imaging Reconstruction Method)

  • 신동학;이준재
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2280-2286
    • /
    • 2012
  • 본 논문에서는 고속 컴퓨터 집적 영상 복원 방법을 이용하여 새로운 형태의 3D 비선형 상관기를 제안한다. 고속 컴퓨터 집적 영상 복원 방법을 구현하기 위해서 기존의 방법에서 확대 과정을 제거함으로서 고속 계산이 가능하다. 제안하는 상관기는 먼저 기준 물체와 목표 물체의 요소 영상들을 렌즈 배열을 통해 픽업한다. 이 픽업된 영상에 고속 컴퓨터 집적 영상 복원 방법을 사용하여 목표 평면 영상과 기준 평면 영상들이 복원된다. 복원된 기준 평면 영상과 목표 평면 영상들 간의 비선형 상호상관을 통해 인식을 수행한다. 비선형 상관 연산의 사용은 상관기의 3D 물체 인식 성능 향상시킬 수 있다. 제안된 방법의 유용함을 보이기 위해 기존의 방법과 비교하여 기초적인 상관관계 실험을 수행하고 그 결과를 보고한다.

3D 가상패션소재의 드레이프성 연구 - 3D 의상 CAD 시스템 활용 - (A Study on the Drape Profile Analysis of the Apparel Textiles and 3D Virtual Textiles using a 3D Digital Clothing Software)

  • 이윤주;김종준
    • 패션비즈니스
    • /
    • 제15권5호
    • /
    • pp.103-114
    • /
    • 2011
  • During a wearer's movement, the apparel fabric layers collide each other in a highly complicated manner. The collision involves cloth-cloth, and cloth-body collision. The diversity of the textile fabrics, including silk, wool, cotton, and other synthetic fibers, together with the complex details of the apparel construction, makes the collision and other calculation procedure involved in the 3-dimensional clothing software system much more complicated. Therefore, there is a need to measure the behavior of the fabrics during the fabric collision cycles. In this study, as a first step, static measurements pertinent to the factors governing the appearance of the apparel fabrics were implemented. The drape profile, stiffness(Sd and Sf), tensile properties, thickness, and the air permeability were measured. The correlation between the parameters were calculated and reviewed. It is found that there is a high correlation of 0.97 between the actual fabric drape parameters and the 3D virtual fabric drape parameters. The measured drape coefficients of the fabrics show relatively good correlation with the measured fabric stiffness.

Three-Dimensional Phase-Only Holographic Correlation

  • Kim, Tae-Geun
    • Journal of the Optical Society of Korea
    • /
    • 제5권3호
    • /
    • pp.99-109
    • /
    • 2001
  • This paper presents a phase-only modulation scheme for a three-dimensional (3-D) image matching system to improve optical efficiency of the system. The 3-D image matching system is based on the two mask heterodyne scanning. A hologram of the 3-D reference object is first created and then the phase of the hologram is extracted. The phase of the hologram is represented as one mask with the other mask being a plane wave. The superposition of each beam modulated by the two masks generated a scanning beam pattern. This beam pattern scans the 3-D target object to be recognized. The output of the scanning system gives out the correlation of the phase-only hologram of the reference object and the complex hologram of the target object. Since a hologram contains 3-D information of an object as a form of fringe pattern, the correlation of holograms matches whole 3-D aspect of the objects. Computer simulations are performed with additive gaussian noise and without noise for the complex hologram modulation scheme and the phase-only hologram modulation scheme. The computer simulation results show that the phase-only hologram modulation scheme improves the optical efficiency. Thus the system with the phase-only hologram modulation scheme is more robust than the system with the complex hologram modulation scheme.

Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

  • Kim, Mock Ryeon;Park, Hye Won;Son, Jae Sung;Lee, Ran;Bae, Sun Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제19권3호
    • /
    • pp.186-192
    • /
    • 2016
  • Purpose: To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods: Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results: The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was $0.68{\pm}0.18g/kg/d$; according to age, the dose was $0.73{\pm}0.16g/kg/d$ (<8 years), $0.53{\pm}0.12g/kg/d$ (8 to <12 years), and $0.36{\pm}0.05g/kg/d$ (12 to 15 years). The dose of lactulose was $1.99{\pm}0.43mL/kg/d$ (<8 years) or $1.26{\pm}0.25mL/kg/d$ (8 to <12 years). There was no significant correlation between CTT test value and initial dose of laxative, irrespective of the subgroup (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion: CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation.