• Title/Summary/Keyword: 3D Flow measurement

Search Result 253, Processing Time 0.028 seconds

FSI Analysis on a Floating Cylinder by 3D Flow-Structure Interaction (FSI) Measurement System (유동-구조상관(FSI) 3차원 측정시스템에 의한 부유식 실린더 연동운동해석)

  • Doh, D.H.;Sang, J.W.;Hwang, T.G.;Pyeon, Y.B.;Baek, T.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1574-1579
    • /
    • 2004
  • A simultaneous measurement system that can analyze the flow-structure interactions(FSI) has been constructed and analyses on the flow field and the motion field of a floating cylinder was made. The three-dimensional vector fields around the cylinder are measured by 3D-PTV technique while the motion of the cylinder forced by the flow field is measured simultaneously with a newly developed motion tracking algorithm(bidirectional tracking algorithm). The cylinder is pendant in the working fluid of a water channel and the surface of the working fluid is forced sinusoidal to make the cylinder bounced. The interaction between the flow fields and the cylinder motion is examined quantitatively.

  • PDF

Measurement of 3D Flow inside Micro-tube Using Digital Holographic PTV Technique (디지털 Holographic PTV기법을 이용한 미세튜브 내부 3차원 유동장 측정)

  • Kim, Seok;Kim, Ju-Hee;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.177-178
    • /
    • 2006
  • Digital holographic particle tracking velocimetry (HPTV) is developed by single high-speed camera and single continuous laser with long coherent length. This system can directly capture 4000 hologram fringe images for 1 second through a camera computer memory. The 3D particle location is made of the reconstruction by using a computer hologram algorithm. This system can successfully be applied to instantaneous 3D velocity measurement in the water flow inside a micro-tube. The average of 100 instantaneous velocity vectors is obtained by reconstruction and tracking with the time of evolution of recorded fringes images. In the near future, we will apply this technique to measure 3D flow information inside various micro structures.

  • PDF

4-D PTV

  • Doh Deog Hee;OKAMOTO Koji
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.33-40
    • /
    • 2004
  • A 4D-PTV system was constructed. The measurement system consists of three high-speed high-definition cameras(1k x 1k, 2000fps), Nd-Yag laser(2000Hz) and a host computer. The GA-3D-PTV algorithm was used for completing the measurement system. The 4D-PTV is capable of probing the spatial distribution of velocity vectors of the flow field overcoming the temporal resolution of the characteristic turbulence length scales of the measured flow fields. A horizontal impinged jet flow (H/D=7) was measured. The Reynolds number is about 33,000. Spatial temporal evolution of the jet flow was examined and physical properties such as spatial distributions of vorticity and turbulent kinetic energy were obtained with the constructed.

  • PDF

3D-PTV Measurements of the Wake of a Goldfish (3D-PTV에 의한 금붕어 후류 계측)

  • Doh, D.H.;Hwang, T.G.;Chang, G.S.;Bang, Y.S.;Sang, J.W.;Kim, D.J.;Baek, T.S.;Cho, Y.B.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2054-2059
    • /
    • 2003
  • 3D-PTV measurement was conducted on the wake of a goldfish in order to understand its swimming motions. The measurement system consisted of three CCD cameras, an image grabber, an Ar-Ion laser and a host computer. The flow properties of the wake of the goldfish were measured under three different velocities of the currents. Unsteady flow structures around the goldfish were quantitatively clarified using the time-consecutive instantaneous three-dimensional vectors obtained by the constructed 3D-PTV system.

  • PDF

Automatic Extraction of Particle Streaks for 3D Flow Measurement

  • Kawasue, Kikuhito;Ohya, Yuichiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.270-273
    • /
    • 1999
  • Circular dynamic stereo has special advantages as it enables a 3-D measurement using a single TV camera and also enables a high accurate measurement without a cumbersome calibration. Annular particle streaks are recorded using this system and the size of annular streaks directly concerns to the depth from TV camera. That is, the size of annular streaks is inversely proportional to the depth from the TV camera and the depth can be measured automatically by image processing technique. Overlapped streaks can be processed also by our method. The flow measurement in a water tank is one of the applications of our system. Tracer particles are introduced into the water in a flow measurement. Since the tracer particles flow with water, three-dimensional velocity distributions in the water tank can be obtained by measuring the all movement of tracer particles. Experimental results demonstrate the feasibility of our method.

  • PDF

Intake Flow Characteristics with SCV Open Ratio in a 4-Valve Direct Diesel Engine (4밸브 직분식 디젤엔진의 SCV 개구율에 따른 흡입유동특성)

  • 최승환;전충환;장영준;이진욱
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.66-75
    • /
    • 1999
  • Many researchers have developed the measurement technique of in-cylinder flow. Recently, there are lots of studies on steady flow with different SCV geometries. In this study the flow characteristics of four-valve cylinder head were examined in a steady test rig for different SCV open ratios. Each swirl ratio of several SCV angle was quantified by swirl impulse meter and 2D-LDV measurement. The results showed that the swirl ratio was controlled between 2.3 and 3.8 based on SCV angles. The velocity distributions of in-cylinder flow field were measured by 2-D LDV test and visualized swirl and tumble flow pattern at different positions. In this engine , we found out that the swirl was dominant flow.

  • PDF

Development of Stereoscopic Micro-PTV Method (Stereoscopic micro-PTV기법의 개발)

  • Yu, Cheong-Hwan;Kim, Hyoung-Bum
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.109-113
    • /
    • 2007
  • Micro-PIV is a well-known method for measurement of two- dimensional, two-component velocity in the microfluidic devices. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is helpful to understand the physics of micro flow phenomena. In this study, we developed new micro 3D measurement method by applying 2-frame PTV in stereoscopic micro system. In this study, we did the validation study of SMPTV by using the simulated flow model to verify the accuracy and the feasibility of measurement and compared with SMPIV method. The results showed that SMPTV provides better spatial resolution and measurement accuracy than SMPIV method.

  • PDF

An experimental study of a flow field generated by a rotating cylinder on a plane moving at free stream velocity (자유흐름 속도의 이동면과 맞닿은 회전실린더 주위 유동장의 실험적 해석)

  • Park, Un-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.700-712
    • /
    • 1997
  • The flowfield generated by a 2-D rotating cylinder on a plane moving at freestream velocity was experimentally investigated in a wind tunnel to simulate aerodynamic characteristics of rotating wheels of an automobile. In the flowfield around a rotating cylinder at 3*10$^{3}$ < Re$_{d}$<8*10$^{3}$, unique mean flow and turbulence characteristics were confirmed by hot-wire measurements as well as frequency analysis, which was supported by flow visualization. In the vicinity of a rotating cylinder, a unique turbulence structure on .root.over bar u'$^{2}$ profiles was formed in hump-like shape at 1 < y/d < 3. A peak frequency which characterized the effect of a rotating cylinder had the same value of the rotation rate of a cylinder. In case of cylinder rotation, the depths of mean velocity -defect and turbulent-shear regions were thickened by 20-40% at 0 < x/d < 10 compared with the case of cylinder stationary. Far downstream beyond x/d > 10, the flowfield generated by a rotating cylinder showed self-similarity in the profiles of mean velocity and turbulence quantities. The effect of a rotating cylinder was independent of its rotation rate and Reynolds number in the measurement range.

4D-PTV(Dynamic 3D-PTV) Measurement on an Impinged Jet (4차원 입자영상유속계(다이나믹 3차원 입자영상유속계)에 의한 충돌분류측정)

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Cho, Yong-Beom;Pyeon, Yong-Beom;Koji, Okamoto
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1767-1771
    • /
    • 2004
  • A 4D-PTV system was constructed. The measurement system consists of three high-speed high-definition cameras, Nd-Yag laser(10mJ, 2000fps) and a host computer. The GA-3D-PTV algorithm was used to extract three-dimensional velocity vectors in the measurement volume. A horizontal impinged jet flow was measured with the constructed system. The Reynolds number is about 40,000. Spatial temporal evolution of the jet flow was examined in detail and physical properties such as spatial distributions of vorticity and turbulent kinetic energy were obtained with the constructed system.

  • PDF

Development of Stereoscopic PIV Measurement Technique and Its Application to Wake behind an Axial Fan (Stereoscopic PIV 기법의 개발과 이를 이용한 축류 홴 후류의 유동해석)

  • Yun, Jeong-Hwan;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.362-373
    • /
    • 2002
  • A stereoscopic PIV (SPIV) measurement system based on the translation configuration was developed and applied to the flow behind a forward-swept axial-fan. Measurement of three orthogonal velocity components is essential for flow analysis of three-dimensional flows such as flow around a fan or propeller. In this study, the translation configuration was adopted to calculate the out-of-plane velocity component from 2-D PIV data obtained from two CCD cameras. The error caused by the out-of-plane motion was estimated by direct comparison of the 2-D PIV and 3-D SPIV results that measured from the particle images captured simultaneously. The comparison shows that the error ratio is relatively high in the region of higher out-of-plane motion near the axial fan blade. The turbulence intensity measured by the 2-D PIV method is bigger by about 5.8% in maximum compared with that of the 3-D SPIV method. The phase-averaged velocity field results show that the wake behind an axial fan has a periodic flow structure with respect to the blade phase and the characteristic flow structure is shifted downstream in the next phase.