• Title/Summary/Keyword: 3D Sensor

Search Result 1,597, Processing Time 0.032 seconds

A Study on Real-Time Sports Activity Classification & Monitoring Using a Tri-axial Accelerometer (가속도 센서를 이용한 실시간 스포츠 동작 분류.모니터링에 관한 연구)

  • Kang, Dong-Won;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.59-64
    • /
    • 2008
  • D. W. KANG, J. S. CHOI, and G. R. TACK, A Study on Real-Time Sports Activity Classification & Monitoring Using a Tri-axial Accelerometer. Korean Jouranl of Sport Biomechanics, Vol. 18, No. 2, pp. 59-64, 2008. This study was conducted to study the real-time sports activity classification and monitoring using single waist mounted tri-axial accelerometer. This monitoring system detects events of sports activities such as walking, running, cycling, transitions between movements, resting and emergency event of falls. Accelerometer module was developed small and easily attachable on waist using wireless communication system which does not constrain sports activities. The sensor signal was transferred to PC and each movement pattern was classified using the developed algorithm in real-time environment. To evaluate proposed algorithm, experiment was performed with several sports activities such as walking, running, cycling movement for 100sec each and falls, transition movements(sit to stand, lie to stand, stand to sit, lie to sit, stand to lie and sit to lie) for 20 times each with 5 healthy subjects. The results showed that successful detection rate of the system for all activities was 95.4%. In this study, through sports activity monitoring. it was possible to classify accurate sports activities and to notify emergency event such as falls. For further study, the accurate energy consumption algorithm for each sports activity is under development.

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

Laser-based THz Time-Domain Spectroscopy and Imaging Technology (레이저 기반 테라헤르츠 시간영역 분광 및 영상 기술)

  • Kang, Kwang-Yong;Kwon, Bong-Joon;Paek, Mun Cheol;Kang, Kyeong Kon;Cho, Suyoung;Kim, Jangsun;Lee, Senung-Churl;Lee, Dae-sung
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.317-327
    • /
    • 2018
  • Terahertz (THz) time-domain spectroscopy(TDS), imaging techniques, and related systems have become mature technologies, widely used in many universities and research laboratories. However, the development of creative technologies still requires improved THz application systems. A few key points are discussed, including the innovative advances of mode-locking energy-emitting semiconductor lasers and better photoconductive semiconductor quantum structures. To realize a compact, low cost, and high performance THz system, it is essential that THz spectroscopy and imaging technologies are better characterized by semiconductor and nano-devices, both static and time-resolved. We introduce the THz spectroscopy and imaging systems, the OSCAT(Optical Sampling by laser CAvity Tuning) system and the ASOPS(ASynchronous Optical Sampling) system, are constructed by our research team. We report on the THz images obtained from their use.

Measurement of Respiratory Motion Signals for Respiratory Gating Radiation Therapy (호흡동조 방사선치료를 위한 호흡 움직임 신호 측정)

  • Chung, Jin-Beom;Chung, Won-Kyun;Kim, Yon-Lae;Lee, Jeong-Woo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.59-63
    • /
    • 2005
  • Respiration motion causes movement of internal structures in the thorax and abdomen, making accurate delivery of radiation therapy to tumors in those areas a challenge. Accounting for such motion during treatment, therefore, has the potential to reduce margins drawn around the clinical target volume (CTV), resulting in a lower dose to normal tissues (e.g., lung and liver) and thus a lower risk of treatment induced complications. Among the techniques that explicitly account for intrafraction motion are breath-hold, respiration gating, and 4D or tumor-tracking techniques. Respiration gating methods periodically turn the beam on when the patient's respiration signal is in a certain part of the respiratory cycle (generally end-inhale or end-exhale). These techniques require acquisition of some form of respiration motion signal (infrared reflective markers, spirometry, strain gauge, thermistor, video tracking of chest outlines and fluoroscopic tracking of implanted markers are some of the techniques employed to date), which is assumed to be correlated with internal anatomy motion. In preliminary study for the respiratory gating radiation therapy, we performed to measurement of this respiration motion signal. In order to measure the respiratory motion signals of patient, respiration measurement system (RMS) was composed with three sensor (spirometer, thermistor, and belt transducer), 4 channel data acquisition system and mobile computer. For two patients, we performed to evaluation of respiratory cycle and shape with RMS. We observed under this system that respiratory cycle is generally periodic but asymmetric, with the majority of time spent. As expected, RMS traced patient's respiration each other well and be easily handled for application.

  • PDF

Research of Hydraulic Breaker with Rock Properties Predictability Using the ICT (ICT 융합기술을 활용한 암반특성 예측기능을 가진 유압 브레이커 개발에 관한 연구)

  • Yoon, Bok Joong;Lee, Kil Soo;Lim, Hoon;Lee, Ho Yeon;Lee, Myung Gyu;Kwon, Hyuk Jin;Kim, Kab Tae;Joo, Jin Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.683-689
    • /
    • 2017
  • We have carried out the development for hydraulic breaker which can be operated by optimal mode with ICT convergence technology. This developed system can predict the rock properties. Moreover, this system can maximize the energy efficient with intelligent control of hydraulic system. In order to provide the optimal impact force, this system can measure the descending depth of piston with the proximity sensor and discriminate the rock properties with the measuring data and control the piston stroke using solenoid valve eventually. In addition, we have developed the controller, display module and operating device for cascade (multi-level impact) system and applied the module which can communicate each system by wireless communications. In conclusion, the control system which can control the multi-level impact in accordance with strength of rocks has been developed and approved by several field tests.

Test Method Using VOC Analyzer to Measure VOC Emission of Paints for Wood-based Panel (VOC Analyzer를 이용한 목재용 도료의 휘발성유기화합물의 간이측정)

  • Eom, Young Geun;Kim, Ki-Wook;An, Jae-Yun;Kim, Hyun-Joong;Moon, Suck-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.65-72
    • /
    • 2007
  • The VOC (volatile organic compound) analyzer is devised to measure the four main aromatic hydrocarbon gases: toluene, ethylbenzene, xylene and styfene. It is not affected by ambient temperature and humidity. In addition, standby and measuring time of VOC Analyzer is a short as below 30 min and 8 min, respectively. Since the semiconductor gas sensor is supersensitive to gas components, it is not necessary to use a conventional gas concentrator or other complicated equipment. In this study, VOC emission behavior from 4 types paints (lacquer, urethane vanish, water-base paint, enamel paint) for wood-based panel was investigated using VOC Analyzer. After a specimen was spreaded on aluminum foil ($6.32{\times}6.32cm$) in $3{\ell}$ polyester bag, after 24 hours we could measure maximum VOC emission level that is a stabilized VOC value. Xylene of VOCs was high emitted from lacquer, urethane vanish and water-based paint, and TVOC (Toluene + Ethylbenzene + Xylene + Styrene) of lacquer was the highest emission concentration than another.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Interfacial Properties and Stress-Cure Sensing of Single-Shape Memory Alloy (SMA) Fiber/Epoxy Composites using Electro-Micromechanical Techniques (미세역학적 시험법을 이용한 단-섬유 형태 형상기억합금/에폭시 복합재료의 계면특성 및 응력-경화 감지능)

  • Jang, Jung-Hoon;Kim, Pyung-Gee;Wang, Zuo-Jia;Lee, Sang-Il;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.9 no.3
    • /
    • pp.20-26
    • /
    • 2008
  • It is well know that the structure of shape memory alloy (SMA) can change from martensite austenite by either temperature or stress. Due to their inherent shape recovery properties, SMA fiber can be used such as for stress or cure-monitoring sensor or actuator, during applied stress or temperature. Incomplete superelasticity was observed as the stress hysteresis at stress-strain curve under cyclic loading test and temperature change. Superelasticity behavior was observed for the single-SMA fiber/epoxy composites under cyclic mechanical loading at stress-strain curve. SMA fiber or epoxy embedded SMA fiber composite exhibited the decreased interfacial properties due to the cyclic loading and thus reduced shape memory performance. Rigid epoxy and the changed interfacial adhesion between SMA fiber and epoxy by the surface treatment on SMA fiber exhibited similar incomplete superelastic trend. Epoxy embedded single SMA fiber exhibited the incomplete recovery during cure process by remaining residual heat and thus occurring residual stress in single SMA fiber/epoxy composite.

  • PDF

Growth of Thin Film Using Chemical Bath Deposition Method and Their Photoconductive Characteristics (CBD 방법에 의한 CdS 박막의 성장과 광전도 특성)

  • Hong, K.J.;Lee, S.Y.;You, S.H.;Suh, S.S.;Moon, J.D.;Shin, Y.J.;Jeoung, T.S.;Shin, H.K.;Kim, T.S.;Song, J.H.;Rheu, K.S.
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.3-10
    • /
    • 1993
  • Polycrystalline CdS thin films were grown on ceramic substrate using a chemical bath deposition method. They were annealed at various temperature and X-ray diffraction patterns were measured by X-ray diffractometer in order to study CdS polycrystal structure. Using extrapolation method of X-ray diffraction patterns for the CdS samples annealed in $N_{2}$ gas at $550^{\circ}C$ it was found hexagonal structure whose lattice constants $a_{o}$ and $c_{o}$ were $4.1364{\AA}$ and $6.7129{\AA}$, respectively. Its grain size was about $0.35{\mu}m$. Hall effect on this sample was measured by Van der Pauw method and studied on carrier density and mobility defending on temperature. From Hall data, the mobility was likely to be decreased by piezo electric scattering at temperature range of 33K and 150k and by polar optical scattering at temperature range of 150K and 293K. We measured also spectral response, sensitivity (${\gamma}$), maximum allowable power dissipation and response time on these samples.

  • PDF

Study on the LOWTRAN7 Simulation of the Atmospheric Radiative Transfer Using CAGEX Data. (CAGEX 관측자료를 이용한 LOWTRAN7의 대기 복사전달 모의에 대한 조사)

  • 장광미;권태영;박경윤
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.99-120
    • /
    • 1997
  • Solar radiation is scattered and absorbed atmospheric compositions in the atmosphere before it reaches the surface and, then after reflected at the surface, until it reaches the satellite sensor. Therefore, consideration of the radiative transfer through the atmosphere is essential for the quantitave analysis of the satellite sensed data, specially at shortwave region. This study examined a feasibility of using radiative transfer code for estimating the atmospheric effects on satellite remote sensing data. To do this, the flux simulated by LOWTRAN7 is compared with CAGEX data in shortwave region. The CAGEX (CERES/ARM/GEWEX Experiment) data provides a dataset of (1) atmospheric soundings, aerosol optical depth and albedo, (2) ARM(Aerosol Radiation Measurement) radiation flux measured by pyrgeometers, pyrheliometer and shadow pyranometer and (3) broadband shortwave flux simulated by Fu-Liou's radiative transfer code. To simulate aerosol effect using the radiative transfer model, the aerosol optical characteristics were extracted from observed aerosol column optical depth, Spinhirne's experimental vertical distribution of scattering coefficient and D'Almeida's statistical atmospheric aerosols radiative characteristics. Simulation of LOWTRAN7 are performed on 31 sample of completely clear days. LOWTRAN's result and CAGEX data are compared on upward, downward direct, downward diffuse solar flux at the surface and upward solar flux at the top of the atmosphere(TOA). The standard errors in LOWTRAN7 simulation of the above components are within 5% except for the downward diffuse solar flux at the surface(6.9%). The results show that a large part of error in LOWTRAN7 flux simulation appeared in the diffuse component due to scattering mainly by atmispheric aerosol. For improving the accuracy of radiative transfer simulation by model, there is a need to provide better information about the radiative charateristrics of atmospheric aerosols.