• Title/Summary/Keyword: 3D Medical Image Data

Search Result 208, Processing Time 0.029 seconds

A Functional Mapping Workstation of Human Brain Images

  • Paik, Chul-Hwa;Kim, Tae-Woo;Song, Myung-Jin;Yu, Hyun-Sun;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.301-303
    • /
    • 1996
  • A platform is developed for fast and effective functional mapping of human brain, which can allow semi-automatically the whole processes of an image segmentation, a fusion of MR and PET images, and 3-D rendering of volumetric data, including DICOM-based image transfers from PACS archiver within a short period of time.

  • PDF

4D Reconstruction of Cine Cardiac MR Images (심장 자기공명영상의 4차원 재구성)

  • Lee, D.H.;Kim, J.H.;Song, I.C.;Cho, S.S.;Park, J.H.;Han, M.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.314-316
    • /
    • 1996
  • To diagnose cardiac malfunctions, various imaging techniques have been applied to heart : DSA(Digital Subtracted Angiography), Doppler Ultrasound, MR Angio. But it is difficult to observe three dimensional heart motion which is the most intuitive tool for diagnosis, only by using these methods. In this research, we have suggested 4-Dimensional reconstruction scheme of heart motion images that can be acquired by ECG-gated cine MR imaging. One cardiac cycle was devided into $9\sim15$ phases and for each phase 3D reconstructed volumn heart was made. We can observe 3D volumns along the cardiac cycle, time. So the results were 4-D reconstructed data.

  • PDF

3D Medical Image Segmentation Using Region-Growing Based Tracking (영역 확장 기반 추적을 이용한 3차원 의료 영상 분할 기법)

  • Ko S.;Yi J.;Lim J.;Ra J. B.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.239-246
    • /
    • 2000
  • In this paper. we propose a semi-automatic segmentation algorithm to extract organ in 3D medical data by using a manually segmentation result in a sing1e slice. Generally region glowing based tracking method consists of 3 steps object projection. seed extraction and boundary decision by region growing. But because the boundary between organs in medical data is vague, improper seeds make the boundary dig into the organ or extend to the false region. In the proposed algorithm seeds are carefully extracted to find suitable boundaries between organs after region growing. And the jagged boundary at low gradient region after region growing is corrected by post-processing using Fourier descriptor. Also two-path tracking make it possible to catch up newly appeared areas. The proposed algorithm provides satisfactory results in segmenting 1 mm distance kidneys from X-rav CT body image set of 82 slices.

  • PDF

Three-Dimensional Image Reconstruction from Compton Scattered Data Using the Row-Action Maximum Likelihood Algorithm (행작용 최대우도 알고리즘을 사용한 컴프턴 산란 데이터로부터의 3차원 영상재구성)

  • Lee, Mi-No;Lee, Soo-Jin;Nguyen, Van-Giang;Kim, Soo-Mee;Lee, Jae-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.56-65
    • /
    • 2009
  • Compton imaging is often recognized as a potentially more valuable 3-D technique in nuclear medicine than conventional emission tomography. Due to inherent computational limitations, however, it has been of a difficult problem to reconstruct images with good accuracy. In this work we show that the row-action maximum likelihood algorithm (RAMLA), which have proven useful for conventional tomographic reconstruction, can also be applied to the problem of 3-D reconstruction of cone-beam projections from Compton scattered data. The major advantage of RAMLA is that it converges to a true maximum likelihood solution at an order of magnitude faster than the standard expectation maximiation (EM) algorithm. For our simulations, we first model a Compton camera system consisting of the three pairs of scatterer and absorber detectors placed at x-, y- and z-axes, and generate conical projection data using a software phantom. We then compare the quantitative performance of RAMLA and EM reconstructions in terms of the percentage error. The net conclusion based on our experimental results is that the RAMLA applied to Compton camera reconstruction significantly outperforms the EM algorithm in convergence rate; while computational costs of one iteration of RAMLA and EM are about the same, one iteration of RAMLA performs as well as 128 iterations of EM.

Influence of Job Satisfaction in Emergency Medical Technician within Hospital upon Organizational Commitment (병원 내 응급구조사의 직무만족도가 조직몰입에 미치는 영향)

  • Park, Sang-Sub;Park, Jae-Seong;Park, Dae-Sung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.2
    • /
    • pp.99-108
    • /
    • 2009
  • Purpose : The purpose of this study is to offer basic data in arranging the improved working environment to Emergency Medical Technicians, by analyzing the influence of job satisfaction in Emergency Medical Technician within hospital upon organizational commitment. Method : This study was carried out targeting 203 Emergency Medical Technicians who are working at hospitals in B Metropolitan City, U Metropolitan City, D Metropolitan City, an d G Province. The data collection was performed from April 1, 2009 to June 10. The statistical processing was used a program of SPSS WIN 12.0 Version. The statistical significance was set to p<.05. Results : 1. In the descriptive statistics of the job satisfaction and the organizational commitment. the whole average for job satisfaction was 3.06 points. The whole average for organizational commitment was 3.05 points. 2. In the difference between job satisfaction and organizational commitment, the group for job satisfaction was indicated to be statistically significant in job-choice motive(F=2.710, p<.05) and turnover propensity(t=.662, p<.001). The group for organizational commitment was indicated to be statistically significant in working department(F=2.871, p<.05), job-choice motive(F=2.944, p<.05), turnover propensity(t=.903, p<.001), and turnover reason(F=3.415, p<.01). 3. In the correlation between job satisfaction and organizational commitment, the job satisfaction showed positive correlation(r=.736, p<.01) with organizational commitment. 4. As for the influence of job-satisfaction factor upon organizational commitment, salary(${\beta}$=.162, t=2.739, p<.01), autonomy(${\beta}$=.372, t=4.633, p<.001), working environment(${\beta}$=.139, t=1.968, p<.05), and organizational needs(${\beta}$=.172, t=2.291, p<.05) were indicated to have significant effect on organizational commitment. Conclusion : The institutional arrangement is considered to be likely to be necessarily made highly for improving social image and enhancing salary and working environment so that Emergency Medical Technician within hospital can be enhanced job satisfaction and organizational commitment.

  • PDF

Application of 3D Simulation Surgery to Orbital Wall Fracture : A preliminary Case Study

  • Choi, Jong-Woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.16-18
    • /
    • 2014
  • The orbit has a very special anatomical structure. The complex anatomical structure should be restored when we encounter the patient with orbital wall fracture. Unless these specific anatomy were reconstructed well, the patient should suffer from various complications such enophthalmos, diplopia or orbital deformity. In addition, because the patient has a his own specific orbital shape, individualized approach will be necessary. The aim of this trial is to try to restore the original orbit anatomy as possible based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. In order to restore the missing skipped images between the cuts of CT data because of the thinness of the orbital walls, we manipulated the DICOM data for imaging the original orbital contour using the preoperatively manufactured mirror-image of the RP model. And we fabricated Titanium-Medpor to reconstruct three-dimensional orbital structure intraoperatively. This prefabricated Titanium-Medpor was then inserted onto the defected orbital wall and fixed. Three dimensional approach based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Impact of self image and self-esteem on job satisfaction of 119 Rescue workers (119구급대원의 자기이미지와 자아존중감이 직무만족도에 미치는 영향)

  • Uhm, Dong-Choon;Hwang, Seong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3786-3793
    • /
    • 2013
  • This study aimed to investigate the influence of self-image, and self-esteem of 119 Rescue workers in D city on job satisfaction. This research design was a descriptive study. Data were collected from November 19, 2012 to December 08, 2012, analyzed by SPSS 20.0 program. There were statistical difference between age, period of employment, position, and license and self-image. There were statistical difference between age, position, license and self-esteem. There were statistical differences between age, period of employment, position and job satisfaction. Job satisfaction was positively related to self-image and self-esteem. In the multivariate regression analysis, adjusted R2 value was 0.268. It is necessary to enhance the career and awareness of job satisfaction of 119 rescue workers.

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

Automated Brain Region Extraction Method in Head MR Image Sets (머리 MR영상에서 자동화된 뇌영역 추출)

  • Cho, Dong-Uk;Kim, Tae-Woo;Shin, Seung-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.3
    • /
    • pp.1-15
    • /
    • 2002
  • A noel automated brain region extraction method in single channel MR images for visualization and analysis of a human brain is presented. The method generates a volume of brain masks by automatic thresholding using a dual curve fitting technique and by 3D morphological operations. The dual curve fitting can reduce an error in clue fitting to the histogram of MR images. The 3D morphological operations, including erosion, labeling of connected-components, max-feature operation, and dilation, are applied to the cubic volume of masks reconstructed from the thresholded Drain masks. This method can automatically extract a brain region in any displayed type of sequences, including extreme slices, of SPGR, T1-, T2-, and PD-weighted MR image data sets which are not required to contain the entire brain. In the experiments, the algorithm was applied to 20 sets of MR images and showed over 0.97 of similarity index in comparison with manual drawing.

  • PDF

Automatic Lung Registration using Local Distance Propagation (지역적 거리전파를 이용한 자동 폐 정합)

  • Lee Jeongjin;Hong Helen;Shin Yeong Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.1
    • /
    • pp.41-49
    • /
    • 2005
  • In this Paper, we Propose an automatic lung registration technique using local distance propagation for correcting the difference between two temporal images by a patient's movement in abdomen CT image obtained from the same patient to be taken at different time. The proposed method is composed of three steps. First, lung boundaries of two temporal volumes are extracted, and optimal bounding volumes including a lung are initially registered. Second, 3D distance map is generated from lung boundaries in the initially taken volume data by local distance propagation. Third, two images are registered where the distance between two surfaces is minimized by selective distance measure. In the experiment, we evaluate a speed and robustness using three patients' data by comparing chamfer-matching registration. Our proposed method shows that two volumes can be registered at optimal location rapidly. and robustly using selective distance measure on locally propagated 3D distance map.