• Title/Summary/Keyword: 3D body scan

Search Result 189, Processing Time 0.027 seconds

Basic Study on the Image Instrument of the Facial-form by the 3D-facial Scanner (얼굴스캐너를 활용한 안면형상 영상진단기의 기초 연구)

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Kim, Hoon;Shin, Soon-Shik;Lee, Hai-Woong;Lee, Yong-Tae;Chi, Gyoo-Yong;Kim, Jong-Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.497-501
    • /
    • 2008
  • 3D facial scanner for an accurate analysis is measured precisely a distance in straight, a distance in curved line, an angle in 3D data, the area of surface. We can easy acquire 3D data by the method of 0.8sec in each scan with easy handling, simple merge to whole face, harmless and fast process. In the HyungSang medicine, the inspection of the facial shape includes the Dam(gall bladder) - Bang Kwang(urinary bladder) body, the Jung${\cdot}$Gi${\cdot}$Shin${\cdot}$Hyul, the six merdian types etc. And we will collect the evidence based date verifing in the HyungSang clinical medicine. As we will analyze the facial whole form and the size${\cdot}$length${\cdot}$angle of the facial part, put the facial form's standardization on a solid foundation.

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

Development of a Sizing System of Women's Fitness Wear for the Senior Population in South Korea (한국 노인 여성을 위한 피트니스 압박웨어 치수 개발)

  • Jeon, Eun-Jin;Lee, Won-sup;Park, Jang-Woon;You, Hee-Cheon
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.464-473
    • /
    • 2018
  • The objective of this study is to develop a sizing system of fitness clothing that can properly accommodate various body sizes of Korean senior women. The sizing system of upper and lower fitness clothing was developed in the present study by selection of key variables, identification of size category candidates, and determination of an optimal sizing system. First, key anthropometric dimensions (stature and bust circumference for upper clothing and stature; waist circumference for lower clothing) were identified by factor analysis on the direct body measurements (n = 272) and 3D whole-body scan data (n = 271) of Korean senior women in Size Korea. Second, sizing system candidates based on the key dimensions of upper and lower clothing were explored using a grid method and an optimization method. Lastly, among the sizing system candidates, optimal sizing systems of upper and lower clothing were selected in terms of accommodation rate. Five size categories (short/small, short/medium, tall/small, tall/medium, and tall/large) were selected as the optimal sizing systems of upper and lower clothing with 89% and 78% of accommodation rate, respectively, for the Korean senior women. The anthropometric characteristics of the representative humans of the optimal size categories would be of use in the design of fitness compressive wear for the better fit and effectiveness of exercise and health of Korean senior women.

Design of 3D compression upper wear based on skin deformation during arm abduction (팔 외전 시 몸통의 피부 변화량 분석과 이를 활용한 3D 컴프레션 상의 설계)

  • Kim, Nam Yim;Wu, Yan Jun;Hong, Kyunghi
    • Korean Journal of Human Ecology
    • /
    • v.24 no.5
    • /
    • pp.687-700
    • /
    • 2015
  • Lines of non-extension (LoNEs) on torso surface during arm abduction were investigated to provide appropriate location for inserting less-extensible yarns which can be used as seams for design and or clothing pressure variation. As experimental methods, reference points about 3 cm apart were marked on the skin and scanned at 30, $90^{\circ}$ and $135^{\circ}$ arm abduction. Skin deformation was measured by connecting reference points in horizontal, vertical and various angles of diagonal directions. Observation of skin deformation was made within the separated sections of the torso as well as integrated ones to cover the various occasions of design application. LoNEs of front and back torso were provided as mapping lines. Actual compression wear of three types was constructed with different pattern reduction rate at each separated section using LoNEs as boundary cutting lines. Clothing pressure and subjective evaluations of those three compression wear were evaluated by six subjects. LoNEs found in this study were useful as seam lines to differentiate clothing pressure at each part of the body, providing positive wear sensation. It is also expected that LoNEs can be paths for less strechable conductive yarns of IT-integrated upper garments.

Classification of Head Shape and 3-dimensional analysis for Korean Men (성인 남성 머리와 얼굴 부위의 형태분류와 3차원적 분석)

  • Choi, Young-Lim;Kim, Jae-Seung;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.12 no.6
    • /
    • pp.812-820
    • /
    • 2010
  • The objectives of this study were to classify the head shapes of Korean men and to suggest computer tomography as a new body measurement method. The 23 head measurement items of 760 men, aged more than 18 in Sizekorea 2004 database were used to analyze, measured by using statistical methods. Factor analysis, cluster analysis and duncan test were performed using these data. Through factor analysis, 5 factors were extracted upon factor scores and those factors comprised 70.91% for the total variances. The head and face shapes were categorized as 5 types-triangle, round, oval, long, rectangle. We decided for the type 1(triangle) to standard head shape since this type was the most observed. 21 participants were measured using computed tomography(CT). The measured data of skin and skeleton and the standard head shapes were illustrated.

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

A Study on Split Grading Methods for Women's Pants and Increase Rate of Body Size of Adult Women (성인 여성의 연령대별 인체 부위 간 치수증감률을 반영한 바지 그레이딩에 관한 연구)

  • Baek, Rise;Song, Hwa Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.6
    • /
    • pp.877-890
    • /
    • 2019
  • This study investigated the location of grading lines and grading amount defined by 17 women's wear brands for a pants item by target age groups (20-30, 30-40, and 40-50). This study utilized 6th Size Korea data and a script-based on a 3D scan measurement program to analyze the increase rate of body size in order to suggest a grading deviation distribution ratio for the pants using regression analysis. This study found that most brands appropriately divided grading amount at front thigh girth and back hip girth into the side and center by 1:1. Most brands divided the grading amount at the front hip girth into the side and center by 1:1; however, the ratio found from Size Korea is 0.8:1.2 for the 20-30 age group, 0.7:1.3 for the 30-40 age group, and 0.6:1.4 for the 40-50 age group. Regarding the back thigh girth, the brands targeting 20-30s, 30-40s, and 40-50s respectively assigned the grading amount into the side and center by 1:1, 1:1.2, and 1:1.3. However, the ratio found from Size Korea is 1.4:0.6 for the 20-30 age group, 1.7:0.3 for the 30-40 age group, and 1.3:0.7 for the 40-50 age group. The results can be utilized in improving the grading system of the pants item.

Macronutrient composition of human milk from Korean mothers of full term infants born at 37-42 gestational weeks

  • Chang, Namsoo;Jung, Ji A;Kim, Hyesook;Jo, Ara;Kang, Sujeong;Lee, Si-Won;Yi, Hyunju;Kim, Jihee;Yim, Jong-Gap;Jung, Byung-Moon
    • Nutrition Research and Practice
    • /
    • v.9 no.4
    • /
    • pp.433-438
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: Breast milk is the best available food for optimum growth and development of infants and the breastfeeding rate is increasing in Korea. The purpose of this study is to measure the concentrations of macronutrients and to evaluate their changes according to lactation period in breast milk from lactating Korean women. SUBJECTS/METHODS: Milk samples were obtained from 2,632 healthy lactating women (mean age; $32.0{\pm}3.3years$), where the lactating period was up to a period of 8 months, who also volunteered to participate in the Human Milk Macronutrient Analysis Research. Lactose, protein, fat and water content in the breast milk samples were analyzed with infrared spectrometry using MilkoScan FT-2. RESULTS: The mean macronutrient composition per 100 mL of mature breast milk was 7.1 g for lactose, 1.4 g for protein and 3.0 g for fat, and energy content was 61.1 kcal. The protein concentration was significantly lower in milk samples at 1-2 weeks (2.0 g/dL) to 2-3 months (1.4 g/dL) than those at 0-1 week (2.2 g/dL), but it was similar among samples from 3-4 months to 7-8 months (1.3 g/dL). Mean lipid levels varied among different lactational period groups (2.7-3.2 g/dL), but presented no significant difference. Lactose concentration in the milk samples did not differ with lactation period. Maternal body mass index was positively related to protein and lipid breast milk contents, but was negatively related to lactose content. General linear models examining the associations between maternal variables and milk macronutrient content revealed that lactation period had a major impact on protein and lipid, but not on lactose content in breast milk. CONCLUSIONS: These results warrant future studies to explore factors that may be associated with changes in macronutrient content in human milk.

Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy (전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가)

  • Ahn, Ki-Song;Jung, Woo-Chan;Kim, Dae-Hyun;Kim, Moo-Sub;Yoon, Do-Kun;Shim, Jae-Goo;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.