• 제목/요약/키워드: 3D CFD analysis

검색결과 391건 처리시간 0.024초

FROM THE DIRECT NUMERICAL SIMULATION TO SYSTEM CODES - PERSPECTIVE FOR THE MULTI-SCALE ANALYSIS OF LWR THERMALHYDRAULICS

  • Bestion, D.
    • Nuclear Engineering and Technology
    • /
    • 제42권6호
    • /
    • pp.608-619
    • /
    • 2010
  • A multi-scale analysis of water-cooled reactor thermalhydraulics can be used to take advantage of increased computer power and improved simulation tools, including Direct Numerical Simulation (DNS), Computational Fluid Dynamics (CFD) (in both open and porous mediums), and system thermalhydraulic codes. This paper presents a general strategy for this procedure for various thermalhydraulic scales. A short state of the art is given for each scale, and the role of the scale in the overall multi-scale analysis process is defined. System thermalhydraulic codes will remain a privileged tool for many investigations related to safety. CFD in porous medium is already being frequently used for core thermalhydraulics, either in 3D modules of system codes or in component codes. CFD in open medium allows zooming on some reactor components in specific situations, and may be coupled to the system and component scales. Various modeling approaches exist in the domain from DNS to CFD which may be used to improve the understanding of flow processes, and as a basis for developing more physically based models for macroscopic tools. A few examples are given to illustrate the multi-scale approach. Perspectives for the future are drawn from the present state of the art and directions for future research and development are given.

CFD 모델을 이용한 수중방류 온배수의 근역 동수역학 해석 (Near-Field Hydrodynamic Analysis of the Submerged Thermal Discharge Using CFD Model)

  • 황인태;김덕호
    • 한국해안·해양공학회논문집
    • /
    • 제23권6호
    • /
    • pp.466-473
    • /
    • 2011
  • 온배수의 수중 방류 시 강한 방류 모멘텀 플럭스와 부력 플럭스에 의해 수중제트 인근에는 부력제트가 지배적인 근역이 형성되며, 이러한 근역을 해석하는 도구로써 비정수압 RANS 방정식을 적용한 전산유체역학(CFD) 모델을 이용하여 근역에 대한 적용성을 검토해 보았다. 과거 연구된 바 있는 원형 부력제트 수리실험과 유사한 조건으로 모델을 구성하고 정류시의 수평 부력 제트 경우와 가로흐름시 수직 부력 제트 경우에 대해 수치 실험을 수행하였다. CFD 수치실험의 결과는 수리실험 및 해석해 모델(CorJET)의 결과와 무차원화한 중심 궤적 및 희석율에 대해 비교 검증하였는데, 실제 수리실험의 결과와 잘 일치하는 것으로 나타났다. CFD 모델은 현재 근역 해석해 모델과 광역 준3차원 해수유동 모델이 가지고 있는 한계를 모두 보완할 수 있어 수중방류 온배수 영향해석에 적합한 모델이며, 본 연구를 통해 근역해석의 적합성을 확인하였으므로 향후 계산효율이 확보된다면 수중방류 온배수의 이동 및 확산 해석 도구로써 널리 활용될 것으로 기대된다.

마이크로 모세관 유동 해석을 위한 CFD-VOF 모텔 응용 (Application of CFD-VOF Model to Autonomous Microfluidic Capillary System)

  • 정자훈;임예훈;한상필;석지원;김영득
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.224-229
    • /
    • 2004
  • The objective of this work is not only to perform feasibility studies on the CFD (computational fluid dynamics) analysis for the capillary system design but also to provide an enhanced understanding of the autonomous capillary flow. The capillary flow is evaluated by means of the commercial CFD software of FLUENT, which includes the VOF (volume-of-fluid) model for multiphase flow analysis. The effect of wall adhesion at fluid interfaces in contact with rigid boundaries is considered in terms of static contact angle. Feasibility studies are first performed, including mesh-resolution influence on pressure profile, which has a sudden increase at the liquid/gas interface. Then we perform both 2D and 3D simulations and examine the transient nature of the capillary flow. Analytical solutions are also derived for simple cases and compared with numerical results. Through this work, essential information on the capillary system design is brought out. Our efforts and initial success in numerical description of the microfluidic capillary flows enhance the fundamental understanding of the autonomous capillary flow and will eventually pave the road for full-scale, computer-aided design of microfluidic networks.

  • PDF

발전용 보일러에 대한 다중영역분할 화로해석 기법의 활용성 연구 (Study on the Multi-Zone Furnace Analysis Method for Power Plant Boiler)

  • Baek, SeHyun;kim, Donggyu;Lee, Jang Ho
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.427-432
    • /
    • 2020
  • 본 연구에서는 화력 발전소 보일러에 대한 연소 및 열전달 해석을 위하여 화로 내부를 다중영역으로 나누고 각 영역에서 energy와 mass balance는 1차원으로 계산하고, 복사열전달은 3차원으로 계산하는 다중영역분할 화로해석 기법을 활용하였다. 그리고 적용 기법에 대한 신뢰성 검증을 위하여 국내 500 MW 급 석탄화력 보일러 화로에 대한 계산 값과 보일러 제작사의 설계 데이터를 비교하여 양호함을 확인하였고, 동일한 설비에 대한 CFD 해석과 비교한 결과 유사한 경향을 얻었다. 본 계산 기법은 CFD 화로해석 보다는 덜 상세하지만, 빠른 시간에 연료반응성, 화로형상 및 운전변수에 따른 특성을 계산할 수 있는 장점이 있으므로 발전소 현장에서의 설비감시진단 및 일일 연료/운전 계획 수립 등 활용성 측면에서 유용할 것으로 예상된다.

차량용 전자식 솔레노이드 밸브 필터간의 유동특성에 관한 연구 (A Study on Flow Characteristics about Valve Filter for Electronic System Solenoid Structure)

  • 김병준;조행묵
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1294-1298
    • /
    • 2014
  • 향후 제작 될 솔레노이드 구조의 방향을 제시하고자 실험 및 유동 특성에 대한 비교 분석 연구가 진행 되어졌다. 실험값과 해석값의 비교 분석은 ANSYS CFD와 전자식 측정 기구를 이용하여 수행하였다. 구조의 3D 모델링은 CATIA V5R18을 이용하였으며, 유동구간의 격자 생성은 ICEM CFD 프로그램을 사용하였다. 유동해석 분석은 수치해석 프로그램인 ANSYS CFD를 이용하여 실험값에 대한 검증이 진행되었다. 실험값을 통해 정밀 필터구간에서 나타난 유량은 $0-10{\ell}/min$ 으로 나타났으며 유동해석결과 최대 $0.18{\ell}/min$로 나타났다. 유동 해석 결과와 실험값의 비교분석을 통해 유동환경에 보다 효율적인 솔레노이드 구조를 제시 할 수 있었다.

DPF의 배기가스 유동 및 포집에 관한 다차원 모델링 연구 (Study on Multi-Dimensional Simulation of the Flow and Filtration Characteristics in Diesel Particulate Filters)

  • 김동균;윤천석
    • 한국자동차공학회논문집
    • /
    • 제18권3호
    • /
    • pp.60-68
    • /
    • 2010
  • In order to understand the flow and filtration characteristics in a wall-flow type DPF(Diesel Particulate Filter), 0-D, 1-D, and 3-D simulations are preformed. In this paper, three model are explained and validated with each other. Based on the comparisons with 1-D and 3-D results for the steady state solution, 3-D CFD analysis is preferable to 1-D for the prediction of wall velocity at the inlet and exit plane. Because PM loading process is transient state phenomena, the combination of full 3-D and time dependent simulation is crucial for the configuration of wall channels. New coupling technique, which is the connection between calculated permeability from 0-D lumped parameter model and UDF(User Defined Functions) of main solver, is proposed for the realisti

FLOW-3D에 의한 파샬플륨 흐름 해석 (Flow Analysis of Parshall Flume Using FLOW-3D)

  • 오병동;김경호;이환기;안상도
    • 한국수자원학회논문집
    • /
    • 제37권5호
    • /
    • pp.375-386
    • /
    • 2004
  • 갈수량은 수자원의 개발 및 관리에 매우 중요한 인자중의 하나이다. 신뢰성 높은 갈수량을 측정하기 위해 한국수자원공사는 2000년도에 용담댐 시험유역에 5피트 규격의 파샬플륨을 설치하였다. 파샬플륨은 유량측정을 하기 위해 독특한 모양을 가지고 있으며, 부정확한 유량관측을 유발하는 퇴사문제를 거의 해결한 시설물이다. 본 연구에서는 3차원 CFD (Computational Fluid Dynamics) 모형으로 5가지 수위에 대해서 완전월류(free flow)시 파샬플륨의 유동을 해석하였다. CFD모형에 의해 산정된 결과와 ISO에 제시된 유량공식, USBR에 제시된 유량공식 및 수위-유량관계식으로 산정한 유량을 비교하였다. 그 결과 ISO와 USBR의 공식에 의해 산정된 유량은 거의 동일했으나, 3차원 CFD모형에 의한 유량은 경험공식에 의한 유량보다 9%정도 크게 나타났고 수위-유량관계식에 의한 유량은 경험공식에 의한 유량보다 16%정도 작게 나타났다.

전산유체역학을 이용한 PEMFC의 성능에 대한 3차원 유로 구조의 영향 (Effects of 3D Flow-Channel Configurations on the Performance of PEMFC using Computational Fluid Dynamics)

  • 한경호;윤도영
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.847-853
    • /
    • 2016
  • 본 연구에서는 3차원 전산유체역학 모델을 적용하여 서펜타인 유로를 갖는 고분자 전해질 분리막(PEM) 연료전지의 성능평가를 수행하였다. PEM 연료전지의 전산 모델은 등온조건하에서의 이동현상을 고려하여, 물질 및 운동량 전달, 전극에서의 반응속도론 그리고 전기적 흐름을 모두 포함하였다. 한편, 병류로 흐르도록 형성된 구조의 유로 형태는 본 연료전지모델에서 유로의 폭과 높이의 비인 종횡비와 유로와 립 폭의 비인 반응면적비를 변화시키며 다양한 형상으로 고려되었다. 유로의 형상이 변화될 경우 연료전지 내부의 수소와 산소의 질량분율 분포가 계산되었으며, 이에 따라, 활성화과전압의 계산 값이 변하게 되며 전류밀도 분포가 최종적으로 결정되었다. CFD 결과는 종횡비가 클수록 성능이 증가하고 반응면적비가 클수록 성능이 감소하는 것을 보였다. 본 연구의 모델에 의하면 서펜타인 유로의 형상에 의해, 성능특성이 경향성을 보이는 결과를 보여주었으며, 이와같은 결과는 다른 문헌에 보고 된 CFD 결과들과 전반적으로 잘 부합하는 것으로 나타났다.

터보 팬의 유동해석 및 허니콤 구조가 적용된 터보 팬의 PBF 3D 프린팅 제작에 관한 연구 (A Study on CFD of Turbo fan and Fabrication of Turbo Fan with Honeycombs by PBF)

  • 진철규;이해수;이운길;우재혁
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.899-908
    • /
    • 2022
  • In this study, a study was conducted to localize a large aluminum turbo fan used for tank powerpack. The turbo fan was scanned with a 3D scanner and then 3D modeling was performed. Computational fluid dynamics (CFD) were performed from the performance conditions of the fan, and structural analysis was performed using the pressure data obtained from CFD. The fan was reduced to 1/5 size by applying the geometric similarity. A 1/5 size fan has a honeycomb structure inserted into the front shroud and back shroud to reduce the weight by 5.3%. A 1/5 size fan was printed using a PBF 3D printer, and a 1/5 size fan with honeycombs was also printed. The pressure drop of 8.67 kPa and the required power of 138.19 kW, which satisfies the performance conditions of the fan, were confirmed from the results of CFD. The values of the maximum deformation amount of 0.000788 mm and the maximum effective stress of 0.241 MPa were confirmed from the structural analysis results. The fan printed by the PBF 3D printer had the same shape as the modeling, and the shape was perfect. There are no defects anywhere in appearance. However, the condition of the outer surface of the fan's back shroud is rough compared to other locations. The fan in which the honeycomb was inserted was also perfectly output, and the shape of the honeycomb was the same as the modeling.

수치해석을 이용한 파력발전용 임펄스 터어빈의 성능해석 (Analysis of Impulse Turbine for Wave Energy Conversion Using CFD Method)

  • 현범수;문재승
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.81-86
    • /
    • 2003
  • This paper deals with the performance analysis and design of impulse turbine for OWC type wave energy plant. Numerical analysis was performed using a commercially-available software FLUENT. This parametric study includes the variation of several important parameters such as the number and shape of blades, hub ratio and tip clearance. Since parametric study at various flow coefficients requires considerable amount of computing tim, two-dimensional analysis was employed to find out optimum principal particulars in rather simple manner. Full three-dimensional calculation was also performed for several test cases to confirm the validity of two-dimensional approach. Up to the present stage, tentative result is well demonstrating the usefulness of 2-D analysis.

  • PDF