• 제목/요약/키워드: 3D Structural Analysis

검색결과 1,458건 처리시간 0.031초

레이저 열-압착 본딩 시스템의 Lateral Force 감소를 위한 유연 힌지의 설계 (Design of flexure hinge to reduce lateral force of laser assisted thermo-compression bonding system)

  • 이동원;하석재;박정연;윤길상
    • Design & Manufacturing
    • /
    • 제14권3호
    • /
    • pp.23-30
    • /
    • 2020
  • Laser Assisted Thermo-Compression Bonding (LATCB) has been proposed to improve the "chip tilt due to the difference in solder bump height" that occurs during the conventional semiconductor chip bonding process. The bonding module of the LATCB system has used a piezoelectric actuator to control the inclination of the compression jig on a micro scale, and the piezoelectric actuator has been directly coupled to the compression jig to minimize the assembly tolerance of the compression jig. However, this structure generates a lateral force in the piezoelectric actuator when the compression jig is tilted, and the stacked piezoelectric element vulnerable to the lateral force has a risk of failure. In this paper, the optimal design of the flexure hinge was performed to minimize the lateral force generated in the piezoelectric actuator when the compression jig is tilted by using the displacement difference of the piezoelectric actuator in the bonding module for LATCB. The design variables of the flexure hinge were defined as the hinge height, the minimum diameter, and the notch radius. And the effect of the change of each variable on the stress generated in the flexible hinge and the lateral force acting on the piezoelectric actuator was analyzed. Also, optimization was carried out using commercial structural analysis software. As a result, when the displacement difference between the piezoelectric actuators is the maximum (90um), the maximum stress generated in the flexible hinge is 11.5% of the elastic limit of the hinge material, and the lateral force acting on the piezoelectric actuator is less than 1N.

발사체 연소기용 산화제 개폐밸브의 핵심요소 기술 개발 (Study for the Development of a Main Oxidizer Shut-off Valve for Liquid Rocket Engines)

  • 김도형;홍문근;박재성;이수용
    • 한국추진공학회지
    • /
    • 제17권6호
    • /
    • pp.113-119
    • /
    • 2013
  • 발사체 연소기용 산화제 개폐밸브는 비교적 간단한 개폐 작동을 통해, 액체산소를 연소기에 공급 또는 차단한다. 고압, 고유량, 극저온의 액체산소를 운용 유체로 사용할 뿐만 아니라, 설계유량 대비 밸브 차압 또한 낮아야 하는 상당히 까다로운 개발요구조건을 가지고 있다. 본 논문에서는 현재 개발 중인 연소기용 산화제 개폐밸브의 밸브 과도 응답과 같은 기본적인 밸브 특성과 함께, 밸브 성능을 좌우하는 핵심 부분이라고 할 수 있는 밸브 공압 구동부 및 포핏/시트부의 개발 내용을 소개하였다. 밸브의 과도 응답 특성 해석 결과가 시험 측정결과와 매우 잘 일치하는 것을 확인하였으며, 구동 공압부 및 포핏/시트부 구조해석을 통해 밸브 무빙파트의 접촉면 반발력과 마찰력을 정량적으로 평가하였다.

3차원 영상분석을 활용한 석탑의 해체와 재조립 : 심곡사칠층석탑 사례 연구 (Disassembly and Reconstruction of Stone Pagoda Using 3-Dimensional Image Analysis : Case Study in Simgoksa Seven-storied Stone Pagoda)

  • 최희수;이찬희;한성희;이성민
    • 보존과학회지
    • /
    • 제32권4호
    • /
    • pp.561-570
    • /
    • 2016
  • 이 연구는 심곡사칠층석탑의 해체와 재조립에 3차원 영상분석 기법을 적용하여 원형에 가깝게 보수한 기술적 사례로써 의미가 있다. 석탑의 해체와 재조립 과정에서 전체적인 변형상태와 변위를 분석하였으며 구조적 안정성 검토를 통하여 재조립에 따른 변형을 최소화하였다. 또한 석탑의 원위치도 재검토하여 보수에 적용하였다. 재조립에 앞서 오염된 석재의 표면은 과학적 표면세정을 통해 이끼류와 지의류 등을 제거하였고, 석탑의 지반은 강회를 이용한 판축과 유사한 형식으로 다짐하여 보강하였다. 이 결과는 석탑의 해체와 재조립 과정에 중요한 자료로 활용될 수 있을 것이다.

교차가새형 선행 안전난간을 적용한 시스템비계의 구조 성능 평가 (Structural Capacity Evaluation of System Scaffolding using X-Type Advanced Guardrail)

  • 박주동;이현섭;신우승;권용준;박순응;양승수;정기효
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.49-58
    • /
    • 2020
  • In domestic construction sites, when installing steel pipe scaffolding and system scaffolding, the guardrails are installed after the installation of the work platforms. This conventional guardrail system (CGS) is always exposed to the risk of falls because the safety railing is installed later. In order to prevent fall disasters during erecting and dismantling scaffolds, it is necessary to introduce the advanced guardrail system (AGS) which installs railings in advance of climbing onto a work platform. For the introduction of the AGS, the structural performance of the system scaffolding applying the CGS and the AGS was compared and evaluated. The structural analysis of the system scaffold (height: 31 m and width: 27.4 m) with AGS confirmed that structural safety was ensured because the maximum stress of each element of the system scaffolding satisfies the allowable stress of each element. As a result of performance comparison of CGS and AGS for each element, the combined stress ratio of vertical posts in AGS was 6.4% lower than that of CGS. In addition, in the case of ledger and transom, the combined stress ratios of AGS and CGS were almost the same. The compression test of the assembled system scaffolding (three-storied, 1 bay) showed that the AGS had better performance than the CGS by 9.7% (8.91 kN). The cross bracing exceeds the limit on slenderness ratio of codes for structural steel design. But the safety factor for the compressive load of the cross bracing was evaluated as meeting the design criteria by securing 3 or more. In actual experiments, it was confirmed that brace buckling did not occur even though the overall scaffold was buckled. Therefore, in the case of temporary structures, it was proposed to revise the standards for limiting on slenderness ratio of secondary or auxiliary elements to recommendations. This study can be used as basic data for the introduction of AGS for installing guardrails in advance at domestic construction sites.

IGRINS : Collimating Mirror Mount Opto-mechanical Design

  • Rukdee, Surangkhana;Park, Chan;Chun, Moo-Young;Yuk, In-Soo;Lee, Sung-Ho;Lee, Han-Shin;Kim, Kang-Min;Jeong, Hwa-Kyung;Strubhar, Joseph;Jaffe, Daniel T.
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2011년도 한국우주과학회보 제20권1호
    • /
    • pp.30.4-31
    • /
    • 2011
  • The Korea Astronomy and Space Science Institute (KASI) and the Department of Astronomy at the University of Texas at Austin (UT) are developing a near infrared wide-band high resolution spectrograph, IGRINS (Immersion Grating Infrared Spectrograph). The white-pupil design of the instrument optics uses 7 cryogenic mirrors including 3 aspherical off-axis collimators and 4 flat fold mirrors. Two of the 3 collimators are H- and K-band pupil transfer mirrors and they are designed as compensators for the system alignment in each channel. Therefore, their mount design will be one of the most sensitive parts in the IGRINS optomechanical system. The design work will include the computer-aided 3D modeling and finite element analysis (FEA) to optimize the structural stability of the mount models. The mount body will also include a tip-tilt and translation adjustment mechanism to be used as the alignment compensators.

  • PDF

사람 티로시나제의 3차원 구조 상동 모델링 (Comparative modeling of human tyrosinase - An important target for developing skin whitening agents)

  • 최종근;서주원
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2012년도 춘계학술논문집 1부
    • /
    • pp.182-186
    • /
    • 2012
  • human tyrosinase (hTyr) catalyzes first and the rate limiting step in the synthesis of polymerized pigment, melanin which determines skin, hair and eye colors. Mutation of hTyr often brings about decrease of melanin production and further albinism. Meanwhile, a number of cosmetic companies providing skincare products for woman in Asia-Pacific region have tried to develop inhibitors to bright skin color for several decades. In this study, we built a 3D structure by comparative modeling technique based on the crystal structure of tyrosinase from bacillus megaterium as a template to serve structural information of hTyr. According to our model and sequence analysis of type 3 copper protein family proteins, two copper atoms of active site located deep inside are coordinated with six strictly conserved histidine residues coming from four-helix-bundle. Cavity which accommodates substrates was like funnel shape of which entrance was wide and expose to solvent. In addition, protein-substrate and protein-inhibitor complex were modeled with the guide of van der waals surface generated by in house software. Our model suggested that only phenol group or its analogs can fill the binding site near nuclear copper center because inside of binding site has narrow shape relatively. In conclusion, the results of this study may provide helpful information for designing and screening new anti-melanogensis agents.

  • PDF

충격압분공정으로 제조된 나노 니켈/알루미늄 혼합분말재의 특성 평가 (Evaluation of the Reactivity of Bulk Nano Ni/Al Powder Manufactured by Shock Compaction Process)

  • 김우열;안동현;박이주;김형섭
    • 소성∙가공
    • /
    • 제26권4호
    • /
    • pp.216-221
    • /
    • 2017
  • Recently, interest in multifunctional energetic structural materials (MESMs) has grown due to their multifunctional potential, especially in military applications. However, there are few studies about extrinsic factors that govern the reactivity of MESMs. In this paper, a shock compaction process was performed on the nano Ni/Al-mixed powder to investigate the effect of particle size on the shock reaction condition. Additionally, heating the statically compacted specimen was also performed to compare the mechanical properties and microstructure between reacted and unreacted material. The results show that the agglomerated structure of nanopowders interrupts the reaction by reducing the elemental boundary. X-ray diffraction analysis shows that the NiAl and $Ni_3Al$ intermetallics are formed on the reacted specimen. The microhardness results show that the $Ni_3Al$ phase has a higher hardness than NiAl, but the portion of $Ni_3Al$ in the reacted specimen is minor. In conclusion, using Ni/Al composites as a reactive material should focus on energetic use.

$C^{\ast}$-적분에 기초한 고온배관 수명평가 ([ $C^{\ast}$ ]-integral Based Life Assessment of High Temperature Pipes)

  • 이형일
    • 한국가스학회지
    • /
    • 제4권4호
    • /
    • pp.25-33
    • /
    • 2000
  • 최근 들어 가혹한 온도 및 압력조건에서 운전이 요구되는 고온배관들의 잔여수명예측은 상당히 중요한 관심사로 부각되고 있다. 이에 고온손상을 정량적으로 평가하여 설비를 안전하게 사용하기 위한 유지기술 및 수명평가 기술을 확보하는 것은 매우 중요하다. 한편 이러한 고온배관내 대부분의 균열은 반타원 표면균열의 형태로 형상화되어 파괴역학의 실제응용에서 발견할 수 있는 가장 복잡한 형상과 하중특성을 갖게 된다. 이를 배경으로 본 연구에서는 먼저 축방향 및 원주방향 반타원 표면균열이 존재하는 직관의 완전 3차원 유한요소망 자동생성 프로그램을 작성하였다. 이렇게 생성된 유한요소 입력자료를 이용하여 3차원 유한요소 해석을 수행하면 반타원 표면균열선단을 따른 고온 크리프 파괴 지배변수 $C^{\ast}$-적분값을 구할 수 있다. 또한 $C^{\ast}$-적분값에 준해 균열진전량을 계산하는 후처리 균열진전 모듈을 추가하여 사용자 편의 수명평가 프로그램을 개발하였다. 최종적으로 개발된 통합 수명 평가 프로그램을 이용하여 여러 가지 해석변수들의 반타원 표면균열을 갖는 고온 직관 수명에 대한 영향을 살펴보았다.

  • PDF

Responses of self-anchored suspension bridge to sudden breakage of hangers

  • Qiu, Wenliang;Jiang, Meng;Zhang, Zhe
    • Structural Engineering and Mechanics
    • /
    • 제50권2호
    • /
    • pp.241-255
    • /
    • 2014
  • The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of a concrete self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger has significant effects on tensions of the hangers next to the broken hanger, bending and torsion moments of the girder, moments of the towers and reaction forces of the bearings. The results obtained from dynamic analysis method are very different from those obtained from static analysis method. The maximum tension of hanger produced by breakage of a hanger exceeds 2.2 times of its initial value, the maximum dynamic amplification factor reaches 2.54, which is larger than the value of 2.0 recommended for cable-stayed bridge in PTI codes. If two adjacent hangers on the same side of bridge break one after another, the maximum tension of other hangers exceeds 3.0 times of its initial value. If the safety factor adopted to design hanger is too small, or the hangers have been exposed to corrosion, the bridge may collapse due to breakage of two adjacent hangers.

Multiparametric Cardiac Magnetic Resonance Imaging Detects Altered Myocardial Tissue and Function in Heart Transplantation Recipients Monitored for Cardiac Allograft Vasculopathy

  • Muhannad A. Abbasi;Allison M. Blake;Roberto Sarnari;Daniel Lee;Allen S. Anderson;Kambiz Ghafourian;Sadiya S. Khan;Esther E. Vorovich;Jonathan D. Rich;Jane E. Wilcox;Clyde W. Yancy;James C. Carr;Michael Markl
    • Journal of Cardiovascular Imaging
    • /
    • 제30권4호
    • /
    • pp.263-275
    • /
    • 2022
  • BACKGROUND: Cardiac allograft vasculopathy (CAV) is a complication beyond the first-year post-heart transplantation (HTx). We aimed to test the utility of cardiac magnetic resonance (CMR) to detect functional/structural changes in HTx recipients with CAV. METHODS: Seventy-seven prospectively recruited HTx recipients beyond the first-year post-HTx and 18 healthy controls underwent CMR, including cine imaging of ventricular function and T1- and T2-mapping to assess myocardial tissue changes. Data analysis included quantification of global cardiac function and regional T2, T1 and extracellular volume based on the 16-segment model. International Society for Heart and Lung Transplantation criteria was used to adjudicate CAV grade (0-3) based on coronary angiography. RESULTS: The majority of HTx recipients (73%) presented with CAV (1: n = 42, 2/3: n = 14, 0: n = 21). Global and segmental T2 (49.5 ± 3.4 ms vs 50.6 ± 3.4 ms, p < 0.001;16/16 segments) were significantly elevated in CAV-0 compared to controls. When comparing CAV-2/3 to CAV-1, global and segmental T2 were significantly increased (53.6 ± 3.2 ms vs. 50.6 ± 2.9 ms, p < 0.001; 16/16 segments) and left ventricular ejection fraction was significantly decreased (54 ± 9% vs. 59 ± 9%, p < 0.05). No global, structural, or functional differences were seen between CAV-0 and CAV-1. CONCLUSIONS: Transplanted hearts display functional and structural alteration compared to native hearts, even in those without evidence of macrovasculopathy (CAV-0). In addition, CMR tissue parameters were sensitive to changes in CAV-1 vs. 2/3 (mild vs. moderate/severe). Further studies are warranted to evaluate the diagnostic value of CMR for the detection and classification of CAV.