• Title/Summary/Keyword: 3D Blade

Search Result 294, Processing Time 0.028 seconds

Numerical Optimization of a Multi-blades Centrifugal Fan for High-efficiency Design (원심다익송풍기의 고효율 설계를 위한 수치최적설계)

  • Seo, Seoung-Jin;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.3 s.24
    • /
    • pp.32-38
    • /
    • 2004
  • Shape of a multi-blades centrifugal fan is optimized by response surface method based on three-dimensional Navier-Stokes analysis. For numerical analysis, Reynolds-averaged Navier-Stokes equations with standard $k-{epsilon}$ turbulence model are transformed into non-orthogonal curvilinear coordinate system, and are discretized with finite volume approximations. Due to the large number of blades in this centrifugal fan, the flow inside of the fan is regarded as steady flow by introducing the impeller force models for economic calculations. Optimizations with and without constraints are carried out. Design variables, location of cur off, radius of cut off, expansion angle of scroll and width of impeller were selected to optimize the shapes of scroll and blades. Data points for response evaluations were selected by D-optimal design, and linear programming method was used for the optimization on the response surface. As a main result of the optimization, the efficiency was successfully improved. The correlation of efficiency with relative size of inactive zone at the exit of impeller is discussed as well as with average momentum fluxes in the scroll.

The Analysis of Vibration characteristics for Vacuum Cleaner Fan Motor Using 3-D Laser Vibrator (3차원 레이저 진동 측정기를 이용한 초고속 진공청소기 모터의 진동특성분석)

  • 김재열;김우진;심재기;김영석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.399-405
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000 rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

  • PDF

Experimental Study on the Vortical Flow Behind 2-D Blade with the Variation of Trailing Edge Shape (2차원 날개 끝단 형상에 따른 후류 보오텍스 유동 변화에 대한 실험 연구)

  • Paik, Bu-Geun;Kim, Ki-Sup;Moon, Il-Sung;Ahn, Jong-Woo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.3
    • /
    • pp.233-237
    • /
    • 2011
  • In the present experiments, vortical structures behind the hydrofoil trailing edge are visualized and analyzed as an elementary study for propeller singing phenomena. Two sorts of hydrofoil are selected for the measurement of shedding vortices. One was KH45 hydrofoil section and the other is KH45 with the truncated trailing edge that is positioned at X/C = 0.9523(C=chord length). Assuming the Strouhal number of 0.23, the shedding frequencies of vortices are extracted by analyzing the boundary layer thickness and the flow speed. The frequency distribution of shedding vortices is obtained with the variation of angle-of-attack while the flow speed is fixed to 8m/s. The truncation of the trailing edge makes the frequency of shedding vortices about 120Hz lower than that of original trailing edge and makes the vorticity value higher than the original trailing edge.

Studies on the growth of Korea Lawn Grass (Zoysia japonica Steud.)in Reponse to Nitrogen Application, Clipping Treatment and Plant Density (질소시용, 예초 및 재식밀도가 한국잔디(Zoysia Japonica Steud)의 생육에 미치는 영향)

  • Sim, Jae-Seong
    • The Journal of Natural Sciences
    • /
    • v.1
    • /
    • pp.61-113
    • /
    • 1987
  • The increasing emphasis placed on the production of fine turf for lawns, golf courses, parks, and other recreational sites has led to many unsolved problems as to how such turf could be best established and mainteined. For this purpose, a series of experiments were conducted under con ditions of pot and field. The results obtained were as follows EXPERIMENT I. The effect of nitrogen fertilizer and clipping interval on Zoysia japonica. 1. Increasing the rate of nitrogen and frequent clipping increased tiller number of Zoysis japonica and the maximum number of tillers were obtained from 700 kg N application and freqnent clippings (10 days interval ) in October. Treatment of 350kg N with 10 days clipping interval increased tillers much more than those of 700 kgN with 20 and 30 days clipping intervals. 2. The average number of green leaves occurred during the growth period maximized by applying 700 kg N and clipping 10 days interval. 3. Increasing tiller numbers significantly decreased tops DM weight per tiller by clipping plants at interval of 10 and 20 days, irrespective of nitrogen applied, and with nil N, at the interval of 30 days. By applying 700 kg N, however, top DM weight per tiller increased as the number of tillers increased consistently. 4. The highest top DM weight was achieved from late August to early September by applying 350 and 700kgN. 5. During the growth period, differences in unders ( stolon + root ) DM weight occurred bynitrogen application were found between nil N and two applied nitrogen levels, whereas, at the same level of nitrogen applied, the increase in stolon DM weight enhanced by lengthening the clipping interval to 30 days. 6. Nitrogen efficiency to green leaves, stolon nodes and DM weight of root with high nitrogen was achieved as clipping interval was shortened. 7. By increasing fertilizer nitrogen rate applied, N content n the leaves and stems of Zoysiajaponica was increased. On the other hand, N content in root and stolon had little effect onfertilizer nitrogen, resulting in the lowest content among plant fractions. The largest content of N was recorded in leaves. Lengthening the clipping interval from 10 or 20 to 30 days tends to decrease the N content in the leaves and stems, whereas this trend did not appeared in stolon androot. 8. A positive correlations between N and K contents in tops and stolon were established andthus K content increased as N content in tops and stolon increased. Meanwhile, P content was not affected by N and clipping treatments. 9. Total soluble carbohydrate content in Zoysia japonica was largest in stolon and stem, and was reduced by increasing fertilizer nitrogen rate. Reduction in total soluble carbohydrate due to increased nitrogen rate was severer in the stolons and stems than in the leaves. 10. Increasing the rate of nitrogen applied increased the number of small and large vascular bundles in leaf blade, but shortened distance among the large vascular bundles. Shortening the clipping interval resulted in increase of the number of large vascular bundles but decrease ofdistance between large vascular bundles.EXPERIMENT II. Growth response of Zoysia japonica imposed by different plant densities. 1. Tiller numbers per unit area increased as plant density heightened. Differences in num ber between densities at higher densities than 120 D were of no significance. 2. Tiller numbers per clone attained by 110 days after transplanting were 126 at 40D,77 at 80D, 67 at 120D, 54 at 160D, and 41 at 200D. A decreasing trend of tiller numbers per clone with increasing density was noticable from 100 days after transplanting onwards. 3. During the growth period, the greatest number of green leaves per unit area were attainedin 90days after transplanting at 160D and 200D, and 100 days after transplanting at 40D, 80Dand 120D. Thus the period to reach the maximum green leaf number with the high plantdensity was likely to be earlier that with the low plant density. 4. Stolon growth up to 80 days after transplaning was relatively slow, but from 80 daysonwards, the growth quickened to range from 1.9 m/clone at 40D to 0.6m/clone at 200Din 200 days after transplanting, these followed by the stolon node produced. 5. Plant density did not affect stolon weight/clone and root weight/clone until 80 daysafter transplanting. 6. DM weight of root was heavier in the early period of growth than that of stolon, butthis trend was reversed in the late period of growth : DM weight of stolon was much higherthan that of root.EXPERIMENT Ill. Vegetative growth of Zoysia japonica and Zoysia matrella as affected by nitrogen and clipping height. 1. When no nitrogen was applied to Zoysia japonica, leaf blade which appeared during theAugust-early September period remained green for a perid of about 10 weeks and even leavesemerged in rate September lived for 42 days. However, leaf longevity did not exceed 8 weeks asnitrogen was applied. In contrast the leaf longevity of Zoysia matrella which emerged during the mid August-earlySeptember period was 11 weeks and, under the nitrogen applied, 9 weeks, indicating that thelife-spen of individual leaf of Zoysia matrella may be longer than that of Zoysia japorica. Clipping height had no effect on the leaf longevity in both grasses. 2. During the July-August period, tiller number, green leaf number and DM weightof Zoysia japonica were increased significantly with fertilizer nitrogen, but were not with twolevel of clipping height. This trend was reversed after late September ; no effect of nitrogen wasappeared. Instead, lax clipping increased tiller number, green leaf number and DM weight. Greenleaves stimulated by lax clipping resulted in the occurrance of more dead leaves in late October. 3. Among the stolons outgrown until early September, the primary stolon was not influencedby nitrogen and clipping treatments to produce only 2-3 stolons. However, 1st branch stoIon asaffected by nitrogen increased significantly, so most of stolons which occurred consisted of 1st branch stolons. 4. Until early September, stolon length obtained at nil nitrogen level was chiefly caused bythe primary stolons. By applying nitrogen, the primary stolons of Zoysia japonica waslonger than 1st branch stolons when severe clipping was involved and in turn, shorter than 1stbranch stolons when lax clipping was concerned. In Zoysia matrella, 1st branch stolons were muchlonger than the primary stolon when turf was clipped severely but in conditions of lax clippingthere was little difference in length between primary and 1st branch stolons. 5. Stolon nodes of both Zoysia japonica and Z. matrella were positively influenced by nit rogen, but no particular increase by imposing clipping height treatment was marked in Zoysiamatrella. Although the stolon of Zoysia japonica grew until late October, the growthstimulated by nitrogen was not so remarkable as to exceed that by nil N.

  • PDF

Numerical Study of the Rib Arrangements for Enhancing Heat Transfer in a Two-pass Channel of Large Aspect Ratio (종횡비가 큰 이차유로에서 냉각성능 향상을 위한 요철배열 연구)

  • Han, Sol;Choi, Seok Min;Sohn, Ho-Seong;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The present study investigated the effect of the rib arrangement and a guide vane for enhancing internal cooling of the blade. Two types of rib arrangements were used in the first and second passage in parallel. Aspect ratio of the channel was 5 and a fixed Reynolds number based on hydraulic diameter was 10,000. The attack angle of rib was $60^{\circ}$, rib pitch-to-height ratio (p/e) was 10, and the rib height-to-hydraulic-diameter ratio ($e/D_h$) was 0.075. The effect of an interaction between Dean vortices and the secondary vortices from the first passage was observed. Overall, the attack angle of rib in the first passage was dominant factor to heat transfer and flow patterns in turning region. Also, the channel with a guide vane showed enhanced heat transfer at the tip surface with reducing flow separation and recirculation.

Structural Analysis of Floating Offshore Wind Turbine Tower Based on Flexible Multibody Dynamics (탄성 다물체계 동역학을 기반으로 한 부유식 해상 풍력 발전기 타워의 구조 해석)

  • Park, Kwang-Phil;Cha, Ju-Hwan;Ku, Namkug;Jo, A-Ra;Lee, Kyu-Yeul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1489-1495
    • /
    • 2012
  • In this study, we perform the structural analysis of a floating offshore wind turbine tower by considering the dynamic response of the floating platform. A multibody system consisting of three blades, a hub, a nacelle, the platform, and the tower is used to model the floating wind turbine. The blades and the tower are modeled as flexible bodies using three-dimensional beam elements. The aerodynamic force on the blades is calculated by the Blade Element Momentum (BEM) theory with hub rotation. The hydrostatic, hydrodynamic, and mooring forces are considered for the platform. The structural dynamic responses of the tower are simulated by numerically solving the equations of motion. From the simulation results, the time history of the internal forces at the nodes, such as the bending moment and stress, are obtained. In conclusion, the internal forces are compared with those obtained from static analysis to assess the effects of wave loads on the structural stability of the tower.

Performance Analysis on 2-Bladed Tidal Current Power Turbine (해양 조류발전용 2블레이드 터빈의 성능해석)

  • Lee, Kanghee;Yim, Jinyoung;Rho, Yuho;Song, Seungho;Jo, Chulhee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.236.1-236.1
    • /
    • 2010
  • Due to global warming, the need to secure an alternative resource has become more important nationally. Due to the high tidal range of up to 9.7m on the west coast of Korea, numerous tidal current projects are being planned and constructed. The rotor, which initially converts the energy, is a very important component because it affects the efficiency of the entire system, and its performance is determined by various design variables. In this paper, a design guideline of current generating HAT rotor and acceptable field rotor in offshore environment is proposed. To design HAT rotor model, wind mill rotor design principles and turbine theories were applied based on a field HAT rotor experimental data. To verify the compatibility of the rotor design method and to analyze the properties of design factors, 3D CFD model was designed and analysed by ANSYS CFX. The analysis results and findings are summarized in the paper.

  • PDF

Evaluation of Cutter Orientations in 5-Axis High Speed Milling of Turbine Blade (터빈블레이드의 5축 고속가공에서 가공경로와 공구기울임 방향의 선정)

  • 임태순;이유하;이득우;김정석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.155-160
    • /
    • 2002
  • Recently, the development of aerospace and automobile industries has brought new technological challenges, rebated to the growing complexity of products and the new geometry of the models. High speed milling with a 5-Axis milling machine has been widely used fur 3D sculptured surface parts. When turbine blades are machined by a 5-axis milling, their thin and cantilever shape causes vibrations, deflections and twists. Therefore, the surface roughness and the waviness of the workpiece are not good. In this paper, the effects of cutter orientation and the lead/tilt angle used to machine turbine blades with a 5-axis high speed ball end-milling were investigated to improve geometric accuracy and surface integrity. The experiments were performed using a lead/tilt angle of 15$^{\circ}$ to the workpiece with four cutter directions such as horizontal outward, horizontal inward, vertical outward, and vortical inward directions. Workpiece deflection, surface roughness and the machined surface were all measured with various cutter orientations such as cutting directions, and lead/tilt angle. The results show that the best cutting strategy for machining turbine blades with a 5-axis milling is horizontal inward direction with a tilt angle.

  • PDF

Part tolerancing through multicale defect analysis

  • Petitcuenot, Mathieu;Anselmetti, Bernard
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.109-119
    • /
    • 2016
  • When manufactured parts undergo large deformations during the manufacturing process, the global specifications of a part based on the concept of tolerance zone defined in the ISO 1101 standard [1] enable one to control the part's global defects. However, the extent of this tolerance zone is too large when the objective is to minimize local defects, such as hollows and bumps. Therefore, it is necessary to address local defects and global defects separately. This paper refers to the ISO 10579 standard [2] for flexible parts, which enables us to define a stressed state in order to measure the part by straightening it to simulate its position in the mechanism. The originality of this approach is that the straightening operation is performed numerically by calculating the displacement of a cloud of points. The results lead to a quantification of the global defects through various simple models and enable us to extract local defects. The outcome is an acceptable tolerance solution. The procedure is first developed for the simple example of a steel bar with a rectangular cross section, then applied to an industrial case involving a complex 3D surface of a turbine blade. The specification is described through ISO standards both in the free state and in the straightened state.

Performance of a Horizontal-axis Turbine Based on the Direction of Current Flow (수평축 조류발전 로터의 유향변화에 따른 효율 고찰)

  • Jo, Chul-Hee;Park, Ro-Sik;Yim, Jin-Young;Lee, Kang-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.8-12
    • /
    • 2010
  • The use of a tidal-current power system is one source of renewable energy that can minimize the environmental impact of power production and offer many other advantages compared to conventional energy sources. Unlike other energy production approaches, rate of energy production can be precisely predicted and the operational rate is very high. The performance of the rotor, which has a vital role in energy production using tidal currents, is determined by various design factors, and it should be optimized for the specific ocean environment in the field. The horizontal-axis turbine is very sensitive to the direction of flow, and flow direction changes due to rise and fall of the tides. To investigate the performance of the rotor considering the interaction problems with incidence angle of flow, a series of experiments were conducted, and a 3D CFD model was designed and analyzed by ANSYS CFX. The results and findings are summarized in the paper.