The Comparison Evaluation of SUV Using Different CT Devices in PET/CT Scans (PET 검사에서 CT 장비의 차이에 따른 PET/CT의 SUV 비교 평가)

  • Kim, Woo Hyun;Go, Hyeon Soo;Lee, Jeong Eun;Kim, Ho Sung;Ryu, Jae Kwang;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Purpose: Among different PET/CT devices which are composed of same PET model but different CT models, SUV, usually used for quantitative evaluation, was measured to assess the accuracy of follow up scans in different PET/CT and confirm that interequipment compatibility is useful in arranging the PET/CT exam appointment. Materials and Methods: Using ACR PET Phantom, PET NEMA IEC Body Phantom, SNM Chest Phantom and Ge-68 cylinder Phantom, $SUV_{mean}$ and $SUV_{max}$ was measured by 3 different models of PET/CT (Discovery 690, Discovery 690Elite and Discovery 710, GE) made in same company. ANOVA was used to evaluate the significant difference in the result. Results: In the result, the average of $SUV_{max}$ was D690 (25 mm-1.82, 16 mm-1.75, 12 mm-1.73, 8 mm-1.44), D690E (25 mm-1.76, 16 mm-1.92, 12 mm-1.78, 8 mm-1.55) and D710 (25 mm-1.84, 16 mm-1.89, 12 mm-1.77, 8 mm-1.61) in ACR Phantom, D690 (25 mm-2.26, 16 mm-2.25, 12 mm-1.92, 8 mm-1.85), D690E (25 mm-2.45, 16 mm-2.25, 12 mm-2.05 8 mm-1.91) and D710(25 mm-2.49, 16 mm-2.20, 1 2mm-2.30, 8 mm-2.05) in PET NEMA IEC Body Phantom, D690-1.04, D690E-1.10 and D710-1.09 in SNM Chest Phantom and D690-0.81, D690E-0.81, D710-0.84 in Ge-68 cylinder Phantom. The differences between average SUV of 4 phantoms were $SUV_{mean}$-1.87%, $SUV_{max}$-2.15%. And also as a result of ANOVA analysis, there was no significant difference statistically. Conclusion: If different models of PET/CT have same specification of PET system, there was no significant difference in $SUV_{mean}$ and $SUV_{max}$ even though they have different CT system. And also differences of $SUV_{mean}$ and $SUV_{max}$ in phantom images were under 5% which many manufacturers recommend. Therefore, follow up scan will be possible using different PET/CT if it has same specification of PET system with the previous PET/CT. This information will enable the accurate comparative analysis when conducting follow up scans and be helpful to schedule PET/CT exam more effectively.

  • PDF

Discrimination of Lateral Torso Types by Posture for Older Women (노년 여성의 몸통 측면 자세에 따른 체형 판별)

  • Sunmi Park;Hyunsook Han
    • Fashion & Textile Research Journal
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2024
  • This study aimed to objectively classify the lateral torso posture types and functions of older women. We used 3D body scan data of 119 women aged 70-85 years from the 6th SizeKorea project. First, we defined three torso axes to represent the lateral torso posture types: posterior waist-back, back-cervical, and whole torso axes. Next, we asked experts to select one of four lateral torso posture types-stooped, straight, leaning back, and swayback postures-by looking at the lateral photographic data of 119 older women. To identify the axis that best represented each lateral torso posture type, a discriminant analysis was conducted using the angle of each of the three torso axes as an independent variable and an expert's visual classification as a dependent variable. Based on the analysis, the whole torso and backcervical axis angles were selected as variables for judging lateral torso posture types. Subsequently, we developed a classification function to determine which of the four lateral torso posture types of a particular participant was applicable for a new individual. The method developed in this study is significant in that it enables the objective classification of the lateral torso postures types of older women.

A Development of Slacks Patterns for the Abdomen-obese Middle-aged Males from a Virtual Garment Simulation (가상 착의 시스템에 의한 복부 비만 중년 남성의 슬랙스 원형 개발)

  • Lim, Ji-Young
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.5
    • /
    • pp.1009-1018
    • /
    • 2011
  • The purpose of this study was to develop slacks patterns for middle-aged abdomen-obese adult males by using the 3D virtual-twin and virtual-garment simulation system. The criteria for subjects in this study were males who had over $25kg/m^2$ of BMI, over 90cm of waist, and over 0.90 of WHR. A total of 211 adult males who met these criteria were enrolled. The results were as follows: first, a new slacks pattern considerate of abdomen-obese men was development. The basic numerical formula were as follows: front and back hip girth H/4+3.5, front waist girth W/4+1+0.5, back waist girth W/4+1-0.5, front crotch extension H/16, back crotch extension H/8-0.5, front pleats amount 2.7, and back dart amount 1.5. Second, according to the results of the new slacks patterns appearance evaluation, the new slacks pattern scored more highly than the existing pattern in silhouette and ease amount, confirming that the new slacks pattern is appropriate for the abdomen-obese men. Also, the new slacks pattern was evaluated allowing proper space length of waist, abdomen and hip. Virtual models of production through data from a 3D body scan, pattern draft and virtual garment digital program were applied to a prototypic design method in order to enhance the fitness of ready-made garments. The use of the virtual twin made it impossible to comprehend the appearances and ease correspondent to motions. In order to evaluate wearing fitness, therefore, the system should be improved so as to change arm positions and perform various motions.

Development of robot calibration method based on 3D laser scanning system for Off-Line Programming (오프라인 프로그래밍을 위한 3차원 레이저 스캐닝 시스템 기반의 로봇 캘리브레이션 방법 개발)

  • Kim, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.16-22
    • /
    • 2019
  • Off-line programming and robot calibration through simulation are essential when setting up a robot in a robot automation production line. In this study, we developed a new robot calibration method to match the CAD data of the production line with the measurement data on the site using 3D scanner. The proposed method calibrates the robot using 3D point cloud data through Iterative Closest Point algorithm. Registration is performed in three steps. First, vertices connected by three planes are extracted from CAD data as feature points for registration. Three planes are reconstructed from the scan point data located around the extracted feature points to generate corresponding feature points. Finally, the transformation matrix is calculated by minimizing the distance between the feature points extracted through the ICP algorithm. As a result of applying the software to the automobile welding robot installation, the proposed method can calibrate the required accuracy to within 1.5mm and effectively shorten the set-up time, which took 5 hours per robot unit, to within 40 minutes. By using the developed system, it is possible to shorten the OLP working time of the car body assembly line, shorten the precision teaching time of the robot, improve the quality of the produced product and minimize the defect rate.

Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors (삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가)

  • Park, Myung-Hwan;Lee, Jin-Wan;Lee, Kang-Won;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • Purpose : A parallel imaging method provides us to improve temporal resolution to obtain three-dimensional (3D) MR images. The objective of this study was to optimize three 3D MRI techniques by adjusting 2D SESNE factors of the parallel imaging method in phantom and human brain. Materials and Methods : With a 3 Tesla MRI system and an 8-channel phase-array sensitivity-encoding (SENSE) coil, three 3D MRI techniques of 3D T1-weighted imaging (3D T1WI), 3D T2-weighted imaging (3D T2WI) and 3D fluid attenuated inversion recovery (3D FLAIR) imaging were optimized with adjusting SESNE factors in a water phantom and three human brains. The 2D SENSE factor was applied on the phase-encoding and the slice-encoding directions. Signal-to-noise ratio(SNR), percent signal reduction rate(%R), and contrast-to-noise ratio(CNR) were calculated by using signal intensities obtained in specific regions-of-interest (ROI). Results : In the phantom study, SENSE factor = 3 was provided in 0.2% reduction of signals against without using SENSE with imaging within 5 minutes for 3D T1WI. SENSE factor = 2 was provided in 0.98% signal reduction against without using SENSE with imaging within 5 minutes for 3D T2WI. SENSE factor = 4 was provided in 0.2% signal reduction against without using SENSE with imaging around 6 minutes for 3D FLAIR. In the human brain study, SNR and CNR were higher with SENSE factors = 3 than 4 for all three imaging techniques. Conclusion : This study was performed to optimize 2D SENSE factors in the three 3D MRI techniques that can be scanned in clinical time limitations with minimizing SNR reductions. Without compromising SNR and CNR, the optimum 2D SENSE factors were 3 and 4, yielding the scan time of about 5 to 6 minutes. Further studies are necessary to optimize 3D MRI techniques in other areas in human body.

  • PDF

Effects of supplementing limiting amino acids on milk production in dairy cows consuming a corn grain and soybean meal-based diet

  • Park, Joong Kook;Yeo, Joon-Mo;Bae, Gui-Seck;Kim, Eun Joong;Kim, Chang-Hyun
    • Journal of Animal Science and Technology
    • /
    • v.62 no.4
    • /
    • pp.485-494
    • /
    • 2020
  • Limiting amino acids (AAs) for milk production in dairy cows fed on a concentrate diet of corn grain and soybean meal was evaluated in this study. Four lactating and multiparous Holstein cows (in third or fourth parities, with an average body weight of 633 ± 49.2 kg), 8 to 9 weeks into their lactation period, were used in a 4 × 4 Latin square design. The experiment comprised four dietary treatments: (1) no intravenous infusion (control); (2) control plus intravenous infusion of an AA mixture of 6 g/d methionine, 19.1 g/d lysine, 13.8 g/d isoleucine, and 15.4 g/d valine (4AA); (3) control plus intravenous infusion of the AA mixture without methionine (no-Met); and (4) control plus intravenous infusion of the AA mixture without lysine (no-Lys). All animals were fed on a controlled diet (1 kg/d alfalfa hay, 10 kg/d silage, 14 kg/d concentrate mixture, ad libitum timothy hay). The AA composition of the diet and blood were determined using an automatic AA analyzer. Milk composition (protein, fat, lactose, urea nitrogen, and somatic cell counts) was determined using a MilkoScan. The results showed that feed intake for milk production did not differ from that of intravenous infusion using a limiting AA mixture. The 4AA treatment numerically had the highest milk yield (32.4 kg/d), although there was no difference when compared with the control (31.2 kg/d), no-Met (31.3 kg/d), and no-Lys (31.7 kg/d) treatments. The concentration of AAs in blood plasma of cows in all treatments, mainly isoleucine and valine, increased significantly compared with that of control. The no-Met treatment increased (p < 0.05) the concentration of lysine in the blood relative to the control and no-Lys treatments, whereas the no-Lys treatment increased (p < 0.05) the concentration of methionine relative to the control and no-Met treatments. In conclusion, milk production increased when feeding 10 g/d methionine to the cows, together with their concentrate diet of corn grain and soybean meal.

Osteoporotic Vertebral Compression Fracture Associated with Pregnancy and Lactation in Young Women (젊은 여성에서 임신 및 수유와 연관된 골다공증성 척추 압박골절)

  • Shin, Woo-Jin;Suh, Seung-Pyo;Yeom, Ji-Ung;Kim, Yun-Seong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.266-271
    • /
    • 2021
  • Osteoporosis associated with pregnancy and lactation is a rare disease that can cause osteoporotic vertebral compression fracture (OVCF). Patients usually complain of severe back pain, which is easily mistaken for pain due to pregnancy, childbirth, and lactation, making a rapid diagnosis and treatment difficult. The authors diagnosed OVCF related to pregnancy and lactation through a physical examination, simple radiography, whole-body bone scan, magnetic resonance image, bone marrow density, and blood tests in a 29-year-old female patient and a 31-year-old female patient who presented with low back pain. This paper reports two cases of symptom improvement through a teriparatide injection, wearing thoracic lumbar sacral orthosis and taking calcium and vitamin D with a review of the literature.

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF