• Title/Summary/Keyword: 3D Image Scan

Search Result 233, Processing Time 0.038 seconds

Comparison of Virtual Avatars by Using Automatic and Manual Method

  • Lim, Ho-Sun;Istook, Cynthia L.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.12
    • /
    • pp.1968-1979
    • /
    • 2010
  • New technology that includes 3D body scanning, digital virtual human, and digital virtual garments has had a significant impact on the current apparel industry. Virtual simulation technology enables the visualization of a 3D virtual garment on a virtual avatar so that consumers can try on garments with their virtual avatars before purchasing. However, the manual virtual avatar provided for online apparel shopping currently has revealed limitations on the different body sizes and shapes of customers. This study analyzes the process of designing the automatic virtual avatar and the manual virtual avatar using OptiTex software; in addition, the study compares the practicality of the automatic virtual avatar with that of the manual virtual avatar. Data was examined by evaluating how much each virtual avatar is similar to the real body and how well it matched the needs of the current apparel industry. In the study, Avatar 1 was automatically created from three-dimensional body scan data and Avatar 2 was manually created from body measurements. The virtual avatar images laid over a real body image and the results were evaluated by comparing the simulated sizes of virtual avatars with those of a real body. Consequently, Avatar 1 was evaluated as more similar to the real body than Avatar 2 in all five body shapes. This study illustrates that an automatic virtual avatar might solve the fit problem that is the most common reason for a high return rate for online shopping. The results show that future virtual simulation technology needs to be improved for the practicality of the virtual avatars.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Usefullness of CT Gastrography and Vurtual Gastroscopy using Computed Tomography in Detection of Gastric Cancer (위암 진단에 있어서의 CT 위장 조영술과 상부위장관 조영술과의 비교)

  • Baik Yong Hae;Lee Soon Jin;Lee Ji Yun;Noh Jae Hyung;Sohn Tae Sung;Kim Sung;Kim Yong Il
    • Journal of Gastric Cancer
    • /
    • v.3 no.4
    • /
    • pp.195-200
    • /
    • 2003
  • Purpose: Advancement of computed tomography (CT) hardware and software has allowed thin section scanning and reconstruction of fascinating 2-dimentional (2D) and 3- dimentional (3D) images. Especially, the reconstruction of 3D images of gastrointestinal tract has been used in the detection and diagnosis of pre-malignant and malignant diseases. To compare the efficacy of CT gastrography with conventional upper gastrointenstinal series (UGIs) in gastric cancer patients. Materials and Methods: During Nov. 2002 and Mar. 2003, twenty-seven patients who had gastric cancer received both double contrast upper GI series and CT gastrography prior to radical surgery. Among these patients, nineteen had early gastric cancer (EGC) and 8 had advanced gastric cancer (AGC). Fifteen patients were male and 12 were female. The mean age was 54 yrs (range, $27\∼75$ yrs). The patients were placed on NPO and Stomach was distended with gas in fasting state prior to CT scanning. Double contrast upper GI series were performed as routine manual. CT scan was conducted in all patients using 8 or 16-channel multidetector CT in this study. The collimation and reconstruction for CT scanning were set at 2.5 mm and 1.25 mm, respectively. CT scanning was performed in the supine position. For image processing, CT gastrography, in which raysum and surface rendering images were constructed, virtual and 2D image in coronal and sagittal images were performed. The detectability of gastric cancer was assessed between UGIs and CT gastrography. Results: In AGCs, the detection rate of cancer using CT gastrography and virtual gastroscopy was higher than EGC cases. However, CT gastrography and virtual gastroscopy showed less favorable results than UGIs. Even though only a small number of cases had been studied, we might conclude that CT gastrography and virtual gastroscopy could replace UGIs in the detection of AGC cases. Conclusion: The detection rate used with CT gastrography and Virtual gastroscopy is not better than that of UGIs in early gastric cancer, however, in advanced gastric cancer cases, it is nearly equal to that of UGIs.

  • PDF

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

Development of a Micro-CT System for Small Animal Imaging (소 동물 촬영을 위한 Micro-CT의 개발)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.97-102
    • /
    • 2004
  • We developed an x-ray cone-beam micro computed tomography (micro-CT) system for small-animal imaging. The micro-CT system consists of a 2-D flat-panel x-ray detector with a field-of-view (FOV) of 120${\times}$120 mm2, a micro-focus x-ray source, a scan controller and a parallel image reconstruction system. Imaging performances of the micro-CT system have been evaluated in terms of contrast and spatial resolution. The minimum resolvable contrast has been found to be less than 36 CT numbers at the dose of 95 mGy and the spatial resolution about 14 lp/mm. As small animal imaging results, we present high resolution 3-D images of rat organs including a femur, a heart and vessels. We expected that the developed micro-CT system can be greatly used in biomedical studies using small animals.

Large Point Cloud-based Pipe Shape Reverse Engineering Automation Method (대용량 포인트 클라우드 기반 파이프 형상 역설계 자동화 방법 연구)

  • Kang, Tae-Wook;Kim, Ji-Eum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.692-698
    • /
    • 2016
  • Recently, the facility extension construction and maintenance market portion has increased instead of decreased the newly facility construction. In this context, it is important to examine the reverse engineering of MEP (Mechanical Electrical and Plumbing) facilities, which have the high operation and management cost in the architecture domains. The purpose of this study was to suggest the Large Point Cloud-based Pipe Shape Reverse Engineering Method. To conduct the study, the related researches were surveyed and the reverse engineering automation method of the pipe shapes considering large point cloud was proposed. Based on the method, the prototype was developed and the results were validated. The proposed method is suitable for large data processing considering the validation results because the rendering performance standard deviation related to the 3D point cloud massive data searching was 0.004 seconds.

Gesture-based Table Tennis Game in AR Environment (증강현실과 제스처를 이용한 비전기반 탁구 게임)

  • Yang, Jong-Yeol;Lee, Sang-Kyung;Kyoung, Dong-Wuk;Jung, Kee-Chul
    • Journal of Korea Game Society
    • /
    • v.5 no.3
    • /
    • pp.3-10
    • /
    • 2005
  • We present the computer table tennis game using player's swing motion. We need to transform a real world coordinate into a virtual world coordinate in order to hit the virtual ball. We can not get a correct 3-dimension position of racket in environment that using one camera or simple image processing. Therefore we use Augmented Reality (AR) concept to develop the game. This paper shows the AR table tennis game using gesture and method to develop the 3D interaction game that only using one camera without any motion detection device or stereo cameras. Also, we use a scan line method to recognize gesture for speedy processing. The game is developed using ARtoolkit and DirectX that is popular tool of SDK for game development.

  • PDF

Usefulness of the High B-value DWI in Brain Tumors (뇌종양 확산강조영상에서 High B-value의 유용성 평가)

  • Kim, Jin-tae;Byun, Jae-Hu;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism (폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성)

  • Kim, Woo-Gyu;Lim, Byung-Sung;Kim, Mi-Young;Hwang, Hweung-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.669-680
    • /
    • 1999
  • Background: Pulmonary thromboembolism(PTE) is a life threatening disease that needs early diagnosis. Spiral CT angiography depict thromboemboli in the central pulmonary vessels with greater than 90% sensitivity and specificity, which approaches the results of pulmonary angiography in the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED) study. This study was performed to evaluate the findings and the diagnostic value(clinical utility) of the spiral CT angiography with 2D image(multiplanar reformation) and 3D images(Shaded surface display, Minimal intensity projection) in the pulmonary thromboembolism. Methods: We retrospectively analysed spiral CT angiography and pulmonary angiography, lung scan and clinical recordings of 20 patients who had PTE diagnosed by spiral CT angiography(n=19 cases) or pulmonary angiography(n=l case) from September 1997 to August 1998. Among 20 patients who had underwent spiral CT angiography, 14 patients could be performed lung perfusion scan at the same time. We analyzed the vascular and parenchymal change in spiral CT angiogram. Results: Anatomical distribution of PTE was as follows: 1) left lung(n= 103)

  • PDF