• 제목/요약/키워드: 3D FEA

검색결과 231건 처리시간 0.027초

핫프레스포밍 공정의 냉각치구 설계에 관한 연구 (Study on the design of quenching fixture in hot press forming process)

  • 이경훈;곽은정;김헌영;이기동;박종규;서창희
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2009
  • In hot press forming process, the desired high strength can be obtained through quenching process after cold forming of product. The quenching process, however, accompanies undesired distortion due to the volume change during the phase transformation as well as by thermal contraction. In this study the numerical simulation with DEFORM3D-Microstructure is used to predict the deformed shape during the quenching for the quenching fixture design.

  • PDF

분리형 섕크를 갖는 SPR의 형상 설계를 위한 유한요소해석 (Finite Element Analysis for Design of Divided Shank of Self-Piercing Rivet)

  • 김관우;김동범;조해용
    • Journal of Welding and Joining
    • /
    • 제34권2호
    • /
    • pp.54-58
    • /
    • 2016
  • SPR(Self-Piercing rivet) is mechanical element of joining sheet metal components without the need for pre-punched or pre-drilled holes. Newly designed SPR is developed for high joining strength and shearing strength than semi-tubular rivet. In this study, divided shank of self-piercing rivet were designed for joining DP440 and SILAFONT. Newly designed SPR was simulated by using FEM code DEFORM-3D. In simulations of SPR process, various shape of self-piercing rivet were considered for semi-tubular and newly designed SPR. In other to examine the joinability, joining load and lap-shear load of newly designed SPR were compared with semi-tubular by simulated results and experimental ones.

스캐너용 Claw-pole PM형 스테핑 모터의 설계 방법 (Design Method of the Claw-pole PM Stepping Motor for Scanner)

  • 유용민;오상열;김직
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.118-121
    • /
    • 2005
  • The claw-pole PM(Permanent Magnet) stepping motor has the advantage of the positioning machine because of a relatively little step angle, facility of control, and detent torque characteristics. Although the research about this motor has been progressed, it was difficult to analyze because of three-dimensional magnetic circuit. This paper proposed a design method of the claw-pole PM stepping motor using 3D-FEA. We established design variables that have an important effect upon the characteristics of the motor, and then peformed analysis of the static and the dynamic characteristics. We also manufactured the test products and practiced the performance tests for verification of the analysis results.

  • PDF

새로운 구조를 갖는 마이크로 PM형 스테핑 모터 개발 (Development of the Micro PM type Stepping Motor with Newly Structure)

  • 류세현;권병일;정인성;성하경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1261-1263
    • /
    • 2005
  • The micro permanent magnet(PM) type stewing motor preferred solution for many small electronics position determination devices since it is small in size. Thus, there are growing demands for PM type stepping motor that greater mechanical output, smaller size. But, the design of the it, having high performance and small size is very difficult because of its complex mechanical structure. This paper deals with a development of the newly structured micro PM type stepping motor with claw-poles. We introduced the small-sized PM type stepping motor that has new structure and analyzed the magnetic characteristic of it versus general type model using 3-D finite element analysis(FEA).

  • PDF

Reduction of Torque Ripple in an Axial Flux Generator Using Arc Shaped Trapezoidal Magnets in an Asymmetric Overhang Configuration

  • Ikram, Junaid;Khan, Nasrullah;Khaliq, Salman;Kwon, Byung-il
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.577-585
    • /
    • 2016
  • In this paper, model of the axial-flux permanent magnet synchronous generator (AFPMSG) having arc-shaped trapezoidal permanent magnets (PM) is presented. The proposed model reduces the cogging torque and torque ripple, at the expense of lowering the average output torque. Optimization of the proposed model is performed by considering the asymmetric overhang configuration of the PMs, as to make the output torque of the proposed model competitive with the conventional model. The time stepped 3D finite element analysis (FEA) is performed for the comparative analysis. It is demonstrated that the torque ripple of the optimized model is highly reduced as well as average output torque is increased.

3차원 경계요소법과 전선 유한요소 해석의 연성을 통한 전선 유탄성 해석 (Analysis on the Hydroelasticity of Whole Ship Structure by Coupling Three-dimensional BEM and FEM)

  • 김경환;방제성;김용환;김승조
    • 대한조선학회논문집
    • /
    • 제49권4호
    • /
    • pp.312-326
    • /
    • 2012
  • This paper considers a fully coupled 3D BEM-FEM analysis for the ship structural hydroelasticity problem in waves. Fluid flows and structural responses are analyzed by using a 3D Rankine panel method and a 3D finite element method, respectively. The two methods are fully coupled in the time domain using a fixed-point iteration scheme, and a relaxation scheme is applied for improve convergence. In order to validate the developed method, numerical tests are carried out for a barge model. The computed natural frequency, motion responses, and time histories of stress are compared with the results of the beam-based hydroelasticity program, WISH-FLEX, which was thoroughly validated in previous studies. This study extends to a real-ship application, particularly the springing analysis for a 6500 TEU containership. Based on this study, it is found that the present method provides reliable solutions to the ship hydroelasticity problems.

3차원으로 직조된 복합재 보강 패널의 기계적 특성 연구 (Mechanical Characteristics of 3-dimensional Woven Composite Stiffened Panel)

  • 정재형;홍소망;변준형;남영우;권진회
    • Composites Research
    • /
    • 제35권4호
    • /
    • pp.269-276
    • /
    • 2022
  • 본 연구에서는 층간분리의 위험이 없는 3차원 직조방식으로 복합재 보강패널을 제작하고 좌굴하중과 고유진동수 등의 기계적 특성을 연구하였다. 보강패널의 스트링거와 외피는 일체형으로 제작하였고 T800급 탄소섬유로 만들어진 프리폼에 수지(EP2400)를 충진시키는 방식을 적용하였다. 제작된 보강판에 대하여 압축시험과 고유진동수 측정 시험을 수행하였고 유한요소해석 결과와 비교하였다. 또한 3차원 직조 구조물의 성능을 상대적으로 비교하기 위해 일방향 프리프레그와 2차원 평직(fabric)으로 동일한 치수의 보강패널을 제작하여 시험과 해석을 수행하였다. 시험값을 기준으로 일방향 프리프레그와 2차원 평직으로 제작된 보강패널의 좌굴하중은 3차원 직조 패널의 좌굴하중 대비 각각 20%, -3%의 차이를 보였다. 본 연구로부터 3차원 직조방식으로 제작된 일체형 보강패널의 좌굴하중은 일방향 프리프레그 적층 보강판의 좌굴하중보다는 낮지만 2차원 평직 보강판넬보다는 미세하게 높은 수준의 값을 보임을 확인하였다.

Evaluation of reliability of zirconia materials to be used in implant-retained restoration on the atrophic bone of the posterior maxilla: A finite element study

  • Degirmenci, Kubra;Kocak-Buyukdere, Ayse;Ekici, Bulent
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.112-119
    • /
    • 2019
  • PURPOSE. Zirconia materials have been used for implant-retained restorations, but the stress distribution of zirconia is not entirely clear. The aim of this study is to evaluate the stress distribution and risky areas caused by the different design of zirconia restorations on the atrophic bone of the posterior maxilla. MATERIALS AND METHODS. An edentulous D4-type bone model was prepared from radiography of an atrophic posterior maxilla. Monolithic zirconia and zirconia-fused porcelain implant-retained restorations were designed as splinted or non-splinted. 300-N occlusal forces were applied obliquely. Stress analyses were performed using a 3D FEA program. RESULTS. According to stress analysis, the bone between the 1) molar implant and the 2) premolar in the non-splinted monolithic zirconia restoration model was stated as the riskiest area. Similarly, the maximum von Mises stress value was detected on the bone of the non-splinted monolithic zirconia models. CONCLUSION. Splinting of implant-retained restorations can be more critical for monolithic zirconia than zirconia fused to porcelain for the longevity of the bone.

지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향 (Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis)

  • 박현수;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

골시멘트 특성 및 스템 형상에 따른 시멘트 타입 인공관절의 생체역학적 평가 (Biomechanical Evaluation of Cement type hip Implants as Conditions of bone Cement and Variations of Stem Design)

  • 박흥석;전흥재;윤인찬;이문규;최귀원
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.212-221
    • /
    • 2008
  • The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors. The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters. The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FE A using commercial stem model (Zimmer's V erSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.