Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports (동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례)
-
- The Journal of Korean Academy of Prosthodontics
- /
- v.61 no.4
- /
- pp.328-343
- /
- 2023
Recently, a method of fabricating an esthetic anterior fixed prosthesis by integrating data such as three-dimensional facial scan and jaw motion to form a virtual patient with dynamic occlusion has been introduced. This enables smooth communication with patients during the diagnosis process, improves the predictability of esthetic prosthetic treatment, and lowers the possibility of occlusal adjustment. In this case report, a virtual patient with dynamic occlusion was created in which the results of the treatment were simulated, and esthetic maxillary anterior fixed prosthesis was fabricated. With the aid of the virtual patient, the final restorations were satisfactory both in terms of esthetic and function.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The objective of this paper is the establishment of finite element analysis frame work for pavement research. Finite element analysis results simulating various loading experiments are verified with sensor measurements obtained from the KHC Test Road. The accuracy of the finite element analysis can be supported by these efforts so that it helps spread out the finite element analysis to pavement research and design processes. The finite element model used in this research is the full 3D nonlinear model including concrete slab, lean concrete base, subbase, shoulder, dowel, and tie-bar. In order to accomplish the accurate verification, the loading condition and the pavement temperature distribution are exactly simulated with field measured data. The curling behavior and the strain distribution are compared with measured responses from the loading tests with a truck and the FWD. Strain and curling predictions from the concrete slab are matched well with measured responses but the strain prediction from the lean concrete base is not matched with measured response. In addition, the magnitude of permanent curling is evaluated with the finite element analysis.
In this work, an insulated coupling test machine for a 5-MW-class wind turbine was designed and developed, along with the public performance testing of a 3-MW-class wind turbine. The results of the device design, development requirements, functional considerations, structural vibration analysis, and the evaluation of the insulated coupling test machine are presented in this study. For the coupling models, thick fiberglass composite pipe insulation, fabricated by filament winding, was considered. Results of three-dimensional finite element analysis conducted using both solid element and shell element modeling were analyzed and compared, considering the effect of thickness. In addition, results from the nonlinear finite element analysis of multiple leaf springs of the laminated disk pack structure were verified and compared with experimental data.
Background: Extra nodal lymphoma (ENL) constitutes about 33 % of all non-Hodgkin's lymphoma. 18-28% develops in the head and neck region. A multimodality treatment with multi-agent chemotherapy (CT) and radiotherapy (RT) is considered optimum. Materials and Methods: We retrieved the treatment charts of patients of HNENL treated in our institute from 2001-2012. The charts were reviewed and the demographic, treatment details and outcome of HNENL patients were retrieved using predesigned pro-forma. Results: We retrieved data of 75consecutive patients HNENL. Median age was 47years (Range: 8-76 years). Of the 75 patients 51 were male and 24 were female. 55patients were evaluable. The patient and tumor characteristics are summarized in Table 1. All patients were staged comprehensively with contrast enhanced computed tomography of head, neck, thorax, abdomen, pelvis and bone marrow aspiration and biopsy 66 patients received a combination multi-agent CT with CHOP being the commonest regimen. 42 patients received 4 or lesser number of cycles of chemotherapy whereas 24received more than 4 cycles chemotherapy. Post radiotherapy, 41 out of 42 patients had a complete response at 3 months. Only 21patients had a complete response after chemotherapy. All patients received radiation (mostly involved field radiation) as a part of the treatment. The median radiation dose was 45 Gray (Range: 36 Gray-50 Gray). The radiation was planned by 2D fluoro simulation based technique in 37cases and by 3 Dimensional conformal radiation therapy (3DCRT) in 36 cases. Two patients were planned by the intensity modulated radiation therapy (IMRT) technique. IMRT was planned for one thyroid and one nasal cavity primary. 5 patients experienced relapse after a median follow up of 19 months. The median survival was not reached. The estimated two and three year survival were 92.9% (95%CI- 68.6- 95.35) and 88% (95%CI- 60.82 - 92.66) respectively. Univariate analysis revealed higher stage and poorer baseline performance status to be significantly associated with worse progression free survival. 5 patients progressed (relapse or primary disease progression) after treatment. Of the 5 patients, two patients were primary orbital NHL, two patients had NHL nasal cavity and one was NHL thyroid. Conclusions: Combined modality treatment in HNENL confers excellent disease control with acceptable side effects.
Chogye basin, which is surrounded by country rock, has a closed-basin form. In such a basin, incident seismic energy can form multiply reflected waves, thus causing energy concentration to occur at this closed-basin area. Microtremor measurement survey was performed at the Chogye basin, which is located in Chogye-myeon and Jeokjungmyeon, Hapcheon-gun, Gyeongsangnam-do, Republic of Korea. Microtremor data were transformed into the frequency domain, and then the horizontal-to-vertical spectral ratios (HVSR) were calculated. Fundamental resonance frequencies were estimated from the HVSR results for every observation point. Using the empirical relationship between site period and thickness for sediment sites in Korea known from the previous study, the distribution of sediment thickness of the Chogye basin was estimated from the fundamental resonance frequencies. Being compared with the mountainous rim with steep slope, the measurement points inside the basin have low values of the fundamental resonance frequency with the minimum of 1.03 Hz, which corresponds to the thickness of sedimentary layer with the maximum depth of about 100 m. A three-dimensional basin model was constructed for bedrock topography of the Chogye basin by an interpolation of basin depths estimated at each measurement site.
Recently, medical equipments are developed and used for diagnosis or studies. In addition, demand of techniques which automatically deal with three dimensional medical images obtained from the medical equipments is growing. One of the techniques is automatic bone segmentation which is expected to enhance the diagnosis efficiency of osteoporosis, fracture, and other bone diseases. Although various researches have been proposed to solve it, they are unable to be used in practice since a size of the medical data is large and there are many low contrast boundaries with other tissues. In this paper, we present a fast and accurate automatic framework for bone segmentation based on multi-resolutions. On a low resolution step, a position of the bone is roughly detected using constrained branch and mincut which find the optimal template from the training set. Then, the segmentation and the registration are iteratively conducted on the multiple resolutions. To evaluate the performance of the proposed method, we make an experiment with femur and tibia from 50 test knee magnetic resonance images using 100 training set. The proposed method outperformed the constrained branch and mincut in aspect of segmentation accuracy and implementation time.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
Trust is central to human relationships, at all times and places. The importance of trust is fundamental in all areas of human life, not only in the area of business administration. 2,500 years ago in China, Confucius taught that the foundation of politics was the trust of the people, more important even than military strength or the supply of food. Shakespeare's play, "Much Ado about Nothing' is about trust and deception. These days, trust and transparency in a commercial organization's business culture form the basis of the 'social capital' by which that organization increases its productivity. A successful company raises productivity by the accumulation of social capital, derived from a trust relationship between business partners, and between the company and consumers. Trust is the crucial factor. At the national level, building trust determines a nation's competitiveness. For a company, long term trust relationships with customers are essential for its survival in a business environment of rapid change. Such relationships, based on trust, are important assets to ensure a company's competitive advantage, and need to be organic to that company's business culture. Because of this importance, trust relationships have been studied in diverse areas within business administration, and especially within marketing, where they form the basis of a successful relationship between producer and consumer. However, what has been lacking is a unified definition of trust. Research has been conducted on the basis of various definitions and models. The majority of researchers have not considered the multidimensional character of the concept of trust until now. Approaches based on a one dimensional model have undermined the value of research results. Furthermore, researchers have only considered trust and trustworthiness as a single component. The majority of research has explored the consequences of perceived trust for outcomes such as loyalty or cooperation, but has neglected the effects of trustworthiness upon the mechanisms of consumer trust. This study focuses on the dimension of trust from such a perspective. It seeks to verify the effect of trust on customer intentions by breaking it down into three separate components: 1) the salesperson, 2) the product/service, and 3) the company. The purposes of this paper are as follows: Firstly, we review the multidimensional nature of trust objects: the salesperson, the product/service, and the company. Secondly, we analyze the relationship between multidimensional trust and trustworthiness. Thirdly, we analyze the connection between trust and repeat purchase intentions for the maintenance of long term relationships. For these purposes the author has developed several hypotheses as follows: H1-1: The competence of a salesperson is positively associated with the trust given by the consumer to the salesperson. H1-2: The benevolence of a salesperson is positively associated with the trust given by the consumer to the salesperson. H2-1: The competence of product/service is positively associated with the trust given by the consumer to the product/service. H2-2: The benevolence of product/service is positively associated with the trust given by the consumer to the product/service. H3-1: The reputation of a company is positively associated with the trust given by the consumer to the company. H3-2: The physical environment of a company is positively associated with the trust given by the consumer to the company. H4-1: Trust in a salesperson is positively associated with repeat purchase intentions. H4-2: Trust in a product/service is positively associated with repeat purchase intentions. H4-3: Trust in a company is positively associated with repeat purchase intentions. The data was compiled from 366 questionnaires. 500 questionnaires were collected, but some of the data was considered unsuitable and inappropriate. The subjects of the survey were male and female customers purchasing products at department stores in Seoul, Daegu and Gyeongbuk. It was carried out between Oct. 25 and 29, 2007. The data was analyzed by frequency analysis using SPSS 12.0 and structural equation modeling using LISREL 8.7. The result of the overall model analysis is as follows: Chi-Square=445.497, d.f.=185, p-value=0.0, GFI=.901, RMSEA=.0617, NNFI=.986, NFI=.981, CFI=.989, AGFI=.864, RMR=.0872. The results of the overall model analysis were coherent. It was found that trust is a multi-dimensional construct, that each of the dimensions of trust are meaningful influences on customer's repurchase intention. Trust in a company may be the most relevant, while trust in a product/service and a salesperson may be less relevant to repurchase intentions. The effective factors in determining trust in a salesperson and a company's product/service were found to be competence and benevolence. Factors in determining trust in a company were its reputation and physical environment, and the relationship of each effective trust factor has been verified in this research. As a result, it was found that competence and benevolence have a meaningful influence on trust in a salesperson and in product/service. It was also found that a company's reputation influences the overall trust in the company significantly but a company's physical environment does not have much effect.
The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.