• Title/Summary/Keyword: 3D MOTION ANALYSIS

Search Result 744, Processing Time 0.028 seconds

Comparison and Analysis of Motion Capture and Key Animation - Focused on Animation of Countenance - (모션 캡처와 키 애니메이션의 비교분석 - 얼굴표정애니메이션을 중심으로 -)

  • Jang, Wook;Choi, Sung-Kyu;Lee, Tae-Gu
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.160-169
    • /
    • 2007
  • Main problem in the domestic motion capture type production is that motion data are used even in the case when the human sensibility is needed. In other words it fails to give human images to the work, and production method only use motion capture data unconditionally and impetuously. Even though motion capture is effective and are various and applicable to various areas, it would cause enormous lose of capital and manual labor if these problems are not solved. In the present study, we compare motion capture with key animation production and analyze the merits and short comings of them. Also, we analyze them through the actual production and present the efficient method of key animation production when the expensive motion capturing devices are not available.

A study on the turning-motion of T/S SAEBADA in shallow water (실습선 새바다호의 천수역 선회운동에 관한 연구)

  • KIM, Su-Hyung;LEE, Chun-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.55 no.3
    • /
    • pp.273-283
    • /
    • 2019
  • The authors has predicted the maneuvering characteristics of a fishing vessel in deep water using Kijima's empirical formula in a previous study. Since the Kijima's empirical formula was developed by a regression analysis of merchant vessels which have dimensions ($C_b$, L/B, etc.) that are different from those of fishing vessels, it was possible to make a prediction approximately even with inaccurate estimation. In this study, the authors estimated the turning-motion characteristics of a model ship of fisheries training ship in shallow water based on the results of its previous study. The turning-motion characteristics of the model ship in shallow water was found out through quantitative analysis according to the water depth to ship draft ratio (H/d). In conclusion, the turning-motion characteristics of the model ship had significant changes immediately after an H/d 1.5, and this result will be helpful for sailing in shallow water.

The Effects of Sloshing on the Responses of an LNG Carrier Moored in a Side-by-side Configuration with an Offshore Plant (해양플랜트에 병렬 계류된 LNG 운반선의 거동에 슬로싱이 미치는 영향)

  • Lee, Seung-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.16-21
    • /
    • 2010
  • During the loading/offloading operation of a liquefied natural gas carrier (LNGC) that is moored in a side-by-side configuration with an offshore plant, sloshing that occurs due to the partially filled LNG tank and the interactive effect between the two floating bodies are important factors that affect safety and operability. Therefore, a time-domain software program, called CHARM3D, was developed to consider the interactions between sloshing and the motion of a floating body, as well as the interactions between multiple bodies using the potential-viscous hybrid method. For the simulation of a floating body in the time domain, hydrodynamic coefficients and wave forces were calculated in the frequency domain using the 3D radiation/diffraction panel program based on potential theory. The calculated values were used for the simulation of a floating body in the time domain by convolution integrals. The liquid sloshing in the inner tanks is solved by the 3D-FDM Navier-Stokes solver that includes the consideration of free-surface non-linearity through the SURF scheme. The computed sloshing forces and moments were fed into the time integration of the ship's motion, and the updated motion was, in turn, used as the excitation force for liquid sloshing, which is repeated for the ensuing time steps. For comparison, a sloshing motion coupled analysis program based on linear potential theory in the frequency domain was developed. The computer programs that were developed were applied to the side-by-side offloading operation between the offshore plant and the LNGC. The frequency-domain results reproduced the coupling effects qualitatively, but, in general, the peaks were over-predicted compared to experimental and time-domain results. The interactive effects between the sloshing liquid and the motion of the vessel can be intensified further in the case of multiple floating bodies.

A Review of Motion Capture Systems: Focusing on Clinical Applications and Kinematic Variables (모션 캡처 시스템에 대한 고찰: 임상적 활용 및 운동형상학적 변인 측정 중심으로)

  • Lim, Wootaek
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.87-93
    • /
    • 2022
  • To solve the pathological problems of the musculoskeletal system based on evidence, a sophisticated analysis of human motion is required. Traditional optical motion capture systems with high validity and reliability have been utilized in clinical practice for a long time. However, expensive equipment and professional technicians are required to construct optical motion capture systems, hence they are used at a limited capacity in clinical settings despite their advantages. The development of information technology has overcome the existing limit and paved the way for constructing a motion capture system that can be operated at a low cost. Recently, with the development of computer vision-based technology and optical markerless tracking technology, webcam-based 3D human motion analysis has become possible, in which the intuitive interface increases the user-friendliness to non-specialists. In addition, unlike conventional optical motion capture, with this approach, it is possible to analyze motions of multiple people at simultaneously. In a non-optical motion capture system, an inertial measurement unit is typically used, which is not significantly different from a conventional optical motion capture system in terms of its validity and reliability. With the development of markerless technology and advent of non-optical motion capture systems, it is a great advantage that human motion analysis is no longer limited to laboratories.

Embedding of Objects Using SFM Analysis in Synthetic Image Sequences (합성영상에서의 이동물체의 SFM분석을 통한 물체의 삽입)

  • 최경업;김용철
    • Proceedings of the IEEK Conference
    • /
    • 2000.11c
    • /
    • pp.181-184
    • /
    • 2000
  • This paper presents an experimental system, where an object extracted from an image sequence is embedded into the desired position in a scene. First, a moving object is detected and the 3-D structure is obtained by SFM analysis of comer trajectories. We constrained the motion to translational motion only. Extracted objects are classified by matching with 3-D models and then the structure of the occluded part is restored. Camera calibration is performed for the background scene which will embed the object. Finally, the object is embedded into the scene. In the experiments, we used synthetic image sequences generated with OpenGL library for easy evaluation of the 3-D structure estimation.

  • PDF

Study on Gait Analysis of Elders and Hemiplegia Patients using 3D Motion Analysis (고령자 및 편마비 환자의 3 차원 동작분석을 통한 보행 특성에 관한 연구)

  • Jang, Hye-Youn;Han, Jung-Soo;Han, Chang-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.7
    • /
    • pp.730-736
    • /
    • 2012
  • Latest, many researchers do research on wearable robot. The purpose of the researches is very diverse, it will improve efficiency in the industry, taken to replace the many workers in the military field and taken to assist bodily functions run out by aging. However, there is no clear Differentiated strategy depending on the purpose for design and control of the wearable robot. Although a common purpose is to drive the robot by the sensor signal (intent signals), the optimization about the mechanism and control studies must be done according to the user's physical ability and purpose. In this study, the study's first phase for the development of wearable robotic gait rehabilitation, gait characteristics were analyzed elders and hemiplegia patients using a 3D gait analysis system (VICON512). As a result, asymmetric gait characteristics of the hemiplegia patients were found compared with the normal elderly.

Analysis of Skin Movement Artifacts Using MR Images (자기공명 영상을 이용한 피부 움직임 에러 분석에 관한 연구)

  • ;N. Miyata;M. Kouchi;M. Mochimaru
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.8
    • /
    • pp.164-170
    • /
    • 2004
  • The skin movement artifacts are referred to as the relative motion of skin with respect to the motion of underlying bones. This is of great importance in joint biomechanics or internal kinematics of human body. This paper describes a novel experiment that measures the skin movement of a hand based on MR(magnetic resonance) images in conjunction with surface modeling techniques. The proposed approach consists of 3 phases: (1) MR scanning of a hand with surface makers, (2) 3D reconstruction from the MR images, and (3) registration of the 3D models. The MR images of the hand are captured by 3 different postures. And the surface makers which are attached to the skin are employed to trace the skin motion. After reconstruction of 3D models from the scanned MR images, the global registration is applied to the 3D models based on the particular bone shape of different postures. The results of registration are then used to trace the skin movement by measuring the positions of the surface markers.

A Study on the Dynamic Analysis for Flexible Robotic Arms (유연 로보트팔의 동특성 해석에 관한 연구)

  • Kim, Chang-Boo;You, Young-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.3
    • /
    • pp.107-116
    • /
    • 1993
  • In the design and operation of robitic arm with flexible links, the equation of motion are required to exactly model the interaction between rigid body motion and elastic motion and to be formulated efficientlyl. In this paper, the flexible link is represented by applying the D-H rigid link representation method to measure the elestic deformation. And the equations of motion of robotic arm, which are configured by the generalized coordinates of elastic and rigid degrees of freedom, are formulated from the principle of virtual power. Dynamic characteristics due to elastic deformation of each link are obtained by using F. E. M to model complex shaped link acurately and by eliminating elastic modes of higher order that do not largely affect motion to reduce the number of elastic degrees of freedom. Also presented is the result of simulation of flexible robotic arms whose joints are controlled by direct or PD control.

  • PDF

Kinematical analysis of Yurchenko Streched at Horse Vaulting (도마운동 유리첸코 몸 펴 공중돌기 동작의 운동학적 분석)

  • Yoon, Chang-Sun;Kim, Tae-Sam;Yoon, Hee-Joung
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.67-79
    • /
    • 2003
  • The purpose of this study is to investigate the effective skill motion through the kinematic analysis of the Yurchenko Streched motion in new horse vaulting. The subjects in this study were 3 male gymnasts who were ranked as national athletes. After the 3D motion analysis, kinematic variables were analyzed to comparison with the difference between this study and the previous study(Yang, D. Y and Lee, C. S, 1999). As a result, the following conclusions was drawn; 1. In the board contact phase, this study showed a shorten contact time to maintain in condition highly extension of hip and hee angle than the previous study. 2. In the pre-flight phase, this study appeared more shortly flight duration time and horizontal flight displacement than the previous study. 3. In the horse contact phase, the contact duration time and horizontal displacement of COG shortened than the previous study, but appeared to the fast horizontal and vertical velocity and highly extension of shoulder an. 4. In the post-flight phase, a stable horse contact appeared to the increase of the flight duration time and the apex height during the post-flight. And it showed that these results have a stable and good landing.

Effects of Hallux Valgus Orthoses on Ground Reaction Force Using 3D Motion Analysis in Individuals With Hallux Valgus Deformity

  • Kim, Yong-wook
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.227-232
    • /
    • 2020
  • Background: Hallux valgus (HV) is a foot deformity developed by mediolateral deviation of the first metatarsophalangeal joint. Although various foot-toe orthoses were used to correct the HV angle, verification of the effects of kinetics variables such as ground reaction force (GRF) through three-dimensional (3D) gait analysis according to the various type of orthoses for HV is insufficient. Objects: This study aimed to investigate the effect of soft and hard types of foot and toe orthoses to correct HV deformity on the GRF in individuals with HV using 3D motion analysis system during walking. Methods: Twenty-six subjects participated in the experiment. Participants had HV angle of more than 15° in both feet. Two force platforms were used to obtain 3D GRF data for both feet and a 3D motion capture system with six infrared cameras was used to measure exact stance phase point such as heel strike or toe off period. Total walk trials of each participant were 8 to 10, the walkway length was 6 m. Two-way repeated measures ANOVA was used to determine the effects of each orthosis condition on the various GRF values. Results: The late anteroposterior maximal force and a first vertical peak force of the GRF showed that the hard type orthosis condition significantly increased GRF compared to the other orthosis conditions (p < 0.05). Conclusion: There were significant effects in GRF values when wearing the hard type foot orthosis. However, the hard type foot orthosis was uncomfortable to wear during walking. Therefore, it is necessary to develop a new foot-toe orthosis that can compensate for these disadvantages.